| 1 | Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as10 sqm on plan including disposal of excavated earth, leadupto50meterand lift upto 1.5m, as directed by Engineer-in-Charge. All kinds of soil : |
| 2 | Earth work in bulk excavation by manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 m2 on plan) including disposal of excavated earth Earth work in bulk excavation by manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 m2 on plan) including disposal of excavated earth lead upto 50 meters and lift upto 1.5 m, as directed by Engineer-in-Charge. |
| 3 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with: 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) |
| 4 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with:1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size). |
| 5 | Reinforced cement concrete work in walls (any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts upto floor five level including curing but excluding cost of centering shuttering, finishing and reinforcement. 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 6 | Providing and laying in position specified grade of reinforced cement concrete including curing but excluding the cost of centering, shuttering, finishing and reinforcement. All works upto plinth level1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 7 | Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15°, landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto five level including curing but excluding the cost of centring, shuttering, finishing and reinforcement with 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 8 | Centering and shuttering including strutting, propping etc. and removal of form for: Lintel, beams, plinth beams, girders, bressumers and cantilevers. |
| 9 | Centering and shuttering including strutting, propping etc. and removal of form for: Suspended floors, roofs, landings, balconies and access platforms. |
| 10 | Centering and shuttering including strutting, propping etc. and removal of form for: Foundations, footings, bases of columns etc. for mass concrete |
| 11 | Centering and shuttering including strutting, propping etc. and removal of form for: Columns, pillars, piers, abutments, posts and struts. |
| 12 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level : Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 13 | Brick work with common burnt clay (non-modular) bricks of class designation 7.5 in foundation and plinth including curing in :Cement mortar 1:4 ( 1 cement : 4 coarse sand) |
| 14 | Extra for brick work with common burnt clay bricks/cement concrete bricks in superstructure above plinth level upto floor five level |
| 15 | Structural steel work in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 16 | Providing and fixing precoated galvanized iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. |
| 17 | Supplying and filling in plinth with fine sand under floors including, watering, ramming, consolidating and dressing complete |
| 18 | Half brick masonry with common burnt clay (non-modular) bricks of class designation 7.5 in foundations and plinth including curing in Cement mortar 1:4 ( 1 cement : 4 coarse sand) |
| 19 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia and length (hold fast lugs or with dash fasteners shall be paid for separately):Second class kail wood |
| 20 | Providing and fixing ISI marked flush door shutters conforming to IS: 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters; With ISI marked M.S. pressed butt hinges bright finished of required |
| 21 | Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete. : 200X10 mm |
| 22 | Providing and fixing bright finished brass handles with screws etc. complete : 125 mm |
| 23 | Providing and fixing ISI marked oxidized M.S. sliding door bolts with nuts and screws etc. complete :250x16 mm |
| 24 | Providing and fixing glazed shutters for doors, windows and clerestory windowsusing 4mm thick float glass panes including ISI marked M.S. pressed butthinges bright finished of required size with necessary screws. Second class Kail wood, 30mm thick |
| 25 | 15mm Cement plaster on the rough side of single or half brick wall of mix 1 : 4 ( 1 cement : 4 coarse sand) |
| 26 | Providing and applying Plaster of Paris putty of 2mm thickness over plastered surface to prepare the surface even and smooth complete. |
| 27 | Finishing wall with premium acrylic smooth exterior paint with silicone additives of required shade on New work (two or more coats applied @ 1.43 liter/10sqm over and including priming coat of water exterior paint applied @ 2.20kg/10sqm) |
| 28 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth and curing complete. |
| 29 | Dry stone pitching 22.5 cm thick including supply of stones and preparing surface complete. |
| 30 | Chequerred precast cement concrete tiles 22mm thick in footpath and courtyard, jointed with neat cement slurry mixed with pigment to match the shade of the tiles, including rubbing, cleaning and curing complete, on 20 mm thick bed of cement mortar 1:4 ( 1 cement : 4 coarse sand) .Ordinary cement without any pigment. |
| 31 | Providing and fixing hard board sheet ceiling of approved quality with necessary nails etc. complete (frame work to be paid for separately)Standard Quality board, 4.5 mm Thick |
| 32 | Providing and fixing plain, square edged wooden beading 65x12 mm section with screws of approved quality for ceiling. 1st class kail wood |
| 33 | Applying priming coats with primer of approved brand and manufacture,having low VOC (Volatile Organic Compound) content.With ready mixed pink or grey primer on wood work (hard and soft wood) having VOC content less than 50 grams/ liter |
| 34 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two or more coats on new work. |
| 35 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados over 12 mm thick bed of cement mortar 1:3 ( 1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 36 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622 of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1cement :4 coarse sand) including grouting the joints with white cement and matching pigments etc. complete. Size of tile 500x500 mm |
| 37 | Providing and fixing G.I. pipes complete with G.I. fittings and clamps, including cutting and making good the walls etc.: Internal work-Exposed on wall15 mm dia. nominal bore; medium |
| 38 | Providing and fixing G.I. pipes complete with G.I. fittings excluding trenching and refilling etc. (external work) :15 mm dia. nominal bore; medium |
| 39 | Providing and fixing brass bib cock of approved quality: 15 mm nominal bore |
| 40 | Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (new work) : 15 mm nominal bore |
| 41 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank |
| 42 | Providing and fixing brass stop cock of approved quality.15 mm nominal bore |
| 43 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete |
| 44 | Providing and fixing uplasticized PVC connection pipe with brass unions, 30 cm length,15 mm nominal bore |
| 45 | Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required:-White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer |
| 46 | Providing and fixing CP Brass Single lever telephonic wall mixer of quality & make as approved by Engineer in charge. 15 mm nominal dia |
| 47 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. |
| 48 | Constructing soak pit 1.20x1.20x1.20m filled with brickbats including S.W. drain pipe 100 mm diameter and 1.20m long complete as per standard design. |
| 49 | Providing & fixing White vitreous china water closet squatting pan(Indian type) along with “S” or “P” trap including dismantling of old WC seat and “S” or “P” trap at site complete with all operations including all necessary materials, labour and disposal of dismantled material i/c malba, all complete as per the direction of Engineer-in charge.Long pattern W.C Pan of size 580x440 mm |
| 50 | Providing and fixing P.V.C low level flushing cistern with manuallycontrolled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete:10 liter capacity -White |
| 51 | Providing and fixing soil, waste and vent pipes : 100 mm dia. Sand cast iron S and S pipe as per IS:1729 |
| 52 | Providing and fixing soil, waste and vent pipes : 75 mm dia. Sand cast iron S and S pipe as per IS:1729 |
| 53 | Providing and fixing bend of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete: 100 mm dia. Sand cast iron S and S as per IS:1729 |
| 54 | Providing and fixing bend of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete: 75 mm dia. Sand cast iron S and S as per IS:1730 |
| 55 | Providing and fixing plain bend of required degree: 100 mm dia. Sand cast iron S and S as per IS:1729 |
| 56 | Providing and fixing plain bend of required degree:: 75 mm dia. Sand cast iron S and S as per IS:1729 |
| 57 | Providing and fixing collar :100 mm.Sand cast iron S and S as per IS:1729 |
| 58 | Providing and fixing collar :75 mm.Sand cast iron S and S as per IS:1729 |
| 59 | Providing lead caulked joints to sand cast iron / centrifugally cast (spun) iron pipes and fittings of diameter: 100 mm. |
| 60 | Providing lead caulked joints to sand cast iron / centrifugally cast (spun) iron pipes and fittings of diameter: 75 mm. |
| 61 | Providing and filling the joints with spun yarn cement slurry and cement mortar 1:2 (1 cement : 2 fine sand) in S.C.I / C.I pipes75 mm dia. Pipe |
| 62 | Providing and filling the joints with spun yarn cement slurry and cement mortar 1:2 (1 cement : 2 fine sand) in S.C.I / C.I pipes 100 mm dia. Pipe |
| 63 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C waste fittings complete: Flexible pipe 32 mm dia |
| 64 | Providing and fixing trap of self-cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors :100 mm inlet and 75 mm outletSand cast iron S and S as per IS:1729 |
| 65 | Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone- III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarsesand (zone- III) : 8 graded stone aggregate 40 mm nominal size),inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4graded stone aggregate 20 mm nominal size) finished with a floatingcoat of neat cement complete as per standard design : Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 66 | Providing and fixing PTMT grating of approved quality and colour; Circular type; 100 mm nominal dia. |
| 67 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable insurface/recessedsteelconduit,withmodularswitch,modular plate, suitableGI boxand earthingthe pointwith 1.5 sq.mmFRLS PVC insulated copper conductor single core cable etc. as required. Group A |
| 68 | Wiring fortwin control lightpointwith 1.5sq.mm FRLSPVC insulatedcopper conductorsinglecorecablein surface/ recessed steel conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm.FRLS PVC insulated copper conductor single core cable etc .as required. |
| 69 | Supplying and fixing brass batten/ angle holder including connection etc. as required. |
| 70 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles intheexistingMCBDBcompletewithconnections,testingand commissioning etc. as required.Single pole 6 A |
| 71 | Exhaust fan |
| 72 | GST@18% |