Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Demolishing brick tiles covering in terracing including stacking of serviceable material and disposal of unserviceable material outside MoD land complete all as specified and directed. |
| 2 | Demolishing mud phaska in terracing and disposal of material outside MoD landcomplete all as specified and directed. |
| 3 | Roughening of surfaces of old concrete slab by wire brushing, sweeping, cleaning and washing down with waterto remove all loose dust etc. and brushing neat cement slurry @ 3.00 kg/Square Metre on roof surface, etc complete all as specified and directed . |
| 4 | M&L for providingCement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) roof for water proofing treatment withas in padding on roof,projections of roof etccomplete all as specified and directed. |
| 5 | Providing and laying APP (Atactic Polypropylene Polymer) modified prefabricated five layer 3 mm thick water proofing membrane, black finished reinforced with non-woven polyester matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the same membrane manufacture of density at 25°C, 0.87-0.89 kg/ litre and viscocity 70-160 cps. Over the primer coat the layer of membrane shall be laid using Butane Torch and sealing all joints etc, and preparing the surface complete. The vital physical and chemical parameters of the membrane shall be as under : Joint strength in longitudinal and transverse direction at 23°C as 650/ 450N/ 5cm. Tear strength in longitudinal and transverse direction as 300/ 250N. Softening point of membrane not less than 150°C. Cold flexibility shall be upto -2°C when tested in accordance with ASTM, D - 5147. The laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane3 mm thickcomplete all as specified and directed. |
| 6 | Providing and fixing Heat Resistant Terrace Tiles (300 mm x 300 mm x 20 mm) with SRI (solar refractive index) > 78, solar reflection > 0.70 and initial emittance > 0.75 on waterproof and sloped surface of terrace, laid over and including 20 mm thick cement sand mortar in the ratio of 1:4 using liquid water proofing compound as per manufacturers instructions(1 cement : 4 coarse sand) and grouting the joints with mix of white cement & marble powder in ratio of 1:1, including rubbing and polishing of the surface upto 3 cuts complete, including providing skirting upto 150 mm height along the parapet walls in the same mannercomplete all as specified and directed. |
| 7 | Demolishing brick work built inIn cement mortar manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material outside MoD land as per direction of Engineer-in-charge complete all as specified and directed. |
| 8 | M&L Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand)complete all as specified and directed. |
| 9 | Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design In 75x75 mm deep chase complete all as specified and directed. |
| 10 | Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete all as specified and directed. |
| 11 | Dismantling or taking down old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead complete all as specified and directed. |
| 12 | M&L 15 mm cement plaster on brick walls of mix 1:4 (1 cement: 4 fine sand) complete all as specified and directed. |
| 13 | M&L 15 mm cement plaster on brick walls of mix 1:6 (1 cement: 6 fine sand) complete all as specified and directed. |
| 14 | M&L rendering 12mm thick on ceiling in cement mortar 1:3 with a floating coat complete all as specified and directed. |
| 15 | M&L forchipping of spalled and loose concrete and cleaning rust from reinforement by sand blasting scrubbing down concrete surface with wire brushes cleaning with water allowed to dry and applying a layer of zinc rich epoxy primer as antirust on all exposed reinforcement followed by a layer of bounding coat of approved epoxy adheisve on complete exposed surfaces of concrete to be gunited all as specified and applying two layers of guniting over steel welded mesh 2mm dia of wire and aperature 75mm, avarage thickness of gunite n.exc 40mm thickin cement mortor (1:2) using OPC 43 grade cement mixed with polycrete admixture @ 7% by weight of cement or as per manufacturer instructions and finally applying cement plaster over gunite surface of required thickness to giveeven uniform and smooth finish conforming to proper geometrics in cement mortor (1:3) to match the existing surface as in sides and soffits etc of slabs, chajjas, fins, facias,parapets, lintels, columns and beams etc complete including necessary scaffolding, shuttering, necessary chases to brick work or RCC members at any height upto 6 storey building including removing of small trees shrubs etc complete all as specified and directed. |
| 16 | Providing and laying cement concrete inparapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing: 1:1½:3 (1 cement : 1½ coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) complete all as specified and directed. |
| 17 | Dismantling steel work in single sections including dismembering and stacking within 50 metres lead in Channels, angles, tees and flats etc complete all as specified and directed. |
| 18 | Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2 mm and braced with flat iron diagonals 20x5 mm size, with top and bottom rail of T-iron 40x40x6 mm, with 40 mm dia steel pulleys, complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer complete all as specified and directed. |
| 19 | S&F Structural steel work in single section, as in doors,gate etc fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer complete all as specified and directed. |
| 20 | M&L for Applying primer With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works and applying two coats of synthetic enemel paint complete all as specified and directed |
| 21 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats with shuttersarchitrave, holdfasts etc. complete and stacking within 50 metres leadof area 3 sq. metres and below all as specified and directed. |
| 22 | Providing and fixing Powder coated aluminium (minimum thickness of powder coating 50 micron) Aluminium works For frame andshutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) complete all as specified and directed. |
| 23 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm) complete all as specified and directed. |
| 24 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately) of Second class teak wood complete all as specified and directed. |
| 25 | Providing and fixing ISI marked 35 mm thick flush door shutters conforming to IS :2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters including ISI marked Stainless Steel butt hinges complete all as specified and directed |
| 26 | Providing and fixing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embedding in cement concrete block 30x10x15cm 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) complete all as specified and directed. |
| 27 | Providing and fixing Brass 100mm mortice latch and lock with 6 levers without pair of handles (best make of approved quality) for aluminium doors including necessary cutting and making good etc. complete all as specified and directed. |
| 28 | Providing and fixing in repair Brass 100mm mortice latch and lock with 6 levers with pair of handles (best make of approved quality) for doors including necessary cutting and making good etc. complete all as specified and directed. |
| 29 | Providing and fixing aluminium tower bolts 200x10 mm, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete all as specified and directed |
| 30 | Providing and fixing aluminium handles,150 mm size ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete all as specified and directed |
| 31 | Providing and fixing aluminium sliding door bolts,300X16 mm size ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc complete all as specified and directed. |
| 32 | Applying priming coat With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) and applying two coats of synthetic enemel paint complete all as specified and directed |
| 33 | Disconnecting damaged overhead/terrace PVC water storage tank of any size from water supply line and removing from the terrace including shifting at ground level as per direction of Engineer-in-charge complete all as specified and directed. |
| 34 | Providing and placing 1000 Ltr capacity on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank complete all as specified and directed. |
| 35 | Dismantling 15 to 40 mm dia G.I. pipe including stacking of dismantled pipes (within 50 metres lead) as per direction of Engineerin-Charge. |
| 36 | Providing and fixing G.I. pipes 25 mm dia nominal bore with G.I. fittings and clamps,i/c cutting and making good the walls etc. Exposed on wall complete all as specified and directed. |
| 37 | Providing and fixing G.I. pipes 40 mm dia nominal bore with G.I. fittings and clamps,i/c cutting and making good the walls etc. Exposed on wall complete all as specified and directed. |
| 38 | Providing and fixing 25 mm nominal bore gun metal gate valve with C.I. wheel of approved quality (screwed end)complete all as specified and directed. |
| 39 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) 40 mm nominal bore complete all as specified and directed. |
| 40 | Dismantling aluminium/ Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable material and stacking of serviceable material with in 50 meters lead as directed by Engineer-in-charge complete all as specified and directed. |
| 41 | Providing and fixing false ceiling tiles at all heights with GRG(Glass fibre Reinforced Gypsum) with semi perforated 12 mm thick micro tegular edged GRG false ceiling of size 595X595 mm of approved texture, design and patterns having moisture content less than 2%,humidity resistance of 99%,NRCO.50 to 0.75 as per IS 8225:1987,Noncombustible as per BS 476(part-4)-1970 and light reflectance of 85% (minimum) to be laid in true horizontal level suspended or interlocking metal T grid of hot dipped galvanized iron section of 0.33 mm thick(galvanized @120 gms per sqm including both sides) comprising of main T runner of size 15X32 mm of length 3000 mm, cross T of size 15X32 mm of length 600 mm to form grid module of size 600x600mm,suspended from ceiling using galvanized mild steel items( galvanizing @80 gms per Sqm) i.e 50 mm long,8 mm outer dia meter M-6 dash fastners,6 mm dia fully threaded hanger rod up to 1000 mm length and L-shape level adjuster of size 85X25X2mm. Galvanized iron perimeter wall angle of size 24X24X0.40mm of length 3000 mm to be fixed on periphery wall/partition with the help of plastic rawl plugs at 450 mm centre to centre and 40 mm long dry wall wood screws. The work shall be carried out as per specifications, drawing and as per directions of Engr-In-charge complete all as specified and directed. |
| 42 | M&L for Finishing walls with Acrylic Smooth exterior paint of required shade on New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) complete all as specified and directed. |
| 43 | M&L Distempering two coats with 1st quality acrylic distemper, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour complete all as specified and directed. |
| 44 | M&L White washing with lime to give an even shadeon New work (three or more coats) complete all as specified and directed. |
| 45 | M&L for Polishing on wood work with ready made wax polish of approved brand and manufacture on Old work complete all as specified and directed. |
| 46 | completeRemoving dry or oil bound distemper and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete all as specified and directed |
| 47 | Distempering with 1st quality acrylic distember (Ready mix) having VOC content less than 50 grams/ litre of approved brand and manufacture to give an even shade with two coats on old works complete all as specified and directed. |
| 48 | Complete removal of existing treatments andFinishing walls and soffits of chajjas,roof projection etc with Acrylic Smooth exterior paint of two coats of required shade on Old work by applying @ 1.67 ltr/ 10 sqm) complete all as specified and directed. |
| 49 | Supplying and fixing in repair rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 80x1.25 mm M.S. laths with 1.25 mm thick top cover complete all as specified and directed. |
| 50 | Providing and fixing ball bearing for rolling shutters complete all as specified and directed. |
| 51 | Extra for providing mechanical device chain and crank operation for operating rolling shutters Exceeding 10.00 sqm and upto 16.80 sqm in the area complete all as specified and directed. |
| 52 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade Two or more coats on old work over an under coat of suitable shade with ordinary paint of approved brand and manufacture complete all as specified and directed |
| 53 | Providing and fixing 100 mm sand cast Iron grating for gully trap complete all as specified and directed. |
| 54 | Dismantling C.I. or asbestos rain water pipe with fittings and clamps including stacking the material within 50 metres lead 100 mm dia pipe complete all as specified and directed. |
| 55 | Dismantling C.I. or asbestos rain water pipe with fittings and clamps including stacking the material within 50 metres lead 75 mm dia pipe complete all as specified and directed. |
| 56 | Providing and fixing soil, waste and vent pipes 100 mm dia Sand cast iron S&S pipe as per IS: 1729 complete all as specified and directed. |
| 57 | Providing and fixing soil, waste and vent pipes 75 mm dia Sand cast iron S&S pipe as per IS: 1729 complete all as specified and directed. |
| 58 | Providing and fixing M.S. holder-bat clamps of approved design to Sand Cast iron/cast iron (spun) pipe embedded in and including cement concrete blocks 10x10x10 cm of 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including cost of cutting holes and making good the walls etc For 100 mm dia pipe complete all as specified and directed. |
| 59 | Providing and fixing M.S. holder-bat clamps of approved design to Sand Cast iron/cast iron (spun) pipe embedded in and including cement concrete blocks 10x10x10 cm of 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including cost of cutting holes and making good the walls etc For 75 mm dia pipe complete all as specified and directed. |
| 60 | Providing and fixing plain bend of required degree 100 mm dia Sand cast iron S&S as per IS - 1729 complete all as specified and directed. |
| 61 | Providing and fixing bend of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete 100 mm diaSand cast iron S&S as per IS - 1729 complete all as specified and directed. |
| 62 | Providing and fixing bend of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete 75 mm diaSand cast iron S&S as per IS - 1729 complete all as specified and directed. |
| 63 | Providing and fixing double equal junction of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete100x100x100x100 mm Sand cast iron S&S as per IS - 1729 complete all as specified and directed. |
| 64 | Providing and fixing double equal junction of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete75X75X75X75 mm Sand cast iron S&S as per IS - 1729 complete all as specified and directed. |
| 65 | Providing lead caulked joints to sand cast iron/centrifugally cast (spun) iron pipes and fittings of diameter : 100 mm complete all as specified and directed. |
| 66 | Providing lead caulked joints to sand cast iron/centrifugally cast (spun) iron pipes and fittings of diameter : 75 mm complete all as specified and directed. |
| 67 | Providing and fixing M.S. stays and clamps for sand cast iron/ centrifugally cast (spun) iron pipes of diameter 100 mm complete all as specified and directed. |
| 68 | Providing and fixing M.S. stays and clamps for sand cast iron/ centrifugally cast (spun) iron pipes of diameter75 mm complete all as specified and directed. |
| 69 | Painting sand cast iron/ centrifugally cast (spun) iron soil, waste vent pipes and fittings with two coats of synthetic enamel paint of any colour such as chocolate grey, or buff etc. over a coat of primer (of approved quality) for new work 75 mm diameter pipe complete all as specified and directed. |
| 70 | Painting sand cast iron/ centrifugally cast (spun) iron soil, waste vent pipes and fittings with two coats of synthetic enamel paint of any colour such as chocolate grey, or buff etc. over a coat of primer (of approved quality) for new work 100 mm diameter pipe complete all as specified and directed. |
| 71 | S&F Cast iron cowl to pipes 100 mm size complete all as specified and directed. |
| 72 | S&F Cast iron cowl to pipes 75 mm size complete all as specified and directed. |
| 73 | Demolishing cement concrete Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge complete all as specified and directed. |
| 74 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size as in base of flooring complete all as specified and directed. |
| 75 | M&L PCC 1:1.5;3 type A-1 as in Kerb,bounding of edges of interlocking tiles,coping and the like including watering & lightly rounded or chamfered angles and throating including centring and shuttering. complete all as specified and directed. |
| 76 | Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand). Dark shade pigment using ordinary cement all as specified and directed |
| 77 | S&F Factory made precast heavy duty drain/ manhole covers with MS frame and reinforcementas per IS 12592 (2002) complete all as specified and directed. |
| 78 | Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial leadout side the MOD land, for all leads including all lifts involved complete all as specified and directed. |
| 79 | Dismantling roofing including ridges, hips, valleys and gutters etc., and stacking the material within 50 metres lead of G.S. Sheet complete all as specified and directed. |
| 80 | M&L for Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineerin- charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required complete all as specified and directed. |
| 81 | M&L for wiring for light point/fan point/exhaust fan point , call bell point with 1.5 Sqmm PVC insulated FRLS unsheathed copper conductor cable of size 1.5 sqmm including earth wire of size 1.5 Sqmm FRLS PVC insulated copper conductor single core cable insurface/ concealed /PVC conduit / PVC caping as per site requirement as directed of sutable size 25/32mm/casing caping of suitable size including powder coted(1.2mm thick) Metal Flush GI sheet box and white modular Inner/Outer cover plate with frame,including cutting chases for conduitandmaking good to wall and ceiling Taking down old unservicable point wiring rate to be included in quoted rate complete all as specified and directed. |
| 82 | One light point or one fan point/exhaust fan controlled by one 5 Amps switch complete all as specified and directed . |
| 83 | One 3 pin socket out let 5 Amps on same board complete all as specified and directed . |
| 84 | One 3 pin socket out let 5 Amps on Independent board complete all as specified and directed . |
| 85 | All as per item no.81.00 but wiring 2.5 sqmm for 15 amp power point and earth wiring2.5 sqmm complete all as specified and directed . |
| 86 | M&L for wiring forACpoint with 2x4 Sqmm FRLS PVC insulated copper conductor single core cable in surface/recessed existing conduit alongwith 1x 4 Sqmm FRLS PVC insulated copper conductor cable single core for loop earthing as required complete all as specified and directed . |
| 87 | S&F modular switch single pole one way 6 Amps 1 module complete all as specified and directed |
| 88 | S&F modular switch single pole one way 16 Amps 1 module complete all as specified and directed |
| 89 | Supply and fix modular socket 6 amp-2/3 pin combined 2 module complete all as specified and directed |
| 90 | M&L of modular socket 6 A/16 amp -2/3 pin combined 2 module complete all as specified and directed |
| 91 | S&F in replacement of fan step regulator 120W. 2 module complete all as specified and directed . |
| 92 | S&F Telephone socket jack RJ 11 with shutter complete all as specified and directed . |
| 93 | S&F Ceiling rose, 3 pin/PVC/polycarbonate, isolated body complete all as specified and directed. |
| 94 | S&F suitable size GI box with modular plate and cover in front on surface or in recesses including providingand fixing 25A modular socket outlet and 25 A modular SP MCB \"C\" curve including connection ,painting etc as required |
| 95 | Supply and fixing in replacement of old MCCB VTPN distribution board double door vertical type made out of CRCA mild steel sheet surface with insulated material like polyester or with epoxy powder coating, suitable for MCCB of capacity 125 Amps. 25 KA as incommer 12 way 415 volts with 200 Amps rated busbar adjustable thermal 70% to 100%) and fixed magnetic setting type complete all as specified and directed |
| 96 | Supply and fixing in replacement of old MCCB VTPN distribution board double door vertical type made out of CRCA mild steel sheet surface with insulated material like polyester or with epoxy powder coating, suitable for MCCB of capacity 125 Amps, 25 KA as incommer 8 way 415 volts with 200 Amps rated busbar adjustable thermal 70% to 100%) and fixed magnetic setting type complete all as specified and directed |
| 97 | Supply and fixing SPN DB 12 ways with 200 amps rated busbar 230 volt double door complete all as specified and directed. |
| 98 | Supply and foxing SPN DB 8 ways with 200 amps rated busbar 230 volt double door complete all as specified and directed. |
| 99 | Supply and fixing amp rating 240V, 10KA \"C\" curve miniature circuit breaker (MCB) of following poles and current canying capacity in the MCB DB complete with connection testing and commissioning complete all as specified and directed . |
| 100 | MCB SP 6-32 A complete all as specified and directed . |
| 101 | MCB SP&N 32Amps complete all as specified and directed . |
| 102 | Supply and fix MCCB four pole 415 volts 50 Hzs 125 Amps with 25KA repturing capacity complete all as specified and directed |
| 103 | Wiring for circuit/submain wiring alongwith earth wire of FRLSPVC insulated copper conductor single core cable of size 4X16 sq mm + 2x16.0 Sq mm earth wire including suitable size of concealed PVC conduit and lugs/thimble with nuts, bollits and washers etc complete including cutting chases for conduit and sinking s for boxes and making good to wall and floor/ ceiling, taking down old unsvsubmain wiring complete all as specified and directed . |
| 104 | Wiring for circuit/submain wiring alongwith earth wire of FRLSPVC insulated copper conductor, single core cable of size 4X10 sq mm+2X10 Sq mm earth wire including suitable size of concealed PVC conduit and lugs/thimble with nuts bollits and washers etc complete, including cutting chases for conduit and sinking.s for boxes and making good to wall and floor/ ceiling , taking down old unsvsubmain wiring complete all as specified and directed . |
| 105 | Wiring for circuit/submain wiring alongwith earth wire of FRLS PVC insulated copper conductor, single core cable of size 2X10 sq mm+1X10. Sq mm earth wire including suitable size of concealed PVC conduit and lugs/thimble with nuts, bolits and washers etc complete, including cutting chases for conduit and sinking,s for boxes and making good to wall and floor/ ceiling , taking down old unsvsubmain wiring complete all as specified and directed . |
| 106 | Wiring for circuit/submain wiring alongwith earth wire of FRLSPVC insulated copper conductor, single core cable of size 2X4 sq mm + 1X4 Sq mm earth wire including suitable size of concealed PVC conduit and lugs/thimble with nuts bolits and washers etc complete including cutting chases for conduit and sinking,s for boxes and making good to wall and floor/ ceiling, taking down old unsvsubmain wiringcomplete all as specified and directed . |
| 107 | Taking down care fully, deposited in MES store yard and refixingafter completion of repair work theLED lights fitting any type and any wattage/shape and size to its original position complete in all respect including connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed . |
| 108 | M&L Taking down of ceiling fan of 1200/1400 mm sweep size rewinding with the existing wire gauge, replacing bearing, bushes and painting with two coats of white/existing paint and marking the MES number complete all as specified and directed. |
| 109 | M&L Taking down of exhaust fan of any type/size rewinding with the existing wire gauge, replacing bearing. bushes and painting with two coats of white/existing paint and marking the MES number complete all as specified and directed. |
| 110 | M&L for Earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6 mm thick buried directly in ground (earth pit not less than 2.5 metres deep below normal ground level) with top edge of plate not less than 1.5 meters below normal ground level, connecting to the Galvanised iron earth wire4 mm size, by means of bolts, nuts, check nuts and washers of galvanised iron and 4mm earth wire protected by provision of GI medium grade pipe 40 mm bore upto test point including provision of concrete pit in PCC (1:2:4) type B-1 using 20 mm graded stone aggregates with 40 mm thick cover of RCC (1:2:4) reinforced with XPM (weigth not loss than 4 Kg/Sqm) and frame of angle iron 25x25x6 mm with lugs 02 Nos and with 6mm dia MS bar handle made to shape, GI light grade 20mmbore pipe for watering perforated at bottom 1.75 mtr long placed on top edge of earth plate, common salt and charcoal filling, test point made out of 40mmx8mmFI with fixing arrangement ,funnel, wire mesh and excavation/earth work in hard dence soil, returning filling in and removal of surplus soil to a distance not exceednig 50 metre, all as per Electric Plate No 3 of SSR 2010 Part-I and connecting to earth test point, complete all as specified and directed . |
| 111 | Earth continuity conductor or main earthing lead fixed to wall or batten or chases or burried in ground or any other Indicated situation for loop earthing as required 4 mm dia Gl wire complete all as specified and directed . |
| 112 | M&L for taking out window type AC of capacity 1.5/2 Ton of invertor/ nonivertor type or any modal and make at site, after disconnecting all electrical connection from multi-story buildingand re-installationServicing, cleaning (Dry and Wet), including gas charging R-22/R-32 refrigrant gas charging, inspection and testing of Split type Air condineer of capacity 2/1.5 Ton of invertor/ nonivertor type or any modal and make at sitecoatingin proper alignment/balancing andtightening of new GI nuts, bolts and washers alongwith anti-vibration pad complete all as specified and directed. |
| 113 | S&F PVC insulated and PVC sheathed stranded copper conductor flexible cable FRLS, 3 core, 2.5 Sqmm,1100 Volt grade complete all as specified and directed . |
| 114 | S&F in replacement energy efficient LED light fitting surface mounted 4\" long, 20 watt, 240 volts, 50 hz made out of extrunded aluminium housing with acrylic diffuser, LM 80 certified LED, costant current out put of electronic driver of operating voltage 140v to 270v and temperature - 10 degree centigrade to 50degree centigrade with ingress protection IP 20 duly pre wired with insulated copper wire, PF>0.80 with efficiency 120 lumins/watt and TDH less than 10%, CRI > 80 degree , CCT 6500 K in and including connecting up with twin core copper flexible cable of suitable size upto ceiling rose complete all as specified and directed. |
| 115 | S&F in replacement ofLED recess mounted Octane panel square/round type with Slim, compact, aluminium die cast edge lit panel. Recess mounted square fixture with opal diffuser and separate electronic driver. 230 volt, 50 Hz, 12 watt, 3000Kincludingand twin core 1.5 sqmm flexible copper cable for connecting to ceiling rose, including necessary alteration work in false ceiling to cover the blank space in false ceilingcomplete all as specified and directed . |
| 116 | S&F in replecement energy efficient LED light fitting, slim LED panel, recessed mounting 2 ftx 2 ft made out of power coated CRCA sheet with acrylic diffuser, constant current output of electronic driver operating voltage range of 150 to 270 volts AC, PF>0.80, high powder LEDs having efficiency of 100-120 lumins/watts, junction temparature less than 85 degree C and TH less than 12 % and CCT 6500K,, CRI>80 suitable for 36 watt LED, LM 80 certified LM, pri wired in and including connecting up with twin core copper flexible cable of suitable size upto ceiling rose /connector etc and testing complete all as specified and directed. |
| 117 | S&FLED mirror lightfitting 10watt,incluingcomplete and including twin core 1.5 sqmm flexible copper cable for connecting to ceiling rose complete all as specified and directed . |
| 118 | S&F in replecement energy efficient LED light fitting, slim LED panel, surface mounting 2\"x2\" made out of power coated CRCA sheet with acrylic diffuser, constant current output of electronic driver operating voltage range of 150 to 270 volts AC, PF>0.80, high powder LEDs having efficiency of 100-120 lumins/watts, junction temparature less than 85 degree C and TH less than 12 % and CCT 6500K, CRI>80 suitable for 36 watt LED, LM 80 certified LM, pri wired in and including connecting up with twin core copper flexible cable of suitable size upto ceiling rose /connector etc and testing complete all as specified and directed. |
| 119 | S&F D-linkCAT 6 I/O keystone Jack + 1 Box +1 Dual port face plate (combo set ) interface cardcomplete all as specified and directed . |
| 120 | DLP U PVCtrunking system Plastic adoptable type 150x50mm with two compartment duly covered installed with suitablesupport joints including all accessories such as end cap, changeable flat angle, changeable internal/external angle complete all .including taking down of existing unserviceable complete all as specified and directed . |
| 121 | M&L Rigid non-metallic PVC conduit exclusive of boxes (junction/terminal) but inclusive of all tees, bendselbows, reducers, bellmouth tube ends andfixing accessoriessuch as couplers, locknuts, sddles,pipe hooks etc. including taking down old pvc conduit complete all as specified and directed . , |
| 122 | Supply and fixing in replacement of Aluminium strip (lightning conductor) of 25 x 3. 15mm size on roof top/Water tank/parapit wall with the help poroceline insulator not more than 1 mtr apart, after completion of roof treatment complete all as specified and directed . |
| 123 | Supply and fixing inreplacement of Gl strip (taking down conductor) of 32 x 6mm size on roof top/wall as down conductor from parapit wall G+5 storey bldg (25 mtr length of GIstrip) to earthing test point with the help poroceline insulator not more than 1 mtr apart, after completion of roof treatment complete all as specified and directed . |
| 124 | S&F in replacement of Air Terminationsingle pointed Aluminium Rod 12mm dia 300mm long complete with fixing rivets, nut bolts and washer complete all as specified and directed. |
| 125 | M&L in replacement of Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw complete all as specified and directed. |
| 126 | M&L in replacement of earthing complete with galvanized steel earth plate electrode of size 60cm x 60 cmX 6.0 mm buried in the ground to a depth not less than 2.25 mtr below ground level connected to GI 32 x 6 mm strip by means of Gl nut, bolts, washers and check nut including GI Pipe pipe 40mm dia medium grade for earth strip protection pipe complete as shown in electric plate No 03 of SSR Part-I including 20 mm dia Gi pipe medium grade for watering, unnel and PCC of 1.3:6 type C1 pit cover with RCC (1:2.4) cover of size 30cm x 30cm x 40mm with one handle for lifting made out of 8mm dia MS bar including charcoal and salt in alternative layers including all earth work for excavation and removal of surplus soil and Testing Point complete all as specified and directed. |
| 127 | S&F in replacement of Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or burried in ground or drawn in conduit/pipe or any other indicated situation for loop earthing etc as required 32x6 mm galvanised iron strip complete all as specified and directed. |
| 128 | S&F in replacement of Aviation Obstraction Light LED lamp 50Hz, 240Watt Die-cast aluminum housing with Red polycarbonate enclosure dome for better illumination and Supper flux 5mm 302nos LEDs incorporated complete all as specified and directed . |
| 129 | M&L for in replacement of wiring for circuit/submain wiring along with earth wire with the 2 X 2 sqmm+ 1X 2.5 sq mm earth wire of FRLSH PVC insulated multistranded copper conductor single core cable in and including conduit pipe 25 mm external dia medium grade including all accessories complete all as required or complete all as specified and directed . |
| 130 | Supply and fix in replacement of MCB SP 230 volts 50 Hz, 16 Amps, with rupturing capacity 10 KA with Single pole & neutral DB 2 way for aviation obstruction light complete all as specified and directed . |
| 131 | Supply and fixing in replacement of GI Pipe 40 mm bore light grade 1.5 mtr long to be fixed on roof with 300 X 300 X 300 mm PCC 1:3:6 type C1, 20 mm graded aggregate block for fixing of air termination aluminium rod complete all as specified and directed . |
| 132 | M&L for taking down of existing rusted/unsv aluminium/GI strip of size 25 x 3. 15mm/32 x 6mm including rusted/unsv Air Termination and rusted/unsv Test point complete all as specified and directed . |
| 133 | M&L for taking down of existing rusted/unsv galvanized steel earth plate electrode of any size complete all as specified and directed . |
| 134 | M&L for taking down of existing rusted/unsvLED lamp of any size complete all as specified and directed . |
| 135 | M&L for taking down of existing rusted/unsv wiring of size upto 2.5 sqmm incuding MCBs complete all as specified and directed . |
| 136 | M&L for taking down of existing rusted/unsv GI Pipe of size upto 40mm complete all as specified and directed . |
| 137 | Supply, installation, testing and commissioning of 2 loop Microprocessor basedintelligent andmodular Fire Alarm Panel, 100% electronically addressable system where field device addressing is done by panel and not user, 7 inch LED touch screen Display, system with peer to peer networking of 126 network nodes, loop capacity of 220 devices per loop, built in charger that can support backup upto 24hours idle condition and 30 minutes during alarm condition, capacity to have upto 250 logic zones created, 4 NAC circuits, Event history on 9999 logs, capacity to communicate loop mount repeater panels, optional NAC power supply units that are loop mountable and 100% supervised from main panel in and including disconnecting & taking out old u/s panel any type complete all as specified and directed. |
| 138 | Supply, Installation, testing and commissioning of VDS/EN54approved repeater panel capable enough to program panels, mute, evacuate, silence & reset options on panel. Repeater Panel should be with built in battery in and including disconnecting & taking out old u/s panel any type complete all as specified and directed . Make- Honeywell Eaton Note- Including taking down old unserviceable complete all as specified & directed |
| 139 | Supply, installation, testing and commissioning of Addressable 2 wire Multi-Criteria Detector ( Photoelectric Smoke + Heat detection with in buit -in short circuit isolator), Chamber monitoring by panel, option to connect remote indicator. Detector should be provided with Base. Certification: EN54 Approved in and including disconnecting & taking out old u/s detector any type complete all as specified and directed. Note: Including taking down of detector andE/M fixuer/ fittings andwire connection from Wall, Ceiling/POP/ Roof surface. And refixing ,Repair /POP/ Ceiling and making good surfaceIncluding white wash /colour wash of the existing surface, rate to be deemed in quoted rate. |
| 140 | Supply, Installation, testing and commissioning of Addressable 2 wire Multimode Thermal heat detector with built-in short circuit isolator, 3 operating temperature of detector selectable from panel, 100% soft addressing, single LED that covers 360Deg lightpipe technology with intensity, Discreet design for incorporation into any décor, Common mounting base, Drift compensation, Removable detector chamber, Chamber monitoring by panel, option to connect remote indicator. Certification: EN54 Approved in and including disconnecting & taking out old u/s detector any type complete all as specified and directed.or equivalent.Note: Including taking down of detector andE/M fixuer/ fittings and wire, connection from Wall, Ceiling/POP/ Roof surface. And refixing ,Repair /POP/ Ceiling and making good surface Including white wash /colour wash of the existing surface, rate to be deemed in quoted rate. |
| 141 | Supply, fixing and laying XLPE, insulated& PVC sheathed armoured cable 1100volts grade, 1.5sqmm, 2 core with multistraded copper conductor insulated Extruded PVC type ST2 FR-LSH inner seathe galvanised round wire armour (0.9mm) including sadle clamp, screw all items and cable passing through wall, flooring and ceiling complete all as specified and directed . Note: Including taking down of E/M fixture/wire connection from Ceiling/POP/ Roof surface. And Repair /POP/ Ceiling and making good surface Including white wash /colour wash of the existing surface, rate to be deemed in quoted rate |
| 142 | Supply, fixing and laying XLPE, insulated& PVC sheathed armoured cable 1100volts grade, 1.5sqmm, 4 core with multistraded copper conductor insulated Extruded PVC type ST2 FR-LSH inner seathe galvanised round wire armour (0.9mm) including sadle clamp, screw all items and cable passing through wall, flooring and ceiling complete all as specified and directed . Note: Including taking down of E/M fixture/wire connection from Ceiling/POP/ Roof surface. And Repair /POP/ Ceiling and making good surface Including white wash /colour wash of the existing surface, rate to be deemed in quoted rate |
| 143 | Supply, Installation, testing and commissioning of Addressable 2 wire break glass manual call point with built in short circuit isolator, 100% soft addressed from panel, Wall mounting, resettable key option with back box. complete all as specified and directed . |
| 144 | Supply, Installation, testing and commissioning of Addressable loop powered Wall mount sounder with strobe, 100% soft addressed from panel, Low volume: 87dB at < 8.6mA & High volume: 100dB at < 11mA, shall be with inbuilt isolator. Note-including taking down of old unserviceable and making good surface Including white wash /colour wash of the existing surface, rate to be deemed in quoted rate |
| 145 | Supply and fix Fire Alarm sounders/ Sirens electronic type horizontal two stage continuous normal operation for at least 50 minutes with sound level 65 db to 120 db measured at 1.5 KM with sound output variation of +5 db 1000 mtr range. complete all as specified and directed . Note-including taking down of old unserviceable and making good surface Including white wash /colour wash of the existing surface, rate to be deemed in quoted rate |
| 146 | Supply, installation, testing and commissioning of Addressable 2 Wire Controlmodule, 100% soft addressed, integral short circuit isolators, SPDT relay contact to drive sounders load upto 1Amps at 30VDC temperature, Non latching changeover relay contacts, used as output module forshutting down AHU’s, and magnetic fire door holders.Elevator recall, fire damper, pressurization fan, speakers, strobes etc.The devicie shall be with inbuilt isolator.complete all as specified and directed . Note: Including taking down of detector andE/M fixuer/ fittings and connection from Ceiling/POP/ Roof surface. And refixing ,Repair /POP/ Ceiling and making good surface Including white wash /colour wash of the existing surface, rate to be deemed in quoted rate. |
| 147 | Supply, Installation, testing and commissioning of responce indicator discreet design for incorporation in to any décor. complete all as specified and directed . |
| 148 | Supply, Installation, testing and commissioning1KVA internal battery online UPS for fire alarm panel. complete all as specified and directed . |
| 149 | M&L in replacement for fixing in replacement of steel conduit of size 20mm on wall/ ceiling with clamps ,screw and complete all as specified and directed . |
| 150 | M&L in replacement for fixing in replacement flexibleof steel conduit of size 25mm on wall/ ceiling with clamps, screw and all connected items complete all as specified and directed . Note For item no 132 to 145 -: Any civil work such as falls ceiling, POP, taking down and refixing / repairing work such as ceiling, POP, cement plaster, white/colour wash and E&M fitting and fixture, wire connection, taking downand refixing as same on site, rate to be deemed in quoted rate. |
| 151 | P.A SystemSupply,Installation,Testing & Commissioning of wall mounting Speaker with talk back complete all as specified and directed |
| 152 | Supply, installation, testing and commissioning of Single button microphone. *Capsule Type:Condenser, *Polar Pattern:Cardioid, *Frequency Response:40-16KHz, *Mic Sensitivity:-43dB±2dB, *Prelude Sensitivity:-50db±2dB, *Power Supply:DC 9V complete all as specified and directed . |
| 153 | Supply,installation,testing and commissioning of Remote Paging Microphone, 12 zone capacity with 12 keypad buttons, each system can connection up to 32 remote microphone, DC24V power supply complete all as specified and directed . |
| 154 | Supply, installation, testing & commissioning of 120W Amplifier complete all as specified and directed . |
| 155 | Supply,installation,testing and commissioning of 8 Zone Router, built-in 500W class-D amplifier, with 8 zone speaker outputs and volume control, receive sources and fire alarm message from master controller, with AB speaker line low impedance supervision, with amplifier auto changeover into standby when fault, with extension amplifier connector, AC and DC battery operation complete all as specified and directed. |
| 156 | Exit SignagesSupply, Installation, testing and commissioning of EN54/BIS approved ceiling mounted Double Single Sided Signage with 30 mtr. viewing distance with built in High efficiency L80 LED with 50,000 hour life, Built in Ni-Cd battery with back-up of 3 hours, Housing of Polycarbonate, Glow wire test : 850°C, RAL9003, with set of 3 exit legends (L, R, D), Degree of protection IP42, Operation Mode Non -Maintained or Maintained mode selectable, Connection voltage 230V -/+ 5% [220V-240V] 50-60Hz SL2MNM, , Dimensions in mm:371 x 170 x 62 with IEC CB test certificate LED including necessary accessories as per specification complete all as specified and directed. |
| 157 | Supply & laying GI pipe light grade 25mm dia passing through wall, flooring and ceiling or drain complet all as specified and directed. |
| 158 | Supply and install Portable seamless steel Fire Extinguishers conforming and marked IS: 15683:2018 and 16018 duly wall with MS wall mounted bracket complete with pressure gauge/dischage EPDM rubber hose/discharge horn and any other accessories as per IS in and including initial filling of ABC dry chemical powder and pressurization of fire extinguisher with fresh/sufficient quantity/quality, ABC Dry chemical powder as per IS: 14609:1999and shall contain 90% Mono Ammonium Phosphate and pressurized with Nitrogen Gas complete all as specified and directed of 4Kg capacity cylinders. |
| 159 | Supply and install Portable seamless steel Fire Extinguishers conforming and marked IS: 15683 and 16018 duly wall with MS wall mounted bracket complete with pressure gauge/dischage EPDM rubber hose/discharge horn and any other accessories as per IS in and including initial filling ofCarbon dioxide (CO2) as per IS: 15222:2002 with minimum gas purity shall be 99.5 %complete all as specified and directed of 4.5Kg capacity cylinders. |
| 160 | M&L for Cement concrete in surface channels and drainsType C21:3:6complete all as specified and directed |
| 161 | M&L for in replacement of C class heavy duty MS pipe 150 mm dia by testing & commissioning (Wall thickness 63mm) conforming to IS 3589/IS 1239 including welding, fittings like elbows, tees, flanges, tappers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required complete all as specified and directed. |
| 162 | M&L for inreplacement of C class heavy duty MS pipe 200 mm dia by testing & commissioning(Wall thickness 6.3mm) conforming to IS 3589/15 1239 including welding, fittings like elbows, tees, flanges, tappers, nuts bolts, gaskets etc and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required complete all as specified and directed. |
| 163 | S&F for inreplacement of single headed internal hydrant valve with instantaneous stainless steel coupling of 63mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type A) with blank Stainless steel cap and chain as required complete all as specified and directed. |
| 164 | M&L for Hose box made of 18 gauge MS Sheet 800mm X 600mm X 250mm with double door with 4 mm thick glass door frame made of 16 gauge MS sheet duly painted fire red out side and brilliant white inside yard including taking out old unserviceable complete all as specified and directed. |
| 165 | S&F in replacement of 63 mm dia instantaneous pattern SS (Stainless Steel) Short branch pipe. 20 mm dia nozzle conforming to IS 903 suitable for inter connection to hose pipe coupling complete all as specified & directed |
| 166 | S&F in replacement of Non-percolating rubber reinforced lined fire hose pipe (as per IS 636) Type A of 63 mm dia and length as described below The hose shall be rated for burst pressure of 35 7 Kg/Sqcm Hose shall be complete with ISI marked SS male & female coupling (IS 903) bound & riveted to hose pipe with aluminum rivets $15 mm Gl wire (For Internal Hydrant & External Hydrant) complete all as specified & directed |
| 167 | S&F in replacement of Cast Iron Air Valves with two air Outlets, conforming to IS 14845 of size 100 mm dia bore and fixing up in Cast Iron Water supply mains of size 100 mm dia complete all as specified & directed |
| 168 | S&F for in replacement of non-retum valve 100mm dia by testing & commissioning of following sizes confirming to IS: 5312 complete with rubber gasket GI bolts, nuts, washers etc as required complete all as specified and directed. |
| 169 | All as per item No 163.00 here-in-before but of 150 mm dia. |
| 170 | S&F for in replacement of double flanged sluice valve 80mm dia by testing & commissioning of rating PN 1.6 with nor rising spindle bronze/gun metal seat. ISI marked complete with nuts, bolts, washers, gaskets and conforming to IS 780 of following sizes as required complete all as specified and directed. |
| 171 | S&F for in replacement of double flanged sluice valve 100mm dia by testing & commissioning of rating PN 1.6 with nan rising spindle, bronze/gun metal seat, ISI marked complete with nuts, bolls, washers, gaskets and conforming to IS 780 of following sizes as required complete all as specified and directed. |
| 172 | S&F for in replacement of double flanged sluice valve 150mm diaby testing & commissioning of rating PN 16 with non rising spindle, bronze/gun metal seat, ISI marked complete with nuts, bolts, washers, gaskets and conforming to IS 780 of following sizes as required complete all as specified and directed. |
| 173 | S&F for in replacement of first aid hose reel 40m with MS construction spray painted in post office red conforming to 884 complete with the following as required: 20mm nominal intenal dia water hose thermoplastic (Textile reinforced) type-2 as per 15 12585 20mm nominal intenal dia gun metal globe valve & nozzle Drum and brackets for foxing the equipment’s on wall. Connections from riser with 25mm dia stop gun metal valve and MS pipe and socket complete all as specified and directed. |
| 174 | S&F for in replacement of fire brigade connection 2 way 100mm dia MS pipe of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required complete all as specified and directed. |
| 175 | S&F in replacement of old unserviceable Pressure gauge 4” dial 0-14Kgs rating complete all as specified & directed. |
| 176 | S&F air vessel made of 250mm dia, 8mm thick MS sheet. 1200mm in height with air release valve on top and flanged connection to riser drain arrangement with 25 mm dia gun metal wheel valve with required accessories. pressure gauge and painting with synthetic enamel paint of approved shade as required complete all as specified and directed. |
| 177 | M&L for preparation of new steel surfaces over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. |
| 178 | Excavation in trenches in soft/loose so not exceeding 1.5 Mtr wide and not exceeding 1.5 Mt in depth and getting out complete all as specified and directed. |
| 179 | A as per them No. 173 here-in-before above but in hard/dense soil/ cutting of road/ hard standing breaking of PCC etc complete all as specified and directed. |
| 180 | Returning, filling in and including spreading levelling, watering and well ramming in layers not exceeding 25cmthick to achieve desiredcompactness complete all as specified & directed. |
| 181 | Removing surplus excavated materials to a distance n. exe 50 m and depositing where directed at a level n. exc 1.5 m above the starting point complete all as specified & directed. |
| 182 | M&L for PCC (1:24) Type B-1 using 20 mm graded machine crushed stone aggregate and finished the surface even and smooth without using extra cement as on brick complete all as specified and directed. |
| 183 | M&L for Removing excavated material exc. 1.50 km but n exc. 5 km and depositing where directed complete all as specified and directed |
| 184 | Repair of LT Indoor type panel, platform mounted, of size 1500mmx1500mmx500mm suitable for 415 Volts 3 Phase and neutral 4 wire 50Hz AC supply system having bus bar chamber with insulated electrolytic Aluminium bus bars TPN of capacity 400 Amps rating installed on DMC insulators with bus bar chamber The panel shall be dust and vermin proof, and made out of 2.00 mm thick CRCA mild steel sheet and mild steel & Mounting Channel frame work made out of angle iron of size 75 mmX5 mm), front opening type with aprons for cable entry, with proper ferrule & cable gland internal wiring with PVC insulated multistranded copper conductor FRLS cable of adequate size but not less than 1.5 sqmm complete. All steel metal works including frame shall be with anticorrosive coating with seven tank process and finally epoxy polyester powder coating of Siemens grey RAL-7035 shade The scope of work also comprising of the following-BUS BAR CHAMBER: -(a) 400 Amp 3 Strips & Neutral strip 400 Amp Aluminium conductor with color coded heat shrinkable sleave and shall be mounted on non-hygroscope, non-combustible, track resistant, high strength DMC material interconnection of all incomings & outgoings.INSTRUMENT CHAMBER: -(a) Digital Volt Meter 96X96mm flush type rated 1-500 V with Volt meter selector switch-01 Set.b) Digital Amp Meter 96X96mm, flush type rate 0-250 A with Amp meter Selector switch. 01 Set.(c) C.T’s 250/5 A CL 1.0 Tape Wound- 01 Set (Set of three).d) Red, Yellow, Green Phase indicating Lights LED type 220 V AC- 1 Set. (Set of three).(e) Protection MCB 6 A SP C Senes-1 Set (Set of three).INCOMING SUPPLY: -(A) MCCB 250 Amps 35 KA, 4 Pole with Fixed thermal & magnetic release 415 volts: 50Hz-01 No. |
| 185 | OUTGOINGS: -Star Delta Starter upto 50 HP Each having the following-2 Nos (Main Pump)(a) MCCB 125 A 25 KA 3 Pole Thermal Magnetic 01 No(b) Contactor 70 A TP (Main & Delta) 02 Nos(c) Contactor 50 A TP (Star) 01 No.(d) B1 Metal Over Load relay 30-50 A - 01 No.(e) Star delta timer Micon Series- 01 No.(f) Digital Amp Meter (0-100A)- 01 No.(g) CT 100/5A - 01 No.(h) Single Phase Preventer- 01 No.(i) Push button Start/Stop with Elements - 02 Nos.(j) On Off Top indicating Lights LED type 220 V AC-1 Set (Set of three).(k) Aux. Blocks 1 No + 1 No - 1 Set.Star Delta Starter 7.5 HP Each having the following 1 No. (Jockey Pump)(a) MCB 32 A 10 KA 3 Pole C Curve 01 No(b) Contactor 18 ATP (Main & Delta) - 02 Nos(c) Contactor 12 ATP (Star) 01 No.(d) B1 Metal Over Load relay 6-10 A-01 No(e) Star delta timer Micon Series 01 No(f) Digital Amp Meter (0-30A) - 01 No(g) CT 30/5 A-01 No.(h) Single Phase Preventer - 01 No.(i) Push button Start/Stop with Elements - 02 Nos(j) On, Off, Trip indicating Lights LED type 220 V AC-1 Set (Set of three)(k) Aux. Blocks 1 No + 1 No - 1 Set. |
| 186 | Notes: -1. Provison for Auto/Manual Mode incase of Auto failure2. Control circuit for Pressure Maintain via Pressure Switch\"\"The panel manufacturer shall have following Govt. Approved Certificates: 1. CPRI Certification Degree of Protection IP-54 (should have IEC 60439-1 test)2 CPRI Short Circuit withstand strenght should be 50k Arms for 10 Sec with intial peak of 105kA3. CPRI Certification Rated current for short circuit not less than 4000 A with rated insulation voltage 660V4. ISO 9001 CERTIFIED5. The contractor shall be submit detailed drawing of panel with showing all fittings and accessones for approval of GE (1) R&D Delhi before procurement. The rates for civil work ie brick work PCC & earth work is also descrived to be including in quoted rates.\" |
| 187 | (A) Repair of Electric driven Main Fire Pump suitable for automatic operation and consisting of following complete in all respects as required(B) Horizontal type multistage centrifugal, split casing pump of cast Iron body & bronze impeller with stainless steel shaft mechanical seal conforming to IS 1520.(C) 15 HP Squirrel cage induction motor, TEFC synchronousspeed 1500 RPM suilable for operation on 415 volts, 3 phase 50 Hz AC supply with IP 55 protection for enclosure, horizontal foot mounted type with Class-Finsulation, conforming to IS-325 .(D) MS fabricated Common base plate coupling coupling guard foundation bolts etc. as required.(E) Suitable cement concrete foundation duly plastered with anti vibration pads 1620 ipm at 56 m Head. |
| 188 | (A) Repair of diesel engine 16BHP driven main fire pump suitable for automatic operation and consisting of following. complete in all respects, as required (Diesel Driven Pump).(B) Horizontal type, multistage, centrifugal pump of cast of iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520.(C) 16 BHP 1500 RPM water cooled with radiator diesel engine conforming to relevant IS standard complete with auto starting mechanism, 12/24 volts electric starting equipment, diesel tank, exhaust pipe extended upto 10 m outside pump house duly insulated with 50 mm thick glass wool with 10 mm thick aluminium sheet cladding. residential silencer, instruments and protection as per standard specification, stop solenoid for auto stop in the event of fault with audio indications, painted with post office red colour etc as required.(D) MS fabricated, common base plate, coupling, coupling guard foundation bolts etc as required.(E) Suitable cement concrete foundation duly plastered and with anti vibration pads 1620 Ipm at 56 m Head. |
| 189 | (A) Repair of electric driven pressurisation pump suitable for automatic operation and consisting of following. complete in all respects, as required: (Jockey Pump).(B) Horizontal type, multistage, centrifugal pump of cast iron body and bronze impeller with stainless steel shaft mechanical seal conforming to IS 1520.(C) 7.5 HP squirell cage induction motor TEFC type suitable for protection for enclosure, horizontal foot mounted type with Class-F operation on 415 volts, 3 phase 50 Hz AC supply with IP 55 class of insulation, conforming to IS:325.(D) M S fabricated Common base plate, coupling, coupling guard. foundation bolts etc as required.(E) Suitable cement concrete foundation duly plastered and with anti vibration pads 300 Ipm at 56 m Head. |
| 190 | M&L for taking down of existing rusted/unsv MS pipe 150 mm dia including , fittings like elbows, tees, flanges, tappers, nuts bolts, gaskets etc complete all as specified and directed. |
| 191 | M&L for taking down of existing rusted/unsv MS pipe 200 mm dia including , fittings like elbows, tees, flanges, tappers, nuts bolts, gaskets etc complete all as specified and directed. |
| 192 | M&L for taking down of existing unsv single headed internal hydrant valve with instantaneous stainless steel coupling of 63mm dia with cast iron wheel complete all as specified and directed. |
| 193 | M&L for taking down of existing unsvnon-retum valve 100mm dia complete all as specified and directed. |
| 194 | M&L for taking down of existing unsvnon-retum valve 150mm dia complete all as specified and directed. |
| 195 | M&L for taking down of existing unsv sluice valve 80mm dia complete all as specified and directed. |
| 196 | M&L for taking down of existing unsv sluice valve 100mm dia complete all as specified and directed. |
| 197 | M&L for taking down of existing unsv sluice valve 150mm dia complete all as specified and directed. |
| 198 | M&L for taking down of existing unsv first aid hose reel 40m complete all as specified and directed. |
| 199 | M&L for taking down of existing unsv fire brigade connection 2 way 100mm dia MS pipe of cast iron body complete all as specified and directed. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy