Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Demolition of cement concrete (unreinforced) in ground floor and pavingn.exc 15 cm thick above or below ground level complete and disposal of unserviceable material, debris and rubbish to a distance not exceeding 100m complete all as specified and directed. |
| 2 | Demolition of cement concrete (reinforced) as in roofs, floors (other than ground floors), beams, staircases, landing, chajjas and similar suspended work complete(reinforcement cut as required to facilitate demolition) and disposal of unserviceable material, debris and rubbish to a distance not exceeding 100m complete all as specified and directed. |
| 3 | Demolition of reinforced cementconcrete of any description and in any position not otherwise specifically provided for complete (reinforcement cut as required to facilitate demolition) and disposal of unserviceable material, debris and rubbish to a distance not exceeding 100m complete all as specified and directed. |
| 4 | Demolition of brick workor stonework or precast concrete articles and precast concrete block walling ,built in cement mortar including allquoins, arches pillars etc but excluding ashlar facings ,dressed stonework and precast concrete articles and stacking the serviceable materials within 100m and disposal of unserviceable material, debris and rubbish to a distance not exceeding 100m complete all as specified and directed. |
| 5 | Demolition and breaking up drain pipes (Salt glazed ware, AC or Reinforced concrete) of internal dia 150mm set in cement mortar complete all as specified and directed. |
| 6 | Dismantling of cast iron or reinforced concrete drain pipes of 100mm internal dia, jointed in cement mortar and taking out of trenches, if required complete all as specified and directed. |
| 7 | Dismantling water tanks of capacity exceeding 250 ltr and not exceddding 500 ltr complete all as specified and directed. |
| 8 | Taking down chowkhats with shutters (without taking off shutters from the frame) exceeding 1.50 sqm but not exceeding 4.00 sqm each complete all as specified and directed. |
| 9 | Taking down chowkhats or frame not exceeding 1.50 sqm each complete all as specified and directed. |
| 10 | Taking down cement plaster of any description on bricks, PCC block or stone walls etc including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed. |
| 11 | Separating, scraping and cleaning of reinforcement (Demolition of concretemeasured separately) complete all as specified and directed. |
| 12 | Removing demolished building materials etc to a distance exceeding 1 Km but not exceeding 5KM beyond the lead already included in the respective items including loading, unloading and stacking at the destination complete all as specified and directed. |
| 13 | Surface excavation not exceeding 30cm deep and averaging 15 cm deep and getting out in any type of soil and disposal of surplus excavated soil, within a lead of 50m, complete all as specified and directed. |
| 14 | Earth work in excavation by mechanical means Hydraulic excavator)/ in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5m, including getting out in all kind of soil (the excavated soil) anddisposal of surplus excavated soil, within a lead of 50m complete all as specified and directed. |
| 15 | Earth work in excavation by mechanical means (Hydraulic excavator) means over areas (exceeding 30cm in depth but not exceeding 1.5m in depth, exceeding 1.5m in width as well as 10 sqm on plan) including getting out in all kind of soil and disposal of excavated earth lead upto 50m and lift upto 1.5m, as directed. |
| 16 | Earth work in excavation by mechanical means (Hydraulic excavator) means over areas exceeding 1.5m in depth but not exceeding 3.0m in depth, exceeding 1.5m in width as well as 10 sqm on plan) including getting out in all kind of soil and disposal of excavated earth lead upto 50m and lift upto 3.0m, as directed. |
| 17 | Earth work in excavation by mechanical means (Hydraulic excavator) means over areas (exceeding 3m in depth but not exceeding 4.5m in depth, exceeding 1.5m in width as well as 10 sqm on plan) including getting out in all kind of soil and disposal of excavated earth lead upto 50m and lift upto 4.5m, as directed. |
| 18 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25Cm, complete all as specified and directed. |
| 19 | Forming embankments including raising (or lowering) earth, spreading in layers n exc 30 cm thick; watering, ramming/ rolling and finishing to required size, shape, etc, n exc 1.5 m high from basecomplete all as specified and directed. |
| 20 | Removing excavated materials/ soils, exceeding 250mtrs not exceeding 500mtrs and depositing where directed at a level not exceeding 1.50mtrs, complete all as specified and directed. |
| 21 | Removing excavated materials/ soils, exceeding 500mtrs but not exceeding 1.5Km and depositing where directed at a level not exceeding 1.50mtrs, complete all as specified and directed. |
| 22 | Hard core of broken stone or boulders of gauge not exc 63 mm deposited, spread and leveled in layer not exc 15 cm thick complete all as specified and directed. |
| 23 | Hand packing(any thickness) of broken stone or boulders at back of walls over arches etc. and raising (or lowering) to the required level complete all as specified and directed. |
| 24 | Treating the backfill in contact with sides of columns below ground level @ 7.5 litres of emulsion /Sqm of vertical surface complete all as specified and directed. |
| 25 | Treating the backfill in contact with wall @ 7.5 litres of emulsion /Sqm of vertical surface complete all as specified and directed. |
| 26 | Treating the bottom & sides of excavation, under sub base and plinth protection @ 5 litres of emulsion/Sqm of surface areacomplete all as specified and directed. |
| 27 | Treating the soil along with external perimeter of building @ 2.25 litre of emulsion/metre of the perimeter wallcomplete all as specified and directed. |
| 28 | 50mm dia high density polyethylean pipe (HDPE) and pressure rating 6kgf/cm2 as weep hole (retaining walls) ( complete all as specified. |
| 29 | PCC 1:5:10 (nominal mix) type E-2(using 40mm graded crushed stone aggregates) as in foundation filling and mass concretecomplete all as specified and directed. |
| 30 | PCC 1:4:8 (nominal mix) type D-2(using 40mm graded crushed stone aggregates) as in foundation filling and mass concretecomplete all as specified and directed. |
| 31 | PCC 1:3:6 (nominal mix) type C-2(using 40mm graded crushed stone aggregates) as in foundation filling and mass concretecomplete all as specified and directed. |
| 32 | PCC 1:2:4 (nominal mix) type B-2(using 40mm graded crushed stone aggregates) as in foundation filling and mass concretecomplete all as specified and directed. |
| 33 | PCC 1:4:8 (nominal mix) type B-2(using 40mm graded crushed stone aggregates) as in drains and surface channels finished even and fair complete all as specified and directed. |
| 34 | Extra for formingfair finished drain or channel n.exc 30 cm inner girth in cement concrete using extra cement including forms, moulds mitred / stopped ends etc complete all as specified and directed. |
| 35 | Providing precast cement concrete type B1 1:2:4 (using 20mm graded crushed stone aggregate) as in landings, cover slabs (for man holes, drain etc.)chullah hoods,chajjas, water troughs, mangers, shelves and similar articlesand set in cement mortar 1:4 all as specified. |
| 36 | Providing cement concrete 1:2:4 type B-1 (using 20mm graded crushed stone aggregate) in roof kerbs or mud stops rounded or chamfered on edges in lintels upto 1.50m clear span cills steps seismic and other similar nads plinth courses, string courses, lacing courses, parapets and railing upto 60cm in height , coping , kneelers, apex stones bed plates,water troughs and the like including weathering slightly rounded or chamfered angles and throating as directed complete including necessary formwork where required complete all as specified. |
| 37 | RCC (M-25 design mix)(using 20mm graded crushed stone aggregate) as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all specified. |
| 38 | RCC (M-25 design mix)(using 20mm graded crushed stone aggregate) as inwalls, retaining walls, basement walls, ballast walls and the like; anythickness; above top of footings; including attached pilasters and buttresses complete all specified. |
| 39 | RCC (M-35 design mix)(using 20mm graded crushed stone aggregate) as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all specified. |
| 40 | RCC M-35 (Designmix) (using 20 mm graded crushed stoneaggregates) as in columns, pillars, piers, posts and struts complete all as specified and directed. |
| 41 | RCC M-35 (Designmix) (using 20 mm graded crushed stoneaggregates) as in beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and directed. |
| 42 | RCC M-35 (Designmix) (using 20 mm graded crushed stoneaggregates) as inwalls, retaining walls, basement walls, ballast walls and the like; anythickness; above top of footings; including attached pilasters and buttresses complete all as specified and directed. |
| 43 | RCC M-35 (Designmix) (using 20 mm graded crushed stoneaggregates) as inslabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed. |
| 44 | Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter etc for rough finished surfaces of concrete flat all as specified |
| 45 | Formwork to sides and soffits of floor or roof beams, beam haunching, girders, bressumers, lintels, cantilevers, shelves including supports overhangs etc also splays between floors and beams etc for fair finished surfaces of concrete flat complete all as specified. |
| 46 | Formwork to sides and soffits of floor or roof beams, beam haunching, girders, bressumers, lintels, cantilevers, shelves including supports overhangs etc also splays between floors and beams etc for rough finished surfaces of concrete flat complete all as specified. |
| 47 | Formwork to square, rectangular or polygonal sides of pillars, posts, struts, piers, columns and stanchions for fair finished surfaces of concrete complete all as specified. |
| 48 | Formwork to faces of walls, retaining walls, abutments, parapets and staircase railings and similar work including attached pillasters, buttresses etc: vertical or to batter; fair finished surfaces of concrete flat all as specified. |
| 49 | Form work to soffits of suspended slabs such as roof slabs, floor slabs landings and similar work, not exceeding 200mm thick (horizontal or sloping) for fair finished surfaces of concrete flat, complete all as specified & directed. |
| 50 | Form work to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20cm wide and sides of RCC/ PCC bands in walls, horizontalor sloping and similar work exc 10cm but n exc 20cm wide for fair finished surfaces of concrete, complete all as specified & directed. |
| 51 | Brick work with sub class \"B\" bricks old size straight or curved on plan exc 6m mean radius built in cement mortar 1:4 complete all as specified. |
| 52 | Brick work with sub class \"B\" bricks old size straight or curved on plan exc 6m mean radius built in cement mortar 1:6 complete all as specified. |
| 53 | Brick work with fly ashbricks (modular bricks), straight or curved on plan exc 6m mean radius, built in cement mortar 1:4for cable ducts complete all as specified. |
| 54 | Factory made solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain coloured PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing on page No180 of MES SSR 2020 Part-II complete all as specified and directed. |
| 55 | Pressed steel frame using 1.25 mm thick PBI sheet (size of frame 125 x 60 mm) for doors with one or more rebates including necessary fixing lugs, hinges, lock/ strike plate etc and filling with PCC 1:2:4 type B-0 (using 12.5mm graded crushed stone aggregates) as in back of chowkatscomplete all as specified. |
| 56 | 35mm thicksecond class hardwood (Sal/Hollock) factory made plain framed panelled shutter (two panel) with lock rails & panel of 9 mm B.W.P commercial ply wood or 12 mm thick veneered particle board with commercial veneering on both side. The size of rail and stile as per IS:1003(Part-I) kiln seasoned andchemically pressure treated complete all as specified and directed. |
| 57 | 35 mm thick2nd class hard wood (Sal/Hollock)) glazed & skeleton factory made shutters, open rebated and prepared to receive glass, gauze etc (without sash bars), edges of framing plain, chamfered or rounded fitted with cut and mitered beads for securing glass, etc, sizes of members ofdoor shutters as specified in SSR- 2009Part-I Section 8.24(a) complete all as specified and directed. |
| 58 | Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of 5 mm thick plain coloured PVC sheet to be fitted in the M.S. frame welded/ sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site, drawing on page No176 of MES SSR 2020 Part-II complete all as specified and directed. |
| 59 | Factory made steel window box type using ERW hollow \"P\" section comprising double frame for and including gauged and glazed skeleton shutter, jointed internally with flat iron 40x4mm complete including grill of 8mm square bars, fixed horizontally @ 10cm c/c, hinges, handle, tower bolts, stops, lugs etc complete all as shown on drawing No. CEUZ/TD/1302/09 sheet 1/3 to 3/3 amended upto 02/06/12 andincluding necessary iron mongery, glazing, wire gaugecomplete all as specified and directed. |
| 60 | 250mm longaluminium alloy, anodized, sliding door bolt with hasp, staple(bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded section or cast aluminium alloy complete all as specified and directed. |
| 61 | Aluminium handles cast type anodizedof size 150 mm complete all as specified and directed. |
| 62 | Aluminium anodizedbarrel tower bolt of extruded section of size 200mm and fixed complete all as specified and directed. |
| 63 | Mild Steel 300mm, ordinary rat tail rod patttern springs including roller & roller plate all as specified. |
| 64 | Floor door stopper of 140mm long of alluminium alloy body and tongue, anodized with hard drawn steel spring, fixed in floor complete all as specified and directed. |
| 65 | Mild steel butt hinges of size 100 mm heavy weight cold rolledcomplete all as specified and directed. |
| 66 | Butt hinge of size 100mm, extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed, type B-21 complete all as specified and directed. |
| 67 | Cast iorn ward rope hooks / Peg set of three (50mm to 60 mm) complete all as specified and directed. |
| 68 | Galvanished mild steel wire cloth 0.56mm nominal dia of wire and average width of aperture 1.18 mm and fixed with tinned tacks or galvanished wire staples complete all as specified and directed. |
| 69 | Sheet glass 3 mm thick ordinary quality and glazing with oil putty in squares n.exc 0.5 sqm each pane complete all as specified and directed. |
| 70 | 3mm thick, figured glasspin head type and glazing with oil putty in squares n.exc 0.5 sqm each pane complete all as specified and directed. |
| 71 | Mild steel framed work such as grills,gratings,manhole cover frames etc. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 all as specified and directed. |
| 72 | TMT steel bars 6 to 8mm dia as in reinforcement for concrete, cut to length, bent to shape requuired, including cranking, bending spirally for hooping for columns, hooping endand binding with MS wire (annealed) not less than 0.9 mm dia, complete all as specified |
| 73 | TMT steel bars 10mm dia and over as in reinforcement for concrete, cut to length, bent to shape requuired, including cranking, bending spirally for hooping for columns, hooping endand binding with MS wire (annealed) not less than 0.9 mm dia, complete all as specified |
| 74 | All as per Srl item No 73 above but5mm dia and over upto and including 10mm in stirrups, spacers and binders complete all as specified |
| 75 | Plain cement concrete 1:3:6 type C-1 (using 20 mm graded crushed stone aggregates), 50mmthick as in plinth protection etc., surface finished even and fair without using extra cement all as specified. |
| 76 | Non-skid Ceramic tiles (coloured) 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match and including 15mm thick bedding layer in cement mortar (1:4)complete all as specified and directed. |
| 77 | Glazed ceramic colouredtilesof size300mm x 200mm x7 mm thick as in vertical surfaces , set and jointed in neat cement slurry and pointed with white or coloured cement to match the shade of tile over and including 10 mm thick cement plaster in cement mortar 1:4 complete all as specified and directed. |
| 78 | Machine cut kota stone slab flooring 20-25 mm thick of size not less than 550 mm X 550 mm, laid and jointed with grey cement slurry mixed with pigment to match the shade of slab, as in floor etc, laid over and including 15mm screed layer in cement mortar 1:4,; cutting, rubbing, grinding and polishing to achieve mirror finish complete, all as specified. |
| 79 | Machine cut kota stone slab flooring 20-25 mm thick, laid and jointed with grey cement slurry mixed with pigment to match the shade of slab, as in riser of steps, skirting, dado and pillar, laid over and including 15mm thick cement plaster in cement mortar 1:4,; cutting, rubbing, grinding and polishing to achieve mirror finish complete, all as specified. |
| 80 | Rendering cement plaster 15mm thick in cement mortar 1:4 on fair faces of brick wall or on concrete surfaces, mixed with water proofing compound as per manufacturer\"s instructions, trowelled to even and smooth finish without using extra cement complete all as specified. (Note:- WPCwill be measured and paid separately) |
| 81 | Rendering cement plaster 20mm thick in cement mortar 1:3 on fair faces of brick wall or on concrete surfaces, surface finished even and smooth without using extra cement, all as specified. |
| 82 | Rendering cement plaster 10mm thick in cement mortar 1:4 on fair faces of brick wall or on concrete surfaces, surface finished even and smooth without using extra cement, all as specified. |
| 83 | Rendering cement plaster 10mm thick in cement mortar 1:6 on fair faces of brick wall or on concrete surfaces, surface finished even and smooth without using extra cement, all as specified. |
| 84 | Rendering cement plaster 15mm thick in cement mortar 1:4 on fair faces of brick wall or on concrete surfaces, surface finished even and smooth without using extra cement, all as specified. |
| 85 | Rendering cement plaster 15mm thick in cement mortar 1:6 on other than fair faces of brick wall or on concrete surfaces, surface finished even and smooth without using extra cement, all as specified. |
| 86 | 5 mm thick rendering in cement mortar 1:3 onconcrete surfaces as in ceiling surface finished even & smooth without using extra cement complete all as specified and directed . |
| 87 | Supplying only Integral waterproofing compound |
| 88 | Flush pointing to brick walls in cement mortar 1:3, complete all as specified. |
| 89 | Rendering 15 mm thick onother than fair faces of brick work or concrete surfaces in CM (1:3) on roof surface, finished even and smooth without using extra cement complete all as specified and directed. |
| 90 | Applying evenly a tack coat of industrial bitumen 85/25 at the rate of 1.2 kg per sq. m including cleaning surfaces of roof complete all as specified and directed. |
| 91 | APP membrane minimum weighing 3 kg /sqm and minimum 3 mm thick reinforced with polyester non wove fabric( wt not less than 150 gm/sqm) land on primed surface by forced application compete all as per manufacture instruction and as directed. |
| 92 | Wire brusing & cleaning top surface of cement concrete, including flashings & junction of parapets, etc., & surface painting, with a layer of blown bitumen of any penetration applied hot @ 1.7 kg per sq. m. blinded with grit or pea size gravel @ 0.006 cu. m per sq. m, & lightly tampered (area of flashings, etc., shall be added to the roof area) complete all as specified and directed. |
| 93 | Preparation ofroof surface and applying two coats of aluminium paint over a coat of primer complete all as specified and directed. |
| 94 | Preparation of wooden surfaces of any descriptionand applying two coats of synthetic enamel paintover a coat of pinkprimer complete all as specified and directed. |
| 95 | Preparation of steel surfaces of any description, over 10cm in width or girth,not otherwise describedand applying two coats of synthetic enamel paint over a coat of red oxide primercomplete all as specified and directed. |
| 96 | Preparation of steel hidden surfaces of any description and applying two coats of red oxide primercomplete all as specified and directed. |
| 97 | Preparation of new plastered or unplastered surfaces of walls and applying two coats of oil bound distemper over a coat of primer complete all as specified and directed. |
| 98 | Preparation of new plastered or unplastered surfaces of walls and applying two coats of oil bound distemper over a coat of 2mm wall care putty complete all as specified and directed. |
| 99 | Preparation ofplastered or unplastered surface of ceiling and applying three coats of white wash complete all as specified and directed. |
| 100 | Preparation ofplastered or unplastered surface of walls and applying three coats of white wash complete all as specified and directed. |
| 101 | Preparation ofplastered or unplastered surface of walls and applying two coats of cement base paint over a coat of alkali resistant priming paint complete all as specified and directed. |
| 102 | Fixing only Armoured Plates/Sifcon Pannels complete all as specified and directed.Note:- Armoured plates/Sifcon pannel issued under Sch \"B\" Free for fixing. |
| 103 | G I tubingmedium gradeof 15 mm borewith all fittings and fixtures fixed to wall and ceiling or laid infloor/trenches complete all as specified and directed. |
| 104 | G I tubingmedium gradeof 20 mm borewith all fittings and fixtures fixed to wall and ceiling or laid infloor /trenches complete all as specified and directed. |
| 105 | Wash basins, Vitreous China (Flat white type) size 630mmx450mm, crystal white with and including cutting for and pinning on ends of brackets, 450 mm long PVC connections 15mm size with PTMT coupling nuts at both ends, trap, grating and Union for discharge pipe, waste, chain and plug and porcelain stopper, waste pipe of polythylene of low or high density or PVC of 32mm dia including 32mm dia waste fittings, brass chromium plated with long screwed shanks and fly nuts, flange and bedded in red lead cement and other end fixed, screwed for iron pipe and fixed, completeall as specified. |
| 106 | Pillar taps cast copper alloy with capstan heads chromium plated screwed down high pressurewith or without lettered \"Hot\" or \"Cold\" with long screwed shanks and flynuts, screwed for iron pipe of bore 15 mm complete all as specified and directed |
| 107 | Stop valves/ angle valve/ concealed valve, cast copper alloy, chromium plated, fancy type, screwed down,high pressure ,screwed both ends for 15mm bore iron pipe or for unions and fixedcomplete, all as specified. Type of valve approved by the GE. |
| 108 | Bib tap, cast copper alloy ,chromium plated, fancy type , screwed for iron pipe or for brass ferrule of 15 mm bore complete all as specified and directed. |
| 109 | Gun metal globe orgate valve with iron wheel head, screwed both ends for iron pipe and fixedbore dia of pipe 20 mm complete all as specified and directed. |
| 110 | Soap dish, Vitreous China white, approximate size 160x160x90mm complete all as specified. |
| 111 | 15mm bore, chromium plated, self cleaning water jet (Health Facuet) for EWCcomplete all as specified. |
| 112 | PVC connections 15 mm size with PTMT nutsof length 450mm complete all as specified and directed. |
| 113 | Grating doom 100mm size of PTMT (Minimum weight 25gms) complete all as specified and directed. |
| 114 | Vitreous China wash down water closet (pedestal pattern), white including traps, connection to drain or outgoing pipe, flushing pipe, anti-syphonage pipe complete including fittings, PVC white seat cover andchromium plated jet including PVC connection, fixedcomplete all as specified. |
| 115 | PVC valve less, crystal white, syphonic action type flushing cistern 10 litre capacity, superior quality, plunger type, low level, with inlet, ball valve, float and handle, 32 mm dia PVC long bend flush pipe 90cm long and 15 mm dia 600 mm long PVC connection with CP brass coupling nuts and PVC washers at both ends fixed all as specified. |
| 116 | Cast iron 100mm bore Spun cast soil, waste pipes, in any length with or without ears with lead joints, laid in trenches or in floors complete all as specified and directed. |
| 117 | Cast iron 75 mm bore Spun cast soil, waste pipes, in any length with or without ears with lead joints, laid in trenches or in floors complete all as specified and directed. |
| 118 | Bend 100mm bore (any radius), diminishing pieces or tapers (larger bore measured) complete all as specified and directed. |
| 119 | Cast iron floor trap 75 mm dia, with grating including jointing to waste pipe fixed in cement concrete type B-1 1:2:4 using 20mm graded crushed stone aggregate complete all as specified and directed. |
| 120 | Rotational moulded polyethylene water storage tank 250 Ltrs capacity four layered (ISI Marked) cylinderical vertical with closed top, hoisted and fixed in position with ball brass valve, high pressure with PVC float valve 20mm dia with polythene float and fly nut, tank nipples with check nuts and washers complete and making connections with existing water supply line complete all as specified. |
| 121 | Rolling and consolidating of formation surfaces in cutting with power roller 8 to 12 tonne capacity complete all as specified and as directed. |
| 122 | Soling (or sub base) 150mm thick (spread thickness) with broken stone boulders or quarred stone, interstices filled, surface formed and rolled and consolidated with 8 to 10 tonne power roller to reqd gradient and camber complete all as specified and as directed. |
| 123 | 150mm thick(compacted thickness) in two equal layers of 75 mm thick each) water bound macadum with coarse aggregate (Granite, trap, Basalt) of grading 2 (63 to 40mm Size) spread, watered, rolled with 8 to 12 tones power roller to required gradient and camber complete all as specified and as directed. |
| 124 | Preparation of unsurfaced WBM surface by brushing with wire brushes for removing caked mud etc, sweeping with brooms and finally fanning the cleaned surface with power compressor to remove all loose dirt etc. complete all as specified and applying evenly a priming/tack coat with faving bituminous cold emulsion 10 Kg per 10 sqm of road surface and, laying Bituminous premix semi dence asphaltic concrete 40 mm consolidated thickness with 5.5% binder content by weight of total mix,laid with self propelling mechanical paver, rolled and compacted to required camber and gradient complete all as specified and as directed. |
| 125 | 75mm thick, PCC 1:3:6 type C-2, using 40mm graded crushed stone aggregate as in path, finished surface even and fair complete all as specified and directed. |
| 126 | Continuous brick edging with burnt clay bricks of sub class \"B\" bricks laid dry on end vertically old size bricks complete all as specified and directed. |
| 127 | Reinforced cement concrete pipe class NP-3 laid and jonted complete, bore of pipe 600mm complete all as specified and directed. |
| 128 | Chequered cement concrete colouredtiles, homogenious texture glossy finished, chemically coated machine pressed 20 cm x 20cm x 25mm thick set, jointed and pointed in near cement slurry in floor with gray cement and pigment and including 15 mm thick cement screed in cement mortar 1:4complete all as specified and directed. |
| 129 | Concrete bed to drain pipes laid to falls including packing under and haunching against the sides of pipes after they are laid and tested in cement concrete 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) for 300mm bore pipe complete all as specified and directed. |
| 130 | Concrete bed to drain pipes laid to falls including packing under and haunching against the sides of pipes after they are laid and tested in cement concrete 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) for 150mm bore pipe complete all as specified and directed. |
| 131 | Salt glazed stone ware (SGSW) grade \"A\" drain pipes 300mm bore laid and jointed on concrete bed complete including testing complete all as specified and directed. |
| 132 | LLDPE septic tank designed to carry sewage and sludge water, comprising earth work , excevation, returning filling, disposal of surplus spoils to a distance not exc 50 mtr from starting point in any type of soil, PCC 1:4:8 type D-2 (using 40 mm graded crushed stone aggregate) in foundation, 200 mm thick, vent shaft, connections etc.for 25 users (4000liter capacity) including all fittings, fixtures, testing on completion complete all as specified. |
| 133 | Construction of soakage well (Brick construction) 3m dia and 4.50m deep below inlet pipe level (depth from inlet pipe to ground level 45cm), complete all as specified and shown on drg No. CEUZ/TD-1585/2021 sheet 1/4 to 4/4. |
| 134 | Point wiring with 1.5 Sqmm copper conductor FRLSH (Multistrand) PVC insulated unsheathed cable in and including PVC concealed conduit not less than 20mm dia and 2mm thick, medium grade with IS 9537 (Part-III) 1983 marking with all fittings/ accessories as specified in preamble 1 (a) to (q) of Section 19 of SSR Part-II, under heading point wiring and also including PVC insulated unsheathed 1.5 Sqmm copper multistranded conductor FLRSH as earth wire (green colour) connected to common earth dolly and including pressed steel terminal boxes made out of 1.20 mm thick mild steel sheet duly painted with one coat of red oxide primer for mounting of switches, sockets, fan regulators, light fittings etc. covered with 3mm thick plastic laminated sheet (ISI marked) for one light point or one fan point or one fan point through regulator or one bell point, controlled by one way switch/ push button complete all as specified and directed. |
| 135 | All as per serial item No \"134\" above, but for one 3 pin 5 Ampssocket outlet on the same board all as specified and directed. |
| 136 | All as per Srl item No.134 above but with 2.5 sqmm copper conductor for 15 Amp socket with 2.5 sqmm earth continuity copper conductor. |
| 137 | Switch piano flush type, single pole, one way, 5 Amps, all as specified. |
| 138 | Switch piano flush type, single pole, one way, 15 Amps, all as specified. |
| 139 | MCB TPN 63 Amp, 415 Volts complete all as specified and directed |
| 140 | MCB SPN 6 to 32 Amp, 240 Volts, 10 KA all as specified. |
| 141 | MCB SP 6 to 40 Amp, 240 Volts, 10 KA all as specified. |
| 142 | Sub main wiring with two single core PVC insulated cable 1100 volts grade with copper strandedFRLSH conductor of size 1.5 Sqmm (2 single run) with one continuous FRLSH copper earthing lead wire ofsize 1.5 Sqmm and drawn in and including 25 mm dia PVC conduit having wall thickeness not less than 2 mm thick concealed type medium grade with all accessories and connected to common earth dolly complete and as directed. Notes:-(Two run (each run of 1 RM) of 1.5 sqmm copper conductor andone RM of earth wire of 1.5 Sqmm alongwith one Run of PVC Conduit,shall be measured as one RM). |
| 143 | Sub main wiring with two single core PVC insulated cable 1100 volts grade with copper strandedFRLS conductor of size 4 Sqmm (2 single run) with one continuous FRLS copper earthing lead wire ofsize 4 Sqmm and drawn in and including 25 mm dia PVC conduit having wall thickeness not less than 2 mm thick concealed type medium grade with all accessories and connected to common earth dolly complete and as directed. Note:- Two run (each run of 1 RM) of 4 sqmm copper conductor andone RM of earth wire of 4 Sqmm alongwith one Run of PVC Conduit,shall be measured as one RM). |
| 144 | LED tube lights fitting 1x 22W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified. |
| 145 | Ceiling rose, 3 terminal, PVC/polycarbonate body (ISI marked), complete all as specified and directed |
| 146 | LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified. |
| 147 | LED light fitting 1x9W/1X10W bulkhead luminaires (6500k) including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size. all as specified. |
| 148 | Exhaust fan steel body 300 mm sweep with double bearing AC 230/240 Volts heavy duty 900 RPM complete with louvers, shutters, arrangement for wall mounting including grounting, holding down bolts, nuts, washers & provision of flaxible copper conductor cable three core 23/0.0076 size from ceiling rose to fan and PCC1:2:4 type B-1 (using 20mm graded crushed stone aggregate) grounting complete all as specified |
| 149 | Ceiling fans, complete with three blade, down rod, accessories 230V, 1200mm sweep, with Squirrel cage induction motor with provision of cable 3 core flexible copper conductor 23/0.0076 from ceiling rose to ceiling fan including fixing and connecting up of fan regulator complete all as specified. |
| 150 | MCB DB sheet metal enclosure single pole and neutral 12 way, 240V with 200 Amp bus bar and common neutral link all enclosed in standard steel sheet flush mounting type factory fabricatedAcrylic double door complete confirming to IP 42 complete all as specified and directed. |
| 151 | MCB DB sheet metal enclosure single pole and neutral 8 way, 240V with 200 Amp bus bar and common neutral link all enclosed in standard steel sheet flush mounting type factory fabricatedAcrylic double door complete confirming to IP 42 complete all as specified and directed. |
| 152 | MCB DB sheet metal enclosure single pole and neutral4 way 240V with 200 Amp bus bar and common neutral link all enclosed in standard steel sheet flush mounting type factory fabricatedAcrylic double door complete confirming to IP 42 complete all as specified and directed. |
| 153 | Supply, laying, jointing and testing, laid in trenches/road crossing/under floor/on walls/on poles including clamps or passing through pipes 11000 volts grade XLPE insulated, screened, PVC bedded,galvanised steel strip or wire armoured,electric power cables (heavyduty) withaluminium conductor, 11000 volts Earthed,grade cross sectional area 95Sqmm,3.0core complete all as specified and directed. |
| 154 | Supply, laying, jointing and testing, laid in trenches/road crossing/under floor/on walls/on poles including clamps or passing through pipes 1100 volts grade XLPE insulated, armoured heavy duty electric cable with stranded aluminium conductor of cross sectional area 300 Sqmm,3.5corecomplete all as specified and directed. |
| 155 | Supply, laying, jointing and testing, laid in trenches/road crossing/under floor/on walls/on poles including clamps or passing through pipes 1100 volts grade XLPE insulated, armoured heavy duty electric cable with stranded aluminium conductor of cross sectional area 120 Sqmm, 3.5corecomplete all as specified and directed. |
| 156 | Supply, laying, jointing and testing, laid in trenches/road crossing/under floor/on walls/on poles including clamps or passing through pipes 1100 volts grade XLPE insulated, armoured heavy duty electric cable with stranded aluminium conductor of cross sectional area 70 Sqmm,3.5corecomplete all as specified and directed. |
| 157 | Supply, laying, jointing and testing, laid in trenches/road crossing/under floor/on walls/on poles including clamps or passing through pipes 1100 volts grade XLPE insulated, armoured heavy duty electric cable with stranded aluminium conductor of cross sectional area 50 Sqmm,3.5corecomplete all as specified and directed. |
| 158 | Supply, laying,jointing and testing, laid in trenches/road crossing/under floor/on walls/on poles including clamps or passing through pipes 1100 volts grade XLPE insulated, armoured heavy duty electric cable with stranded aluminium conductor of cross sectional area 16 Sqmm, 4corecomplete all as specified and directed. |
| 159 | Supply, laying, jointing and testing, laid in trenches/road crossing/under floor/on walls/on poles including clamps or passing through pipes 1100 volts grade XLPE insulated, armoured heavy duty electric cable with stranded aluminium conductor of cross sectional area 25 Sqmm, 2corecomplete all as specified and directed. |
| 160 | Supply, laying, jointing and testing, laid in trenches/road crossing/under floor/on walls/on poles including clamps or passing through pipes 1100 volts grade XLPE insulated, armoured heavy duty electric cable with stranded aluminium conductor of cross sectional area 10 Sqmm, 2corecomplete all as specified and directed. |
| 161 | Supply, laying, jointing and testing, laid in trenches/road crossing/under floor/on walls/on poles including clamps or passing through pipes 1100 volts grade XLPE insulated, armoured heavy duty electric cable with stranded aluminium conductor of cross sectional area 6 Sqmm, 2corecomplete all as specified and directed. |
| 162 | GI Light grade pipe of size 80mm bore dia galvanized with all fittings and fixed complete to wall and ceiling or laid in floor complete all as specified and directed. |
| 163 | GI Light grade pipe of size 50mm bore dia galvanized with all fittings and fixed complete to wall and ceiling or laid in floor complete all as specified and directed. |
| 164 | Sand cushioning for underground cable 8cm before laying the cable and 15cm after laying and stretching the cable and pulling down to 18cm for measurement complete all as specified and as directed. |
| 165 | Sub class \"B\" bricks, well burnt as in mechanical protection to cable, laid dry, flat with width equal to the length of brick complete all as specified and directed. |
| 166 | Earthing complete with galvanised steel earth plate electrode 600mmx600mmx6mm thick buried directed in ground (earth plate not less than 2.25m deep below normal ground level) with top edge of the plate not less than 1.5m below normal ground level) connected to and including galvanised earth lead wire 4.0 mm dia by means of bolts, nuts, check nuts nuts, check nuts and washers of galvanised iron including PCC 1:2:4 in pit, angle iron 25x25x3mm frame work with precast RCC 1:2:4 cover reinforced with 8mm dia TMT bars @ 150mm C/C both ways and 12 mm dia MS fabricated handle, mediumgrade GI watering ipe 20mm bore with funnel, wire mesh and light grade GI protection pipe 40mm bore upto 5m length for drawing in earth lead wire, salt, charcoal, etc. Including excavation and earth work in any type of soil, removal of surplus spoil to a distance not exc. 50m complete all as shown in electrical plate No 3 of MES schedule 2009 (Pt-I) and connected to main control board all as specified including testing on completion. |
| 167 | Earthing complete with galvanised steel earth plate electrode 600mmx600mmx6mm thick buried directed in ground (earth plate not less than 2.25m deep below normal ground level) with top edge of the plate not less than 1.5m below normal ground level) connected to and including galvanised strip 32x6mm by means of bolts, nuts, check nuts nuts, check nuts and washers of galvanised iron including PCC 1:2:4 in pit, angle iron 25x25x3mm frame work with precast RCC 1:2:4 cover reinforced with 8mm dia TMT bars @ 150mm C/C both ways and 12 mm dia MS fabricated handle, mediumgrade GI watering ipe 20mm bore with funnel, wire mesh and light grade GI protection pipe 40mm bore upto 5m length for drawing in earth lead wire, salt, charcoal, etc. Including excavation and earth work in any type of soil, removal of surplus spoil to a distance not exc. 50m complete all as shown in electrical plate No 3 of MES schedule 2009 (Pt-I) and connected to main control board all as specified including testing on completion. |
| 168 | Supply and fixing LED street light fitting 60 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 66 protection including making necessary connection with suitable copper cable complete all as specified and directed. |
| 169 | GI tubing bracket of 40 mm dia, light grade 1.2 mtr long having 120 degree angle and fixed on pole including clamps, nut, bolts and washer for fixing of security light complete all as specified and directed. |
| 170 | Supply and fixing LED flood light 170 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp including making necessary connection with suitable copper cable complete all as specified and directed. |
| 171 | Supply and fix glass fiber reinforced UV protected poly carbonate junction box IP-66/67 dust/water proof, with knockouts for cable entry of size 10-16 sqmm cable to mounting on the street light pole of size155mm x 210mm x 92mm complete with 01 No MCB SP 10 Amps and four no Al bus bar with provison of cable glands and necessary clamps to fix on tubluar pole all as specified and directed. |
| 172 | S & F light regulator dimmer (GLS 4 conventional transformer) for inocandensent high voltage , halogen lamps and low voltage halogen lamp with conventional transformers complete all specified and directed. The minimum light out part lever can be adjusted between 1 and 10% of maximum light out level. A green power on LED indicator the power status of the max load is 1000VA. |
| 173 | Supply & installation, testing and commisioning of LT panel board outdoor type floor mounted having independent compartment for bus bar incoming feeder and each out going feeders, dust and vermin proof factory made , fabricated outdoor type of 3.15 mm thick CRA sheet suitbale for 3 phase , 415 volts 50 Hz AC supply, bus bar chamber with aluminium bus bar 600 Amp rating for 3 phase and 4 wire system duly insulated with heat shrinkable type sleeves as per colour code and proper vantilation comprising of folowing:-(a) MCCB 4 pole 350 Amp,415 Volt , 50 Hz, 35 KA-01 Nos. (Incoming)(b) MCCB 3 pole 250 Amp,415 Volt , 50 Hz, 25 KA-01 Nos. (outgoing). (c) MCCB 3 pole 100 Amp,415 Volt , 50 Hz, 16 KA-01 Nos. (outgoing).(d) Digital ammeter with CT ratio 400/5 Amps with selector switch (0-500 Ams)-01 No.(e) Digital voltmeter 0-500 V with selector switch-01 No.(f) LED indicator lamp with holder 03 Nos-01 set.(g) Connector with suitable size bus barNote: (i) The panel shall be front operated with cable entry from te bottom with cable glands. (ii) Fabrication of panel box to be done by CPRI approved manufactrer.(iii) Cost of earth work and construction of platform for panel, brick masonary in cement mortar 1:6 withfoundation PCC 1:4:8 type D-2 including plaster work, PCC coping 1:2:4 (20mm thick curshed stone aggregate), deemed to be included in this item rate. |
| 174 | Supply & installation, testing and commisioning of LT panel board outdoor type floor mounted having independent compartment for bus bar incoming feeder and each out going feeders, dust and vermin proof factory made , fabricated outdoor type of 3.15 mm thick CRA sheet suitbale for 3 phase , 415 volts 50 Hz AC supply, bus bar chamber with aluminium bus bar 600 Amp rating for 3 phase and 4 wire system duly insulated with heat shrinkable type sleeves as per colour code and proper vantilation comprising of folowing:-(a) MCCB 4 pole 350 Amp,415 Volt , 50 Hz, 35 KA-01 Nos. (Incoming)(b) MCCB 3 pole 250 Amp,415 Volt , 50 Hz, 25 KA-01 Nos. (outgoing). (c) MCCB 3 pole 100 Amp,415 Volt , 50 Hz, 16 KA-01 Nos. (outgoing).(d) Digital ammeter with CT ratio 400/5 Amps with selector switch (0-500 Ams)-01 No.(e) Digital voltmeter 0-500 V with selector switch-01 No.(f) LED indicator lamp with holder 03 Nos-01 set.(g) Connector with suitable size bus barNote: (i) The panel shall be front operated with cable entry from te bottom with cable glands. (ii) Fabrication of panel box to be done by CPRI approved manufactrer.(iii) Cost of earth work and construction of platform for panel, brick masonary in cement mortar 1:6 withfoundation PCC 1:4:8 type D-2 including plaster work, PCC coping 1:2:4 (20mm thick curshed stone aggregate), deemed to be included in this item rate. |
| 175 | Supply & installation, testing and commisioning of LT panel board outdoor type floor mounted having independent compartment for bus bar incoming feeder and each out going feeders, dust and vermin proof factory made , fabricated outdoor type of 3.15 mm thick CRA sheet suitbale for 3 phase , 415 volts 50 Hz AC supply, bus bar chamber with aluminium bus bar 200 Amp rating for 3 phase and 4 wire system duly insulated with heat shrinkable type sleeves as per colour code and proper vantilation comprising of folowing:-(a) MCB TPN 16 Amp, 415 Volt , 50 Hz, 16 KA-01 Nos. (incoming). (b) MCB SPN 20 Amp 230Volt, 10 KA-04 Nos. (outgoing).(c) Digital ammeter with CT ratio 200/5 Amps with selector switch-01 No.(d) Digital voltmeter 0-500 V with selector switch-01 No.(e) LED indicator lamp with holder 03 Nos-01 set.(f) Timer switch with contactor 16 Amps-01 set(g) Connector with suitable size bus barNote: (i) The panel shall be front operated with cable entry from te bottom with cable glands. (ii) Fabrication of panel box to be done by CPRI approved manufactrer.(iii) Cost of earth work and construction of platform for panel, brick masonary in cement mortar 1:6 withfoundation PCC 1:4:8 type D-2 including plaster work, PCC coping 1:2:4 (20mm thick curshed stone aggregate), deemed to be included in this item rate. |
| 176 | Supply & installation, testing and commisioning of LT panel board outdoor type floor mounted having independent compartment for bus bar incoming feeder and each out going feeders, dust and vermin proof factory made , fabricated outdoor type of 3.15 mm thick CRA sheet suitbale for 3 phase , 415 volts 50 Hz AC supply, bus bar chamber with aluminium bus bar 200 Amp rating for 3 phase and 4 wire system duly insulated with heat shrinkable type sleeves as per colour code and proper vantilation comprising of folowing:-(a) MCB TPN 16 Amp, 415 Volt , 50 Hz, 16 KA-01 Nos. (incoming). (b) MCB SPN 20 Amp 230Volt, 10 KA-03 Nos. (outgoing).(c) MCB SPN 63 Amp 230Volt, 10 KA-01 Nos. (outgoing). (d) Digital ammeter with CT ratio 200/5 Amps with selector switch-01 No.(e) Digital voltmeter 0-500 V with selector switch-01 No.(f) LED indicator lamp with holder 03 Nos-01 set.(g) Timer switch with contactor 16 Amps-01 set(h) Connector with suitable size bus barNote: (i) The panel shall be front operated with cable entry from te bottom with cable glands. (ii) Fabrication of panel box to be done by CPRI approved manufactrer.(iii) Cost of earth work and construction of platform for panel, brick masonary in cement mortar 1:6 withfoundation PCC 1:4:8 type D-2 including plaster work, PCC coping 1:2:4 (20mm thick curshed stone aggregate), deemed to be included in this item rate. |
| 177 | Supply, laying and testing Steel water tubing \"medium grade\" Galvanized with screwed and socket joints, with all fittings such as tees, bends, unions, elbows, reducers etc laid in trenches of bore 80 mm, complete, all as specified. |
| 178 | Supply, laying and testing Steel water tubing \"medium grade\" Galvanized with screwed and socket joints, with all fittings such as tees, bends, unions, elbows, reducers etc laid in trenches of bore 50 mm, complete, all as specified. |
| 179 | Supply, laying and testing Steel water tubing \"medium grade\" Galvanized with screwed and socket joints, with all fittings such as tees, bends, unions, elbows, reducers etc laid in trenches of bore 25 mm, complete, all as specified. |
| 180 | Construction of brick masonery valve pits of size (900x900x900)mm (internal diamension)with brick work in cement mortar (1:4), plastering all wall surfaces internally and flush pointing to brickwork externally as the work proceess complete including excavation and earth work, concrete work,including angle iron 50x50x6mm frame, MS sheet cover 3.15 thick with 12mm dia handle, locking arrangement and painting with two coas of synthetic enamel paint over a coat of red oxide zinc chrome primercomplete all as shown on drg No CEUZ/TD/1500/15 amended upto date complete as specified and directed. |
| 181 | Construction of brick masonery valve pits of size (600x600x600)mm (internal diamension)with brick work in cement mortar (1:4), plastering all wall surfaces internally and flush pointing to brickwork externally as the work proceess complete including excavation and earth work, concrete work,including angle iron 50x50x6mm frame, MS sheet cover 3.15 thick with 12mm dia handle, locking arrangement and painting with two coas of synthetic enamel paint over a coat of red oxide zinc chrome primercomplete all as shown on drg No CEUZ/TD/1500/15 amended upto date complete as specified and directed. |
| 182 | Rotational moulded polyethylene water storage tank 10000 Ltrs capacity four layered (ISI Marked) cylinderical vertical with closed top, hoisted and fixed in position with ball brass valve, high pressure with PVC float valve of suitable diaa with polythene float and fly nut, tank nipples with check nuts and washers complete and making connections complete all as specified. |
| 183 | Supply, installing, commisioning & testing of Diesel Engine driven Generator set of 20 KVA with AMF panel complete with suitable acoustic enclosures all as per central pollution control board guide lines, 50 cycle per second with 0.8 power factor, engine as per IS-10001/10002 and alternator as per IS-13364 complete. The alternator of rating 20 KVA of Generator set shall be directly coupled with Diesel Engine mounted on common base plate with alternator and all as specified and comprising of the following:- |
| 184 | A. EngineInline type, 4 cylinder diesel engine of of suitable BHP rating at 1500 RPM as per ISO 3046/BS-5514/649 or 10002 direct injection type with turbo charger & water cooled engine electric starting system, arrangement of starting and the engine shall be capable of running 12 hours continiously and with 10% of overloading for one hours in each 12 hpurs running. The engine recommendations. Engine shall be directly coupled with alternator mounted on common base plate with the following:-(a) 1 Nos 12 volts 100 AH batteries with battery charger. The battery charger shall be able to charge the battery at all time whenever electric supply is given to battery charger through control panel.(b) Heavy duty industrial silencer.(c) Fly wheel with coupling bolts.(d) Lub oil filter.(e) Instrument panel comprising of microprocessor based controller for measuring paramenters like coolent temperature, Running hours, lubricating oil pressure etc.(f) Engine speed mechanical /easy governor class A, Governing as per BS 5514 (g) Air filter (Dry type)(h) Turbocharger of suitable capacity(i) Gear pump for forced feed lubrication(j)Fuel injection Pump(k) Fuel filter double bowl |
| 185 | (l) Raditors(m)Flexible rubber coupling(n) Set of fuel pipes of suitable length(o)Base plate(p)Fuel tank capacity as per manufacturer design with all connecting pipe & fabricated MS stand including level gauge.(q) Anti vibrating pads& mounting for the genertors set, Engine and alternator(r) Legging of exhaust manifold with asbestos rope to exposed pipes(s) Flexible exhaust pipe with end flanged of suitable size. |
| 186 | B. Alternator Alternator of rating capacity (20 KVA) & capable to take 10% extra load at every 12 hours interval for one hours, 3 phase, 4 wire, 50 Hz, 415 volts, 0.8 power factors. 1500 RPM self excited self regulated required to be coupled with above engine. The alternators shall be comforming to IS-4722 & IS-4728 as per following specification.(a) Type: Sailent poles, single bearing brushess type suitable for direct coupling to engine.(b) Rating: Guaranted to deliver required output at the ambient temp conditions. Suitable for an over load of 10% 1 hour in every 12 hours operations.(c) Voltage Regulation: Provided with fast response thyristors type electronics automatic voltage regulators, which holds output voltage with in desired limits. (+/-1%)(d) Self excited- self regulated(e) Alternator loading: Suitable for taking rated load immediately after machines reaches rated voltage and speed.(f) Vibration: Suitable for direct coupling with engine and mounted on common MS Channel base frame.(g) Enclousures: Screen protected drip proof enclosure with IP-23 Degree of protection.(h) Cooling: Liquid cooled type.(j)Control panel shall be provided withsuitable PC controller and digital display for measuring of line/phase voltage/currents, frequency etc. |
| 187 | C. AMF Panel (i) Standard control panel for DG set shall be made of fabricated sheet cubical type with front hinged cover, wtih microporcessor based controller with folllowing features:-(a) State of the art compact microposseor based fully configurable technology.(b) Integration of all engine and alternator parameters.(c) For ease of viewing, high performance graphical LCD and prominent display.(d) Event logging history for easy of maintenance/service.(e) Capability of with standingwide range of operating temp.(f) Individual touch bottons for manual, auto and test mode.(g) LED indications for genset status and alarms.(h) Battery conditins monitoring.(j) Statistical cumulative counters like, No of starts, Engine run Hrs, Kwh.(j) Setting provision for different parameters on front panel.(k) Two nos microprocessors based, MCCB 63 Amps, 16 KA breaking capacity, one for main supply and other for DG set supply.(l) Two nos contractors of suitable capacity for main & DG.(m) AI bus bars of 400 Amps capacity provided with termination. |
| 188 | (ii)Display Parameters(a) Electrical parameters: Phase voltage, line current, frequency, average voltage, average current, KW, KWH, KVA, KVAR, Power factor, earth fault current.(b) Mechanical Parameters:Lube oil pressure coolant, Temp, Engine speed, Fuel status, Engine run hours, Battery Voltage.(iii) Protection:(a) Electrical protections: Under/over voltage,under/over frequency, phase failure. Phase seqencer reverse, over current, over KW.(b) Mechaical protections:Under/over spped, low lube oil pressure, High engine coolant temp, Low fuel level alarm, start/stop fail, charging alternator fail.(c) Cable entry gland plate without cable glands.D. FoundationDG Set shall be installed on new foundation block as per manufactures recommendations including excavation works PCC etc for foundations, provision of cable ducts, making good any damage to existing structure, fuel piping from fuel tank to generator set with medium grade GI tubing and cold water piping system (Medium grade GI tubiing from nearest water point to radiator of engine with brass tap and stop cocks and fittings complete connecting the existing earthing strips to control panel, DG set and generator. |
| 189 | Supply, installation, commissioning of Water cooler fully stainless steel, electric driven single phase having storage capacity of 80 litre and nominal cooling capacity of 40 Litres per hour complete all as specified and directed. |
| 190 | Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 2 KVA complete all as specified and directed. |
| 191 | Supply and fix 5mm thick aluminium sheet including necessary fixing arrangement complete all as directed. |
| 192 | Supply and filling gravel of size exceeding 9mm but not exceeding 20mm complete all as directed. |
| 193 | Supply and fixing 30mm thick rubber lining for firing point complete all as specified and directed. |
| 194 | Grassing with Pusa selection No. 1 type grass including watering and maintenance of berm lawn till completion weeds and fit for moving including fine dressing of ground in requred level and flooding with water and the component mentioned should include termite treatement of dibbled area chemical fertilizers and vermi compost/green magic etc; complete all as specified and directed. |
| 195 | Supply and fix rubber lining , 10 to 12mm thickself sealing rubber complete all as per Baffle Range Manual, 2020 and TBRL Chandigarh instruction and shall meet the test requirements mentioned therein. |
| 196 | Good earth i.e. natural, fertile, friable and loamy soil of good quality to support healthy growth of pusa grass free from stones, rubbish, roots, kankar, harmful salts, or any other deleterious matter) in and including decayed formyard manure mixing in the proporation of two parts of good earth to one part of manure by valume for filling obtained from out side MoD Land to site including spreading, levelling in layer not exceeding 25cm, ramming and consolidation complete all as specified and directed. |
| 197 | Deduction to be made from BOQfor Sch \"A\" Part -II (Schedule of credit) Amount during AOC.Note: Tenderers shall not quote for this schedule. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
| 5 | Click here to download tender document | Tender Documents |
| 6 | Click here to download tender document | Tender Documents |
| 7 | Click here to download tender document | Tender Documents |
| 8 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy