| 1 | Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5m depth for laying under ground cable/pipes in loose/soft soil all as specified and directed. |
| 2 | All as per the description of srl item No 01 here-in-before but Hard/dense soil. |
| 3 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm all as specified and directed. |
| 4 | Removal of surplus soil obtained from excavated material not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point all as specified and directed. |
| 5 | M&L for sand cushioning for protection of cables with screen wash river sand and punning to proper required cover all as specified and directed. |
| 6 | M&L for bricks of sub class ‘B’ bricks, for cable protection in trenches laid dry and flat all as specified and directed. |
| 7 | Supply, laying, jointing, testing and commissioning in replacmentLT underground cables 1100 volts grade, PVC insulated XLPE and PVC sheathed, heavyduty armoured, with multistranded aluminium conductors 10 sqmm 2 core laid in trenches, fixed to pole/wall incl taking down unsv complete any size,type&core complete all as specified and directed. Note:- Earth work,cable protection,sand fillings,cable joint shall be measured and paid separately. |
| 8 | All as per the description of srl item No 07 here-in-before but 16 Sqmm 4 Core. |
| 9 | All as per the description of srl item No 07 here-in-before but 35 Sqmm 3.5 Core. |
| 10 | All as per the description of srl item No 07 here-in-before but 50 Sqmm 3.5 Core. |
| 11 | All as per the description of srl item No 07 here-in-before but 70 Sqmm 3.5 Core. |
| 12 | All as per the description of srl item No 07 here-in-before but 120 Sqmm 3.5 Core. |
| 13 | M&L for painting of LT electric pole, steel tubular swaged pole (9 mtr long) of any size, any pattern with one coat of aluminium paint over a coat of red oxide primer in full length of the pole and marking the pole with black and yellow strip (upto to 1.50 mtr length, 1.50 mtr height of PCC coping) alternatively including numbering the pole serially all as directed . |
| 14 | M&L for high intensity retro reflective sheet 5cm width length up to 60 cm length as specified colours with heavy duty self adhesive tape for stick on electrical pole complete all as specified and directed. |
| 15 | M&L for disconnecting of all elecric supply, taking out electric incoming and out going cables from existing LT feeder piller of any size and any type,powder coated painting in inner & outer side complete over a cleaning, scrabing with salt paper and removal of dust particles complete with necessary T&P, and refixing the same as incoming and outgoing cables as existing complete all as specified and directed. |
| 16 | S&F in repairs for loop box out door type made out of FRP type body one piece moulding type,Bus bar rating 63 Amps 4 strips aluminium with bus bar mounting colour R,Y,B,N on DMC unbreakable insulator with cable entry main supply from bottom side and pole light connection from back side, simens grey colour, shock prrof, rust proof, fire retardantsize approx 300x 200x 100mm with 6/10 Amps MCB SP, having front, opening and locking arrangement, duly fixed on the pole by MS clamp of suitable sizes, all as specified and directed. Note:- Incoming and outgoing cables suitable size Lugs,Glands rate deemed to be included) |
| 17 | All as per the description of srl item No 16 here-in-before but Single phase system 2 strips aluminium bus bar size of approx 200x150x100mm all as specified and directed. |
| 18 | Labour for cutting and removing grass, vegetation bushes etc from surrounding HT installation/LT Panel/Four Pole structure/Sub Stations and removing all rubbish to a distance not exceeding 30 m as directed. |
| 19 | Labour for trimming of tree branches around the street/security light poles (not less than 2 mtrs) to clear the vegetation including cleaning of nest of birds, creepers on poles and stays etc complete removing and disposed off from the site complete all as specified and directed. |
| 20 | M&L for replacement of lock assembly with key of old/existing LT panel board any type/size complete all as directed |
| 21 | M&L for replacement of door/MS sheet of old/existing LT panel board any type/size with cutting, welding & bend to shape and spray painting with powder coated paint with smoke grey paint in outer/inner side over one coat of primer after complete all as directed |
| 22 | M&L for replacment of double compression stainless steel glandsuitable size for 16/25 sqmm 3.5/4 core LT power cablesincl restore of electric connection completeall as directed. |
| 23 | All as per the description of srl item No 22 here-in-before but35 to 50 sqmm 3.5 core LT cable |
| 24 | All as per the description of srl item No 22 here-in-before but70 to 120 sqmm 3.5 core LT cable |
| 25 | S& F in replacementofDecorative LED 30 Watt Lamp type, Cast iron pole with base plate of 3 mtr height with die cast aluminiumlighting fixture, polycarbonate diffuser, sillicon rubber gaskat, stainless steel screws, corrosion and UV rays resistant coating and IP 65/66 including of brick/PCC workas recommend by the manufacturer allasspecified and directed and connecting up with and includingprovision of PVC insulated copper conductor cable 1.5 Sqmm, 2/3 core as required for connections complete all as specified and directed. |
| 26 | M&L for writing letters or figures (Block, Roman, Italic or Indian) n exc. 30 cm high with synthetic enamel paint as per colour scheme complete all as specified and directed. |
| 27 | Material and labour for disconnecting faulty/burnt spreaders 3 pole/4 pole up to 400 amps MCCB rating in existing panel board and replace with suitable set of spreaders (03/04 Nos) complete all as directed. |
| 28 | Material and labour for disconnecting rotary handle direct type with accessoriesup to 400 amps MCCB rating in existing panel board and replace with same complete all as directed. |
| 29 | S&F in replacement of MCCB, 4 pole, 415V AC, 63Amps with breaking capacity 16kA, fixed/adjustable typeincluding suitable spreaders of complete. |
| 30 | All as per the description of srl item No 29 here-in-before but 100 Amps with breaking capacity 16kA |
| 31 | AAll as per the description of srl item No 29 here-in-before but 125Amps with breaking capacity 16kA |
| 32 | Demolition of cement concrete of any description and in anyposition complete all as specified and directed. |
| 33 | M&L for PCC (1:4:8) type D2,( using 40 mm graded aggregate) as in foundations, filling and mass concrete Complete all as specified and directed. |
| 34 | M&L for PCC (1:3:6) type C1, (Using 20 mm graded aggregate) as in foundations, for coping, filling and mass concrete with cement plastering fair finishing all as specified and directed. |
| 35 | M&L for Cutting of road/path for laying of GI tubing and making the good to disturbed road/ path including provision of PCC 1:2:4 type B-1 using 20mm graded stone aggregate all as specified and directed. |
| 36 | M&L for steel tubes, light grade galvanised 80 mm borelaidin trenches/walls and spreading for cable cushioning/protection all as specified and directed incl taking down old unsv complete. |
| 37 | All as per the description of srl item No 36 here-in-before but 50 mm bore. |
| 38 | M&L for street light bracket suitable for street/security light fittings upto 1.5 RM make out of GI pipe of light grade up to 40 mm dia proper shaped, bended, threaded and drilling holes for wire entry and MS clamp of suitable sizein proper shape and designedincluding taking down old corroded one all as directed and specified . |
| 39 | M&L for repairs in PVC, sheathed copper cable of2.5 sqmm, 3 core for street light connection including taking down unserviceable PVC insulatedaluminium conductorcablefromsteel pole /PCC pole /Jn box all as specified and directed. |
| 40 | S&F in repairs for street light LEDluminaries with low wattage with pressure die cast aluminium housing, with heat resistant thoughened glass & IP 66 protection and 45 Watt including taking down old unserviceable one all specified and directed |
| 41 | S&F in repairs for street light LED luminaries with low wattage with pressure die cast aluminium housing, with heat resistant thoughened glass & IP 66 protection and 60 Watt including taking down old unserviceable one all specified and directed . |
| 42 | Supply and fixing in repair LED flood light fitting 70 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65 protection complete. pre-wired incl connecting up with PVC insulated copper conductor cable 1.5 Sqmm, 3 core as required for connections and 50 mm bore light grade G. I. tube mounting bracket of 1.5 meter in length, bend to shape at 140 degree in ‘L’ shape and fixed to wall by means of 02 nos. of 40 x 5 mm flat iron clamps, nuts, bolts & washers complete. |
| 43 | All as per the description of srl item No 42 here-in-before but 100 watt |
| 44 | All as per the description of srl item No 42 here-in-before but 120 watt |
| 45 | S&F in repairs for decorative LED post top fittings 25W Ruby Clear/Coral opal type IP 65 including with all accessories complete along with after taking down old unserviceable one all specifiedNote: light grade GI pipe and necessary PCC works included in quoted rate) |
| 46 | All as per the description of srl item No 45 here-in-before but 45 watt |
| 47 | S&F in repairs for garden light fitting 10 watts, IP65 rated Inverted Pyramid Tripod type LED Bollardwith soft 360 deg light distribution (crompton LBLSN 10 CDL type) including taking down old fitting, demoliton of brick/PCC work all as specified and directed. Note: Necessary PCC works rates included in quoted rate) |
| 48 | S&F in repairs for LED type IP 66, bush light with die cast aluminium having with toughened glass 9 W incl fixing arrangements complete all as specified and directed. |
| 49 | Taking down defective street light fitting/flood lights any wattage, make,model from pole and repair the same including replacement of defective/faulty LED driver and re-fixing the same incl connection complete all as directed |
| 50 | Removal of UNSV PCC/Steel pole and M&L for steel tubular swaged poles complete with cast iron base plate final taper plug bolts/swan neck type nuts & screw all as specified and directed Type 410 SP 31 (9 Mtr long) with two coat of aluminium paint over a coat of red oxide primer in full length of the pole with black and yellow strip up to 1.5 mtr over PCC coping alternatively including numbering the pole and necessary excavation incl dismantling the unserviceable pole with fittings etc complete.Note: Excavation, demolition of concrete, PCC for foundation, coping and connected items shall be measured and paid separately under relevant items) complete all as specified and directed. |
| 51 | S&F in repairs of LT panel Voltmeter digital type for 415 Volts, 3 phase system, rating 0-500 V complete suitable for operation of LT Panel all as specified and directed. |
| 52 | S& F in repairs of LT panel Ammeter digital type for 415 Volts, 3 phase system, rating 0-200 A complete suitable for operation of LT Panel all as specified and directed. |
| 53 | S&F in repairs of LT panel Ammeter digital type for 415 Volts, 3 phase system, rating 0-400 A complete suitable for operation of LT Panel all as specified and directed. |
| 54 | M&L for checking of earthpit results, cleaning pit area complete, pouring of salt water as reqd in pit for maintaning of pit resistance up to less than 5 ohm complete all as specified and directed. |
| 55 | S&F in repair industrial type TPN enclosure with a three pin and neutral and earth plug and socket complete with and including 63 Amps MCB, four pole, AC, 415 volts and flush to wall including all cuttings & chases etc in wall and making good to the disturbed surfaces to match the existing complete |
| 56 | All as per the description of srl item No 55 above but with and including 32 Amps MCB, four pole, AC, 415 volts |
| 57 | All as per the description of srl item No 55 above but with and including 20 Amps MCB, four pole, AC, 415 volts |
| 58 | Repair of earth pit incl required exacavation, earth work and PCC work to make good damaged/disturbed surfaces of earth pit chamber & making new pit cover of RCC 1:2:4 type B-1 using 20mm graded stone aggregate reinforced and lifting handle on RCC cover with 8 mm MS bars at 150 mm centre to centre both ways incl supply & fixing of wire mesh and funnel including re-connection of earth wire/strip with panel/transformer using GI nut, bolts & washer complete all as specified & directed |
| 59 | Material & labour for earthing in repair with Galvanised Steel earth plate electrode 60cmx 60cm x 6mm thick buried directly in ground vertically at a depth not less than 2.25metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below normal ground level, earth plate surrounded from all sides by 15cm thick packed layer ofcharcoal dust and common salt filling in alternate layers and electrode connections by usingGalvanised Iron wire of 4 mm dia as earthing lead(upto the body ofthe equipment) by means ofbolts, nuts, check nuts and washers made of galvanised iron and thimbles and protected by light grade 40mm diaGI pipe connected to main switch board or main control board and GI pipe medium grade 20mm bore for watering and including funnel , wire mesh , RCC pit cover and PCC chamber pit with PCC (1:3:6)type C-2 using 40mm graded stone aggregate, including excavation and earth work in any type ofsoil , returning , filling in approved soil and disposal of surplus soil to a distance not exceeding 50m all as specified and shown in electrical plate No 5 ofSSR 1991(Part-I) complete all as specified and directed . |
| 60 | All as per the description of srl item No 59 but using with Galvanised Iron strip of size 25 X 4mm as earthing leadcomplete all as specified and as directed. |
| 61 | All as per the description of srl item No 59but using with copper earth plate electrode 60cmx 60cm x 3.15 mm andcopper strip of size 20X3 mm as earthing leadcomplete all as specified anddirected. |
| 62 | Supply and fixing earth continuity conductor or main earth lead fixed to wall on batten or recess or chess or buried in ground drawn in conduit/pipe or fixed to the pole or any other situation for loop earthing etc as required 20x3mm copper strip all as specified and directed. |
| 63 | Supply and fixing earth continuity conductor or main earth lead fixed to wall on batten or recess or chess or buried in ground drawn in conduit/pipe or fixed to the pole or any other situation for loop earthing etc as required 25x4mm GI strip all as specified and directed. |
| 64 | Supply, install, testing and commissioning(In repair) of factory made LT panel outdoor type of size not less than 270 cm x 65 cm x 220 cm for 3 phase 415 Volts outdoor type cubical compartmentalised vermin and water proof fabricated out of 3.15mm thick CRCA sheet powder coated front and back door openable with locking arrangement, necessary ventilation,suitable for including 200 Amps rated aluminium bus bar for 3 phase system insulated with PVC sleaves and coloured with (Red, Yellow, Blue and Black) CTR and internal wiring with suitable size of PVC insulated copper wire, use with angle iron 60cmx60cmx6mm frame bottom of the panel board, 0.6 mtrs length legs(04Nos) grouted by using PCC foundation 1:3:6 type C1 using with 20mm graded stone aggregate, aluminium thimbling and cable entry boxes with cable glands including painting with two coat of powder coated painting over a coat of red oxide primer after dismanteling the existing unsv LT panel complete with following incoming/out going accessories:-IN COMING(a) MCCB 4 Pole, 415 volts, 500 Amps 36 KA, adjustable type- 01 Nos, OUT GOINGS (a) MCCB 4 Pole, 415 volts, 350 Amps 36 KA- 02 Nos(b) MCCB 4 Pole, 415 volts, 160 Amps 36 KA- 02 Nos (c) MCC, DP, 63 Amps 16 KA -01 Nos (d) Ampere meter (digital type) 0-250 Amps with selectro switch- 01 No (e) Volt meter (digital type) 0-500 volts with selector switch- 01 No (f) Indicator lamp (set of 3)- 01 set (g) Danger notice plate vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour (h) Provison of 02 Nos earthing terminals etc complete. |
| 65 | Supply, install, testing and commissioning(In repair) of factory made LT panel outdoor type with canopy of size not less than 200cm x 44 cmx 140 cm for 3 phase 415 Volts outdoor type cubical compartmentalised vermin and water proof fabricated out of 3.15mm thick CRCA sheet powder coated front and back door openable with locking arrangement, necessary ventilation, provision for cables side entry suitable for including 200 Amps rated Al bus bar, insulated with PVC sleaves and coloured with (Red, Yellow, Blue and Black) CTR and internal wiring with suitable size of PVC insulated copper wire, use with angle iron 60x60x6mm frame bottom of the panel board, 0.6 mtrs length legs(04Nos) grouted by using PCC foundation 1:3:6 type C1 using with 20mm graded stone aggregate, thimbling and cable entry boxes with cable gland including painting with two coat of powder coated painting over a coat of red oxide primer after dismanteling the existing LT panelcomplete with following incoming/out going accessories:-IN COMING (a) MCCB 4 Pole, 415 volts, 350 Amps 36 KA, adjustable type- 01 No OUT GOINGS (a) MCCB 4 Pole, 415 volts, 160 Amps 36 KA- 05 Nos(b) MCCB 4 Pole, 415 volts, 125 Amps 16 KA- 02 Nos (c) MCCB, 4 pole, 415 Volts, 63 amps of 16 KA- 01 Nos (d) Ampere meter (digital type) 0-250 Amps with selectro switch- 01 No (e) Volt meter (digital type) 0-500 volts with selector switch- 01 No (f) Indicator lamp (set of 3)- 01 set (g) Danger notice plate vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour (h) Provison of 02 Nos earthing terminals etc complete |
| 66 | Supply, install, testing and commissioning(In repair) of factory made LT panel outdoor type of size not less than 270 cm x 65 cm x 220 cm for 3 phase 415 Volts outdoor type cubical compartmentalised vermin and water proof fabricated out of 3.15mm thick CRCA sheet powder coated front and back door openable with locking arrangement, necessary ventilation,suitable for including 200 Amps rated aluminium bus bar for 3 phase system insulated with PVC sleaves and coloured with (Red, Yellow, Blue and Black) CTR and internal wiring with suitable size of PVC insulated copper wire, use with angle iron 60cmx60cmx6mm frame bottom of the panel board, 0.6 mtrs length legs(04Nos) grouted by using PCC foundation 1:3:6 type C1 using with 20mm graded stone aggregate, aluminium thimbling and cable entry boxes with cable glands including painting with two coat of powder coated painting over a coat of red oxide primer after dismanteling the existing unsv LT panel complete with following incoming/out going accessories:-IN COMING(a) MCCB 4 Pole, 415 volts, 250 Amps 36 KA, adjustable type- 01 Nos, OUT GOINGS (a) MCCB 4 Pole, 415 volts, 160 Amps 36 KA- 02 Nos(b) MCCB 4 Pole, 415 volts, 125 Amps, 16 KA- 02 Nos (c) Ampere meter (digital type) 0-250 Amps with selectro switch- 01 No (d) Volt meter (digital type) 0-500 volts with selector switch- 01 No (e) Indicator lamp (set of 3)- 01 set (f) Danger notice plate vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour (g) Provison of 02 Nos earthing terminals etc complete. |
| 67 | Supply, install, testing and commissioning(In repair) of factory made LT panel outdoor type of size not less than 270 cm x 65 cm x 220 cm for 3 phase 415 Volts outdoor type cubical compartmentalised vermin and water proof fabricated out of 3.15mm thick CRCA sheet powder coated front and back door openable with locking arrangement, necessary ventilation,suitable for including 200 Amps rated aluminium bus bar for 3 phase system insulated with PVC sleaves and coloured with (Red, Yellow, Blue and Black) CTR and internal wiring with suitable size of PVC insulated copper wire, use with angle iron 60cmx60cmx6mm frame bottom of the panel board, 0.6 mtrs length legs(04Nos) grouted by using PCC foundation 1:3:6 type C1 using with 20mm graded stone aggregate, aluminium thimbling and cable entry boxes with cable glands including painting with two coat of powder coated painting over a coat of red oxide primer after dismanteling the existing unsv LT panel complete with following incoming/out going accessories:-IN COMING(a) MCCB 4 Pole, 415 volts, 400 Amps 36 KA, adjustable type- 01 Nos, OUT GOINGS (a) MCCB 4 Pole, 415 volts, 160 Amps 36 KA- 01 Nos(b) MCCB 4 Pole, 415 volts, 125 Amps 16 KA- 02 (c) MCCB 4 Pole, 415 volts, 100 Amps 16 KA- 01 Nos (d) Ampere meter (digital type) 0-250 Amps with selectro switch- 01 No (e) Volt meter (digital type) 0-500 volts with selector switch- 01 No (f) Indicator lamp (set of 3)- 01 set (g) Danger notice plate vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour (h) Provison of 02 Nos earthing terminals etc complete. |
| 68 | Supply, install, testing and commissioning (In repair) of factory made Street light time switch outdoor type for 3 phase 415 Volts outdoor type cubical compartmentalised vermin and water proof fabricated out of 2mm thick CRCA sheet powder coated front door openable with locking arrangement, necessary ventilation, provision for cables side entry suitable for insulated with PVC sleaves and internal wiring with suitable size of PVC insulated copper wire, use with angle iron frame bottom of the panel board, legs(04Nos) grouted by using PCC foundation 1:3:6 type C1 using with 20mm graded stone aggregate, thimbling and cable entry boxes with cable gland including painting with two coat of powder coated painting over a coat of red oxide primer after dismanteling the existing LT panelcomplete with following incoming/out going accessories:-IN COMING (a) MCB63A 10KA 4 Pole, 415 volts, C curve - 01 No OUT GOINGS (a) Power contactor 40 A 3 pole - 01 Nos(b) Analog timer 16A 240 V AC QT Type- 01 Nos (c) Auto manual selector switch 6A- 01 Nos (d) Indicator lamp RYB(set of 3)- 01 set (e) Protection MCB 6 Amps- 01 No (f) Indicator lamp (set of 3)- 01 set (g) Danger notice plate vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour (h) Outgoing terminals 4 Way- 01 Nos (e) Enclosure of suitable size complete |
| 69 | Demolition of brick/stone masonry built in CM. all as specified. |
| 70 | M&L brick work with sub class B bricks straight or curved on plan to any radiusbuilt in CM 1:6 all as specified. |
| 71 | M&L for cement concrete 1:2:4 type B-0, using 12.5mm graded stone aggregate as in coping and bending rounded or chamfered on edgesincl necessary form work to obtain a smooth finishes complete all as specifiedand as directed. |
| 72 | M&L for 15 mm thick ready mix cement plastering over brick wall in cement mortar on external surface finished even and smooth and including raking out joints, hacking for key, scrubbing down with water etc.completeall as specified |
| 73 | M&L for preparation of newly plastered surfaces of any description and applying two coats of cement base paint over a coat of primer all as specified and directed. |
| 74 | Demolition of cement concrete in ground floor (unreinforced) and pavingsincluding tiles etc ,n exc 15cm thickness (below or above ground level) complet all as specified. |
| 75 | PCC 1:4:8 type D-2 as in sub base of flooring 75 mm thick all as specified and directed by Engr-In-Charge. |
| 76 | M&L for sand filling 75mm thick under floors or in foundations including watering as requiredall as specified and directed by Engr-In-Charge. |
| 77 | M&L for machine pressed precast concrete interlocking payer block any shape and size confirming to IS -15658-2006 of 60 mm thickness (M-35 Grade) with grey cement and no pigment all as specified and directed by Engr-In-Charge. |
| 78 | Dismantling fencing wire mesh, any type as per site all as directed. |
| 79 | Supply only chain link MS galavnised any size and type complete all as specified and directed |
| 80 | Fixing only chain link fencing incl line wires any mesh size & type to any type of standards rails straining bolts etc. incl provision of bindig wire. |
| 81 | S&Fscrew bolts (machine made) with hexagonal or squre heads at one end and screwed the other each screw to be fitted with one washers and one hexagonal or square nut length of bolts not exc 5cm and dia of shank 10 mm. |
| 82 | Dismantling posts or struts (wood, steel or R.C.C) any section, including taking out embedded portion in natural ground and making good disturbed ground all as specified and directed. |
| 83 | M&L PCC 1:3:6 type C2 (40mm graded aggregate) in foundations, filling and mass concrete all as specified and directed by engineer-in-charge. |
| 84 | S&F Hand rails, half round or other stock section or core for wooden hand-rail straight portion, drilled & countersunk for balusters running bars, for doors,balusters,nosing to steps including embeding in concrete & screwing etc. wind ties for roof including securing bolts; posts & struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., & similar work conforming to Fe 290-0 Gde E-165 |
| 85 | M&L for preparation of new steel surfaces of any description over 10cm width or girth and apply two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. |