| 1 | Taking down of existing LT panel and Supply, installation, testing and commissioning of new LT Panel board, (CPRI type tested) factory made cubical type, Outdoor type, floor mounted, factory made out of 50mmx50mmx6mm angle iron frame and3.15mm innerCRCA steel sheet side covers with front and back hinged doors with proper locking arrangement, rubber gasket on front and back to make it dust and vermin proof, powder coated including suitable rated aluminium bus bar sleeved with heat shrink sleeve colour coated for 3 Phase, 4 wire electricsupply system and wiring with suitable size of 600 amps(03 Nos 600 Amps for Phase and 01 No 600 Amps for neutral) rated aluminiumbus bar complete powder coated paintwithand providing necessary foundation/plateform of the feeder pillar and provision for incoming and outgoing cable, cable gland, replacement of lugs for existing cables as per site requirement and proper finshing as per existing surface complete all as specified and directed by Engr- in- Charge.Note : (i) The quoted rate shall be of all inclusive.(ii) Drawing for LT panel shall be got approved by GE before fabrication.(iii)Platform for the feeder pillar board with PCC 1:2:4 150mm thick in foundation, Brick (Sub Class B)work inCM 1:6 ,rendering 1:6 on exposed surfaces 10mm thick and 100 mm thick PCC 1:3:6 type C1 using 20 mm graded stone aggregate as in padding on top and grouting legs of panel . The platform shall be of 40 cm below ground level and 60Cm height above ground level . Rate forPlatform shall be included in the quoted rate.(a) Incoming(i) MCCB 04 Pole 36 kA, 400 Amp,415 Volts, fixed thermal & magnetic release(Qty 01 No). (b) Out goings(i) MCCB 04 Pole 26 KA, 250 Amp,415 Volts,fixed thermal & magnetic release (Qty - 02 Nos) (ii) MCCB 04 Pole 25 KA, 200 Amp,415 Volts,fixed thermal & magnetic release (Qty - 01 Nos) (iii) MCCB 04 Pole 16 KA, 63 Amp,415 Volts,fixed thermal & magnetic release (Qty - 01 Nos) (iv) Aluminiumbus bar suitable size 3 phase, 4 wire 600 Amp,415 V, duly insulated - set of 4(v) Digital Volt meter 0-500V with slector switch.(vi)Digital Amp meter 0-400 amp with CT 400/5A and selector switch.(vii) Indicating lamp (RYB)LED Type - set of 3 |
| 2 | Taking down of existing LT panel and Supply, installation, testing and commissioning of new LT Panel board, (CPRI type tested) factory made cubical type, Outdoor type, floor mounted, factory made out of 50mmx50mmx6mm angle iron frame and3.15mm innerCRCA steel sheet side covers with front and back hinged doors with proper locking arrangement, rubber gasket on front and back to make it dust and vermin proof, powder coated including suitable rated aluminium bus bar sleeved with heat shrink sleeve colour coated for 3 Phase, 4 wire electricsupply system and wiring with suitable size of 400 amps(03 Nos 400 Amps for Phase and 01 No 400 Amps for neutral) rated aluminiumbus bar complete powder coated paintwithand providing necessary foundation/plateform of the feeder pillar and provision for incoming and outgoing cable, cable gland, replacement of lugs for existing cables as per site requirement and proper finshing as per existing surface complete all as specified and directed by Engr- in- Charge.Note : (i) The quoted rate shall be of all inclusive.(ii) Drawing for LT panel shall be got approved by GE before fabrication.(iii)Platform for the feeder pillar board with PCC 1:2:4 150mm thick in foundation, Brick (Sub Class B)work inCM 1:6 ,rendering 1:6 on exposed surfaces 10mm thick and 100 mm thick PCC 1:3:6 type C1 using 20 mm graded stone aggregate as in padding on top and grouting legs of panel . The platform shall be of 40 cm below ground level and 60Cm height above ground level . Rate forPlatform shall be included in the quoted rate.(a) Incoming(i) MCCB 04 Pole 25 kA, 250 Amp,415 Volts, fixed thermal & magnetic release(Qty 01 No). (b) Out goings(i) MCCB 04 Pole 26 KA, 200 Amp,415 Volts,fixed thermal & magnetic release (Qty - 01 Nos) (ii) MCCB 04 Pole 16 KA, 63 Amp,415 Volts,fixed thermal & magnetic release (Qty - 03 Nos) (iii) Aluminiumbus bar suitable size 3 phase, 4 wire 400 Amp,415 V, duly insulated - set of 4(iv) Digital Volt meter 0-500V with slector switch.(v)Digital Amp meter 0-250 amp with CT 250/5A and selector switch.(vi) Indicating lamp (RYB)LED Type - set of 3 |
| 3 | Taking down of existing LT panel and Supply, installation, testing and commissioning of new LT Panel board, (CPRI type tested) Factory made cubical type, Outdoor type, floor mounted, factory made out of 50mmx50mmx6mm angle iron frame and3.15mm innerCRCA steel sheet side covers with front and back hinged doors with proper locking arrangement, rubber gasket on front and back to make it dust and vermin proof, powder coated including suitable rated aluminium bus bar sleeved with heat shrink sleeve colour coated for 3 Phase, 4 wire electricsupply system and wiring with suitable size of 300 amps(03 Nos 300 Amps for Phase and 01 No 300 Amps for neutral) rated aluminiumbus bar complete powder coated paintwithand providing necessary foundation/plateform of the feeder pillar and provision for incoming and outgoing cable, cable gland, replacement of lugs for existing cables as per site requirement and proper finshing as per existing surface complete all as specified and directed by Engr- in- Charge.Note : (i) The quoted rate shall be of all inclusive.(ii) Drawing for LT feeder piller box shall be got approved by GE before fabrication.(iii)Platform for the feeder pillar board with PCC 1:2:4 150mm thick in foundation, Brick (Sub Class B)work inCM 1:6 ,rendering 1:6 on exposed surfaces 10 mm thick and 100 mm thick PCC 1:3:6 type C1 using 20 mm graded stone aggregate as in padding on top and grouting legs of panel . The platform shall be of 40 cm below ground level and 60Cm height above ground level . Rate forPlatform shall be included in the quoted rate.(a) Incoming(i) MCCB 04 Pole 25 kA, 200 Amp,415 Volts, fixed thermal & magnetic release(Qty 01 No). (b) Out goings(i) MCCB 04 Pole 16 KA, 100 Amp,415 Volts,fixed thermal & magnetic release (Qty - 01 Nos) (ii) MCCB 04 Pole 16 KA, 63 Amp,415 Volts,fixed thermal & magnetic release (Qty - 02 Nos) (iii) Aluminiumbus bar suitable size 3 phase, 4 wire 300 Amp,415 V, duly insulated - set of 4(iv) Digital Volt meter 0-500V with slector switch.(v)Digital Amp meter 0-500 amp with CT 200/5A and selector switch.(vi) Indicating lamp (RYB)LED Type - set of 3 |
| 4 | Taking down of existing LT panel and Supply, installation, commisioning and testing of new LT panel out door typedouble door and single shutter front open including locking arrangement system made out of MS sheet of 3.15 mm CRCA sheet of size 0.9x0.9x0.3 mtr and double door,canopy,dust proof, bottom cable entry plate and gland for cable size150/120/95/70/50/25/16/10 sqmm 3.5 core suitableMS angle iron 50x50x6 mm with aluminium busbar size 400Amps with Incoming MCCB 250 Amp 4 pole systemmounted on hygroscopic insulators bus bar includingsuitable nut, Bolt and Washer(16 Nos) , & including powder coated paintwithand providing necessary foundation/plateform of the feeder pillar legs size 40cm below the ground and 60 cm above the ground completefrom groundwith PCC 1:2:4 type B2 including provision of for incomong and outgoing cable gland, thimbling for old / new cables as per site requirement and proper finshing as per existing surface complete all as specified and directed by Engr- in- Charge.Note: Drawing for LT feeder piller box shall be got approved by GE before fabrication.(i) Incoming : MCCB 04 Pole 26 KA, 250 Amp,415 Volts,fixed thermal & magnetic release (Qty - 01 Nos)(ii) Aluminiumbus bar suitable size 3 phase, 4 wire 400 Amp,415 V, duly insulated - set of 4(iii) Digital Volt meter 0-500V with slector switch.(iv) Digital Amp meter 0-400 amp with CT 250/5A and selector switch.(v)Indicating lamp (RYB)LED Type - set of 3 |
| 5 | M&L for replacement of XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured heavy duty electric power cable 1100 volts with stranded aluminium conductor of size 185 Sqmm 3.5 core laid in trenches or under road complete all as specified and as directed. (Note: Excavation, cable protection work will be measure & paid separately) |
| 6 | All as per serial item No 5.00 above here-in- before but of size 120 Sqmm 3.5 core complete all as specified and directed by Engr- in- Charge. |
| 7 | All as per serial item No 5.00 above here-in- before but of size 95 Sqmm 3.5 core complete all as specified and directed by Engr- in- Charge. |
| 8 | All as per serial item No 5.00 above here-in- before but of size 25 Sqmm 4 core complete all as specified and directed by Engr- in- Charge. |
| 9 | Supply,laying & fixing double wall corrugated (DWC) pipes made of high density polythyline (HDPE) with all accessories i.e. all type of joints,Sockets,Elbows,bends and End caps as size of DWC pipe is 40mm O/D and 32 mm Inner dia complete all as specified and directed by Engr in Charge. |
| 10 | All as per srl item No 9.00 above here-in-before but of size 77mm outer dia and 63mm inner dia complete all as specified and directed by Engr- in- Charge. |
| 11 | All as per srl item No 9.00 above here-in-before but of size 90mm outer dia and 76mm inner dia complete all as specified and directed by Engr- in- Charge. |
| 12 | Excavation in trenches n .exc 1.5 mtr wide and not exec 1.5 mtr in depth for foundation etc or for laying pipe lines and cables and getting out as in looses/soft soil complete all as specified and directed by Engr- in- Charge. |
| 13 | Returning filling in including spreading leveling, watering and well ramming in layer not exe. 25 cm in soft/ loose soil, complete all as specified and directed. |
| 14 | Removing excavated material to a distance not exc 50m and depositing where directed at a level n.exc 1.5 mtr above the starting point complete all as specified and directed by Engr- in- Charge. |
| 15 | M&L for earthing complete with galvanized iron or steel plate electrode 600 mm x 600 mm x 6.00 mm thick buried directly in ground vertically in pit of depth not less than 2.25 metre below normal ground level with top edge of the earth plate at a depth not less than 1.5 metre below normal ground level surrounded from all sides with mixture of charcoal andcommon salt in alternate layers and electrode connected to galvanized iron strip 32 x 6 mm dia as earthing lead by means of GI bolts, nuts, check nuts and washers, earth strip protected by galvanized steel pipe 40 mm bore (light grade) connected to machinery/ equipment all as shown in electrical plate No. 3 of SSR-2010 Part I and including necessary excavation and earth work in any type of soil, 20mm bore light grade GI pipe for watering, funnel, wire mesh, PCC (1:3:6) type C-1 chamber, MS cover of thickness 5mm openable type and having suitable locking arrangementand MS frame of suitable size made of angle iron 50 x 50 x 60 mm, complete all as specified and directed by Engr- in- Charge. Note: (i) The unit rate includes earth lead and protection pipe up to maximum 7.5 metre from earth plate to earth point/test point. (ii) Earth pit shall be constructed minimum 0.5 metre away from earth. |
| 16 | Supply and laying GI steel tubing, 80mm bore, light grade with all fittings, laid in trenches / under roads / along pole / wallfor protection ofCable / GI wire / GI strip etc complete all as specified and directed. |
| 17 | All as per ser item No 16.00 above here-in-before but size 50mm complete all as specified and directed. |
| 18 | M&L for Boring of holes under road, pavement, hard standing by trenchless ultra sound technology/mannual all as per site requirment complete all as specified & directed. |