| 1 | Taking up Cast iron/Mild steel water mains (including all fittings), with spigot and socket ends and tyton joints/lead joints including burning out joints and recovering lead for the following sizes complete all as specified and directed. |
| 2 | 80 mm bore |
| 3 | 100 mmbore |
| 4 | 150 mm bore |
| 5 | 150 mm bore flange type |
| 6 | Supply and lay in trenches in replacement of Ductile iron pipes K-9 Spigot and Socketed ends, centrifugally cast suitable for tyton joint in different lengths including rubber tyton joint complete as per site condition of following sizes all as specified and directed. |
| 7 | 80 mm bore k-7 |
| 8 | 100 mm bore k-7 |
| 9 | 150 mm Bore K-7 |
| 10 | 150 mm Bore K-9 |
| 11 | DI double flanged pipe 150 mm K-9 |
| 12 | Supply and laying, jointing and testing MS Pipe heavy grade class C including welding required work of all fittings such as bend, tee, elbow, union, reducer,flange etc, laid in trenches or wall/ceiling/floor as specified and as directed at site of the following sizes :- (Notes : (i)The laying and jointing of pipes are required to be carried out in short streches catering to specific requirements of a purticular quarter, building block or a group of blocks.) |
| 13 | 80 mm bore |
| 14 | 100/125 mm bore |
| 15 | 150 mm bore |
| 16 | M&L for DI Fittings like bends (any type, radius, and angle) tapers any type straight bend, increasing, decreasing or double socket Etc) Tee pieces single branch, Y junction, double branch cross all socket or socket and spigot) collars, cops, upto 150 mm bore of pipe complete all as specified and directed. |
| 17 | M & L for \"D\" joints complete with nut bolt & washers etc suitable for the following sizes of water mains |
| 18 | 80mm bore |
| 19 | 100mm bore |
| 20 | 150mm bore |
| 21 | Labour only for cutting of cast iron water mains of following sizes carefully in repairs for inserting fittings such as bend, tee, socket pieces, collar etc complete all as specified and as directed. |
| 22 | 80mm bore |
| 23 | 100mm bore |
| 24 | 150mm bore |
| 25 | M&L for drilling / boring and tapping cast iron water mains (in position) for branch connections of the internal dia 20 mm complete all as specified and direted. |
| 26 | M&L for Straight plain brass ferrules (or connecting screws ) screwed both ends and fixed to CI pipes pipes of size 20 mm bore |
| 27 | Supply & Fix gun metal gate valve with iron wheel head screwed both end for iron pipe complete all as specified of the following sizes including dismantling the old unserviceable existing valve complete. |
| 28 | 15mm bore |
| 29 | 20 mm bore |
| 30 | 25 mm bore |
| 31 | 40mm bore |
| 32 | Taking out unserviceable sluice valve including S & F sluice valve, class PN-1.6, heavy duty, both ends flangedwith gun metal spindle & check nut and all nuts, bolts, washers, gaskets etc; including dismantling of old unserviceable sluice valve complete of the following sizes (Note :- for these sluice valves which are fixed with pillar of over head tank work involve such as breaking of PCC/Lead flange joints will be deemed to include in the rate quoted & contractor will also repair the damaged floor etc,to match with existing. ( joints shall be measured & paid for seprately). |
| 33 | 80 mm bore |
| 34 | 100/125 mm bore |
| 35 | 150 mm bore |
| 36 | Taking out unserviceable Non return valve supply andfixing connecting and testing non return valve horizental flow both and flanged class \"B\" as per IS specification and conforming to IS -5312 including flange joints etc for the following sizes Make : Zoloto CodeNo-84813000, or equivalent Kalpana / BIR / Kirlosker / Leader |
| 37 | 80 mm bore |
| 38 | 100 mm bore |
| 39 | 150 mm bore |
| 40 | Excavation in trenches not exc. 1.5mtr wide and not exe 1.5 mtr in depth forlaying GI pipe/ CI Pipe etc. and getting out in soft/loose soil complete all as specified and directed. |
| 41 | Returning fillingin soil from excavation including spreading, leveling, watering and well ramming in layers n.exe. 25 cm thickcomplete all as specified and directed. |
| 42 | Removing excavated (surplus soil) to a distance not exc. 50 m and depositing where directed at a level not exc. 1.5m above the starting point complete all as specified and directed. |
| 43 | M&L for construction of brick masonry valve chamber of internal size 1.05 x 1.05x 1.05 Mtr (Internal dimension) with sub class \"B\" bricks in CM (1:6) with 3mm thick MS Sheet cover and angle iron frame made out of 40x40x6mm with 2 Nos MS hinges welded to angle iron frame including lifting hook & locking arrangement duly painted with one coat of black bituminous paint over a coat of red oxide primer complete with necessary earth work, brick work, PCC bed, cement plastering, finishing including dismantling and removal of old unserviceble valve pit remains from site complete all as specified and directed. |
| 44 | all as per item no 15 but for 900 mm x 900 mm x 900 mm (Internal dimension) |
| 45 | Cutting of road/dismantling of any interlocking paver blocks from pathways making good as existing disturbed surface all rates are included complete all as specified and directed. |
| 46 | M&L for PCC 1:2:4 type B1 using 20 mm stone aggregate for providing, cement concrete in roof kerbs or mud stops, rounded or chamfered on edges in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string course lacing courses, parapets and railing upto 60cm in height copings, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, slightly rounded orchamfered angles and throating complete all as directed |
| 47 | M&L for brickwork with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius built in complete all as specified and directed |
| 48 | M&L for rendering 10 mm thick on fair face of brick work in CM 1:6 finished even and smooth without using extra cement complete all as specified and directed. |
| 49 | S&F bib taps 15 mm bore, Bib taps, cast iron with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed, complete all as specified and directed. |
| 50 | S&F bib taps 20 mm bore, Bib taps, cast iron with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed, complete all as specified and directed. |
| 51 | S&F in replacement of PVC NRV for chamical doging pump as per site requirement all as specified and directed. |
| 52 | Taking out steel tubing from from trenches/or from any site all as directed by Engineer-in-Charge for the following sizes complete all as specified and directed (excavation & earth work shall be measured and paid separetly) |
| 53 | 15mm bore |
| 54 | 20 mm bore |
| 55 | 25 mm bore |
| 56 | 40 mm bore |
| 57 | 50 mm bore |
| 58 | 80 mm bore |
| 59 | Supply and laying, jointing and testing GI Pipe medium grade including supply and fixing of all fittings such as bend, tee, elbow, union, reducer etc, laid in trenches or wall/ceiling/floor as specified and as directed at site of the following sizes :-(Notes : (i)The laying and jointing of pipes are required to be carried out in short streches catering to specific requirements of a purticular quarter, building block or a group of blocks.) |
| 60 | 15mm bore |
| 61 | 20 mm bore |
| 62 | 25 mm bore |
| 63 | 40 mm bore |
| 64 | 50 mm bore |
| 65 | 80 mm bore |
| 66 | Re-laying, jointing old steel tubing after cleaning and connections in new or old position including supply & Fix new fittings such as bends, elbows, union, tees, reducers etc; as required at site laid in trenches or on floors complete all as specified and as directed of the following sizes :- |
| 67 | 15mm bore |
| 68 | 20 mm bore |
| 69 | 25 mm bore |
| 70 | 40 mm bore |
| 71 | 50 mm bore |
| 72 | 80 mm bore |
| 73 | Supply and fixing Float / Ball valves high pressure of PTMT with epoxy coated Aluminium rod& high density plastic ball screwed for iron pipe complete all as specified and directed. |
| 74 | 15mm bore |
| 75 | 20 mm bore |
| 76 | 25 mm bore |
| 77 | Taking out, sluice valve top cover, spindle and broken / unsv check nut (gutka)carry to workshop & re-fixing ofsluice valve after servicing /maintenance /grinding / cleaning / threading / greasingwork to sluice valve parts, including replacement of gland packing, rubber sheet, nut, bolt, Spindle ,check nut and washer of existing size complete all as specified and directed, of following size:- |
| 78 | 80 mm dia bore |
| 79 | 100mm dia bore |
| 80 | 150mm dia bore |
| 81 | 200 mm dia bore |
| 82 | M&L for repairing leakages of CI pipes with spigot and socket ends, de-watering of pipe lines and trenches, burning out joints to recover lead and making new lead joint with retrieved material and any additional quantity of lead required as per site requirement complete including all other materials such as spun yarn, fire woodetc and testing complete all as specified of the following sizes (Excavation and earth work shall be measured and paid seperately):- |
| 83 | 80 mm dia bore |
| 84 | 100mm dia bore |
| 85 | 150mm dia bore |
| 86 | M&L for dismantling of non clog cetifugal sewage pump/motor of sewage installation of any capacity for cleaning and minor repair as required ,replacement of gland packing,nut bolt , greassing , leakage & clearblokage of suction pipe,cleaning of NRVand torepairduring not lifting water/mud from the sump any type of complaint related sewage complete all as specified and directed.Note :-The controctor will ensure availability of manpower equipped with all sort of petty items such as gland packing, nut bolt, gress etc required to accomplish the job. The controctor will also ensure as availability of every type of requisite T & Pand Mobile phone to his trade man. T&P and safty equipment to his Plumber & helper to prevent any type of accidents and department will not responsible to provide any type of compensation tothe contractor or his labour in case of any type of accidents / miss-happening or any type of casualty to his labour / plumber for any type of work. |
| 87 | Day to day maintaince / repair / rectifiction of any type of water supply complaints like No water Supply or building mounted PVC OHT or any size and any type by digging along with the length upto 01 mter of water pipe line and in any type of soil upto the bottom of pipe to locate the exact pin point location of fault including rectification of fault with the help of plumber, returning filling of same by tightening and including replacing of GI union, elbows, sockets, tees, nipple, check nuts barrel nipple or cast iron special and fittings etc ofany size and type as and when required complete all as specified and directed by Engineer-in-Charge. Note: (i) Exacavation shall measured & paid separately under relevant items of this schedule. (ii) The all fitings like GI union, elbows, sockets, tees, nipple, check nuts barrel nipple, reducer any type and any size required to replace up to 80 mm shall deemed to above coated rates not measured & paid seperately iii) Contractor is fully responsible to provide necessary, transportaion, T&P and safty equipment to his Plumber & helper to prevent any type of accidents and department will not responsible to provide any type of compensation tothe contractor or his labour in case of any type of accidents / miss-happening or any type of casualty to his labour / plumber. |