| 1 | Note :(i) Please refer Sch A/ BOQ Notes before quoting the tender for all phases/ items mentioned below.(ii) Amount of Schedule of credit shall be deducted offline |
| 2 | Excavation in trenches not exc 1.5 mtr wide & not exc 1.5 mtr in depth for foundation etc or for manholes, laying of pipe lines, cables, pipes etc in soft /loose soil and getting out complete all as specified and directed. Note:-(i) If excavation is carried with mechanically or by JCB etc then damaged to the existing assets i.e. Sewage Lines/Electrical cables/Drains etc shall be repaired by contratcor on his own cost. (ii)The quoted rate deemed to be include for any type of dewatering whereverrequired. |
| 3 | Returning filling in, including spreading, leveling watering & well ramming in layers not exc 25 CM thick complete all as specified and directed. |
| 4 | Removing excavated material to a distance not exc 50 mtr & depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and diected. |
| 5 | Taking out existing CI/DI pipe line, of any class including CI fitting with spigot and socket ends/ flanged end and lead joint including burning out lead joints and recovering lead for reuse in new CI pipes/fittings of any class/type complete all as specified and directed of following sizes:- |
| 6 | (a) 80mm bore |
| 7 | (b) 100 mmbore |
| 8 | (c )150 mm bore |
| 9 | (d) 200 mm bore |
| 10 | (d) 250 mm bore |
| 11 | Relaying CI pipe including fittings with spigot and socketed end/ flanged end,centrifugally cast laid in trenches after cleaning internally and externally, drawing out foreign material/ rust complete and jointing with and including new titon joints for fixing of pipe complete all as specified and directed for the following sizes:-Note :- (i)Earth work, joints and CI specials/fittings of the pipes shall be measured and paid separately under appropriate item. |
| 12 | (a) 80mm bore |
| 13 | (b) 100 mmbore |
| 14 | (c )150 mm bore |
| 15 | (d) 200 mm bore |
| 16 | (d) 250 mm bore |
| 17 | Supply, laying and jointing of DI iron pipes SS class K-9 of standard length with internal cement mortar coating and external surface with bituminious paint, ISI marked including nuts, bolts, packing material etc; and making the joint leak proof complete all as specified and directed for the following sizes:-Note : - Earth work, joint and CI/DI specials/fittings of the pipes shall be measured and paid separately under appropriate items of schedule. |
| 18 | (a) 100 mmbore |
| 19 | (b )150 mm bore |
| 20 | (c) 200 mm bore |
| 21 | (d) 250mm bore |
| 22 | Supply, laying, jointing and testing of DI pipes with flanged end, SS class, K-9 of standard length with internal cement mortar coating and external surface with bituminious paint, IS: 8329 including rubber gaskit/fiber gaskit, nuts, bolts, packing material etc; and making the joint leak proof complete all as specified and directed for the following sizes:-Note : - Earth work, joint and CI/DI specials/fittings of the pipes shall be measured and paid separately under appropriate items of schedule. |
| 23 | (a) 100 mmbore |
| 24 | (b )150 mm bore |
| 25 | (c) 200 mm bore |
| 26 | (d) 250mm bore |
| 27 | S&F of push on flexible rubber gasket (Tyton) joint ISI Marked suitable complete all as specified and directed for following sizes :- |
| 28 | (a)80mm bore |
| 29 | (b)100mm bore |
| 30 | (c)150mm bore |
| 31 | (d) 200 mm bore to 250mm bore |
| 32 | Cutting of cast iron pipes in position for insertion of new tees, branches, etc comprising of two cuts complete all as specified and directed for the following sizes:- |
| 33 | (a) 80mm bore |
| 34 | (b)100 mmbore |
| 35 | (c )150 mm bore |
| 36 | (d) 200 mm bore |
| 37 | S&F of CI/DI bend (any type, radius and angle), tapers any type, flanges, straight bend including decreasing or double socket etc; tee pieces, tail peiecessingle branch, flanged adapter, \"Y\" junction, all sockets or socket and spigot or flanged, collars, caps and plugsfor spigot socketed pipes of upto 150mmsize complete all as specified and directed. |
| 38 | S&F of CI/DI bend (any type, radius and angle), tapers any type, flanges, straight bend including decreasing or double socket etc; tee pieces, tail peiecessingle branch, flanged adapter, \"Y\" junction, all sockets or socket and spigot or flanged, collars, caps and plugsfor spigot socketed pipes of 200mm to 300mmsize complete all as specified and directed. |
| 39 | M&L for cutting floor/ PCC/ footpath of 20 cm width and 90 cm depth as required for re-laying/ laying of cable/pipe etc. and making good by filling earth and 150 mm thick PCC 1:2:4, type B-1 (using 20 mm graded stone aggregate) at the top to match the level as per site requirement complete all as specified and directed. |
| 40 | M&L for run lead joint for spigot and socketed end CI pipe & fittings including excavation, returning and refilling complete all as specified and directed for following:- |
| 41 | (a)80 mm bore |
| 42 | (b) 100 mm bore |
| 43 | (c )150mm bore |
| 44 | (d) 200mm bore |
| 45 | M&L for mild steel framed work for made of angle iron with and including mild steel sheet as required including necessary welding, cutting, hinges, locking arrangments, flanges for connection of GI Pipes with CI pipes and its nut bolts etc including painting with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. |
| 46 | Taking down existing GI steel tubing and connections complete all as specified and directed of following sizes:- |
| 47 | (a) 80 mm bore |
| 48 | (b) 50 mm bore |
| 49 | (c) 40 mm bore |
| 50 | (d )25 mm bore |
| 51 | (e)20 mm bore |
| 52 | (f) 15 mm bore |
| 53 | Refixing retrived old steel tubing and connections in new or old position including cleaning internally and externally any grade/make, laid in trenches/ floor or fixed to walls with and including new fittings such as sockets, tee, union elbow etc complete allas specified and directed of follwing sizes:- |
| 54 | (a) 80 mm bore |
| 55 | (b)50 mm bore |
| 56 | (c) 40 mm bore |
| 57 | (d) 25 mm bore |
| 58 | (e)20 mm bore |
| 59 | (f) 15 mm bore |
| 60 | Supply & laying GI tubing, medium grade, ISI marked 1239 in any length including cutting, threading and making connection in new or old position with and including all type of GI new fittings for laid in trenches/wall/ceiling/floor complete all as specified and directed of following sizes:- |
| 61 | (b) 80 mm bore |
| 62 | (c) 50 mm bore |
| 63 | (d) 40 mm bore |
| 64 | (e )25 mm bore |
| 65 | (f)20 mm bore |
| 66 | (g) 15 mm bore |
| 67 | Cutting cast iron/Ductile iron pipes and reducing to required length before laying complete all as specified and directed of following sizes:- |
| 68 | (a) 80 mm |
| 69 | (b) 100 mm |
| 70 | (c) 150mm |
| 71 | (d) 200mm |
| 72 | (e) 250mm |
| 73 | Drilling and taping cast iron water mains (in position) for making branch connections complete all as specified and directed of following sizes:- |
| 74 | (a) 15mm |
| 75 | (b) 20 mm |
| 76 | S&F in replacement new mechnical joints of DI pipe, K9 including nuts, bolts and all connecting accessories complete all specified and directed of following sizes:- |
| 77 | (a) 80 mm |
| 78 | (b) 100 mm |
| 79 | (c) 150mm |
| 80 | (d) 200mm |
| 81 | (e) 250mm |
| 82 | S&F in replacement cast iron flanged sluice valve of class PN 1.6, long body, ISI marked, confirming to IS-14846 with stainless steel spindle and hand wheel including nuts, bolts, rubber gasket for installation of valve complete including taking down existing one all as specified and directed of following sizes:- |
| 83 | (a) 80mm dia |
| 84 | (b)100 mmbore |
| 85 | (c) 150 mm bore |
| 86 | (d) 200mm bore |
| 87 | (e) 250mm bore |
| 88 | M&L for brick work with sub class B brick straight or curved on plain exc 6 m mean radius built in cement mortar 1:4 complete all as specified and directed. |
| 89 | M&L for PCC 1:2:4 type B1 using 20 mm graded stone aggregate as in copping/supports and similar work including necessary form work etc complete all as specified and directed. |
| 90 | M&L for rendering 15mm thick on any face of brick work in cement mortar 1:4, finished an even and smooth without using extra cement complete all as specified and directed. |
| 91 | S&F in replacement gun metal globe or gate valves, confirming to IS 778 with iron wheel head, screwed both ends for iron pipe and fixed in existing or new position complete all as specified and directed for following size:- |
| 92 | (a)50 mm bore |
| 93 | (b)40 mm bore |
| 94 | (c)25 mm bore |
| 95 | S&F of air release valve as per IS-14845 double chamber including nuts, bolts, rubber sheets complete all as specified and directed of following sizes:- |
| 96 | (a) 80 mm |
| 97 | (b) 100 mm |
| 98 | S&F in repairs CI new flange type, non return valves of size 100 mm, ISI marked conforming to IS 5312 including nuts, bolts and all connecting accessories complete all as specified and directed. |
| 99 | S&F in repairs CI new flange type, non return valves of size 150 mm, ISI marked conforming to IS 5312 including nuts, bolts and all connecting accessories complete all as specified and directed. |
| 100 | S&F in repairs CI new flange type, non return valves of size 200 mm, ISI marked conforming to IS 5312 including nuts, bolts and all connecting accessories complete all as specified and directed. |
| 101 | M&L for valve chamber 600x600x900 mm for 80/50mm sluice valve, including brick massonary 230 mm thick with cement mortar 1:6, on PCC 1:4:8, D-2 using 40 mm gradded stone aggregate of 100mm thick foundation, 10mm thick plaster internally in CM 1:6, Flooring 40mm thick in PCC 1:2:4 type B1, using 20 mm gradded stone aggregate over 75 mm PCC base, 3mm thick for cover plate with locking arrangement, handle, etc duly painted complete all as per specifications. |
| 102 | M & L for MS Clamp 50mm width 4mm thick and not less than 30cm in length 02 Nos for connection of 50mm dia GI pipe with Socket for fixing 50mm dia pipe with 80mm/100mm/150mm/200mm dia CI/DI pipe complete all as specified and directed. |
| 103 | M & L for MS Clamp 50mm width 4mm thick and not less than 30cm in length 02 Nos for connection of 40mm dia GI pipe with Socket for fixing 40mm dia pipe with 80mm/100mm/150mm/200mm dia CI/DI pipe complete all as specified and directed. |
| 104 | M & L for MS Clamp 50mm width 4mm thick and not less than 30cm in length 02 Nos for connection of 25/20mm dia GI pipe with Socket for fixing 25/20mm dia pipe with 80mm/100mm/150mm/200mm dia CI/DI pipe complete all as specified and directed. |
| 105 | S&F in replacement new dismantling Joint PN 16 double flanged typefor DI pipe, K9 including nuts, bolts and all connecting accessories complete all specified and directed of following sizes:- |
| 106 | (a) 80 mm |
| 107 | (b) 100 mm |
| 108 | (c) 150mm |
| 109 | (d) 200mm |
| 110 | (e) 250mm |
| 111 | Deduct Schedule of credit (calculation will be done off line) Rs. 1333923.64 |