| 1 | S&F Fence controlledoperating voltage 12V, 75 Watt peak, Solar DC, Voltage input12V,100AH, DC battery back up each fence controller having energizers including taking down old unserviceable fen controller and its connected items all as specified and directed to achieve the following parameters:-a)Nominal operating voltage shall be between 6000V to 10000V.b) The pulse interval shall be of 1.2 second.c) The pulse duration shall be less than 03 millisecond.Note :-i) Warning and alerts shall be configured for system fault, serious breach and pulse count.ii) LCD display which displays: battery voltage, output voltage each zone, fault/alarm each zone.iii) The makes of the component / parts of solar fencing shall be as per manufacturer\"s requirement and shall be of same company as for as possible except batteries.iv) Battery shall be measured & paid separately Make: Silicon Solar System / Radiant Energy Technologyy |
| 2 | M&L Alarm device operating on 12V having audibility of 125 Db noise level, alarm must turn ON automatically at all the field controller locations when fence is damaged or voltage drop complete all as specified and direced. Make: Silicon Solar System / Radiant Energy Technologyy |
| 3 | S&F in replacement of Intermediate security post 25 mm Square tube x 2mm thick and hot dip galvanised to minimum 70 microns with fixed Insulators clamping riveting (1.3 M height, 10 line configuration) suitable to fix on intermediate post assembly complete all as specified and directed by Engineer- In-Charge.Make: Silicon Solar System / Radiant Energy Technologyy |
| 4 | S&F in replacement of Fixed insulators made of high density polyethylene UV stabilised having a breakdown voltage of not less than 15 KV and having a shield to prevent arcing between wire and post with glossy surface to prevent accumulation of dust and facilitate cleaning, the construction and design of the insulator shall be such that it will facilitate triggering of an alarm in the event of an intruder attempting to climb, intermediate insulators shall have two wire retaining lugs that shears and breaks upon a load of 30 to 40 Kgs complete all as specified and directed. Make: Silicon Solar System / Radiant Energy Technologyy |
| 5 | S&F in replacement of End post assembly 1.3 M design comprising of (a) Main post: 1.3 metre high (1.0+0.3 M for grouting) 40mm Square tube mild steel pipe ISI marked 3mm thick with 70 micron hot dip galvanising, (b) Support post: 1.3 M long, 25mm Square mild steel pipe ISI marked 2mm thick with 70 micron hot dip galvanising,with suitable fixing mechanism complete all as specified and directed by Engineer- In-Charge. Make: Silicon Solar System / Radiant Energy Technologyy |
| 6 | S&F in replacement of Fixed insulators Clamps with 70 microns with steel riveted complete all as specified and directed. Make: Silicon Solar System / Radiant Energy Technologyy |
| 7 | S&F in replacement of End strain hooks hot dip galvanised upto 30 microns facilitate fixing strain insulators and tensoners complete all as specified and directed. Make: Silicon Solar System / Radiant Energy Technologyy |
| 8 | S&F in replacement of End strain insulators of high impact, high strength UV polycarbonate material virgin grade capable of withstanding upto 15 KV and shall not allow power leakage complete all as specified and directed. Make: Silicon Solar System / Radiant Energy Technologyy |
| 9 | S&F in replacement of Joint clamps of Zinc Plating with silver passivation MS material, fastener shall facilitate firm connection of fence strand size upto 4mm complete all as specified and directed. Make: Silicon Solar System / Radiant Energy Technologyy |
| 10 | S&F in replacement of Concealed fence configuration link bus bars made of 12SWG HT wirebus bar connectivity achieved by metal GI completely to offer highest security, link bus bars used for configuring/looping the power fence at end posts and corner posts complete all as specified and directed. Make: Silicon Solar System / Radiant Energy Technologyy |
| 11 | S&F in replacement of Wire Tighteners made of GI with Aluminium runner to facilitate tensioning of fence strands in both directions and shall have firm locking mechanism complete all as specified and directed. Make: Silicon Solar System / Radiant Energy Technologyy |
| 12 | Fixing only High tensile wire of 2.59mm dia with zinc coating of 280 GSM, corrosion resistant, having UTS of 140 Kg/sq.m, as per IS 398 complete all as specified and directed.Note : Wire shall be issued under Schedule \"B\" free for fixing. |
| 13 | S&F HV double insulated cable made of two layer insulation, outer insulation of abrasion resistant HDPE and inner insulation of polypropylene, core shall be of 2.5mm galvanised steel, the diameter with inner insulation shall be 4.1mm and the diameter of the cable with both insulation shall be 7.6mm for inter connection between the fence controller and power fence complete all as specified and directed. Make:- Arrow Cable/Unicab/Finecab |
| 14 | M&L for PCC (1:3:6) type C-1 using 20mm stone aggregate in foundation of fencing poles including necessary formwork fair finished and finishing the exposed surfaces even and smooth without using extra cement complete all as specified and directed. |
| 15 | Removing, Re-Installation and commissioning tightening of the loose solar power fence (10 Lines Fence) complete all as specified and directed. Note :01 span equal to distance between two poles |
| 16 | Trimming of trees along the solar fence on the basis of daily wages for one person per day complete all as specified and directed by Engineer- In-Charge. |
| 17 | S&F in replacement of 20/25 mm dia Rigid non-metallic PVC conduit exclusive of boxes (junction/ terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts,saddles, pipe hooks etc complete all as specified and directed by Engineer- In-Charge.Make : Finolex/Precision/Sudhakar |
| 18 | Taking Up/down super earth kitwith all accessories complete all as specified and directed by Engr in Charge |
| 19 | M&L for Super earth kit comprising of non rusting 304 grade stainless steel rod of 10mm dia inserted in moisture absorbent chemical mixture , earth kit weighing minimum 4kg, 4feet long, fasteningassembly shall be of hot dip galvanised and made of stainless steel complete all as specified and as directed. |
| 20 | M&L in repair solar module mounting arrangement pole with mounting structure with hardware 35x35x3mm thick angular iron \"H\" frame , 2\"dia 8 feet long pole and angle adjustment mechanism 2 core cablefor solar module to fence system complete all as specifiedand directed |
| 21 | M&L for Power supply unit for DC power supply 12 / 18 Volt DC 3 Amps complete all as specified and directedMake: Silicon Solar System / Radiant Energy Technologyy |
| 22 | Suply in replacement of Battery 12Volt, 100AHmaintenance free battery complete all as specified and directed.Make : Exide/ Luminous/ Amaron |
| 23 | Supply and replacement of outdoor console rack made of 3.15mm thick CRCA sheet suitable for extensive outdoor application compling with IP55 standard for housing fence controller, battery, automatic voltage regulator, power supply board etc with suitable power supply distribution ON OFF control switchess and internalwiring with suitable lock and key arrangement and including suitable mild steel angle iron frame including suitable PCC work complete all as specified and directed. |
| 24 | M&L for LED Live light capable of flashing a thin visible momentary light with each pulse emitted by the controller complete all as specified and directed.Make : Silicon solar systems (SSS) /Radiant Energy Technology. |
| 25 | M&L for Lightening diverter capable of diverting stray lightening from fence to earth complete all as specified and directed.Note: Lightning diverter shall have the provision for adjusting the spark gap.Make : Silicon solar systems (SSS) /Radiant Energy Technology. |
| 26 | Supply and fixing of LED Driver of similar wattage with operating voltage inputac 85- 300 volt , pf> .95 asper IS 15885 with inbuilt surge protectionof minimum 5 kvand BIS certifiedsuitable for45 watts LED street light fittings of any makecomplete all as specified and directed. |
| 27 | Supply and fixing of LED Driver of similar wattage with operating voltage inputac 85- 300 volt , pf> .95 asper IS 15885 with inbuilt surge protectionof minimum 5 kvand BIS certifiedsuitable for70/72 watts LED street light fittings of any makecomplete all as specified and directed. |
| 28 | Supply and fixing of LED Driver of similar wattage with operating voltage inputac 85- 300 volt , pf> .95 asper IS 15885 with inbuilt surge protectionof minimum 5 kvand BIS certifiedsuitable for90 watts LED street light fittings of any makecomplete all as specified and directed. |
| 29 | Supply and fixing of LED Driver of similar wattage with operating voltage inputac 85- 300 volt , pf> .95 asper IS 15885 with inbuilt surge protectionof minimum 5 kvand BIS certifiedsuitable for150 watts LED floodlight fittings of any makecomplete all as specified and directed. |
| 30 | Supply and fixing of LED Driver of similar wattage with operating voltage inputac 85- 300 volt , pf> .95 asper IS 15885 with inbuilt surge protectionof minimum 5 kvand BIS certifiedsuitable for200 watts LED floodlight fittings of any makecomplete all as specified and directed. |
| 31 | Supply and fixing of surge protection of 10 KV suitable upto 100W LED light fittings suitable to operate on input voltage 440 AC,50 Hz,complete all as specified and directed. |
| 32 | Supply and fixing in replacement of LED street light fitting 40 Watt230 V AC outdoor type with high pressure diecast aluminum hosing and heat resistantcomplete with driver, lamp bracket with impact and corrosion resistant including thermalmanagement in multiple optics complete withIP 65/66 protection complete Make : Havells/Bajaj/Crompton/Philips |
| 33 | All asItem No 32 above but 60 Watts |
| 34 | All as Item No. 32 above but 70 Watts |
| 35 | Supply and fixing Solar Street Light30 W , High Efficiency, Mono Crystalline Solar PV Module, Lithium Ferro Phosphate battery with in-built BMS technology, High Efficacy LED, MPPT Solar Charge Controller Including pole and light suitable pole upto 9 Meter inlcude pole fittings and fixing base with all connected parts and Aluminium Extruded body & is specially programmed to automatically control the dimming and brightness of light,which increse the backup time all as specified and directed by engr in charge Make :- Havells/Philips/Wipro |
| 36 | Material and labour for replacement of unserviceable street light bracket made out of GI pipe 1.2 mtr long 32 to 50mm dia suitable for street light fitting, light grade bent to shape as directed including nut, bolts, washer and MS flat iron clamp of required size for fixing bracket suitable for PCC/ steel tubular poles all as directed incl taking down of old unsv bracket. |
| 37 | Supply and laying of cable XLPE insulated, armoured heavy duty electric cable, galvanised steel strip or wire armoured, with aluminium conductor electric power cable(heavy duty) 1100 volts grade with stranded aluminium conductor of size(a) 35 sqmm x 3.5 core Note :- (a)The cost of Al thimbles/lugs and cable gland etc is includedin quoted rate and no extra payment will be made for it.(b) Excavation, earth work, sand cushioning and brick protection will be measured and paid separately under respective items. |
| 38 | All as ItemNo37above but 16 sqm 4.0 core. |
| 39 | S&F in replacement of PVC insulated multi core round stranded copper conductor (Flexible) 3 core of size 1.5 sqmm 1100 volts grade heavy duty including all accessories complete |
| 40 | Supply & fixing in replacement of automatic street light switch using Nature Switch for automatic switching of street lights based on LUX level of natural light the sensor (nature switch) along with suitable power contactors and MCBs (Input-output) should be enclosed in pole/wall mountable enclosure made of rust proof, Electric shock proof, termite proof and FR grade SMC junction box (sintex make) conforming to IP 54.the contactor,MCBs and copper circuit wiring (min.10sqmm) should enough to take: three-phase load of 12-15KW;contactor Rating 32Amps; MCB(spn) Rating 32Amps. Healer Enterprises Model no SWADEEP-02EC12KW3P or equivalent in Seimens and Havells. |
| 41 | Supply & fixing in replacement of automatic street light switch using Nature Switch for automatic switching of street lights based on LUX level of natural light the sensor (nature switch) along with suitable power contactors and MCBs (Input-output) should be enclosed in pole/wall mountable enclosure made of rust proof, Electric shock proof, termite proof and FR grade SMC junction box (sintex make) conforming to IP 54.the contactor,MCBs and copper circuit wiring (min.6sqmm) should enough to take: three-phase load of 8-11KW;contactor Rating 20Amps; MCB(spn) Rating 20Amps. Healer Enterprises Model no SWADEEP-02EC8KW3P or equivalent in Seimens and Havells. |
| 42 | Excavation in trenches not exceeding 1.5M wide and exceeding 1.5M in depth and getting out in hard/dense soil for laying of under ground cable all as directed. |
| 43 | Returning filling in including spreading, leveling watering and well ramming in layer not exceeding 25 Cms. |
| 44 | Removal of excavated surplus soil not exceeding 50 m and depositing where directed at al level not exceeding 1.5 m above the starting point. |
| 45 | Supply and spreadingsand in trenches as cushioning to under ground cable on top and bottom of cable all as specified. |
| 46 | Supplying and laying dry bricks in trenches over under ground electric cable for mechanical protection with width equal to length of bricks with well burnt sub class ‘B’ old size bricks ISI Markedlaid flat complete. |
| 47 | S&Fin replacement of GI pipe light grade 40mm bore for cable protection complete all as specified and directed. |
| 48 | Supply and fix in replacement of MCB SP 6 to 32 Amp 10 KA C Curve |
| 49 | Supply and fix in replacement of MCB TPN 32 Amp 10 KA C Curve |
| 50 | Supply and fix in replacement of MCB TPN 40 to 63 Amp 10 KA C Curve |
| 51 | Dismantling & taking down old U/S earthing & M&L for earthing complete with galvanised steel earth plate 600 mm x 600 mm x6.3 mm thick elecrode and 4 mm dia galvanised iron wire as earthing lead burried directly in ground vertically (earth pit not less than 2.25mtr deep below ground level) with top edge of the plate not less than 1.5mtr below normal ground level, the earth plate surrounded by adequate quantity of charcoal dust of minmum qty - 40 Kg and common salt of minmum qty - 40 Kg to a packed thickness of 15 cm on all sides of electrode as specified and connected to GI wire of dia 4 mm as earth lead by means of bolts, nuts, check nuts and washers (including welding) of galvanised iron or steel and connected to main switch board / panel/ test point at the other including necessary earth work in any type of soil, returning filling in and removal of surplus soil, concrete pit in PCC (1:3:6) type C1, precast RCC 1:2:4 type B1 cover slab 54cm x 54cm x 5cm reinforced with 8mm dia bar TMT @150mm centre to centre both ways with one handle for lifting made out 8mm dia MS bar with wire mesh funnel, 20mm GI tubing medium grade for watering and 20mm GI tubing medium grade for protection, test point, testing on completion all as shown in Electrical Plate No 3 of SSR Part-I complete all as specified and directed. |
| 52 | Dismantling & taking down old U/S earthing &M&L for earthing complete with galvanised steel earth plate 600 mm x 600 mm x 6.3 mm thick elecrode and 25 mm x 4 mm galvanised iron strip as earthing lead burried directly in ground vertically (earth pit not less than 2.25mtr deep below ground level) with top edge of the plate not less than 1.5mtr below normal ground level, the earth plate surrounded by adequate quantity of charcoal dust of minmum qty - 40 Kg and common salt of minmum qty - 40 Kg to a packed thickness of 150 mm on all sides of electrode as specified and connected to GI strip 32 mm x 6 mm as earth lead by means of bolts, nuts, check nuts and washers (including welding) of galvanised iron or steel and connected to main switch board / LT panel/ test point/equipment at the other including necessary excavation of earth work in any type of soil, returning filling in and removal of surplus soil, concrete pit in PCC (1:3:6) type C1, pre cast RCC 1:2:4 type B1 cover slab 54 cm x 54 cm x 5 cm reinforced with 8mm dia bar TMT @150mm centre to centre both ways with one handle for lifting made out 8mm dia MS bar with wire mesh funnel, 20 mm bore GI tubing medium grade for watering and 40 mm GI tubing medium grade for protection, test point, testing on completion all as shown in Electrical Plate No 3 of SSR Part-I complete all as specified and directed. |
| 53 | Dismantling & taking down old U/S earthing &M&L for earthing complete with galvanised steel earth plate 600 mm x 600 mm x 6.3 mm thick elecrode and 32 mm x 6 mm galvanised iron strip as earthing lead burried directly in ground vertically (earth pit not less than 2.25mtr deep below ground level) with top edge of the plate not less than 1.5mtr below normal ground level, the earth plate surrounded by adequate quantity of charcoal dust of minmum qty - 40 Kg and common salt of minmum qty - 40 Kg to a packed thickness of 150 mm on all sides of electrode as specified and connected to GI strip 32 mm x 6 mm as earth lead by means of bolts, nuts, check nuts and washers (including welding) of galvanised iron or steel and connected to main switch board / LT panel/ test point/equipment at the other including necessary excavation of earth work in any type of soil, returning filling in and removal of surplus soil, concrete pit in PCC (1:3:6) type C1, pre cast RCC 1:2:4 type B1 cover slab 54 cm x 54 cm x 5 cm reinforced with 8mm dia bar TMT @150mm centre to centre both ways with one handle for lifting made out 8mm dia MS bar with wire mesh funnel, 20 mm bore GI tubing medium grade for watering and 40 mm GI tubing medium grade for protection, test point, testing on completion all as shown in Electrical Plate No 3 of SSR Part-I complete all as specified and directed. |
| 54 | Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 6 sq.mm 2 core nominal cross section in service connections complete all as specified and directed |
| 55 | All asper Item No. 54 above but 10 sq.mm 2 core |