| Sl. No. | Item Description |
| 1 | Dismantling plain orcorrugated steel sheeting, with ridge, gutters, etc, any gauge, and thickness incl Nainital pattern roof covering, fixed with J/L hooks or coach screws complete all as specified and directed.Note: The work is required to be carried out in upto 15mtr height, contractor will make arrangement for scaffolding and other necessary T&P etc. Adequate arrangement for safety and security of labours shall be made by contractor and the cost of all above shall deemed to be included in the rates quoted by the contractor and nothing extra shall be admissible. |
| 2 | S&F pre-painted galvalume aluminium zinc coating GI based corrugatedsteel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.Note: The work is required to be carried out in upto 15m height, contractor will make arrangement for scaffolding and other necessary T&P etc. Adequate arrangement for safety and security of labours shall be made by contractor and the cost of all above shall deemed to be included in the rates quoted by the contractor and nothing extra shall be admissible. |
| 3 | S&F pre-painted galvalume aluminium zinc coating GI based Plain steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, eaves board fixed with self tapping screws, complete all as specified and directed.Note: The work is required to be carried out in upto 15m height, contractor will make arrangement for scaffolding and other necessary T&P etc. Adequate arrangement for safety and security of labours shall be made by contractor and the cost of all above shall deemed to be included in the rates quoted by the contractor and nothing extra shall be admissible. |
| 4 | Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories). incl necessary scaffoldingand other safety arrangement for heightup to 15mtr complete all as specified and directed. |
| 5 | S&FPlain, galvanised, mild steel sheeting of thickness 1mm as in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed) with grade of zinc coating 275 and joints are welded or soldered complete all as specified and directed.Note: The work is required to be carried out in upto 15m height, contractor will make arrangement for scaffolding and other necessary T&P etc. Adequate arrangement for safety and security of labours shall be made by contractor and the cost of all above shall deemed to be included in the rates quoted by the contractor and nothing extra shall be admissible. |
| 6 | Dismantling wrought iron or mild steel work of any description not otherwise provided, complete all as specified and directed. Note: The work is required to be carried out in upto15m height, contractor will make arrangement for scaffolding and other necessary T&P etc. Adequate arrangement for safety and security of labours shall be made by contractor and the cost of all above shall deemed to be included in the rates quoted by the contractor and nothing extra shall be admissible. |
| 7 | Dismantling timber scantlings ,framed/unframed work of size 40 sqcm and over in section ,in any position in any position with nails etc., complete all as specified and directed.Note: The work is required to be carried out in upto 15m height, contractor will make arrangement for scaffolding and other necessary T&P etc. Adequate arrangement for safety and security of labours shall be made by contractor and the cost of all above shall deemed to be included in the rates quoted by the contractor and nothing extra shall be admissible. |
| 8 | Dismantling timber scantlings framed work in fillets, frame work of cup board, rails, posts rafters, purlins,battens etc under 40 sq cm in sectionin any position with nails etc., complete all as specified and directed.Note: The work is required to be carried out in upto 20m height, contractor will make arrangement for scaffolding and other necessary T&P etc. Adequate arrangement for safety and security of labours shall be made by contractor and the cost of all above shall deemed to be included in the rates quoted by the contractor and nothing extra shall be admissible. |
| 9 | S&F rooftrusses,purlins, posts, crane gantries, rails and fastening and heavy bracket framing (Beam, tee, angle, channel, flat, tubular sections) including distance pieces cleats Fe 410-W (Gde-E- 250), quality-A etc complete for fixing roof sheets/ claddings and other similar works as per requirement complete all as specified and directed.Note: The work is required to be carried out in upto 15m height, contractor will make arrangement for scaffolding and other necessary T&P etc. Adequate arrangement for safety and security of labours shall be made by contractor and the cost of all above shall deemed to be included in the rates quoted by the contractor and nothing extra shall be admissible. |
| 10 | S&F framed work such as grills, gratings, etc., incl for ornamental and intricate design with ends of bars shouldered and/ or riveted, or forged into spikes, framed guard bars, barred iron doors, ladder, framed baluster, walk ways, railing, framework of water tanks staging and similar work conforming to Fe-290, Gde-E-165 complete all as specified and directed.Note: The work is required to be carried out in upto 15m height, contractor will make arrangement for scaffolding and other necessary T&P etc. Adequate arrangement for safety and security of labours shall be made by contractor and the cost of all above shall deemed to be included in the rates quoted by the contractor and nothing extra shall be admissible. |
| 11 | S&F welded steel wire fabric weight (n.exc 4kg) complete to wood or steel members etc complete all as specified and directed. |
| 12 | M&L for second class hard-wood wrought timber as in scantlings as in struts, tie beams, rafters,etc. framed and fixed complete all as specified and directed. |
| 13 | Taking down chowkhats or frames with shutters n.exc 1.5 sqm each (without taking off shutters from the frame) and removing from site complete all as specified and directed. |
| 14 | All as per Srl item No. 13.00 above but exc 1.5 sqm but n. exc 4 sqm each complete all as specified and directed. |
| 15 | S&F factory made single extruded WPC (wood polymer composite) solid plain flush door shutter of 30mmthick size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, complete all as specified and directed.Note: stainless steel butt hinges and necessary S S screws shall be paid separately. |
| 16 | S&F Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 45 x 70 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete all as specified and directed.Note: i) M.S. hold fast/ lugs or SS dash fasteners shall be paid for separately. ii) For WPC solid door/window frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made. complete. all as specified and directed. |
| 17 | S&F second class hardwood plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints complete all as specified and directed. |
| 18 | S&F 35mm thick, second class hard wood, glazed and skeleton shutters, open rebated and prepared to receive glass, gauze etcwith rails and styles including cut and mitered beards for securing wire cloth etc, complete all as specified and directed. |
| 19 | S&F 40mm flush shutters, solid core construction, with block board core and plywood face panels, commercial types on both sides incl one face covered with decorative face veneer with frame to matchincl teak wood beading around the shutters complete all as specified and directed. |
| 20 | S&F 100 mm sizebutt hinges, medium weight , coldrolled, mild steel and fixedcomplete all as specified and directed |
| 21 | S&F aluminium anodised barrel tower bolt 200mm long extruded section complete all as specified and directed. |
| 22 | S&F 150mm size extruded aluminium handles fabricated type anodised complete all as specified and directed. |
| 23 | S&F 250mm long aluminium alloy anodised sliding bolt with hasp and staple (bolt type) and fixing clips of sheet cast or extruded section and fixing bolts and sliding bolts and extruded section or cast aluminium alloy and fixed complete all as specified and directed. |
| 24 | S&F factory made uPVC of approved colour Three track three panels sliding window with fly proof S.S wire mesh (Two nos. glazed & one no. wire mesh panels) made of (big series) frame 116x45 mm & sash 46x62 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead/double glazing bead of appropriate dimension comprising of uPVC multi chambered frame, with inbuilt roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitered cut and fusion welded at all corners, including drilling of holes for fixing hardware\"s and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality and colour, complete all as specified and directed.Note: i) Glass or wire mesh shall be paid separately.ii)For uPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. |
| 25 | S&F factory made uPVC Casement door with 3D hinges made of (big series) frame 67x64 mm & sash 67x110 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of door upto 2.50 sqm) comprising of uPVC multi-chambered frame, sash and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, zinc alloy (white powder coated) 3D hinges and one handle on each side of panels along with zinc plated mild steel multi point locking having transmission gear, cylinder with keeps and one side key, G.I. fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws, etc. Profile of frame & sash shall be mitered cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware\"s and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality and colour complete all as specified and directed. Note: i) Glass shall be paid separately.ii) For uPVC frame, sash and mullion extrudedprofiles minus 5% tolerance in dimension i.e. indepth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. |
| 26 | S&F factory made uPVC of approved colour fixed glazed window/ventilator/partition made of (small series) frame 47x50mm mullion 47x68mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimensioncomprising of uPVC multi-chambered frame and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, G.I. fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame shall be mitered cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware\"s and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality and colour, complete all as specified and directed.Note: i) Glass shall be paid separately. ii) For uPVC frame, sash and mullion extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. |
| 27 | S&F stainless steel wire cloth, 0.56mm nominal dia of wire & average width of aperture 1.18mm with stainless steel wire staples complete all as specified and directed . |
| 28 | S&F 4mm thick tinted sheet glass and glazing with oil putty complete in squares of required size of each pane complete all as specified and directed. |
| 29 | S&F 5.5mm thick tinted sheet glass and glazing with oil putty complete in squares of required size of each pane complete all as specified and directed. |
| 30 | M&L for preparation of new steel surfaces and applying two coats of synthetic enamel paint on steel & iron surfaces of any description, not otherwise, described, over 10cm width or girth over one coat of red oxide, zinc chrome complete all as specified and directed. |
| 31 | M&L for applying one coat of synthetic enamel paint on steel & iron surfaces of any description, not otherwise, described, over 10cm width or girth including preparation of old painted surface complete all as specified and directed. |
| 32 | M&L for preparation of new wooden surfaces and applying two coats of synthetic enamel paint on wooden surfaces over a coat of primer of any description, not otherwise, described, over 10cm width or girth complete all as specified and directed . |
| 33 | M&L for preparation of old painted wooden surfaces and applying one coat of synthetic enamel paint on wooden surfaces of any description, not otherwise, described, over 10cm width or girth complete all as specified and directed. |
| 34 | S&F in repair drapery curtain rods Mild steel chromium plated with fixing brackets, side stop, rollers etc, complete all as specified and directed. |
| 35 | Demolition of brick work built in cement mortar incl all quoins, arches, pillars etc., complete all as specified and directed. |
| 36 | M&L for brick work with sub class \"B\" bricks old size bricks straight or curved on plan exc 6m mean radius built in CM 1:6, complete all as specified and directed. |
| 37 | M&L for 1/2 brick work with sub class \"B\" bricks, using old sizebricks, straight or curvedon plan exc 6 m mean radius built in cement mortar 1:4, complete all as specified and directed. |
| 38 | Taking down cement or cement lime plaster, grit plaster of any description on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc., complete all as specified and directed. |
| 39 | M&L for rendering 15mm thick plaster in CM 1:6, on brick orconcrete surface in cement mortar on Internal Wall Surface finished even and smooth without using extra cement, complete all as specified and directed. |
| 40 | M&L for rendering 15mm thick plaster in cement mortar 1:4 onbrick work or concrete surfaces on external wall surface finished even and fair without using extra cement mixed with WPC @ 200ml/ bag of cement, complete all as specified and directed.Note: WPC shall be measured and paid separately. |
| 41 | M&L for preparation of newly plastered surface on walls and applying two coats of oil bound distemper over a coat of 3mm thick wall care putty, complete all as specified and directed. |
| 42 | M&L for preparation of newly plastered surface of wallapplying two coats of weather proof anti fungal exterior emulsion paint on external surfaces includinga coat of alkali resistant priming paint with 2mm wall care putty at any height of building/ tower, complete all as specified and directed. |
| 43 | Dismantling of floor, hearth or wall tiling with cement mortar bedding, tucking and roughening of wall and floor, backingand dispose rubbish out off the premises, complete all as specified and directed. |
| 44 | Dismantling wall, ceiling and floor boards (fiber, pulp, insulation, etc) or insulation boards/slabs/blankets, any thickness, including cover fillets, GI grid/ wooden frame work, complete all as specified and directed. |
| 45 | S&F seasoned Pine Wood Ceiling using solid pine wood planks of minimum 8 feet length, having a thickness ofnot less than 12 mm and width of 100 mm to 150 mm, as per approved design. The pine wood shall be kiln-dried to a moisture content of 10–12% and shall be free from warping, cracks, sapwood, insect infestation, and knots larger than 10 mm. Planks shall be machine-planed on all sides with tongue and groove joints or shiplap joints, if specified and fixed over a pre-installed wooden or metal framework using approved screws, nails, or concealed fasteners. The ceiling shall be polished with two coats of PU polish of approved brand and shade over a base coat of wood sealer, including all sanding and surface preparation to achieve a smooth and uniform finish.Rate to include:(a)Supply of seasoned pine wood planks.(b)Surface treatment, polishing materials, and labor(c)Fixing hardware(d)Skilled labor, scaffolding, and all incidental worksNote: Framework will be paid separately. |
| 46 | M&L for 2nd class softwood plain fillets 25 sqcm square, rectangular or triangular in section, clean sawn, secured with nails or brads complete all as specified and directed. |
| 47 | M&L for providing and fixing calcium silicate ceiling board system having density 950-1200 Kg/cum which shall consist of high-quality calcium silicate boards, supported by a galvanized steel or aluminum suspension grid, suspended from the structural soffit using appropriate hangers and fixings. The system shall provide a durable, stable, and aesthetically pleasing finish. Calcium silicate boards should be ofsize 600x600mm, 12mm thick and Boards shall be free from defects, cracks, or chipsfixed with screw in a timber/ GI/ Aluminium frame work in flat or sloped ceiling as required, complete all as specified and directed. |
| 48 | M&L for GI frame powder coated work of size 605x605mm for seamless ceiling comprising of GI perimeter channel 0.55 mm thick with two unequal flanges of 20 and 30mm and web of 27mm fixed to surrounding wall using nylon sleeves and screws at 450mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx. 900mm centre to centre with GI cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457mm centre to centre, complete all as specified and directed. |
| 49 | M&L for hangers 6mm dia GI (upto 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40x3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified and directed. |
| 50 | S&F 4 mm veneered decorative teak plywood, grade 1(with BWR resin) with decorative face veneers on one faces, fixed with screws/adhesive solution to plywood/ flush door shutterand polished with two coats of PU polish of approved brand and shade over a base coat of wood sealer, including all sanding and surface preparation to achieve a smooth and uniform finish as in wall paneling complete all as specified and directed. |
| 51 | S&F 9mm plywood grade BWR type BB fixed with screw to timber frame as in wall paneling, complete all as specified and directed. |
| 52 | M&L for plain fillets exc 6 cm n exc 13 sqcm square, rectangular or triangular in section, clean sawn, secured with nails or brads complete all as specified and directed. |
| 53 | M&L for chamfers, splays, grooves, rebates, rounded angles, rounded nosing\"s, tongued and grooved edges (each tongue and each groove measured) etc., mouldings n exc 75mm girth on soft wood, complete all as specified and directed. |
| 54 | S&F insulated PVC wall lining (thickness of PVC wall lining 25mm) consisting of PVC insulated panels with wood grain printed PVC sheets havingexpanded polystyrene (EPS) stuck to 2mm thick plain colour PVC sheet duly fitted into the wall as per specifications and drawing, complete all as specified and directed. |
| 55 | M&L for dark shade/ double charged/ ultra charged vitrified tiles 10mm thick in floor exc 0.42 sqm but n.exc 1.00 Sqm each tile area set and jointed in neat cement slurry and pointed with white cement with pigment to match the shade of tile over and including screed bedding 15mm in CM 1:6 complete all as specified and directed. |
| 56 | All as per Srl Item No. 55.00 above but on vertical surface as in dados/ skirting over 10mm thick plaster as backing coat in CM 1:4 complete all as specified and directed. |
| 57 | M&L for colored digital light shade vitrified tiles 10mm thick in floor not exc 0.36sqm each tile area set and jointed in neat cement slurry and pointed with white cement with pigment to match the shade of tile over and including screed bedding 15mm in CM 1:6 complete all as specified and directed. |
| 58 | All as per Srl Item No 57.00 above but on vertical surface as in dados/ skirting over 10mm thick plaster as backing coat in CM 1:4 complete all as specified and directed. |
| 59 | M&L for non-skid colored ceramic tiles 7 to 8 mm thick, (square/ rectangular), area of each tile exceeding 0.11 sqm but nexc 0.18 sqm, in floors etc. set & jointed, with neat cement slurry and pointed white cement with pigment over 15mm thick screed bed or bedding layer of mortar in CM 1:6, for laying of tiles complete all as specified and directed. |
| 60 | M&L for glazed ceramic coloured digital wall tiles of size area exc 0.06Sqm and not exc 0.18 Sqm x 7-8mm thick set and jointed, including 10mm thick rendering in CM 1:4, mixed with PD proof 101 LW (+) of Dr fixitor equivalent integral WP admixer @200 ml/bag of cementfinished the surface even and fair, complete all as specified and directed. |
| 61 | Supply only PD proof 101 LW (+) of Dr Fixit or equivalent as approved, complete all as specified and directed. |
| 62 | Dismantling of reinforced concrete of any description and in any position not otherwise specifically provided for including cutting of reinforcement as required to facilitate demolition complete all as specified and directed. |
| 63 | M&L for reinforced cement concrete 1:2:4, (nominal mix), type B-0,using 12.5mm graded crushed stone aggregate as in Chajjas/ slab and the like complete all as specified and directed. |
| 64 | Use & waste of formwork to chajjas, slab, chullah hoods, troughs and similar items including edges rough finished surfaces complete all as specified and directed. |
| 65 | S&F of TMTbars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hookingends and binding with mild steelwire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and directed. |
| 66 | M&L for granite stone slab 18 to 19mm thick machine cut polished, bedded and jointed in neat cement slurry and pointed in white cement with pigment to match colour of granite stone with and including screed bed of 20mm thick in cement mortar 1:6 in walls, slabs, shelfs etc., complete all as specified and directed. |
| 67 | S&F of 15 mm bore tubes medium grade galvanised with and incl all GI fitting (such as bends, elbows, Tees, connectors, short pieces,back nuts, unions, caps and plug etc ) and fixed complete to wall and ceilingor laid in/on floor complete incl taking down old steel tubing 15 mm bore. all as specified and directed. |
| 68 | S&F of 20 mm bore tubes medium grade galvanised with and incl all GI fitting (such as bends, elbows, Tees, connectors, short pieces,back nuts, unions, caps and plug etc ) and fixed complete to wall and ceilingor laid in/on floor complete incl taking down old steel tubing 20mm bore complete all as specified and directed. |
| 69 | M&L for cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc., and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10 cm girth on stone walls complete all as specified and directed. |
| 70 | S&F in repair vitreous china wash down water closet pan (pedestal pattern), white incl seat cover (excluding flushing cistern & flush pipe) complete all as specified and directed. |
| 71 | S&F in repair vitreous china squatting pan, Orissa, pattern, size 580x440mm white with integral foot rest including trap set and including concrete complete including making good to floor etc (excluding flushing cistern and flush pipe) complete all as specified and directed. |
| 72 | S&F in repair PVC valve less, symphonic action type, flushing cistern 10 liter capacity, low level, white, with intel, ball valve, float & handle including flush pipe, brackets complete all as specified and directed. |
| 73 | S&F in repair vitreous china, wash hand basin with half pedestal , size 550x400x200mm including MS brackets including cutting and priming in with 32mm CP waste coupling, bottle trap/ 32mm waste pipe complete all as specified and directed. |
| 74 | S&F in repair centre hole CP basin mixer cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, mixing\"Hot\" or \"Cold\" water with long screwed shanks and fly nuts, screwed for iron pipe and fixed of bore dia 15mm complete all as specified and directed. |
| 75 | S&F in repair 15 mm dia Angle/ stop cock cast copper alloy, fancy type chromium plated screwed down high pressure, complete all as specified and directed. |
| 76 | S&F in repair 15mm bore CP bib tap fancy type long body cast copper alloy with capstan head handle screwed for iron pipe or for brass ferrule complete all as specified and directed. |
| 77 | S&F in repair 600x450mm beveled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washes complete all as specified and directed. |
| 78 | S&F single lever wall mixer with provision for overhead shower With 115mm long bend pipe on upper side, connecting legs & wall flanges, complete all as specified and directed. |
| 79 | S&F in repair of sheet glass shelf assembly consisting of 5.0mm thick sheet glass shelf 12cm wide with chromium plated bracketguard and railing 60cm long complete all as specified and directed. |
| 80 | S&Fin repair corner glass shelf with bracket 200mm radius, complete all as specified and directed. |
| 81 | S&F in repair 15 mm bore shower rose chromium plated ABS material of size 100x100mm square brass with \"L\" bend and PVC washers complete all as specified and directed. |
| 82 | S&F in repair CP hygienic spray (health faucet with 1.5M long tube) complete all as specified and directed. |
| 83 | S&F in repair PVC connection 15mm dia and 60 cm long with 2 Nos PTMT check nuts with washers complete all as specified and directed. |
| 84 | S&F 15mm dia CP kitchen sink mixture for mixing hot and cold water with regular spout without popup waste system, complete all as specified and directed. |
| 85 | S&F sinks with drainage board made of stainless steel 1mm thick kitchen or laboratory with plugs, washers & waste, including bedding in CM to dwarf wall or including fixing cantilever brackets & connecting union to pipe overall size 915x460mm bowl size 410x330x160mm complete all as specified and directed. |
| 86 | S&F waste fittings 40mm bore, brass, CP for glazed ware sinks, basins, etc. with long screwed shanks & fly-nuts, flange end bedded in red lead cement & other end fixed complete all as specified and directed. |
| 87 | S&F stainless steel plate rack made of 0.80 mm thick sheet of size 900x600x250mm complete all as specified and directed. |
| 88 | S&F in repair rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted & fixed in position all as specified in SSR Part-I, 500 Ltrs capacity complete all as specified and directed. |
| 89 | S&F 21-22 inch dia galvanised mild steel pan mortar (Tasla/ ghamela) not less than 1mm thick with for 04 Nos bolt of 5-6mm dia with 8Nos nut bolt with 8Nos washer including fixing on water storage tank as tank cover complete all as specified and directed. |
| 90 | S&F for PVC (SWR) pipes 110mm dia single socketed, in any length with rubber ring joints, laid in trenches complete all as specified and directed. |
| 91 | S&F PVC (SWR) pipes 110mm dia single socketed, in any length with rubber ring joints, fixed to wall, complete all as specified and directed. |
| 92 | S&F PVC \"P\" or\"S\" traps of 110 mm bore pipe complete all as specified and directed. |
| 93 | S&F PVC SWR cowl 110 mm bore pipe complete all as specified and directed. |
| 94 | S&F PVC (SWR) bends any radius 110mm complete all as specified and directed. |
| 95 | S&F for PVC (SWR) pipes 75mm dia single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed. |
| 96 | S&F for PVC (SWR) pipes 75mm dia single socketed, in any length with rubber ring joints, fixed to wall complete all as specified and directed. |
| 97 | S&F PVC (SWR) bends any radius 75 mm dia complete all as specified and directed. |
| 98 | M&L for 75mm dia PVC (SWR) floor trap plain with grating including jointing with solvent cement complete all as specified and directed. |
| 99 | S&F 100mm stack clamp out of 50mm by 5mm flat iron and 16mm dia around iron stamp incl bolts and nuts and securing ends of clamp to wall or roof complete all as specified and directed. |
| 100 | S&F CPGratings100mm dia complete all as specified and directed. |
| 101 | Cutting into existing manhole for connecting new drains making good to pipe and rendering,cutting out existing benchingfor and forming branch channel (1/2 or 3/4section ) in cement concrete 1:2:4, type B-1, using 20mm graded crushed stone aggregate finished smooth and reforming benching as required for 100mm dia pipes complete all as specifiedand directed. |
| 102 | Demolition of PCC in ground floors & pavings n exc 15cm thickness (below or above ground level)(unreinforced), complete all as specified and directed. |
| 103 | M&L for 75mm thick PCC 1:3:6, type C-2, using 20mm graded crushed stone aggregate as in plinth protection /path etc., complete all as specified and directed. |
| 104 | M&L for PCC 1:3:6, type C-2, using 40mm graded crushed stone aggregates cement concrete in surface channels and drains incl necessary formwork, complete all as specified and directed. |
| 105 | Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitered/ stopped ends etc complete all as specified and directed. |
| 106 | M&L for PCC 1:2:4, type B-0, using 12.5mm graded crushed stone aggregate for providing, cement concrete in roof kerbs or mud stops, rounded or chamfered on edges complete all as specified and directed. |
| 107 | Cutting holes in brick walls exc half brick but not exc one brick walls built in Cement mortar or cement lime mortarfor inserting holdfasts and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4, Type B-1, as required, complete all as specified and directed. |
| 108 | Dismantling cup board shelf, partition, wall paneling or similar items including shutter, insulation boards/ slabs/ blankets of any description, fixed in any position fixed with screws, complete all as specified and directed. |
| 109 | M&L for 18/19mm thick Block boards grade 2 quality, interior grade, decorative type with decorative face veneer on one face as in shelf for cup board, complete all as specified and directed. |
| 110 | M&L for 0.9mm thick decorative type-I, laminate of surface finish colour and pattern as approved, fixed with approved adhesive as per manufacturers instructions complete all as specified and directed. |
| 111 | S&F continuous (piano) hinges (width 30mm) mild steel, bright finish or electro galvanised, complete all as specified and directed. |
| 112 | S&F in repair 75mm size mild steel pressed handles, oval type, stove enameled black complete all as specified and directed. |
| 113 | S&F hasp and staple, mild steel, safety type of size 100mm including bolt to hinge plate and fixed with screws, complete all as specified and directed. |
| 114 | Excavating in post holes (or similar holes) each in Hard/ dense soil n exc 0.5 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers n. exc. 25cm, complete all as specified and directed. |
| 115 | M&L forPCC 1:4:8, Type D-2, using 40mm graded crushed stone aggregate as in foundations, filling and mass-concrete, complete all as specified and directed. |
| 116 | S&F steel work in tubular trusses, steel hollow sections etc including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161-1979 grade St.-240, complete all as specified and directed. |
| 117 | Taking down and refixing carefully copper/aluminum point wiring (light, fan socket or power) complete incl. (fitting such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc.), removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors etc, complete all as specified and directed. |
| 118 | Supply and install hi wall split units indoor/ outdoor complete withcordless remote control unit and with in built air ionizer and plasma filter for better indoor air quality with minimum 4 star rating and EER 3.2 of capacity as shown, complete all as specified and directed. |
| 119 | S&F of visiaro round soft copper tube, 7.5mtr, outer dia 1/4 inch, wall thickness 25 swg, seamless hollow pipe coil for air conditioners, refrigeration, plumbing systems and DIY projects, complete all as specified and directed. |
| 120 | S&F of visiaro round soft copper tube, 7.5mtr, Outer Dia 1/2 inch, wall thickness 23 swg, seamless hollow pipe coil for air conditioners, refrigeration, plumbing systems and DIY projects, complete all as specified and directed. |
| 121 | S&F GLUN ® leakage repair waterproof tape for pipe leakage solution aluminum foil tape adhesive tape sealing butyl rubber tape for surface crack, complete all as specified and directed. |
| 122 | S&F of one 3 pin socket outlet, 15 Amps, independent, with cables 4sqmm, completed all as specified and directed. |
| 123 | S&F havells DBOXx, MCB protected socket PVC plastic, completed all as specified and directed. |
| 124 | S&F sheet metal enclosure MCB DB, 12 way, SPN double door, suitable for 240 V, 200 amps rated bus bar/ DIN rail, fixed and flushed on walls including cutting Knitch and making good disturbed surfaces, complete all as specified and directed. |
| 125 | S&F MCB, SP (single pole) 05 to 32 Amps, 10 kA, B curve for inductive load connected through cable lugs of suitable size complete all as specified and directed. |
| 126 | S&F MCB, SPN (single pole and neutral) 40/ 63 Amps for inductive load connected through cable lugs of suitable size complete all as specified and directed. |
| 127 | S&F MCB, TPN (Triple pole Neutral) 40/ 63 Amps for inductive load connected through cable lugs of suitable size complete all as specified and directed. |
| 128 | S&F sheet metal enclosure MCB DB 4 way, VTPN double door suitable for 240 V, 200 amps, rated bus bar/ DIN rail, fixed and flushed on walls including cutting Knitch and making good disturbed surfaces, complete all as specified and directed. |
| 129 | S&F 4 Pole, MCCB 63 Amp, 50 Hz, 415 V with rupturing capacity 25 KA connected through cable lugs of suitable size complete all as specified and directed. |
| 130 | M&L for sub main wiring with 2x6.0Sqmm+1x6.0 Sqmm earth wire single core PVC insulated FRLS-H, PVC sheathed cooper cableconnecting to common earth dolly in and including heavy duty PVC casing cappingas per site requirement and direction by EIC, with all accessories complete all as specified and directed. Note: Three runs of copper wire for phase, neutral, earth & one run PVC conduit/ casing shall be measured one unit length. |
| 131 | Supply and laying Aluminium strip 25 x 3.15mm with saddles and fixing screws etc. for roof conductors and down conductors above ground, complete all as specified and directed. |
| 132 | All as per Srl item No 131.00 above but for 32x6 mm galvanized iron strip complete all as specified and directed. |
| 133 | S&F Air termination, single pointed aluminium rod 12mm dia and 300mm long, complete all as specified and directed. |
| 134 | S&F test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw, complete all as specified and directed. |
| 135 | S&F Galvanized zinc metallic zinc coated Iron earthing electrode specialized developed for high sensitive equipment. Model SN001 (LXXVI MM) as per Cpri 300cm long. Tested on 52 kA, C% 12 max, mn 0.60%mm class type GALV. Yield strength 329, tensile Strength 426, elongation bend/ flattering. Thickness Internal disposes\" 2 inchx6mm with base plate 3.15 to close the earthing rod. Terminal 2 inchx6mm filled with highly conductive compound which increase the life of earthing electrode. Composition of chemical filled in electrode water solubility. Grain size 100 mesh, along with SN make BFC compound non toxic, non reactive, non explosive and non corrosive, longer life easy to maintain less space consistent results. Earthing pit and chamber cover, complete all as specified and directed. Make: SN ENGINEERING or equivalent as approved. |
| 136 | M&L for PVC trunking for cable s and wires of suitable size complete all as specified and directed. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
| 5 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail