| 1 | Taking down cement plaster of any description onbrick or stone walls from any height including racking out joints, hacking for key, scrubbing down with water etc., complete all as specified and directed. |
| 2 | M&L, 15mm thick rendering in cement mortar 1:4, on other than fair faces of brick or concrete surfaces, in any height, finished even and smooth without using extra cement complete all as specified and directed. |
| 3 | M&L, 15mm thick rendering in cement mortar 1:6, on other than fair faces of brick or concrete surfaces, in any height, finished even and smooth without using extra cement complete all as specified and directed. |
| 4 | M&L, 5mm thick rendering in cement mortar 1:3, on ceilings of concrete surfaces, in any height, finished even and smooth without using extra cement complete all as specified and directed. |
| 5 | M&L, preparation of plastered surfaces of walls and applying water proof external wall care putty, including rubbing/grinding with sand paper and making surface even and smooth to receive external emulsion and applying two coats of weather proof anti algal exterior acrylic emulsion paint (100% acrylic), premium quality, over a coat of primer all as per manufacturer\"s instruction complete all as specified and as directed. |
| 6 | M&L, preparation of newly plastered ceiling and wall surfaces and applying two coats of OBD over a coat of 1mm thick putty complete all as specified and directed. |
| 7 | Complete removal of existing treatment from external / internalsurfaces of walls , scrapping, rubbing/wire brushing, sand papered and watering with jet etc., and applying |
| 8 | M&L applying one coat of water proof wall care putty, 1.5 mm thick (average) including rubbing/grinding with sand paper and makingsurface smooth and evencomplete all as specified and as directed. |
| 9 | M&L applyinga coat of alkali resistantprimer onwall surfaces all as per manufacturer\"s instruction complete all as specified and as directed. |
| 10 | Preparation of old plastered surfaces of walls/ ceilings including cornices, pilasters etc.,complete all as specified and directed. |
| 11 | M&L, forapplying one coat of distemper oil emulsion on walls/ceiling complete all as specified and directed. |
| 12 | M&L applying two coats of distemper oil emulsion on walls/ ceiling , white or tintedcomplete all as specified and as directed. |
| 13 | M&L, preparation of old painted wooden surfaces of any description, not otherwise described, over 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed. |
| 14 | M&L, preparation of old painted steel surfaces of any description, over 10cm in width or girth not otherwise described and applying one coat of synthetic enamel paint complete all as specified and as directed. |
| 15 | M&L applyingtwo coats of weather proof anti algal exterior acrylic emulsion paint (100% acrylic), premium quality on exernal surfaces of walls at any height , all as per manufacturer\"s instruction complete all as specified and as directed. |
| 16 | M&L, preparing old plastered surfaces of walls, ceilings, cornices, soffits of slabs and chajjas fins and facias etc., and applying one coat of weather proof anti algal exterior acrylic emulsion paint (100% acrylic), premium quality all as per manufacturer\"s instruction complete all as specified and directed. |
| 17 | M&L, French polishing on surfaces of any description, width or girth including cleaning and preparing the surface including a coat of wood filler on old works with one or more coats complete all as specified and as directed. |
| 18 | M&L, Writing letters or figures (Block Roman, Italic or Indian) not exceeding 30cm high using synthetic enamel paint of approved tint complete all as directed. |
| 19 | S&F in repairs, vitreous china wash hand basin white 550x400mm of size including cutting for and pinning in ends of brackets or erecting stand including brackets, PVC waste pipe and coupling of suitable size including removal of debries off the premises complete all as directed |
| 20 | S&F in repairs, stainless steel sink 1mm thick kitchen or laboratory with plugs, washers and waste pipes; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 600 x450mm with bowl size 410mm x 330mm x 160mm complete all as specified and directed. |
| 21 | S&F in repairs, bevelled edge mirror, 600mm x 450mm, of selected quality glass, mounted on 6mm thick commercial plywood and fixed to woodenplugs with chromium plated brass screws and cup washers, complete all as specified and directed. |
| 22 | S&F in repairs, stainless steel plate rack of 0.63mm thick, of size 36\" x 36\" x 10\" load capacity not less than 30Kg complete all as specified and directed. |
| 23 | S&F in repairs, plastic water closet seat cover, white, closed pattern with recessed bottom and cover aluminized hinging device complete all as specified and directed. |
| 24 | S&F in repairs, mild steel chromium plated towel rail, \"D\" shaped, 20mm dia, 600mm long, premium quality complete all as directed. |
| 25 | S&F in repairs, glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing, 60cm long, complete all as specified and directed. |
| 26 | S&F in repairs, 32mm dia PVC waste pipe with fittings for fixing to WHB and kitchen sinks of suitable length as per site requirement and including taking down old waste pipe complete all as specified and directed. |
| 27 | S&F in repairs, 32mm dia brass chromium plated waste coupling fittings for wash hand basin etc., with long screwed shanks and fly-nuts, flange end bedded in red lead cement and other end fixed complete all as specified and as directed. |
| 28 | S&F in repairs, 15mm bore steel water tubing, medium grade, ISI marked, galvanized, including all fittings such as bends, tees, elbows, reducers, unions, plugs, sockets etc., laid in trenches or fixed to walls and ceilings or concealed in walls and making good, ducts/ceilings or laid in floors complete all as specified and directed. |
| 29 | All as per item No 28 above but 20mm bore of pipe. |
| 30 | S&F in repairs, 15mm bore bib taps, long body, fancy type, chromium plated, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron/GI pipe or for brass ferrule complete all as specified and directed. |
| 31 | S&F in repairs, 15mm bore Pillar taps, cast copper alloy, fancy type with capstan heads, chromium plated, screwed down high pressure, with or without lettered \"Hot\" or \"Cold\" with long screwed shanks and fly-nuts, screwed for iron/GI pipe and fixed complete all as specified and directed. |
| 32 | S&F in repairs, 15mm bore Stop valve, cast copper alloy, chromium plated, fancy type, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron/GI pipe or for union complete all as specified and directed. |
| 33 | S&F in repairs, 125mm size chromium plated shower rose with or without swivel joint complete all as specified and directed. |
| 34 | S&F in repairs, chromium plated Hand Shower (Health Faucet) with 8mm Dia 1.2meter long flexible tube and wall hook complete all as specified and directed.Make: Jaquar CAT No 573 or techno commercially equivalent in Hindware or Parryware/Cera |
| 35 | Demolition of brickwork or stone masonry including all quoins, arches, pillars, etc., built in cement mortar including disposal of debris off the premises complete all as directed. |
| 36 | M&L, brickwork with sub class \"B\" bricks, straight or curved on plan exceeding 6m mean radius built in cement mortar 1:6 complete all as specified and directed. |
| 37 | S&F in repairs, PVC connections 15mm size with PTMT nuts of length 600mm, complete all as specified and directed. |
| 38 | Demolition of cement concrete in floors takig out sunken fillings ,M&L for Treatment of sunken floor slab comprising of the following specifications and all as specified :-(i) Material & labour for cleaning the sunken/lowered portion of RCC slab surface (including vertical total depth plus skirting height) of floors by wire brush, chisel out any mortar sticking to the surface and brooming completely40 mm thick avg PCC (1:2:4) type B-0 using 12.5mm graded aggregate as in padding concrete to achieve proper slope including cutting holes in bricks or RCC wall for spout and fixing 40mm dia GI pipe spout pipe.(ii) Rendering of uneven surfaces with 6mm thick CM (1:4) mixed with integral water proofing compound as per manufacurer instructios.Fill it with water and check dampness and seepage.(iii)All junctions points of side wall where CI/GI pipes are passing through shall be sealed with epoxy putty.(iv)After drying putty, wash the slab and sides of sunken portion with water and make it clear and clean. |
| 39 | (v) Material & labour for applying two coats of polymer modified cementious water proof coating as per manufacturs instruction to bottom and vertical sides up to finished floor level+100mm height.The thickness of two layer shall be 1mm.When the second layer is still sticky, coarse sand spray shall be carried for the vertical and bottom surface of the sunken portion all as specified and directed. (vi) Plaster the bottom and sides up to bottom of the skirting with minimum 20mm thick CM (1:4) mixed with integral water proofing compoundas per manufacturer\"s specification including rounding of corners and junctions sloping towards spout.Note :- Test the water proofed area (ponding test) by filling water for at least 72 hours and shall be tested for leakage seepage and to the entire satisfaction of GE. |
| 40 | M&L for filling in brick aggregates in sunken flooring complete all as specified and directed. |
| 41 | S&F in repairs, stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tacks, or stainless wire staples complete all as specified and as directed. |
| 42 | S&F in repairs, 150mm size, extruded aluminium anodized handles, fabricated type, complete all as specified and as directed. |
| 43 | S&F in repairs, 200mm long aluminium anodized barrel tower bolts of extruded section complete all as specified and directed. |
| 44 | S&F in repairs, 300mm long aluminium anodized sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy complete all as specified and directed. |
| 45 | S&F in repairs, 100mm size stainless steel butt hinges, medium weight complete all as specified and as directed. |
| 46 | S&F in repairs, 150mm long (overall length of cover plate) floor door stopper of aluminium alloy body and tongue, anodized, with hard drawn steel spring, fixed in floor complete all as specified and directed. |
| 47 | M&L in repairs, 12mm thickVeneered decorative plywood, grade 1 (with BWR resin) with decorative face veneers on both faces; fixed with screws to timber frame work complete all as specified and as directed. |
| 48 | M&L in repairs,19mm thick Veneered decorative plywood, grade 1 (with BWR resin) with decorative face veneers on both faces; fixed with screws to timber frame work complete all as specified and as directed. |
| 49 | S&F in repairs, 19/20mm dia stainless steel ,medium grade curtain rod, complete all as specified and directed. |
| 50 | S&F in repairs, stain less steel curtain rod holders of 20mm holding dia with necessary tightening screw65-75 mm long fixed in position complete all as specified and directed. |
| 51 | S&F in repairs first quality vitreous China wash down water closet pan (pedestal pattern), white, of size not less than 400mm x 400mm x 340mm (excluding fixing bolts, flushing cistern and flush pipe) but including provision of plastic watercloset seat, white , closed pattern with flat bottom, and cover and mild steel chromium plated hinging device complete all as specified and directed. |
| 52 | S&F in repairs, 10 litres, PVC valveless, symphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets complete all as specified and as directed. |
| 53 | M & L for all the visible cracks of external wall over 0.5mm size has to be cleaned properly & the same has to be cut open to \"V\" grove with the help of machine and the same has to be filled with smartcare Hybrid PU sealant complete as per manufacturer recommendations. Brand: Asian/Foxroc/Pedilite Note: The above item shall be executed by Auth manufacturer/auth applicator after taking prior approval from Engineer -in- Charge |
| 54 | Cleaning of roofs/ slabs/ chajjas, rain water pipe, Cutting/derooting of small plants/shrubs etc from the building and removing all dust/ dry leaves/ mud etc., and making good disturbed wall/flooring surface with PCC 1:2:4 type B1, using 20 mm graded stone aggregate or in cement mortar 1:3 as per site requirement including disposal of unserviceable material to a distance not exceeding 50m all as specified and directed by engr-in-charge.Note: Measurement shall be made as Plan area of the roof and portico shall be measured for payment, cleaning of chajja shall be included in the rate of roof area. |
| 55 | M&L Providing, cement concrete type B0 1:2:4(12.5 m graded stone aggregate) in roof kerbs or mud stops, rounded or chamfered on edges, chajja coping in slope all as specified by engineer in charge |
| 56 | M&L Screed bed or bedding layer of mortar 1:4 , 15 mm thick for laying floor finishes or over PCC surfaces finished even and smooth without using extra cement at any height all as specified by engineer in charge |
| 57 | S&F in repairs of CPVC pipes 16 mm dia SDR 11 & Plain CPVC SDR 11 fittings in trenches/wall at any height including cutting and chasing if required upto any heightcomplete all as specified. |
| 58 | S&F in repairs of CPVC pipes 20 mm dia SDR 11 & Plain CPVC SDR 11 fittings in trenches/wall including cutting and chasing if required upto any heightcomplete all as specified. |
| 59 | S&F in repairs of CPVC pipes 25 mm dia SDR 11 & Plain CPVC SDR 11 fittings in trenches/wall including cutting and chasing if required upto any heightcomplete all as specified. Note for item 61,62,63 : Work to be executed in multistory buildings the rates qouted by contractor is included any scafoldings required up to ht 10mtr. |
| 60 | S&F, 110mm dia uPVC(SWR) pipes, ISI marked, single socketed in any length with rubber ring joints fixed to walls with PVC clamps as rain water pipe complete all as specified and as directed. |
| 61 | S&F, 110mm bore PVC(SWR) bends any radius with access door and jointing with solvent cement, complete all as specified and as directed. |
| 62 | S&F, 75mm dia uPVC(SWR) pipes, ISI marked, single socketed in any length with rubber ring joints fixed to walls with PVC clamps as rain water pipe complete all as specified and as directed. |
| 63 | S&F, 75mm bore PVC(SWR) bends any radius with access door and jointing with solvent cement, complete all as specified and as directed. |