Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | SCHEDULE \"A\" PART - I (Schedule of Works (E/M) |
| 2 | Dismantling and taking out Plain cement concrete pole/Steel tubular of any size including breaking of PCC foundation and earth work etc and removal of debris where directed complete all as specified and as directed. |
| 3 | Dismantling old unserviceable stay assembly complete of any size complete all as specified and as directed. |
| 4 | Dismantling of old unserviceable ACSR/Conductor of any size for LT OH line complete all as specified and as directed. |
| 5 | Dismantling/taking down cross arms, bracings, support, clamp including nuts, bolts and washers complete all as specified and as directed. |
| 6 | Dismantling ofinsulators LT of any size for removal or refixing at site complete all as specified and as directed. |
| 7 | Dismantling and taking out OldLT panel of any type duly disconnecting the incoming and out going cables, switch gears, instruments and other spares/accessories carefully for re use serviceable items and old unserviceable spares shall be leave with panel for credit schedule complete all as specified and as directed. |
| 8 | Material and labor for removing serviceable LT cable of any size duly testing the cable by the megger and taking downexisting serviceable for relaying as specified such as relaying/rerouting and shifting the cable to laying as required at site complete all as specified and as directed.Note: Taking down removal of the cable rates deemed to include in quoted rates. |
| 9 | Material and labour for removing brick/cover from trench for re use of serviceable bricks/PCC covers and re-laying old serviceable bricks of any type and size bricks, for cable protection in trenches laid dry and flat over the relaid/re-routing cables complete all as specified and directed by Engineer-in-Charge |
| 10 | Supply and lay cable XLPE Insulated screenedPVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty)1100 Volts grade with stranded aluminiumconductor of size240 sq mm 3½ core including provision of LT cable path indicator CI round shape mentioning LT cable of Blue color paint fixed with 0.75 Mtr length angle iron of size 40x40x4 mm laying intervals 20 Mtr and referlaying of cable shall be compile with SSR Part -I Section 19.75.1 complete all as specified and as directed. Note: Cable path indicators and end termination joints with aluminium lugs/thimbles deemed to include with quoted rates |
| 11 | All as per serial item No.9 but size 185 sq mm 3.5 core |
| 12 | All as per serial item No.9 but size 150 sq mm 3.5 core |
| 13 | All as per serial item No.9 but size 120 sq mm 3½ core |
| 14 | All as per serial item No.9 but size 95 sq mm 3½ core |
| 15 | All as per serial item No.9 but size 70 sq mm 3½ core |
| 16 | All as per serial item No.9 but size 50 sq mm 3½ core |
| 17 | All as per serial item No.9 but size 35 sq mm 3½ core |
| 18 | All as per serial item No.9 but size 25 sq mm 4 core |
| 19 | All as per serial item No.9 but size 16 sq mm 4 core |
| 20 | All as per serial item No.9 but size 10 sq mm 4 core |
| 21 | All as per serial item No.9 but size 25 sq mm 2 core |
| 22 | All as per serial item No.9 but size 16 sq mm 2 core |
| 23 | All as per serial item No.9 but size 10 sq mm 2 core |
| 24 | Supply & install, commissioning, testing of out door type Main panel board -1(CPRI approved) and confirming to IS 5036totally enclosed made out of 3.15 mm thick sheet metal enclosure with angle iron frame of M.S. angle 50x50x6 mm suitable for operation on 3 phase 4 wire, 440 volts 50 HZ system, with hinged panel centre opening front and rear opening doors (covers) with handles, each control switch to be fixed in each compartment with hinged door, bottom gland plate and locking arrangement consisting of sufficient Nos of circular cable entry holes at bottom only with suitable PVC/rubber/wooden bushes to prevent ingress of water/vermin etc, inside the enclosure, the required nos of holes to be fixed with chromium plated brass cable glands for cable entry and exit complete with necessary internal wiring with stranded copper conductor PVC insulated cables of adequate size, dulywith powder coated, painted one coat of red oxide primer and two coats of synthetic enamel paint of gray or any other approved colour and bus bar 1000 Amps forphase & neutral 500 Amps capacity mounted on epoxy insulator-01 Set including comprising the following. |
| 25 | INCOMINGSupply & fix ACBLT switch gear 440 Volts 3 phase, 4 wire 50 cycles, cubicle or truck type complete with air circuit breaker, overload protection, no-volt release with necessary CTs,meter and cable boxes of rating of cap 630 Amps-01 NoOUT GOINGMCCB 4 pole,415 volt ,50 Hz , rupturing cap 63A, 25 KA -03 NosMCCB 4 pole,415 volt ,50 Hz , rupturing cap 40A , 25 KA -03 NosMCCB 4 pole,415 volt ,50 Hz , rupturing cap, 350A 36 KA -02 NosMCB TPN(6-32A) 10KA -02 NoAstronomical time switch complete with all accessories in built panel-01 Setdigital Volt, Ammeter& Freq Meter incl selector switch-01SetIndicator, danger board, line diagram,-01 Set |
| 26 | Supply & install, commissioning, testing of out door type Main panel board -2(CPRI approved) and confirming to IS 5036totally enclosed made out of 3.15 mm thick sheet metal enclosure with angle iron frame of M.S. angle 50x50x6 mm suitable for operation on 3 phase 4 wire, 440 volts 50 HZ system, with hinged panel centre opening front and rear opening doors (covers) with handles, each control switch to be fixed in each compartment with hinged door, bottom gland plate and locking arrangement consisting of sufficient Nos of circular cable entry holes at bottom only with suitable PVC/rubber/wooden bushes to prevent ingress of water/vermin etc, inside the enclosure, the required nos of holes to be fixed with chromium plated brass cable glands for cable entry and exit complete with necessary internal wiring with stranded copper conductor PVC insulated cables of adequate size, dulywith powder coated, painted one coat of red oxide primer and two coats of synthetic enamel paint of gray or any other approved colour and bus bar 1200 Amps forphase & neutral 600 Amps capacity mounted on epoxy insulator-01 Set including comprising the following. |
| 27 | INCOMINGSupply & fix ACBLT switch gear 440 Volts 3 phase, 4 wire 50 cycles, cubicle or truck type complete with air circuit breaker, overload protection, no-volt release with necessary CTs,meter and cable boxes of rating upto 800 Amps-01 NoOUT GOINGMCCB 4 pole,415 volt ,50 Hz , rupturing cap 32A, 25 KA -01 NoMCCB 4 pole,415 volt ,50 Hz , rupturing cap 63 A, 25 KA -03 NosMCCB 4 pole,415 volt ,50 Hz , rupturing cap 160 A, 35 KA -03 NosMCCB 4 pole,415 volt ,50 Hz , rupturing cap 200 A, 35 KA -01 NoMCB TPN(6-32A) 10KA -03 NosMCB DP 6-40 A,230V , 50 HZ ,16 KA-07 NosAstronomical time switch complete with all accessories in built panel-01 Setdigital Volt, Ammeter& Freq Meter incl selector switch-01SetIndicator, danger board, line diagram,-01 Set |
| 28 | Supply & install, commissioning, testing of out door type Main panel board -3 LT type (CPRI approved) and confirming to IS 5036totally enclosed made out of 3.15 mm thick sheet metal enclosure with angle iron frame of M.S. angle 50x50x6 mm suitable for operation on 3 phase 4 wire, 440 volts 50 HZ system, with hinged panel centre opening front and rear opening doors (covers) with handles, each control switch to be fixed in each compartment with hinged door, bottom gland plate and locking arrangement consisting of sufficient Nos of circular cable entry holes at bottom only with suitable PVC/rubber/wooden bushes to prevent ingress of water/vermin etc, inside the enclosure, the required nos of holes to be fixed with chromium plated brass cable glands for cable entry and exit complete with necessary internal wiring with stranded copper conductor PVC insulated cables of adequate size, dulywith powder coated, painted one coat of red oxide primer and two coats of synthetic enamel paint of gray or any other approved colour and bus bar 1500 Amps forphase & neutral 750 Amps capacity mounted on epoxy insulator-01 Set including comprising the following. |
| 29 | INCOMINGSupply & fix ACBLT switch gear 440 Volts 3 phase, 4 wire 50 cycles, cubicle or truck type complete with air circuit breaker, overload protection, no-volt release with necessary CTs,meter and cable boxes of rating upto 1000 Amps-01 NoOUT GOINGMCCB 4 pole,415 volt ,50 Hz ,400 Amp of rupturing cap 35 KA -02 NosMCCB 4 pole,415 volt ,50 Hz ,300 Amp ofrupturing cap 36 KA -01 NoMCCB 4 pole,415 volt ,50 Hz ,160 Amp ofrupturing cap 36 KA -01 NoMCCB 4 pole,415 volt ,50 Hz , 80 Amp of rupturing cap 25 KA -03 NosMCCB 4 pole,415 volt ,50 Hz , 40 Amp of rupturing cap 25 KA -01 NoMCB TPN(6-32A) 10KA -02 NoAstronomical time switch complete with all accessories in built panel-01 Setdigital Volt, Ammeter& Freq Meter incl selector switch-01SetIndicator, danger board, line diagram,-01 Set |
| 30 | Supply & install, commissioning, testing of out door type Main panel board -4LT type (CPRI approved) and confirming to IS 5036totally enclosed made out of 3.15 mm thick sheet metal enclosure with angle iron frame of M.S. angle 50x50x6 mm suitable for operation on 3 phase 4 wire, 440 volts 50 HZ system, with hinged panel centre opening front and rear opening doors (covers) with handles, each control switch to be fixed in each compartment with hinged door, bottom gland plate and locking arrangement consisting of sufficient Nos of circular cable entry holes at bottom only with suitable PVC/rubber/wooden bushes to prevent ingress of water/vermin etc, inside the enclosure, the required nos of holes to be fixed with chromium plated brass cable glands for cable entry and exit complete with necessary internal wiring with stranded copper conductor PVC insulated cables of adequate size, dulywith powder coated, painted one coat of red oxide primer and two coats of synthetic enamel paint of gray or any other approved colour and bus bar 600 Amps forphase & neutral 300 Amps capacity mounted on epoxy insulator-01 Set including comprising the following. |
| 31 | INCOMINGMCCB 4 pole,415 volt ,50 Hz ,400 Amp of rupturing cap50KA -01 NoOUT GOINGMCCB 4 pole,415 volt ,50 Hz , 150 Amp of rupturing cap 35 KA -03 NosMCCB 4 pole,415 volt ,50 Hz , 125 Amp of rupturing cap 25 KA -01 NoMCCB 4 pole,415 volt ,50 Hz ,100 Amp of rupturing cap 25 KA -01 NoMCB TPN(6-32A) 10KA -01 NoMCB DP (6-40A) 230 Volt single ph,10KA- 02NosAstronomical time switch complete with all accessories in built panel-01 Setdigital Volt, Ammeter& Freq Meter incl selector switch-01SetIndicator, danger board, line diagram,-01 Set |
| 32 | Supply & install, commissioning, testing of out door type Feeder pillar box (Sub panel 1/1), LT type (CPRI approved)and confirming to IS 5036totally enclosed made out of 3.15 mm thick sheet metal enclosure with angle iron frame of M.S. angle 50x50x6 mm suitable for operation on 3 phase 4 wire, 440 volts 50 HZ system, with hinged panel centre opening front and rear opening doors (covers) with handles, each control switch to be fixed in each compartment with hinged door, bottom gland plate and locking arrangement consisting of sufficient Nos of circular cable entry holes at bottom only with suitable PVC/rubber/wooden bushes to prevent ingress of water/vermin etc, inside the enclosure, the required nos of holes to be fixed with chromium plated brass cable glands for cable entry and exit complete with necessary internal wiring with stranded copper conductor PVC insulated cables of adequate size, dulywith powder coated, painted one coat of red oxide primer and two coats of synthetic enamel paint of gray or any other approved colour and bus bar 400 Amps forphase & neutral 200 Amps capacity mounted on epoxy insulator-01 Set including comprising the following. |
| 33 | INCOMINGMCCB 4 pole,415 volt ,50 Hz , rupturing cap 300 A of35 KA -01 NoOUT GOINGMCCB 4 pole,415 volt ,50 Hz , rupturing cap 63 A of 25 KA-07 Nosdigital Volt, Ammeter& Freq Meter incl selector switch-01SetIndicator, danger board, line diagram,-01 Set |
| 34 | Supply & install, commissioning, testing of out door type Feeder pillar box (Sub panel 1/2), LT type (CPRI approved) and confirming to IS 5036totally enclosed made out of 3.15 mm thick sheet metal enclosure with angle iron frame of M.S. angle 50x50x6 mm suitable for operation on 3 phase 4 wire, 440 volts 50 HZ system, with hinged panel centre opening front and rear opening doors (covers) with handles, each control switch to be fixed in each compartment with hinged door, bottom gland plate and locking arrangement consisting of sufficient Nos of circular cable entry holes at bottom only with suitable PVC/rubber/wooden bushes to prevent ingress of water/vermin etc, inside the enclosure, the required nos of holes to be fixed with chromium plated brass cable glands for cable entry and exit complete with necessary internal wiring with stranded copper conductor PVC insulated cables of adequate size, dulywith powder coated, painted one coat of red oxide primer and two coats of synthetic enamel paint of gray or any other approved colour and bus bar 500 Amps forphase & neutral 250 Amps capacity mounted on epoxy insulator-01 Set including comprising the following. |
| 35 | INCOMINGMCCB 4 pole,415 volt ,50 Hz , rupturing cap 320A,35 KA -01 NoOUT GOINGMCCB 4 pole,415 volt ,50 Hz , rupturing cap 40A, 16 KA-03 NosMCCB 4 pole,415 volt ,50 Hz , rupturing cap 63A, 16 KA -05 NosMCB TPN(6-32A) 10KA -01 Nodigital Volt, Ammeter& Freq Meter incl selector switch-01SetIndicator, danger board, line diagram,-01 Set |
| 36 | Supply & install, commissioning, testing of out door type Feeder pillar box (Sub panel 1/3) , LT type (CPRI approved) and confirming to IS 5036totally enclosed made out of 3.15 mm thick sheet metal enclosure with angle iron frame of M.S. angle 50x50x6 mm suitable for operation on 3 phase 4 wire, 440 volts 50 HZ system, with hinged panel centre opening front and rear opening doors (covers) with handles, each control switch to be fixed in each compartment with hinged door, bottom gland plate and locking arrangement consisting of sufficient Nos of circular cable entry holes at bottom only with suitable PVC/rubber/wooden bushes to prevent ingress of water/vermin etc, inside the enclosure, the required nos of holes to be fixed with chromium plated brass cable glands for cable entry and exit complete with necessary internal wiring with stranded copper conductor PVC insulated cables of adequate size, dulywith powder coated, painted one coat of red oxide primer and two coats of synthetic enamel paint of gray or any other approved colour and bus bar 200 Amps forphase & neutral 100 Amps capacity mounted on epoxy insulator-01 Set including comprising the following. |
| 37 | INCOMINGMCCB 4 pole,415 volt ,50 Hz , rupturing cap 63A,25 KA -01 NoOUT GOINGMCCB 4 pole,415 volt ,50 Hz , rupturing cap 40A, 16 KA-03 Nos digital Volt, Ammeter& Freq Meter incl selector switch-01SetIndicator, danger board, line diagram,-01 Set |
| 38 | Supply & install, commissioning, testing of out door type Feeder pillar box (Sub panel 2/1)LT type (CPRI approved) and confirming to IS 5036totally enclosed made out of 3.15 mm thick sheet metal enclosure with angle iron frame of M.S. angle 50x50x6 mm suitable for operation on 3 phase 4 wire, 440 volts 50 HZ system, with hinged panel centre opening front and rear opening doors (covers) with handles, each control switch to be fixed in each compartment with hinged door, bottom gland plate and locking arrangement consisting of sufficient Nos of circular cable entry holes at bottom only with suitable PVC/rubber/wooden bushes to prevent ingress of water/vermin etc, inside the enclosure, the required nos of holes to be fixed with chromium plated brass cable glands for cable entry and exit complete with necessary internal wiring with stranded copper conductor PVC insulated cables of adequate size, dulywith powder coated, painted one coat of red oxide primer and two coats of synthetic enamel paint of gray or any other approved colour and bus bar 200 Amps forphase & neutral 100 Amps capacity mounted on epoxy insulator-01 Set including comprising the following. |
| 39 | INCOMINGMCCB 4 pole,415 volt ,50 Hz , rupturing cap 100A,25 KA -01 NoOUT GOINGMCCB 4 pole,415 volt ,50 Hz , rupturing cap 40 A 16 KA -02 NosMCCB 4 pole,415 volt ,50 Hz , rupturing cap 20A, 16 KA -02 NosMCB TPN(6-32A) 10KA -01 NoMCB DP (6-40A) 230 Volt single ph,10KA-03 Nosdigital Volt, Ammeter& Freq Meter incl selector switch-01SetIndicator, danger board, line diagram,-01 Set |
| 40 | Supply & install, commissioning, testing of out door type Feeder pillar box (Sub panel 2/2), LT type (CPRI approved) and confirming to IS 5036totally enclosed made out of 3.15 mm thick sheet metal enclosure with angle iron frame of M.S. angle 50x50x6 mm suitable for operation on 3 phase 4 wire, 440 volts 50 HZ system, with hinged panel centre opening front and rear opening doors (covers) with handles, each control switch to be fixed in each compartment with hinged door, bottom gland plate and locking arrangement consisting of sufficient Nos of circular cable entry holes at bottom only with suitable PVC/rubber/wooden bushes to prevent ingress of water/vermin etc, inside the enclosure, the required nos of holes to be fixed with chromium plated brass cable glands for cable entry and exit complete with necessary internal wiring with stranded copper conductor PVC insulated cables of adequate size, dulywith powder coated, painted one coat of red oxide primer and two coats of synthetic enamel paint of gray or any other approved colour and bus bar 300 Amps forphase & neutral 150 Amps capacity mounted on epoxy insulator-01 Set including comprising the following. |
| 41 | INCOMINGMCCB 4 pole,415 volt ,50 Hz , rupturing cap 200A of35 KA -01 NoOUT GOINGMCCB 4 pole,415 volt ,50 Hz , rupturing cap 150A of 26 KA -02 NosMCCB 4 pole,415 volt ,50 Hz , rupturing cap 20A of 16 KA -01 NoMCB TPN(6-32A) 10KA -01 NoMCB DP (6-40A) 230 Volt single ph,10KA-03 Nosdigital Volt, Ammeter& Freq Meter incl selector switch-01SetIndicator, danger board, line diagram,-01 Set |
| 42 | Supply & install, commissioning, testing of out door type Feeder pillar box (Sub panel 2/3), LT type (CPRI approved) and confirming to IS 5036totally enclosed made out of 3.15 mm thick sheet metal enclosure with angle iron frame of M.S. angle 50x50x6 mm suitable for operation on 3 phase 4 wire, 440 volts 50 HZ system, with hinged panel centre opening front and rear opening doors (covers) with handles, each control switch to be fixed in each compartment with hinged door, bottom gland plate and locking arrangement consisting of sufficient Nos of circular cable entry holes at bottom only with suitable PVC/rubber/wooden bushes to prevent ingress of water/vermin etc, inside the enclosure, the required nos of holes to be fixed with chromium plated brass cable glands for cable entry and exit complete with necessary internal wiring with stranded copper conductor PVC insulated cables of adequate size, dulywith powder coated, painted one coat of red oxide primer and two coats of synthetic enamel paint of gray or any other approved colour and bus bar 400 Amps forphase & neutral 200 Amps capacity mounted on epoxy insulator-01 Set including comprising the following. |
| 43 | INCOMINGMCCB 4 pole,415 volt ,50 Hz , rupturing cap 250Amp of35 KA- 01 NoOUT GOINGMCCB 4 pole,415 volt ,50 Hz , rupturing cap125Amp of 16 KA -02 NoMCCB 4 pole,415 volt ,50 Hz , rupturing cap 32amp of16 KA -03 NosMCCB 4 pole,415 volt ,50 Hz , rupturing cap 25amp of16 KA -02 NosMCB DP (6-40A) 230 Volt single ph,10KA-03 Nosdigital Volt, Ammeter& Freq Meter incl selector switch-01SetIndicator, danger board, line diagram,-01 Set |
| 44 | Supply & install, commissioning, testing of out door type Feeder pillar box (Sub panel 2/4) LT type (CPRI approved) and confirming to IS 5036totally enclosed made out of 3.15 mm thick sheet metal enclosure with angle iron frame of M.S. angle 50x50x6 mm suitable for operation on 3 phase 4 wire, 440 volts 50 HZ system, with hinged panel centre opening front and rear opening doors (covers) with handles, each control switch to be fixed in each compartment with hinged door, bottom gland plate and locking arrangement consisting of sufficient Nos of circular cable entry holes at bottom only with suitable PVC/rubber/wooden bushes to prevent ingress of water/vermin etc, inside the enclosure, the required nos of holes to be fixed with chromium plated brass cable glands for cable entry and exit complete with necessary internal wiring with stranded copper conductor PVC insulated cables of adequate size, dulywith powder coated, painted one coat of red oxide primer and two coats of synthetic enamel paint of gray or any other approved colour and bus bar 200 Amps forphase & neutral 100 Amps capacity mounted on epoxy insulator-01 Set including comprising the following. |
| 45 | INCOMINGMCCB 4 pole,415 volt ,50 Hz , rupturing cap 63Amp of 25 KA -01 NoOUT GOINGMCCB 4 pole,415 volt ,50 Hz , rupturing cap 25 Amp of16 KA -01 NoMCCB 4 pole,415 volt ,50 Hz , rupturing cap 32 Amp of16 KA -02 NosMCB DP (6-40A) 230 Volt single ph,10 KA-03 Nosdigital Volt, Ammeter& Freq Meter incl selector switch-01SetIndicator, danger board, line diagram,-01 Set |
| 46 | Supply & install, commissioning, testing of out door type Feeder pillar box (Sub panel 2/5) LT type (CPRI approved) and confirming to IS 5036totally enclosed made out of 3.15 mm thick sheet metal enclosure with angle iron frame of M.S. angle 50x50x6 mm suitable for operation on 3 phase 4 wire, 440 volts 50 HZ system, with hinged panel centre opening front and rear opening doors (covers) with handles, each control switch to be fixed in each compartment with hinged door, bottom gland plate and locking arrangement consisting of sufficient Nos of circular cable entry holes at bottom only with suitable PVC/rubber/wooden bushes to prevent ingress of water/vermin etc, inside the enclosure, the required nos of holes to be fixed with chromium plated brass cable glands for cable entry and exit complete with necessary internal wiring with stranded copper conductor PVC insulated cables of adequate size, dulywith powder coated, painted one coat of red oxide primer and two coats of synthetic enamel paint of gray or any other approved colour and bus bar250 Amps forphase & neutral 150 Amps capacity mounted on epoxy insulator-01 Set including comprising the following. |
| 47 | INCOMINGMCCB 4 pole,415 volt ,50 Hz , 160Amp of rupturing cap25 KA -01 NoOUT GOINGMCCB 4 pole,415 volt ,50 Hz ,125 Amp of rupturing cap 25 KA -02 NosMCCB 4 pole,415 volt ,50 Hz , 63 Amp of rupturing cap 25 KA -01 NoMCB DP (6-40A) 230 Volt single ph,10KA-03 Nosdigital Volt, Ammeter& Freq Meter incl selector switch-01SetIndicator, danger board, line diagram,-01 Set |
| 48 | Supply & install, commissioning, testing of out door type Feeder pillar box (Sub panel 3/1), LT type (CPRI approved) and confirming to IS 5036totally enclosed made out of 3.15 mm thick sheet metal enclosure with angle iron frame of M.S. angle 50x50x6 mm suitable for operation on 3 phase 4 wire, 440 volts 50 HZ system, with hinged panel centre opening front and rear opening doors (covers) with handles, each control switch to be fixed in each compartment with hinged door, bottom gland plate and locking arrangement consisting of sufficient Nos of circular cable entry holes at bottom only with suitable PVC/rubber/wooden bushes to prevent ingress of water/vermin etc, inside the enclosure, the required nos of holes to be fixed with chromium plated brass cable glands for cable entry and exit complete with necessary internal wiring with stranded copper conductor PVC insulated cables of adequate size, dulywith powder coated, painted one coat of red oxide primer and two coats of synthetic enamel paint of gray or any other approved colour and bus bar 450 Amps forphase & neutral 250 Amps capacity mounted on epoxy insulator-01 Set including comprising the following. |
| 49 | INCOMINGMCCB 4 pole,415 volt ,50 Hz , 300 Amp ofrupturing cap 35 KA - 01 NoOUT GOINGMCCB 4 pole,415 volt , 50 Hz ,63 Amp of, rupturing cap 16 KA -03 NosMCCB 4 pole,415 volt , 50 Hz ,200 Amp of rupturing cap 26 KA -02 NosMCB DP (6-40A) 230 Volt single ph,10KA-04 Nosdigital Volt, Ammeter& Freq Meter incl selector switch-01SetIndicator, danger board, line diagram,-01 Set |
| 50 | Supply & install, commissioning, testing of out door type Feeder pillar box (Sub panel 3/2), LT type (CPRI approved) and confirming to IS 5036totally enclosed made out of 3.15 mm thick sheet metal enclosure with angle iron frame of M.S. angle 50x50x6 mm suitable for operation on 3 phase 4 wire, 440 volts 50 HZ system, with hinged panel centre opening front and rear opening doors (covers) with handles, each control switch to be fixed in each compartment with hinged door, bottom gland plate and locking arrangement consisting of sufficient Nos of circular cable entry holes at bottom only with suitable PVC/rubber/wooden bushes to prevent ingress of water/vermin etc, inside the enclosure, the required nos of holes to be fixed with chromium plated brass cable glands for cable entry and exit complete with necessary internal wiring with stranded copper conductor PVC insulated cables of adequate size, dulywith powder coated, painted one coat of red oxide primer and two coats of synthetic enamel paint of gray or any other approved colour and bus bar 300 Amps forphase & neutral 150 Amps capacity mounted on epoxy insulator-01 Set including comprising the following. |
| 51 | INCOMINGMCCB 4 pole,415 volt ,50 Hz , 200 Amp of rupturing cap 35 KA -01 NoOUT GOINGMCCB 4 pole,415 volt ,50 Hz ,100 Amp ofrupturing cap 16 KA -01 NoMCCB 4 pole,415 volt ,50 Hz ,63 Amp ofrupturing cap 16 KA -03 NosMCCB 4 pole,415 volt ,50 Hz , 20 Amp of rupturing cap 16 KA -01 NoMCB DP (6-40A) 230 Volt single ph,10KA-04 Nosdigital Volt, Ammeter& Freq Meter incl selector switch-01SetIndicator, danger board, line diagram,-01 Set |
| 52 | Supply & install, commissioning, testing of out door type Feeder pillar box (Sub panel 3/3), LT type (CPRI approved) and confirming to IS 5036totally enclosed made out of 3.15 mm thick sheet metal enclosure with angle iron frame of M.S. angle 50x50x6 mm suitable for operation on 3 phase 4 wire, 440 volts 50 HZ system, with hinged panel centre opening front and rear opening doors (covers) with handles, each control switch to be fixed in each compartment with hinged door, bottom gland plate and locking arrangement consisting of sufficient Nos of circular cable entry holes at bottom only with suitable PVC/rubber/wooden bushes to prevent ingress of water/vermin etc, inside the enclosure, the required nos of holes to be fixed with chromium plated brass cable glands for cable entry and exit complete with necessary internal wiring with stranded copper conductor PVC insulated cables of adequate size, dulywith powder coated, painted one coat of red oxide primer and two coats of synthetic enamel paint of gray or any other approved colour and bus bar 200 Amps forphase & neutral 100 Amps capacity mounted on epoxy insulator-01 Set including comprising the following. |
| 53 | INCOMINGMCCB 4 pole,415 volt ,50 Hz , 100 Amp ofrupturing cap 25 KA -01 NoOUT GOINGMCCB 4 pole,415 volt ,50 Hz , 40 Amp ofrupturing cap 16 KA -02 NosMCCB 4 pole,415 volt ,50 Hz , 20 Amp of rupturing cap 16 KA -02 NosMCB DP (6-40A) 230 Volt single ph,10KA-06 NosDigital Volt, Ammeter& Freq Meter incl selector switch -01 SetIndicator, danger board, line diagram - 01 set |
| 54 | Supply & install, commissioning, testing of out door type Feeder pillar box (Sub panel 3/5) including with following LT switch gears, LT type (CPRI approved) and confirming to IS 5036totally enclosed made out of 3.15 mm thick sheet metal enclosure with angle iron frame of M.S. angle 50x50x6 mm suitable for operation on 3 phase 4 wire, 440 volts 50 HZ system, with hinged panel centre opening front and rear opening doors (covers) with handles, each control switch to be fixed in each compartment with hinged door, bottom gland plate and locking arrangement consisting of sufficient Nos of circular cable entry holes at bottom only with suitable PVC/rubber/wooden bushes to prevent ingress of water/vermin etc, inside the enclosure, the required nos of holes to be fixed with chromium plated brass cable glands for cable entry and exit complete with necessary internal wiring with stranded copper conductor PVC insulated cables of adequate size, dulywith powder coated, painted one coat of red oxide primer and two coats of synthetic enamel paint of gray or any other approved colour and bus bar 200 Amps forphase & neutral 100 Amps capacity mounted on epoxy insulator-01 Set including comprising the following. |
| 55 | INCOMINGMCCB 4 pole,415 volt ,50 Hz , 63 Amp of rupturing cap 16 KA -01 NoOUT GOINGMCB TPN(6-32A) 10KA - 03 NosMCB DP (6-40A) 230 Volt single ph,10KA-04 NosDigital Volt, Ammeter& Freq Meter incl selector switch -01 SetIndicator, danger board, line diagram - 01 set |
| 56 | Supply & install, commissioning, testing of out door type Feeder pillar box (Sub panel 4/1) , LT type (CPRI approved) and confirming to IS 5036totally enclosed made out of 3.15 mm thick sheet metal enclosure with angle iron frame of M.S. angle 50x50x6 mm suitable for operation on 3 phase 4 wire, 440 volts 50 HZ system, with hinged panel centre opening front and rear opening doors (covers) with handles, each control switch to be fixed in each compartment with hinged door, bottom gland plate and locking arrangement consisting of sufficient Nos of circular cable entry holes at bottom only with suitable PVC/rubber/wooden bushes to prevent ingress of water/vermin etc, inside the enclosure, the required nos of holes to be fixed with chromium plated brass cable glands for cable entry and exit complete with necessary internal wiring with stranded copper conductor PVC insulated cables of adequate size, dulywith powder coated, painted one coat of red oxide primer and two coats of synthetic enamel paint of gray or any other approved colour and bus bar 200 Amps forphase & neutral 100 Amps capacity mounted on epoxy insulator-01 Set including comprising the following. |
| 57 | INCOMINGMCCB 4 pole,415 volt ,50 Hz , 63 Amp of rupturing cap 25 KA -01 NoOUT GOINGMCB TPN(6-32A) 10KA - 02 NosMCB DP (6-40A) 230 Volt single ph,10KA-06 Nosdigital Volt, Ammeter& Freq Meter incl selector switch-01SetIndicator, danger board, line diagram,-01 Set |
| 58 | Supply & install, commissioning, testing of out door type Feeder pillar box (Sub panel 4/2), LT type (CPRI approved) and confirming to IS 5036totally enclosed made out of 3.15 mm thick sheet metal enclosure with angle iron frame of M.S. angle 50x50x6 mm suitable for operation on 3 phase 4 wire, 440 volts 50 HZ system, with hinged panel centre opening front and rear opening doors (covers) with handles, each control switch to be fixed in each compartment with hinged door, bottom gland plate and locking arrangement consisting of sufficient Nos of circular cable entry holes at bottom only with suitable PVC/rubber/wooden bushes to prevent ingress of water/vermin etc, inside the enclosure, the required nos of holes to be fixed with chromium plated brass cable glands for cable entry and exit complete with necessary internal wiring with stranded copper conductor PVC insulated cables of adequate size, dulywith powder coated, painted one coat of red oxide primer and two coats of synthetic enamel paint of gray or any other approved colour and bus bar 200 Amps forphase & neutral 100 Amps capacity mounted on epoxy insulator-01 Set including comprising the following. |
| 59 | INCOMINGMCCB 4 pole,415 volt ,50 Hz , 63 Amp of rupturing cap 25 KA -01 NoOUT GOINGMCB TPN(6-32A) 10KA - 02 NosMCB DP (6-40A) 230 Volt single ph,10KA-11 Nosdigital Volt, Ammeter& Freq Meter incl selector switch-01SetIndicator, danger board, line diagram,-01 Set |
| 60 | Supply & install, commissioning, testing of out door type Feeder pillar box (Sub panel 4/3) LT type (CPRI approved)and confirming to IS 5036totally enclosed made out of 3.15 mm thick sheet metal enclosure with angle iron frame of M.S. angle 50x50x6 mm suitable for operation on 3 phase 4 wire, 440 volts 50 HZ system, with hinged panel centre opening front and rear opening doors (covers) with handles, each control switch to be fixed in each compartment with hinged door, bottom gland plate and locking arrangement consisting of sufficient Nos of circular cable entry holes at bottom only with suitable PVC/rubber/wooden bushes to prevent ingress of water/vermin etc, inside the enclosure, the required nos of holes to be fixed with chromium plated brass cable glands for cable entry and exit complete with necessary internal wiring with stranded copper conductor PVC insulated cables of adequate size, dulywith powder coated, painted one coat of red oxide primer and two coats of synthetic enamel paint of gray or any other approved colour and bus bar 200 Amps forphase & neutral 100 Amps capacity mounted on epoxy insulator-01 Set including comprising the following. |
| 61 | INCOMINGMCCB 4 pole,415 volt ,50 Hz , 100 Amp of rupturing cap 25 KA -01 NoOUT GOINGMCB TPN(6-32A) 10KA - 06 NosMCB DP (6-40A) 230 Volt single ph,10KA-03 Nosdigital Volt, Ammeter& Freq Meter incl selector switch-01SetIndicator, danger board, line diagram,-01 Set |
| 62 | Supply & install, commissioning, testing of out door type Feeder pillar box (Sub panel 4/4) , LT type (CPRI approved) and confirming to IS 5036totally enclosed made out of 3.15 mm thick sheet metal enclosure with angle iron frame of M.S. angle 50x50x6 mm suitable for operation on 3 phase 4 wire, 440 volts 50 HZ system, with hinged panel centre opening front and rear opening doors (covers) with handles, each control switch to be fixed in each compartment with hinged door, bottom gland plate and locking arrangement consisting of sufficient Nos of circular cable entry holes at bottom only with suitable PVC/rubber/wooden bushes to prevent ingress of water/vermin etc, inside the enclosure, the required nos of holes to be fixed with chromium plated brass cable glands for cable entry and exit complete with necessary internal wiring with stranded copper conductor PVC insulated cables of adequate size, dulywith powder coated, painted one coat of red oxide primer and two coats of synthetic enamel paint of gray or any other approved colour and bus bar 200 Amps forphase & neutral 100 Amps capacity mounted on epoxy insulator-01 Set including comprising the following. |
| 63 | INCOMINGMCCB 4 pole,415 volt ,50 Hz , 100Amp of rupturing cap 25 KA -01 NoOUT GOINGMCCB 4 pole,415 volt ,50 Hz , 63Amp of rupturing cap 16 KA -02 NosMCCB 4 pole,415 volt ,50 Hz , 32 Amp of rupturing cap 16 KA -01 NoMCCB 4 pole,415 volt ,50 Hz , 20 Amp of rupturing cap 16 KA -01 NoMCB DP (6-40A) 230 Volt single ph,10KA-05 Nosdigital Volt, Ammeter& Freq Meter incl selector switch-01SetIndicator, danger board, line diagram,-01 Set |
| 64 | Material and labour for taking down carefully street light fitting and bracket for re use to serviceable after minor repairs if any by replacing wire, connection terminals and nut, bolt washers and fix the street light and bracket with steel tubular pole by using necessary clamps, nut bolts and washers complete all as specified and directed. Note: Clamps,nut,bolt and washers for fixing street light bracket is measured and paid separately with relevant items of the schedule |
| 65 | Supply and fix 1.5 sqmm 3 core, 1100 volt grade heavy duty cable, PVC insulated copper multistranded conductor, served with inner sheathing of PVC tape and overall PVC sheathed laid in proposed PVC conduit for making connection of street light from FRP junction box to street lights including provision of flexible pipe to concealed the copper wire from weather expose complete all as specified and directed by Engr-in charge. |
| 66 | Material and labour for Earthing for Panels complete with galvanized steel plate electrode of size 600x600x6.3mm thick buried directly in ground with earth pit not less than 2.25 meter deep below ground level with top edge of plate not less than 1.5 meter below normal ground level connected to galvanized iron earth wire 4mm dia earth lead by means of nuts, bolts, check nuts, washers of galvanised iron as steel,protected by galvanized iron pipe 40mm bore (Medium grade) allas directed including cement concrete (1:3:6) type C-1 earth pit with precast RCC (1:1.5:3) type A-1 cover slab of size 42 x 42 x10cm thick reinforced with 8mm dia TMT bars @ 15 cm c/c both ways with 10mm dia mild steel round bar of 30 cm long, bent to shape as lifting handle, funnel,wire mesh, 20 mm bore galvanized iron pipe (medium grade) for watering, charcoal or coke and salt in alternate layers with necessary earth work in soft/loose soil complete all as shown in electrical plate No 3 of SSR Part I including testing on completion all complete as specified and directed. |
| 67 | All as per serial item No.45 here in before but using galvanised iron strip 25×4mm as earthing lead complete all as specified and as directed. |
| 68 | Supply and install steel tubular swaged poles type 410 SP-31 ( 9.0 metres long) complete with CI based plate and finial includingpainting of poles with two coats of synthetic enamel paint over a coat of primer black and white/yellow strips 30CM wide each (05 Nos) up to 1.5 Mtrs height from coping & numbering of poles complete all as specified and directed. all as directed. Note: The existing old PCCPoles should be replaced with new steel rubber pole and the old pole is credited to Contractor as schedule of credit |
| 69 | Material and labour for 40mm dia steel tubes (light grade) galvanised with fittings, laid in trenches/wall for protection of underground earth strip when crossing the road/fixing on wall as in repair complete all as specified and as directed. |
| 70 | Material and labour for preparationold painted surfaces with synthetic enamel paint to LT steel tubular pole 8.5/9/8.0 mtr long including clamps,brackets,chanel,cross arms, bracing support, pipe of support for cable and swan neck etc including zebra painting at bottom up to 1.5 mtr above from the PCC coping and writing pole No with white paint complete etc complete all as specified and as directed.Note: Pole number shall be marked with white enamel paint over a base of size 20cmx20cm on prepared with two coats of black enamel paint on pole surfaces. |
| 71 | Material and labour for cement concrete in foundations, filling and mass concrete type D2 1:4:8 with 40 mm graded stone aggregate for foundation of pole etc complete all as specified and as directed. |
| 72 | Material and labour for providing PCC 1 : 3: 6 type C2 using 40mm graded stone aggregate as in foundations, filling and mass concrete complete all as specified and directed |
| 73 | Material and labour for providing cement concrete type B1, 1:2:4 using 20 mm stone aggregate in coping or chamfered on edges complete all as specified and as directed. |
| 74 | Supply and fix in repair hot moulded FRP looping /Junction box size 300x250 x105 mm for street light poles with locking arrangement and suitable connection for three phase incoming cable 3 phase out going cable and single phase connection for light fitting incl controlled MCB SP-10 Amps -01 Nos enclosed in thermo plastic in closed shock proof safe IP-65, weather, vermin proof, dust and water proof complete with two nos cables entry incl gland of standard size with suitable size mild steel clamps to fixed on pole complete all as specified.Make-Neptune/Hensel/Sintex |
| 75 | Material and labour for PCC preparation including cutting up to 45 cm width and depth of the road/hard standing and making good disturbed surfaces by using PCC type C2(1:3:6) by using 40mm graded stone aggregate for the fixing the pipe/laying cables complete all as specified and as directed. |
| 76 | Material and labour for 50mm dia steel tubes (light grade) galvanised with fittings, laid in trenches/wall for protection of underground earth strip when crossing the road/fixing on wall as in repair complete all as specified and directed. |
| 77 | Material and labour for 75 mm dia HDPE pipes PN 10 with fittings, laid in trenches/wall for protection of underground cable when crossing the road/fixing on wall complete all as specified and as directed. |
| 78 | Supply and fix LED type street light fitting 70 watt pressure dia cast aluminum housing LED street light luminaries with IP 66 including GI pipe medium grade with suitable size bracket bend in 120 degree and clamps,nuts,bolts etc with all accessories complete all as specified and as directed. |
| 79 | Material and labour for street light bracket made to shape from 40mm dia length 1.5m GI Pipe medium grade including two number of clamps made from 50mm x 6mm Flat iron nut bolts complete all as specified and as directed. |
| 80 | Excavation in trenches not exceeding 1.5 mtr wideand not exceeding 1.5 m in depth for taking out /for layingunder ground cables/pipes etc and getting out in soft/loose soil complete all as specified and as directed. |
| 81 | Removing excavated soil to a distance not exceeding 50 mtr and depositing where directed at a levelnot exceeding 1.5 mtr above the starting point complete all as specified and as directed. |
| 82 | Returning, filling in with excavated soil, including spreading, levelling, watering and well ramming in layers not exceeding 25cm complete all as specified and as directed. |
| 83 | Supply and laying unreinforced pre cast concrete cable cover class LV, Type I, flat, size 250mm x 150mm x 40mm for cable protection, made out of M-20 grade concrete, etc complete all as specified and as directed. |
| 84 | Relaying old serviceable unreinforced pre cast concrete cable cover class LV, Type I, flat, size 250mm x 150mm x 40mm for cable protection complete all as specified and as directed. |
| 85 | Supply & spreading fine river sand in trenches for cushioning of underground cable/filling of cable ductsall as directed by Engineer-in-Charge at site.Note :- Only punned Thickness shall be measured for payment purpose. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail