| 1 | Renovation and upgradation of Polyhouse Facility in Plant Virology Laboratory |
| 2 | Removing iron pipe railing having wooden R.C.C. or C.C> or iron post and stacking the materials as directed etc. complete |
| 3 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction Engineer-in-charge. In cement mortar |
| 4 | Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 meters lead as per direction of Engineer-in-charge |
| 5 | Providing and laying in position ready mixed or site batched design mix cement concrete for plain cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana/Ordinary Portland / Portland Slag cement, admixtures in recommended proportions as per IS:9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering and finishing as per direction of the engineer-in-charge; for the folloeing grades of concrete. Concrete of M15 grade with minimum cement content of 240 kg/cum |
| 6 | Providing and fixing heavy duty inter locking concrete Rubber mould glossy paving blocks of 60 mm thickness of having a strength of 400 kilogram/Sq.cm. of approved quality and shape on a bed of crushed sand of 25 to 30 mm thick including skirting joints and cleaning etc. complete. (using 100% crushed sand) |
| 7 | Filling in plinth with moorum |
| 8 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo Mechanically Treated Bar of Grade Fe-500D or More |
| 9 | Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete |
| 10 | Providing dry/trap/granite/quartzile/ gneiss rubble stone soling 15cm to 20cm thick including hand packing & compacting etc complete |
| 11 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6coarse sand) |
| 12 | 12 mm cement plaster of mix : 1:4 (1 cement: 4 fine sand) |
| 13 | Wall painting with acrylic emulsion paint, having VOC content less than 50grams/ liters, of approved brand and manufracture, including applying additional coats wherever required, to achieve even shade and colour : one coat |
| 14 | Providing Galvanised steel work in trusses, other similartrussed purlins and members with all bracing, gusset plates etc. as per detailed designs and drawings or as directed including cutting, fabricating, hoisting, erecting fixing in position, Making riveted/botled/welded connection and one coat of anticorrosive paint and over it 2 coats of oil painting approved quality and shade etc. complete. (for detailed justification refer SSR Item No. 23.04) |
| 15 | Supply and installation of translucent roof with DPI Flux standing seam multicell polycarbonate panel system. The system with complete assembly of co extruded UV protected multicell panels incorporated into a complete system. Co-extruded UV protected polycarbonate panel system of min 6 mm thick of 900 mm (min.) width with angular daylighting concept. Panels shall have minimum six layers with truss bridge design for higher flexibility & strength. Panels with all fixing accessories to ensure best performance for wind uplift, vibration, oil canning and visual appearance. Panels shall be manufactured with vertical standing seam at both sides of the panel. Panels shall be fixed on urlin with snap on connectors wiith double tooth grip lock locking mechanism and will be secured on GS structure (will be paid Separately) with 3 One Numbers self-drilling screws & trapezoid SS fasteners holding the base of the standing seam offering best stability having a pull-out load of min. 7000N (7KN) tested as per ISO 6892:1998 and IS 1608:2005, as per design requirement. Panels must satisfy Dart drop impact test as per IS 14443-97 shall show no sign of breakage on Polycarbonate sheets which have been exposed to UV for min. of 500 Hours as per ASTM G 155. Panels shall not have Yellowness Index as per ASTM D 1925 of 15 units when tested on a sample exposed to UV for 500 Hours as per ASTM G 155. U value shall not be more than 1.6 W/m2K as per EN ISO 10077-2:2018. Panel shall be with additional End cap/Aluminium U/F profile/ Glazing Bar for ends as required and including Door fitting. Panel shall be fixed over GS structural steel/GS purlin (paid separately) conforming to the detail technical specifications as per approved architectural drawings. Trained and factory authorized labour with supervision to complete the entire panel installation as per drawing & direction of the engineering in charge. Colour: As per Approval. Approval Make: FLUX by DPI Daylighting or approved equivalent The 6 mm thick panels shall be used for a roofing height of upto 15 mtrs..(for detailed justification refer SSR item No. 51.187) |
| 16 | Supply and installation of translucent roof DPI Flux standing seam multicell polycarbonate panel system. The system with complete assembly of co extruded UV protected multicell panels incorporated into a complete system. Co-extrude UV protected polycarbonate panel system of min 8 mm thick of 900 mm (min.) width with angular daylighting concept. Panels shall have minimum six layers with truss bridge design for higher flexibility & strength. Panels with all fixing accessories to ensure best performance for wind uplift, vibration, oil canning and visual appearance. Panels shall be manufacture with vertical standing seam at both sides of the panel. Panels shall be fixed on Purlin with snap on connectors with double tooth grip lock locking mechanism and will be secured on GS structure (will be paid Separately) with 3 One Numbers self-drilling screws & trapezoid SS fasteners holding the base of the standing seam offering best stability having a pull-out load of min. 7000N (7KN) tested as per ISO 6892:1998 and IS 1608:2005, as per design requirement. Panels must satisfy Dart drop impact test as per IS 14443-97 shall show no sign of breakage on Polycarbonate sheets which have been exposed to UV for a min. of 500 Hours as per ASTM G 155. Panels shall not have Yellowness Index as per ASTM D 1925 of 15 units when tested on a sample exposed to UV for500 Hours as per ASTM G 155. U value shall not be more than 1.6 W/m2K as per EN ISO 10077-2:2018. Panel shall be with additional End cap/Aluminium U/F profile/ Glazing Bar for ends as required and including Door fitting. Panel shall be fixed over GS structural steel/GS purlin (paid separately) conforming to the detail technical specifications as per approved architectural drawings. Trained and factory authorized labour with supervision to complete the entire panel installation as per drawing & direction of the engineering in charge. Colour: As per Approval. Approved Make:FLUX by DPI Daylighting or approved equivalent The 6 mm thick panels shall be used for a roofing height of upto 15 mtrs..(for detailed justification refer SSR Item No.51.187) |
| 17 | Providing and fixing H.D.P container one piece moulded water tank made out of high density polythyler and built corrugated inclusive of delivery up to destination hoisting and fixing of accessories such as inlet, otlet overflow pipe inclusive of all tanks capacity between 200 to 1000 liters |
| 18 | Providing & Fixing Evaporative Fan 2 nos & Pad Cooling System *1.5m.H x 6 m. W x 100mm thick in Evaporative CELDEC cooling pad complete* All external surfaces of the pad should have filter screens of a least a 40 x 30 mesh net covering made from durable plastic material. *All necessary framing material made with Extruded Profile of Aluminium required top bottom and side frame distribution & returning piping*Gutters. Down spout end caps & drip pan, plumbing kit, pump 440 volt. 3 phae 50 cycles, Drilled PVC piping cap, pad retainer, all suspension hardware. *Metal flashings as required to seal pad to vent opening, 6\" thick evaporative cooling pad material.*Aluminium Profiles: Tray Sides, Top Etc. *Plastic Profiles:Water Distributin tray. b) Leading kit with pipeline upto frame, bypass, filter flush system etc, Open well submersible 1HP, 3Ph, d) Frame for the above cooling pad with top water distribution and bottom gutter, aluminium, complete as per direction of Engineer Incharge |
| 19 | Providing & Fixing micro Foogong system with all necessaries and Fitment main and submain PVC pipe, comtrol valve, Fushcap with 4 way foggers and Pump 1 HP heavy duty and filter. Humidity control upto 85% + 5% by providing misting nozzles (Micro Mist / fogger with LPD) hanging type having water discharge 28 LPH each Nozzle. complete as per direction of Engineer Incharge |
| 20 | Stone work (machine cut edges in veneer work) for wall lining upto 10 m height, backing filled with a grout of 12 mm thick cement mortar 1:3 (1 cement : 2 stone dust), including grinding with hand grinder on joints, rubbing and polishing complete. (To be secured to the backing and the sides by means of cramps and pins which shall be paid for separately). |
| 21 | Providing & Fixing Micro Processor based control panel including Monitor panel, lights, Temperature, humidity controller system & total electrical fittings in polyhouse shed. A) Technical feature of Photoperiodic Timer:- Cycle 24 hrs minimum ON/OFF period 30 minutes, Accuracy : + 10sec/day, Input : 200-240 VAC, phase - Single, Ambiebt: 5 ̊ C to 45 ̊ C, RH upto 85% normally, b) Technical feature of Temperature control system:- Temp. Range : 0.1 to 59.9̊ C accuracy : + 1 ̊ C, Hysteresis: 0.4 ̊ C with sensor probe Pt-100 sensor cord 5 meter. Inputs:200-240 VAC (110 VAC available on demand) phase - single, Ambient: 5 ̊ C to 45 ̊ C, RH up to 85% normally, c) Relative Humidity Control system: It Maintains RH in the range of + 4%, Range: 40% to 85%, Real RH: +2% +1% digit (at 45%), Input:220 V AC available on demand) phase single, Ambient: 5 ̊ C to 45 ̊ C, upto 95% complete as per direction of Engineer in Charge |
| 22 | Supplying and providing Bio Safety measures, a) Fan & blower fitted with 40/40 mono foil mesh netting b) Doors fitted with air retention brushes, c) Entrance through double door (air Lock type) system, including electrical work complete as per directed by Engineer Incharge |
| 23 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 70 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/trusses/pole or laid in provided trench/pipe as per specification no. CB-LT/AL |
| 24 | Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved make, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. Size of Tile 600 x 600 mm, as per directed by Engineer In charge |
| 25 | Supplying and erecting PVC trunking (PVC casing-n-capping) of size 20 mm with accessories on wall/ceiling as per specification No: WG-MA/CON. |
| 26 | Supplying and erecting PVC trunking (PVC casing-n-capping) of size 40 mm with accessories on wall/ceiling as per specification No: WG-MA/CON. |
| 27 | Supplying and erecting mains with 2x2.5 sq. mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No:WG-MA/BW |
| 28 | Supplying and erecting mains with 2x4 sq. mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No:WG-MA/BW |
| 29 | Supplying and erecting mains with 2x6 sq. mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No:WG-MA/BW |
| 30 | Supplying and erecting modular type switch 6A / 10A duly erected on provided plate and box with wiring connections complete |
| 31 | Supplying and erecting modular type switch 16A duly erected on provided plate and box with wiring connections complete |
| 32 | Supplying and erecting modular type D.P. switch 32A with indicator duly erected on provided plate and box with wiring connections complete |
| 33 | Supplying and erecting modular type 3 pin 6 / 16A multi socket with safety shutter, duly erected on provided plate and box with wiring connections complete |
| 34 | Supplying and erecting PVC Surface modular switch box with double mounting & front plate for 8 module complete duly connected |
| 35 | Supplying and erecting PVC Surface modular switch box with double mounting plate for 12 module duly erected |
| 36 | Supplying, erecting & marking FPMCB 6A to 32A, with rated short-circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB |
| 37 | Supplying and erecting LED square / circular Max. 7W down lighter/ Panel Light Having pressure die-cast aluminium housing, polystyrene diffuser having system lumens output of Min. 770 Lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD<10%, p.f.>0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, having mounting arrangements with board for surface type or spring loaded mounting clips complete with 3 years warranty |
| 38 | Supplying and erecting LED square / circular Max. 25W down lighter/ Panel Light Having pressure die-cast aluminium housing, polystyrene diffuser having system lumens output of Min. 2750 Lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle120 deg., max. ripple of 5%, THD<10%, p.f.>0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, having mounting arrangements with board for surface type or spring loaded mounting clips complete with 3 years warranty |