| 1 | Cleaning of the chocked/blocked sewage lines of any bore through mechanically by Jet Machine or any mechanical means between manholes and removing muck sludge/silt/liquid mud etc (incl foul position) from pipes including taking down cover slab of any type, thickness and size carefully and refixing in same position after necessary cleaning and removing the cleaned sludge out side of MD land in sealed containers on same day, all as specified and directed not exceeding1.50 m depth. |
| 2 | Cleaning of the chocked/blocked manholes/septik tanks/Gully trap/Nahani Trap/Floor trap, not exceeding 1.5 m depth, mechanically by Jet Machine or any mechanical means opening the covers, removing liquid/sludge mixed liquid under any position including foul condition and cleaning the inlets and outlets etc with water, placing the cover back in position and dispoing off the same in sealed container on same day,out side of MD land complete all as specified and directed. |
| 3 | Dewatering & Cleaning of septic tank/ soakage well at diffrent locations of any description up to any users capacity by mechanically only with using sewage tankers/truck capacity of 5000 ltr or above mounted hydraulic jet pressure mechane with heavy duty flushing the sewage line and with heavy duty sewage suction pump including necessary arrangements such as sweepers to cleanup the site after work in the following steps :(i) Bailing out /dewatering of septic tank ,soakagewell (ii) Removing of all sludge/waste material (liquid/semi liquid /solid/semi/solid) silt, bricks bats debris mud soil , polythene etc any kind of materials from all chambers of the septic tank,soakage well, clean the floor and walls of the tank after removing the same complete(iii) Removing the blockage of inlet/outlet pipe in any depth , in any situation (iv) Finally flushing septic tank /soakage well includinginlet/outlet with adequate water and making fully functional the septic tanks/soakage well with entire satisfaction of Engineer-in- charge and removing retrieved/takingout all type materials , sludge/soil waste liquid/semi liquid /solid/ semi solid/ or any unwanted materials of any kind etc outsidethe periphery of defence land at his own arrangementin packed container where sanitary hazards do not take place as per directions/instructions of civil authority and buried in excavated pits in suitable size and depth and covering the same with the soli obtained from excavation of pit includingall excavations and earth work including applying bleaching powder to mainthygiene. Adequatewater for flush out sludge to be arranged by the contractor without any extra cost and including taking out manholes cover and re-fixing the same after cleaning/removing blockage, fully functional complete all as specified and directed. Note :- A particularr septic tank/soakge well which is undertaken once for cleaning and paidfor shall be kept function or entire contract period and no extra payment shall be made for repetitive cleaning if required. |
| 4 | Demolition of brick work of any descriptionand in any positionnot otherwise specifically provided complete all as specified and directed. |
| 5 | M & L forbrick workold size withsub class `B` bricks in cement mortar straight or curved on plan exceeding 6 m mean radius built in CM (1:4) provided complete all as specified and directed |
| 6 | Ditto all as per item No. 5.00 above but exceptbricks. |
| 7 | M & L forrendering 15 mm thick in CM (1:4) on brick work or concrete surfaces, finished even & smooth without using extra cement incl mixed with WPC as per manufacturer instruction complete all as specified & directed. (Note ; WPC shall be measured seperatly |
| 8 | M & L for rendering 15 mm thick cement plaster in CM (1:6) on other thanfair faces brick work finished even and smooth without using extra cement . |
| 9 | Taking down cement plaster on bricks or stone walls etc., including raking out joints, hacking for key scrubing down with water etc., all as directed. |
| 10 | M & L for preparation of new undecorated surfaces of walls and applying two coat of oil bound distemper over a coat of primer over and including 1 mm thick (average)wall care putty complete all as specified and directed. |
| 11 | M & L for preparation of new undecorated surfaces of walls and applying two coat of cement based paint over a coat of primer complete all as specified and directed. |
| 12 | Demolition of reinforced cement concreteof any descriptioncomplete all as specified and directed. |
| 13 | Demolition of cement concrete (Unreinforced ) of any descriptionand in any position not otherwise specifically described for complete all as specified and directed. |
| 14 | M&L for formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) fair finishedflat surfaces complete all as specified. |
| 15 | M&L for formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide , horizontal or sloping and similar work exc 10cm but n exc 20cm wide for fair finished surfaces of concrete. |
| 16 | M & L forpre - cast RCC (1:2:4) type B-1 using 20 mm graded stone aggregate as in manhole cover / drain covers set in CM (1:4) etccomplete all asspecified |
| 17 | M & L for PCC (1:4:8) type D-2 using 40 mm graded stone aggregate as in foundations, filling and mass concrete etc complete all as specified and directed. |
| 18 | M & L for PCC (1;3:6) type C-2 using 40 mm graded stone aggregateas in surface channel and drain, complete all as specified and directed. |
| 19 | M & Lfor PCC (1;3:6) type C-2 using 75 mm thick as in flooring /paving/plinth protection including finishing even & smooth without using extra cement complete all as specified and directed. |
| 20 | Demolition or breaking up drain pipesof150 mm dia (SGSW/AC or reinforced concrete) set in cement mortar including breaking and removal of bedding and hunching complete all as specified and directed. |
| 21 | Ditto all as per Item No 20.00 above but for 200 mm dia |
| 22 | M & L for150 mmboreRCCPipe class NP-2 lwith collars laid and jointed in CM (1:3) complete all as specified and directed. |
| 23 | Ditto all as per Item No 22.00 above but for 200 mm dia pipe |
| 24 | Excavationin trenches not exceeding 1.50 m wide and not exceeding 1.50 m depth & getting out in soft/loose soil complete all as specified and directed. |
| 25 | Returning , filling in including spreading and levellingwatering and well and ramming in layers not exc 25 cm complete all as specified and directed. |
| 26 | Removing excavated soil not exc 50 mtr and depositing where directed at a level not exc 1.5 mtr from the starting point complete all as specified and directed. |
| 27 | Supply only integral water proof compound complete all as specified and directed. |
| 28 | M & L for RCC(1:2:4) Type B-1 using (20 mm graded aggregate)for slabs supported on walls, beams and columns, in floors, roofs, landings and in shelves and the like including necessary form work complete all as specified and directed. |
| 29 | Cutting into existingmanholes for connectingnew drainsmaking good to pipeof 150mm dia and rendering cutting outexisting benching forand forming branch channel( ½round or ¾section )in cementconcrete(1:2:4) type B-1 smooth finishedand reformingbenchingas requiredcomplete all as specified and directed. |
| 30 | Cleaning of COVERED drain of width not exc 1.50 mand depth upto 1.50 m including cleaning the grass, bushes mules, silts etcby manuallyfrom the bottomand both sides (up to1.00 mtr) both sides of drainat the top leof the drain including removal of the grass, bushes mules, silts etc up distance of 250 m including taking out carefully RCC drain cover/ MS gratingand refixing same in cm 1:4 after cleaning the drain complete all as specified and as directed. |
| 31 | M & L for mild steelTMTbars 10 mm dia., and over cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia., or securing with clips qual complete all as specified and directed. |
| 32 | Dimentaling of stone slabs and tiles of any description or thickness in floors, aprons etc complete all as specified and directed. |
| 33 | M & L for 75 mm thick PCC (1:4:8) Type D-2 using 40 mm graded stone aggregate as in sub base and mass concrete complete all as specified and directed. |
| 34 | M & L for providing and laying 60 mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footpath, parks, lawn, drive ways or light traffic parking etc, of required strenth, thickness & size shape mady by table vibratory method using PU mould, laid in required colour & pattern over and including 50 mm thick compacted bed of fine sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand complete all as specified and directed. |
| 35 | Relaying of 60-90mm thick factory made chamfered edge cement concrete paver block of any grade/colour/design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand complete all as specified and directed by Engr-in-charge. |
| 36 | M & Lfor chequered cement concrete tiles 20cm x 20cm x 25mm thick set jointed and pointedin neat cement sluury in floors complete all as specified and directed. |
| 37 | M & Lfor PCC (1:2:4) type B-1 using 20 mm graded stone aggregate as in copings and the like including weathering, slightly rounded or chamfered angles and throating complete all as specified and directed. |
| 38 | M & L for providing two coat of master seal 550 (Two component acrylic modified cementious coating coverage 1.80 Kg/Sqm for 1mm thick layer) of BASF or equvalient make in Fosroc /Sika to preventleakage /seepagethrough sunken floor over prepared surfaces complete all as specified and directed. |
| 39 | M & L forPCC (1:5:10) type E2 using 40 mm graded stone aggregate as in foundation, filling and mass concrete complete all as specified anddirected. |
| 40 | S & F in repair 40 mm dia GI tubing medium grade galvanised with all fittings under floor as spout pipe complete all as specified and directed. |
| 41 | S & F in repair Vitreous china squatting pan \"orrisa\" pattern size 580mm x 440 mm white integral floor rests ( excluding flushing cistern ) including connection to trap and to flushing pipe anti syphonage pipe etc complete including making good to floor, complete all as specified and directed. |
| 42 | Taking down easing and adjusting/repairing CHINA Urinal/WHB/ wash down water closet including complete accessories of any description of any size each repairingby bolts/screws/white cement(including) and then refixing in same opening/position, all as specified and as directed. Note :- Replacement of waste pipe, PVC Connection, taps etc shall be measured and paid separately. |
| 43 | S & F in repair Vitreous china urinals, Half stall type, white with grating union for discharge pipe of wall type complete including providing and fixing plugs, bedding urinal against wall in CM(1:2), securing urinal to plug with and including 60 mm long brass screw pointing around urinal back in cement, fixing automatic flushing cistern with brackets flush pipe grating and union for discharge pipe, complete all as specified and directed. |
| 44 | Rectify sewage system complaint in daily routine basis as per complaint lodged by user at complaint cell of AGE B/R-II sub division by deploying manpower by cleaning/clearing/removal blockage such as blockage /chocked in any type size/height/depth/location of WCs/urinal/bathroom /kitchen/WHB along with any type/size/height/depth bore of outlet SGSW/PVC/CI/UPVC/RCC etc pipe and including all kind of traps such as inspection chamber/floor/nahani/gully/intercepting/bottle trap/P,S/multi floor traps of any SGSW/PVC/CI/UPVC etc description and in any position below or above ground level,in any floor,located in different situations,including opening the clearing eyes of sewage waste pipes/vent pipe etc,opening the access cover/granting and taking out/removing all material such as sludge/soil waste/sludge water/polythene/mud/slit/ liquid/ semi liquid/semi solid/ solid/ bricks bats/ debris/ soil etc any unwanted materials of any kind etc and also cleaning/ removal blokage up to Ist man hole sewage line etc in any type/size/height/depth/location/pattern including flushing with adequate water after cleaning make the all system fully functional to the entire satisfaction of Engr-in-Charge, re-fixing the existing opened access cover and removing all retrieved material/ unwanted/ foreign material in any liquid/ solid state etc outside the periphery of defence land at his own arrangement where sanitary hazards do not take place as per directions/instructions of civil authority and buried in excavated pits in suitable size and depth and covering the same minimum 25cm thick compacted layer of soil with the soil obtained from excavation of pit including all excavations and earth work including applying bleaching powder to maintain hygiene. adequate water for flush out to be arranged by the contractor without any extra cost complete all as specified and directed. |
| 45 | S & F in repair PVC connection of 15 mm dia with PTMT nuts of length 450mm, complete all as specified and directed. |
| 46 | S & F in repair PVC waste pipe 32 mm bore for WHB/Urinal complete all as specified and directed. |
| 47 | S & F in repair 10 ltrs capacity PVC valveless, symphonic action type, flushing cistern, low level, with inlet ,ball valve, float and handle includingflush pipe (long bend) for low level cistern complete all as specified and directed. |
| 48 | Removal of air lock / blockage of water in GI, tubing 15 mm / 32mm/50mm bore cleaning the pipe or fittings etc and re-fixing the same in position complete all as specified and directed. |
| 49 | S&F in repairs internal flushing kit of PVC low level flushing cistern and making in functional complete all as specifiedand dircted . |
| 50 | S&F in repairs 15mmstop valves (concealed type) cast copper alloy,chromimum plated with long shank cup screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and as directed. |
| 51 | S&F in repair vitreous china wash down water closet one piece with integrated cistern, seat cover and twin flush fitting complete all as specified and as directed . |
| 52 | S & F in repairs vitreous china wash down water closet pan (pedestal pattern), including necessary fittings complete all as specified and directed. |
| 53 | S & F in repairs vitreous china WHB ,white or coloured, size 550 mm x 400 mm with 32 mm dia CP waste coupling and all fittings and fixtures complete all as specified and directed. |
| 54 | S & F in repair 15 mm bore small GI fitting/articles like socket, elbow, reducer, unions, nipple(not more than 150mm long), long screw and other articles complete all specified & directed. |
| 55 | S & F in repairs 15mm dia Ball valves high pressurewithpolythene floatand fly nutcomplete, screwed forfor iron pipeor brass ferrulecomplete all as specified and directed. |
| 56 | S & F in repairs 20 mm dia Ball valves high pressurewithpolythene floatand fly nutcomplete, screwed for iron pipeor brass ferrule complete all as specified and directed. |
| 57 | S & F in repair 15 mm bore Bib taps standard of PTMT any colour high pressure screwed for iron pipes and fixed(minimum weight 15 mm- 90 gmscomplete all as specified & directed. |
| 58 | S & F as in repair 15 mm dia bibcock ,chromium plated, cast copper alloy ,fancy type with capstan head screwed down, screwed for iron pipe or for brass ferrule complete all as specified & directed. |
| 59 | S & F in repairs 15 mm bore pillar taps fancy type chromium plated screw down high pressure with long screwed shanks and fly-nuts, screwed for iron pipe all as specified and directed. |
| 60 | S & F in repair 15 mm bore Pillartaps of PTMT any colour high pressure screwed for iron pipes and fixed(minimum weight 15 mm- 110 gms)complete all specified & directed. |
| 61 | S & F in repair 15 mm bore Stop Valve of PTMT any colour high pressure screwed for iron pipes and fixed(minimum weight 15 mm- 90 gmscomplete all as specified & directed. |
| 62 | S & F in repair 15 mm bore Angle Valve of PTMT any colour high pressure screwed for iron pipes and fixed(minimum weight 15 mm-110 gms complete all as specified & directed. |
| 63 | S&F in repairs health faucet cock brass chromium plated including 1.5 M long flexible pipe of chromium platedcomplete all as specified and directed |
| 64 | S & F as in repair 15 mm dia angle cock/stop cock, chromium plated, cast copper alloy, screwed down high pressure, screwed both ends for iron pipe or for union complete all as specified & directed. |
| 65 | M & L for glazed ceramic colourtiles in vertical surface of size 350 mm x 250 mm x 7mm/ 450X 350X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match over and including 10 mm thickrendering in CM (1:4) complete all as specified and directed. |
| 66 | M & L for 7 to 8 mm thick Non - skid Ceramic colourtiles (square/ rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm as in floors etc. set and jointed in neat cement slurry over andincluding 15 mm thick screed bed in CM (1:6) complete all as specified and directed. |
| 67 | Dismantling floor, hearth or wall tilling including cement mortar beading (but not backing), removing serviceable tiles to store and rubbish off the premises. |
| 68 | Taking down 15 mm dia GI steel tubing and connection including cleaning for re-fixing or removal ,complete all as specified and directed |
| 69 | Re-fixing of 15 mm bore old steel tubing and connection in new or old position fixed I wall or floor, ceiling etc complete all as specified and directed. |
| 70 | M & Lfor GI Tubing15 mm dia ,medium grade galvanised ,with all fittings and fixed complete to wall and ceilings or laid in floors complete all as specified and directed. |
| 71 | Taking down 20 mm dia GI steel tubing and connection including cleaning for re-fixing or removal ,complete all as specified and directed |
| 72 | Re-fixing of 20 mm bore old steel tubing and connection in new or old position fixed I wall or floor, ceiling etc complete all as specified and directed. |
| 73 | M & Lfor GI Tubing20 mm dia ,medium grade galvanised ,with all fittings and fixed complete to wall and ceilings or laid in floors complete all as specified and directed. |
| 74 | S&F Low in repairs density polyethylene pipes (LDPE)40mm bore of pressure rating 6 kgf/cm2 fixed complete to walls, ceilings or in floors etc complete all as specified and directed. |
| 75 | S&F in repairs Grating doom 100mm dia of PTMT (Minimum weight 25gms) complete all as specified and directed. |
| 76 | Cleaning of PVC tank of capacity exc 500 lt and not exceeding 1000ltr of any colour/shapeatanyheight including marking of date of cleaning with the help of paint is neccesarycomplete all as specified and directed. |
| 77 | Cleaning of PVC tank of capacity n exc 500 lt of any colour/shapeatanyheight including marking of date of cleaning with the help of paint is neccesarycomplete all as specified and directed. |
| 78 | S & f in reapir SFRC manholes / drain cover of size 900x450x90mm of grey colour complete all as specified and directed by eng-in-chg. |
| 79 | S & F FRP manhole cover for 750mm clear opening of manhole including frame of 5 ton loading capacity using specially formulated and tested loading as per IS 1726 polyster resin, high abrasion resistense (grinding resistence ) with key holes and keys as lifting mechnism to faciliate the lifting and replacementcomplete all as specified and directed. (Note-Lifting arrangement of cover shall deemed to be included in the quoted rate) |
| 80 | S & F in repair of Double wall corrugated pipe(HDPE) classSN-8 , laid and jointed complete with collars for 150mm dia pipe complete all as specified and directed |
| 81 | S& Fin repair of Double wall corrugated pipe(HDPE) classSN-8 , laid and jointed complete with collars for 200mm dia pipe complete all as specified and directed |
| 82 | S&F in repair PVC (SWR) pipes single socketed150 mm borein any length with rubber ring joints fixed to walls |
| 83 | S&F in repair PVC (SWR) pipes single socketed110 mm borein any length with rubber ring joints fixed to walls |
| 84 | S&F in repairs PVC (SWR) pipes single socketed75 mm borein any length with rubber ring joints fixed to walls |
| 85 | S&F in repairs PVC (SWR) bends any radius 75mm bore complete all as specified and directed |
| 86 | S&F in repairsPVC (SWR) bends any radius 110mm bore complete all as specified and directed |
| 87 | S & F in repairs PVC (SWR) branch piece, single (single Y) equal or unequal 110mm borecomplete all as specified and directed |
| 88 | S&F in repair PVC (SWR) floor trap, plain with grating including jointing with solvent cement 75mm dia of out let complete all as specified and directed |