| 1 | Dismantling of ACSRconductors, line seperator, service feeder or distribution span from the existing LT&HT over head lines etc., complete all as specified and directed. |
| 2 | Dismantling & taking down insulators any type and size from the existing LT & HT line, complete all as specified and directed. |
| 3 | Dismantling & taking down cross arms or MS channel or angle section etc from the existing LT ,HT Line & Transformer etc and setting aside for reuse or remove, complete all as specified and directed. |
| 4 | Dismantling LT stay assembly of any size, complete all as specified and directed. |
| 5 | Dismantling of steel tubular pole of any size from bottom by demolition of concrete, complete all as specified and directed. |
| 6 | S&F LT steel tubular swaged poles complete with cast iron base plate,finial taper plug, bolts,nuts & screws as specified type 410 SP-31 (9 mtr long) complete all as specified as directed.Note Excavation & PCC work shall be measured and paid seperately, complete all as specified and directed. |
| 7 | Excavating in Trenches not exc. 1.50 mtr wide and not exc. 1.50 mtr in depth, Taking Out and Laying of Cables, etc. and getting out in Soft/ Loose Soil, complete all as specified and as directed. |
| 8 | All as per item No 7.00 here in before but Excavation in trenchesexc. 1.5m wide and n. exe 3 mtr depth |
| 9 | Returning, Filling in, including Spreading, Levelling, Watering and Well Ramming in Layers not exc. 250mm in Soft/Loose Soil, complete all as specified and as directed. |
| 10 | Removing excavated Materials (Soils) not exc. 50.00 mtr and depositing where directed at a level not exc. 1.50 mtr above the Starting Point in Soil, complete all as specified and as directed. |
| 11 | Horizontal Boring for passing GI protection pipe up to40 to 100 mm bore (dia), under road / foot path, not exc. 10.00 metre in a single length, complete all as specified and as directed. |
| 12 | M&L Sand Cushioning (dry) in Trenches for protection of UG Cables (below, above and around the UG Cable laid in Trenches) of 230mm Spread thick -ness and consolidated (punned) upto 180mm thickness, complete all as specified and as directed.(NOTE : For the purpose of Payment, Punned thick-ness of Sand Cushioning only shall be Measured and Paid for). |
| 13 | Horizontal Boring for passing GI protection pipe up to 100 mm bore (dia), under road / foot path, not exc. 10.00 metre in a single length, complete all as specified and as directed. |
| 14 | Taking down/out unserviceable or serviceable LT UG Cables of any sizeand Connections including Bricks, GI Pipes, etc. of any descriptions, laid in Trenches and/or fixing with Walls/Poles including Segregating of Serviceable Materials viz Bricks, Cables, GI Pipes, etc. and keep in Safe custody for re-use, complete all as specified and as directed. |
| 15 | Dismantling and shifting of indoor type LT Panel Board of any size with all accessories after disconection ofoutgoing & incomming cables, earth strips etc. and taking away from existing location andre-installation on the P.C.C./ brick platform duly grouted in the new platform constructed within 15 to 30 mtr from the existing location. incl reconnection of all outgoing and incomming cables, all as specified & as directed. ( NOTE : Foundation Work & earth work are included in quoted rate.) |
| 16 | Supply & Laying or Fixing or Passing through Pipe, XLPE insulated, Armoured, Electric Power UG Cable (Heavy Duty) with Aluminium Conductor, 1100 Volt Grade, Nominal Cross-Sectional Area 240 sqmm 3.5 core and Testing, including Brass Compression Cable Gland, Terminal Lug, etc. complete all as specified and as directed. |
| 17 | All as per Item No. 16 above, but Nominal Cross-Sectional Area 185Sqmm 3½ Core. |
| 18 | All as per Item No. 16 above, but Nominal Cross-Sectional Area 95Sqmm 3½ Core. |
| 19 | All as per Item No. 16 above, but Nominal Cross-Sectional Area 70Sqmm 3½ Core. |
| 20 | All as per Item No. 16 above, but Nominal Cross-Sectional Area 35Sqmm 4Core. |
| 21 | All as per Item No. 16 above, but Nominal Cross-Sectional Area 25Sqmm 4 Core. |
| 22 | All as per Item No. 16 above, but Nominal Cross-Sectional Area 16Sqmm 4 Core. |
| 23 | M&L for cable jointing kit for 1.1KV grade for outdoor straight through heat shrink type joint complete with jointing material and accessories suitable for 3.5 core PVC/ XLPE armoured aluminium conductor cable of size 50-120 sqmm complete all as specified and directed. Make-3M/ Raychem |
| 24 | M&L for cable jointing kit for 1.1KV grade for outdoor straight through heat shrink type joint complete with jointing material and accessories suitable for 4 core PVC/ XLPE armoured aluminium conductor cable of size 25 to 50 sqmm complete all as specified and directed. Make-3M/ Raychem |
| 25 | S&F Sub-Class B brick, well burnt, laid breadth-wise along the axis of Cable laid in Trenches over Sand Cushion laid for UG Cable Protection, complete all as specified and as directed. |
| 26 | M&L for cutting the road/hard standing and making good disturbed surface by using PCC type C2 (1:3:6) by using 20 graded stone aggregate for the fixing the pipe complete all as directed by the Engr-in-Charge at site. |
| 27 | S&F Galvanised Iron Pipe 80mm Bore (dia) ‘Light Grade’ for protection of UG Cable, laid in Floors/ Road Crossing, fixing to Pole with Mild Steel Clamps, Nuts, Bolts, etc., complete all as specified and as directed. |
| 28 | S&F Galvanised Iron Pipe 50mm Bore (dia) ‘Light Grade’ for protection of UG Cable, laid in Floors/ Road Crossing, fixing to Pole with Mild Steel Clamps, Nuts, Bolts, etc., complete all as specified and as directed. |
| 29 | S&F Galvanised Iron Pipe 40mm Bore (dia) ‘Light Grade’ for protection of UG Cable, laid in Floors/ Road Crossing, fixing to Pole with Mild Steel Clamps, Nuts, Bolts, etc., complete all as specified and as directed. |
| 30 | S&F Galvanised Iron Pipe 32mm Bore (dia) ‘Light Grade’ for protection of UG Cable, laid in Floors/ Road Crossing, fixing to Pole with Mild Steel Clamps, Nuts, Bolts, etc., complete all as specified and as directed. |
| 31 | M&L cement concrete PCC type C-2 (1 : 3 : 6) 40 mm graded stone aggregate for pole foundation including necessary form work and forming neat finish surfaces complete all as directed. |
| 32 | M&L cement concrete PCC type C-2 (1 : 2 : 4) 12.5mm graded stone aggregate for copping of pole for existing/new pole including necessary form work and forming neat finish surfaces complete all as directed. |
| 33 | S&F Cable Junction Box 155X210X92mm in size, made out of thermoplastic sheet having IP 66/69 protection for outdoor installation fixed with 4 way bakelite cable terminals including 03 Nos polymide gland with check nut (M-32 - 2 nos) fixed on poles with flat aluminium strip clamps of size 25x3mm, nuts, bolts, washers etc. including taking out of old unserviceable cable junction box complete all as specified and as directed.Make : Cat No. KF 1616 G of HENSEL or equivalent model in SPELSBERG/RITTAL/SINTEX. |
| 34 | Supplying and laying PVC insulated and FR PVC sheathed, Copper Conductor (flexible) industrial cable, 1100 Volt, conforming to IS 694 electric control cable with copper conductor, 1100 volts grade, cross sectional area 1.50 sqmm 3 core including taking down U/S cable, complete all as specified and directed. |
| 35 | Supply installation, commissioning and testing in replacement, including providing all necessary electrical connection, LT feeder pannel boad (CPRI Approved), outdoor type, double door, compartmentlaised type, factory made out of3.15 mm thick MS sheet with suitable sizehaving hinge opening arrangement in front and back side and bottom frame made out of angle iron of size 50x50x6mm thick and 04 nos legs0.5meter length with cable entry and exit circular hole with cable gland & gasket at bottom complete including painting to all internal and external exposed steel surfaces with powder coating paint (5 stage process) with duly fixed in ground with necessary PCC foundation (1:2:4) type B1, with danger notice plate of 1.6mm thick mild steel sheet, vitereous enamelled (white), with letters, figures and conventional skull and bones in signal red colour, fixing lugs, bolts, screws etc complete and comprising of the following accessories including necessary excavation work for taking out cable loop and refilling the trenches all as directed by the Engr-in-Charge:-(Location: Near S/S No.5) |
| 36 | BUS BAR CHAMBER |
| 37 | (a) Copper bus bar, 1000 Amps, supported on non hygroscopic fibres and brass screws for mounting.– 04 (Four) Nos. |
| 38 | INCOMER |
| 39 | (a) ACB630A Micro processor based adustable type , 415 Volts 4 pole, 50 KA - 01 No (In coming) |
| 40 | OUTGOING FEEDERS |
| 41 | (a) MCCB 320 A Thermal magnetic based Release , 415 Volts 4 pole, 36 KA - 01 |
| 42 | (a) MCCB 200 A Thermal magnetic based Release , 415 Volts 4 pole, 36 KA - 01 |
| 43 | (b) MCCB 100 A Thermal magnetic based Release , 415 Volts 4 pole, 25 KA - 02 |
| 44 | (c) MCCB 160AThermal magnetic based Release , 415 Volts 4 pole, 36 KA - 03No |
| 45 | (d) MCCB 63 A Thermal magnetic based ReleaseThermal magnetic based Release, 415 Volts 4 pole, 16 KA - 01 No |
| 46 | e) Spare space for Two MCCBof 320 Ampwithout MCCB with extension of BUS bar for future expansion |
| 47 | INDICATING DEVICES |
| 48 | (a) LED Indicating lamps for Main Supplyindicating R\", Y\" B\" - Set of 3. |
| 49 | (b) LED Multifunction Meters, Model C Class 1 RS485 Port complete- 01 Nos . |
| 50 | (c) Current Transformer havingRatio 200/5, 5 VA rated burden - 3 Nos |
| 51 | (d) Control MCB - 3 Nos |
| 52 | Supply installation, commissioning and testing in replacement, including providing all necessary electrical connection, LT feeder pannel boad (CPRI Approved), outdoor type, double door, compartmentlaised type, factory made out of3.15 mm thick MS sheetwith suitable size having hinge opening arrangement in front and back side and bottom frame made out of angle iron of size 50x50x6mm thick and 04 nos legs 0.5 meter length with cable entry and exit circular hole with cable gland & gasket at bottom complete including painting to all internal and external exposed steel surfaces with powder coating paint (5 stage process) with duly fixed in ground with necessary PCC foundation (1:2:4) type B1, with danger notice plate of 1.6mm thick mild steel sheet, vitereous enamelled (white), with letters, figures and conventional skull and bones in signal red colour, fixing lugs, bolts, screws etc complete and comprising of the following accessories including necessary excavation work for taking out cable loop and refilling the trenches all as directed by the Engr-in-Charge:-(Location: Near Armoury Bldg ) |
| 53 | BUS BAR CHAMBER |
| 54 | (a) Copper bus bar, 525 Amps, supported on non hygroscopic fibres and brass screws for mounting.– 04 (Four) Nos. |
| 55 | INCOMER |
| 56 | (a) MCCB 320A Thermal magnetic based Release, 415 Volts 4 pole, 36 KA - 01 No (In coming) |
| 57 | OUTGOING FEEDERS |
| 58 | (a) MCCB 250 A Thermal magnetic based Release , 415 Volts 4 pole, 36KA - 01No |
| 59 | (b) MCCB 160A Thermal magnetic based Release , 415 Volts 4 pole, 36KA - 01 No |
| 60 | (c) MCCB 100AThermal magnetic based Release, 415 Volts 4 pole, 25KA - 03 No |
| 61 | (d) MCCB 63 A Thermal magnetic based Release, 415 Volts 4 pole, 16 KA - 01 No |
| 62 | e) Spare space for Two MCCBof 250 Amp without MCCB with extension of BUS bar for future expansion |
| 63 | INDICATING DEVICES |
| 64 | (a) LED Indicating lamps for Main Supplyindicating R\", Y\" B\" - Set of 3. |
| 65 | (b) LED Multifunction Meters, Model C Class 1 RS485 Port complete- 01 Nos . |
| 66 | (c) Current Transformer havingRatio 200/5, 5 VA rated burden - 3 Nos. |
| 67 | (d) Control MCB - 3 Nos |
| 68 | Supply installation, commissioning and testing in replacement, including providing all necessary electrical connection, LT feeder pannel boad (CPRI Approved), outdoor type, double door, compartmentlaised type, factory made out of3.15 mm thick MS sheet of size 1.0m (height) x 1.5 m (width) x 0.5 m (depth) having hinge opening arrangement in front and back side and bottom frame made out of angle iron of size 50x50x6mm thick and 04 nos legs 0.5 meter length with cable entry and exit circular hole with cable gland & gasket at bottom complete including painting to all internal and external exposed steel surfaces with powder coating paint (5 stage process) with duly fixed in ground with necessary PCC foundation (1:2:4) type B1, with danger notice plate of 1.6mm thick mild steel sheet, vitereous enamelled (white), with letters, figures and conventional skull and bones in signal red colour, fixing lugs, bolts, screws etc complete and comprising of the following accessories including necessary excavation work for taking out cable loop and refilling the trenches all as directed by the Engr-in-Charge:-(Location: Near P-426) |
| 69 | BUS BAR CHAMBER |
| 70 | (a) Copper bus bar, 375 Amps, supported on non hygroscopic fibres and brass screws for mounting.– 04 (Four) Nos. |
| 71 | INCOMER |
| 72 | (a) MCCB 250AThermal magnetic based Release , 415 Volts 4 pole, 36 KA - 01 No |
| 73 | OUTGOING FEEDERS |
| 74 | (a) MCCB 100 A Thermal magnetic based Release , 415 Volts 4 pole, 16 KA - 02 No |
| 75 | (b) MCCB 63 AThermal magnetic based Release , 415 Volts 4 pole, 16 KA - 5No |
| 76 | e) Spare space for Two MCCBof 100 Amp without MCCB with extension of BUS bar for future expansion |
| 77 | INDICATING DEVICES |
| 78 | (a) LED Indicating lamps for Main Supplyindicating R\", Y\" B\" - Set of 3. |
| 79 | (b) LED Multifunction Meters, Model C Class 1 RS485 Port complete- 01 Nos . |
| 80 | (c) Current Transformer havingRatio 200/5, 5 VA rated burden - 3 Nos. |
| 81 | (d) Control MCB 6-32 Amp- 3 Nos |
| 82 | M&L for cable route indicator for cable route marker ,made out of cast iron round shape of 100mm dia,with supporting length of GI flat 20mm wide and 6mm thickand 750mm long ,duly marked with word such as LT Cable /1.1KV as directed ,duly painted with two coats of super enamel silver colour over a coat of primer ,including grouting in ground 300mm x300mm 300 deep with and including PCC 1:2:4(Type B1) complete all as specified and directed. |
| 83 | S&f in repairenclosed Automatic transfer switch , Frame 2 160Amp, double break contact syustem offering high short time withstand , suitable for aluminium termination ,adjustable time delay (0.1sec to 3 hourssuitable for 3 phase as well as 1 phase and protected with UV/OV, Phase sequence, single phasing, frequency, complete all as specified and directed. |
| 84 | M&L for Earthing complete with GI earth plate electrode of size 600x600x6 mm thick buried directly in ground with earth pit not less than 2.25 meter deep below ground level with top edge of plate not less than 1.5 meter below normal ground level connected to GI earth strip of size 32 x 6 mm earth lead by means of nuts, bolts, check nuts, washers of galvanised iron as steel,protected by galvanized iron pipe 40mm bore (Medium grade) allas directed including cement concrete (1:3:6) type C-1 earth pit with precast RCC (1:1.5:3) type A-1 cover slab of size 42 x 42 x10cm thick reinforced with 8mm dia TMT bars @ 15 cm c/c both ways with 10mm dia mild steel round bar of 30 cm long, bent to shape as lifting handle, funnel,wire mesh, 20 mm bore galvanized iron pipe (medium grade) for watering, charcoal or coke and salt in alternate layers with necessary earth work in soft/loose soil complete all as shown in electrical plate No 3 of SSR Part I including testing on completion all complete as specified and directed. (GI strip upto 7.5m including testing consider in this item). |
| 85 | Materials and Labour for rendering 8 mm thick, cement plaster, in cement mortar (1:4) mixed with water proofing compound as per manufactures instructions over and including 12 mm thick backing coat in cement mortar (1:4) on fair faces of brick work or concrete surface in walls, complete all as specified and directed.Note: - (Water proofing compound will be measured and paid separately) |