| 1 | Supply and Install water cooler storage type, ISI marked, eletrict driven 230 Volts, 50 Hz, single phase supply complete with all internal accessories, stainless steel body and tank, power saving in PUF insulation, adjustable cold water thermostat, 10 degree to 25 degree centigrade auto cut off facility, overlead protection, stainless steel front panel, extended plastic legs, eco-friendly version with non CFC refrigerant, energy efficient conforming to relevant IS and PF shall not be less than 0.85 compressor and approx storage capacity of 150 litres and nominal cooling capacity of 150 litres per hours including marking CA No. and MES No.on with permanent marker style and size complete all as specified and directed. |
| 2 | Supply and Install water cooler storage type, ISI marked, eletrict driven 230 Volts, 50 Hz, single phase supply complete with all internal accessories, stainless steel body and tank, power savingPUF insulation, adjustable cold water thermostat, 10 degree to 25 degree centigrade auto cut off facility, overlead protection, stainless steel front panel, extended plastic legs, eco-friendly version with non CFC refrigerant, energy efficient conforming to relevant IS and PF shall not be less than 0.85 compressor and approx storage capacity of 80 litres and nominal cooling capacity of 150 litres per hour including marking CA No. and MES No. on with permanent marker style and size complete all as specified and directed. |
| 3 | Supply, installations of split type AC indoor / outdoorcomplete with cordless remote control unit and with in built air ioniser and plasma filter for better indoor air quality with minimum 3 star rating and EER 3.2 of capacity 1.5 Toncomplete as specified and as directed.Note:- (a) Suitable piping shall be provided of adequate length of size 5/8\" for draining of condensate water from indoor unit. Cost of same shall deemed to be included in quoted rate (b) Cost for Metallic bracket and nut bolt for fixing indoor and outdoor unit including necessary cutting grouting in walls by cutter and making good the surface in CM 1:3 and to the original finishes (white wash/colour wash/Distemper) shall deemed to be included in quoted rate. (c) Contractor shall submit original purhase voucher and Warranty card.Make : Hitachi /Carrier / LG / Voltas / Daikain |
| 4 | Supply, installations of split type AC indoor / outdoor complete with cordless remote control unit and with in built air ioniser and plasma filter for better indoor air quality with minimum 3 star rating and EER 3.2 of capacity 2.0 Toncomplete as specified and as directed.Note:- (a) Suitable piping shall be provided of adequate length of size 5/8\" for draining of condensate water from indoor unit. Cost of same shall deemed to be included in quoted rate (b) Cost for Metallic bracket and nut bolt for fixing indoor and outdoor unit including necessary cutting grouting in walls by cutter and making good the surface in CM 1:3 and to the original finishes (white wash/colour wash/Distemper) shall deemed to be included in quoted rate. (c) Contractor shall submit original purhase voucher and Warranty card.Make : Hitachi /Carrier / LG / Voltas / Daikain |
| 5 | Supply, installing, commissioning and testing frost free refrigerator electric driven single phase 220 volts, AC 50 Hz,of capacity not less than 300 Itrs with BEE approved, min 3 stardouble door (5 in 1 convertible Freezer), stablizer free operation, DC inverter technology. LED display, tempered glass self, deodorizer and with fruit & vegitable drawer complete all as specified and as directed.Note:- Contractor shall submit original purhase voucher and Warranty card.Make : Samsung / Voltas / LG / Whirlpool |
| 6 | Supply, installing, commissioning and testing frost free refrigerator electric driven single phase 220 volts, AC 50 Hz,of capacity not less than 195 Itrs with BEE approved, min 3 star rating, single door, stablizer free operation, DC inverter technology. LED display, tempered glass self, deodorizer and with fruit & vegitable drawer complete all as specified and as directed.Note:- Contractor shall submit original purhase voucher and Warranty card.Make : Samsung / Voltas / LG / Whirlpool/ Haier |
| 7 | Supply. Installing, comissioning and testing of hard top deep freezer Single phase 220V, 50 Hz of 300/320 ltrs capacity having double door, min 3 star rating , direct cool evaporator type, refrigerant, caster lock, Temp range -18 ºC to -26 ºC, analogue temp setting, magnetic door gasket, caster wheel inside alluminium cladoing, outside body - PCM plastic material etccomplete all as specified and as directed.Make : Blue Star / Voltas / LG / Godrej |
| 8 | Supply. Installing, comissioning and testing of hard top deep freezer Single phase 220V, 50 Hz of 200/205 ltrs capacity having double door, min 3 star rating, direct cool evaporator type, refrigerant, caster lock, Temp range -18 ºC to -26 ºC, analogue temp setting, magnetic door gasket, caster wheel inside alluminium cladoing, outside body - PCM plastic material etccomplete all as specified and as directed.Make : Blue Star / Voltas / LG / Godrej |
| 9 | Taking down Aluminium/copper sub main wiring and making good disturbed surfaces to match with the existing surface roof/wall/floor complete all as specified and as directed . |
| 10 | S&F in replacement of metal plug & socket DB with metal plug and MCBs dobule pole and neutral enclosere with a two pin earth plug and socket suitable for 20 Amp complete with one single pole MCB complete all as specified and directed. |
| 11 | M&L for sub main wiring with two single core 4 Sqmm FRLSH copper conductor PVC insulated and unsheathed cableincluding PVC conduit medium grade (appropriate size) concealed in wall for sub main connection including 4 Sqmm FRLSHinsulated multistranded unsheathed copper conductor used as a earth wire to common earth and connection to earth dolly all as specified. (Note :- Two runs of 4 sqmm FRLSH and one run of 4 sqmm FRLSH copper conductor shall be measured as one unit length.) |