| 1 | Excavation in foundation in ordinary soil (Loam clay or sand ) including lift upto 1.50M and lead upto 30M, and including filling watering and ramming of excavated earth into the trenches or into the space between the building and the sides of foundation trenches or into the plinth and removal and disposal of surplus earth as directed by the Engineer-in-incharge upto ta distance of 30M from the foundation trenches. S.I.No. 251(a) |
| 2 | Concrete with 4 cm. guage stone ballast, Fine sand of 1.25 F.M. and cement, in proportion of 12:6:1 in foundation and under floors including supply of all materials, labour Tools & plants etc.required for proper completion of the work. |
| 3 | Providing and injecting chemical for preconstructional antitermite treatment and creating and chemical barrier under and around the column pits wall trenches basement excavation top surface in plinth filling juction of wall and floor, along the external per meter of binding expansion joints surrounding of pipes and conduit etc. complete (plinth area of the building at ground floor only shall be measured as per I.S. 6313 (part ll 1981) Aldrine emulsifiable concentrate or any other approved material such as Hepthachlor of chlordance of chemical emulsion shall be as follows :- Treatment of surface of plinth filling 5 liters per sqm |
| 4 | M-150 Brick work in one cement and four corse sand (1:4 ) in foundation and plinth including supply of all materials labour, T&Petc. Reqd. For proper completion of the work |
| 5 | M-150 Brick work in one cement and four corse sand (1:4 ) in superstructure including necessary cutting & moulding of brick including supply of all materials labour, T&P etc. Reqd. for proper completion of the work. |
| 6 | R.C.C. Work with cement approved coarse sand and 2 cm. gauge approve stone grit in proportions of R.C.C column in 1:2:4 excluding supply of reinforcement and its bending but including its fixing and binding the same with 24 B.W.G.G.I. binding wire and including necessary, centering & shuttering etc. and supply of all material, labour, tools & plants etc. required for proper completion of the work including cost of binding wire. The rate excludes making of drip course which shall be paid extra. |
| 7 | R.C.C. Work with cement approved coarse sand and 2 cm. gauge approve stone grit in proportions of 1:2:4 in Light beam having spans upto 6M excluding supply of reinforcement and its bending but including its fixing and binding the same with 24 B.W.G.G.I. binding wire and including necessary, centering & shuttering etc. and supply of all material, labour, tools & plants etc. required for proper completion of the work including cost of binding wire. The rate excludes making of drip course which shall be paid extra. |
| 8 | R.C.C. Work with cement approved coarse sand and 2 cm. gauge approve stone grit in proportions of R.C.C Slab 1:2:4 in excluding supply of reinforcement and its bending but including its fixing and binding the same with 24 B.W.G.G.I. binding wire and including necessary, centering & shuttering etc. and supply of all material, labour, tools & plants etc. required for proper completion of the work including cost of binding wire. The rate excludes making of drip course which shall be paid extra. |
| 9 | MS (Tor steel or plain)in plain work such as RCC or RB work including binding for proper shape and including supply of steel & its wastage bend, hooks and authorized overlapping shall be measured and including cost for binding wire. SINo. 504 |
| 10 | 12 mm thick cement plaster with cement and corse sand mortar 1:4 over brick work thickness not less than 1cm including of all work complete |
| 11 | Finishing wall with weather coat paint of approved make and quality on new surface with two coat to give even shade including supply of all material, labour, tools and plants etc required for proper completion of the work. |
| 12 | providing wall putty on new surface with approved quality material of Berger/jk/Birla or similar make 2 coat as per si no- 15.24 New item. |
| 13 | MS or Iron in Plain work in heavy size such as chokhat Trusses, Built up Gates, Door Frame, Grill including drilling holes, riveting, binding for proper shape and including supply of steel & its wastage, bend, hooks, steel bolt, Nuts etc and their fixing and including supply of all material, labour, tools and plants etc required for proper completion of the work. S.I.No. 503 |
| 14 | 10 cm thick (average) mud phaska of damped brick earth on roofs laid to slope consolidated and plastered with 25 mm thick mud mortar mixed with bhusa @ 35 kg per cum of earth and gobri leaping with mix 1:1 (1 clay : 1 cow dung) and covered with flat tile bricks, grouted with cement mortar 1:3 (1 cement : 3 fine sand) mixed with 2% of integral water proofing compound by weight of cement and finished neat:With common burnt clay F.P.S.(non modular) brick tile of class designation 10 |
| 15 | Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density complete. as per Technical Specification Clause 401 |
| 16 | supply & Laying of 80mm thick precast cement concerete I-shape or zigzag interlocking paver block ISI Mark conferming to IS 15658-2006 with top layer of minimum 8mm thickness having plan dimension 200x(160+115mm) of O.P cement, smooth high gloss finish, skid resistant,manufactured from rubber moulds through vibrocompression mechanism. The compressive strength of concrete paver block shall not be less than 30Mpa (M-30) and weight 5Kg per no. Including cost of material and with a blankey layer of 4.00cm thick fine sand , labour,T & P etc required for proper completion of the work as directed by Engineer-in-charge. |
| 17 | 2.5 cm thick 1:2:4 plain cement concrete floor with cement concrete floor with cement approved coarse sand and 2 cm graded approved stone grit laid in panels finished with 3mm |
| 18 | Cement Concrete with 20mm gauge approved stone ballast, coarse sand,and cement in the proportion 4:2:1 including supply of all material, labour, tools and Plants etc. requared for proper complition of the work. |
| 19 | Wiring point for light with 1.5 sq.mm FR P.V.C insulated multistrand single core copper cunductor cable in P V C cond-uit pipe part cocealed in wall & partly laid in slab along with the reinforcement before concreting complete with 14 S.W.G. copper earth continuity wire & piano type switch and ceiling rose/angle/batten holder on 3mm thick phenolic laminated backelite sheet etc. complete in all respect.including matching color wash. |
| 20 | Wiring point plug with 1.0 sq.mm FR P.V.C insulated multistrand single core copper cunductor cable in PVC conduit partely conceted in wall & partly laid in slab along with the reinforcement before concreting complete with 1.5sq mm FR PVC . insulated multistrand copper cunductor cable as earth wire drawn inside and piano type switch and ceiling rose/angle/batten holder on 3mm thick phenolic laminated backelite sheet etc. complete in all respect.including matching color wash.141C |
| 21 | Supply and fixing of recess/Surface/ Pendent mounting round 6 Watt 8 Watt LED Down Lighter having Powder coated die cast aluminium housing with heat sink, diffuser / Reflector and driver set complete in all respect |
| 22 | Add 18 % GST Amount Please Enable Macros to View BoQ information |