Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Surface excavation in soft/loose soil not exceeding 30cm deep and averageing 15cm deep and getting out complete all as specified and directed. |
| 2 | Excavating in trenches not exceeding 1.5 m wide and not exceeding 1.5 m depth for foundation etc or for shafts wells cespits, manholes, pier holes etc not exceeding 10 sqm on plan and not exceeding 1.5 m in depth and gettingout in soft/loose soil complete all as specified and directed. |
| 3 | Returning filling in layers including leveling watering and well ramming in layers not exceeding 25 cm thick compelte all as specified and directed. |
| 4 | Removing surplus spoil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed. |
| 5 | M&L PCC 1:4:8, type D-2 (using 40 mm graded stone aggregate ) as in foundation filling, sub base for floors etc complete all as specified. |
| 6 | M&L Brick work with sub class \"B\" old size bricks straight or curved on plan exceeding 6m mean radius built in cement mortar 1:6 complete all as specified and directed. |
| 7 | M&L Brickwork with sub- class ‘B’ bricks, straight or curved on plan to any radius in half brick thick walls built incement mortar 1:4 complete all as specified and directed. |
| 8 | Use & waste of formwork to sides of concrete foundations,footings,bases or column,raft and raft beams,sides and soffits if any of foundations and plinth beams and similar work,vertical or batter etc rough finished surface of concrete complete all as specified and directed. |
| 9 | Use & waste of formwork to sides of pillars,posts,struts,piers,columns and stanchions ect fair finished surfaces of concrete complete all as specified and directed. |
| 10 | Use & waste of formwork to sides and soffits of floor or roof beams, beams haunchings, girders, bressummers, lintels, cantilever, shelves including supports, overhangs, etc also splays between floors and beams etc rough finished surfaces of concrete all as specified and directed. |
| 11 | Use & waste of formwork tosoffits of suspended slabs such as roof slabs, floor slabs landings and similar work not exceeding 200mm thick (Horizontal or sloping) complete all as specified and directed. |
| 12 | Use & waste of formwork to edges of concrete flats, treads breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exceeding 10 cm but not exceeding 20 cm wide complete all as specified and directed. |
| 13 | M&L RCC (1:1.5:3), type B1 (using 20mm graded stone aggregate) as in foundations including rafts,footings,foundations beams ,bases of column etc complete all as specified and directed. |
| 14 | M&L RCC (1:1.5:3), type B1(using 20mm graded stone aggregate) as in columns,pillers,piers,posts and structs etc complete all as specified and directed. |
| 15 | M&L RCC (1:1.5:3), type B1 (using 20mm graded stone aggregate) as in beams,cantilevers,bressummers,lintels over 1.5 m span complete all as specified and directed. |
| 16 | M&L TMT bars 10 mm dia and over, cut to length bent to shape required including cranking bending spirally for hooping for columns hooking ends and binding with and including mild steel wire (annealed ) not less than 0.9 mm dia complete all as specified and directed. |
| 17 | All as per Srl Item No16 here-in-before but 5 mm dia and over upto and including 10 mm dia in stirrups spaces and binders. |
| 18 | Taking downcementplasterany description on brick or stone walls, /RCC walls surfaces etc. including raking out joints, hacking for key, scrubbing down with water, etc complete all as specified and directed. |
| 19 | M&L 15mm thick cement plaster in cement mortar 1:4 on brick or concrete surface finished even and fair withoutusing extra cementall as specified |
| 20 | M&L 10mm thick cement plaster in cement mortar 1:6 on brick or concrete surface finished even and smooth without using extra cementall as specified and directed. |
| 21 | M&L Rendering 5mm thick in cement mortar (1:3) oninceiling, soffits of chajja or similar location any face of brick walls or conrete surfaces, surfaces finished even and smooth without using extra cement etc complete all as specified and directed. |
| 22 | M&L hard core of gauge not exceeidng 63 mm deposited spread and levelled in layers not exceeding 15 cm thick watered and ramed to a true surface complete all as specified and directed. |
| 23 | M&L 50mm thick PCC(1:2:4), type B-1 (using 20mm graded stone aggregate) as in flooring complete all as specified and directed. |
| 24 | M&L 25mm thick PCC (1:2:4), type B1 (using 20 mm graded stone aggrigate)as in floor finished even and rough to receive top layer complete all as specified and directed. |
| 25 | M&L non - skid Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour over and including a screed layer of 15 mm thick in cementmortar 1:6 complete all as specified and as directed. |
| 26 | M&L non skid coloured ceramic tiles of7 to 8 mm thick, area of each tile exceeding 0.11 sq m but not exceeding 0.18Sq m as in skerting/dadoset and jointed in neat cement slurry and pointed in white cementmixed with colour pigment to match andincluding backing with 10 mm thick in cementmortar 1:4 complete all as specified and as directed. |
| 27 | M&L 450mm X 350mm & 7mm thick glazed coloured(Digital colour) ceramic tiles on vertical surface of such as skirting, dados and risers to stepsetc.,including 10mm thick rendering in cementmortar 1:4 on brick or concrete surface finished rough to received dado/ skirting, set and jointed in neat cement slurry and pointed in white/coloured cement to match the shadewith cement mortar bedding and removing off the premises complete all as specified and directed. |
| 28 | S&F Factory made box type steel window with pintle hinges & 2 Nos 150mm mild steel tower bolts to each shutter, steel handle and with glazing bars dovetailed or welded and with one shop coat of zinc chromate primer complete all as specified and directed. |
| 29 | S&F Factory made box type steel window with pintol hinges & 2 Nos 150mm mild steel tower bolts to each shutter, steel handle and without glazing bars dovetailed or welded and with one shop coat of zinc chromate primer complete all as specified and directed. |
| 30 | S&F Factory made box type steel ventilator with glazing bars dovetailed or welded and with one shop coat of zinc chromate primer complete all as specified and directed. |
| 31 | M&L framed work such as grills etc with ends of bars shouldered and or riveted or forged into spike; framed guard bars and similar work conforming to Fe 410-0 0r Fe 310-0 complete all as specified and directed. |
| 32 | S&F Solid PVC door frame of size 50 mm x 47 mm made of 5 mm plain colour PVC sheet reinforced with mild steel square tube complete all as specified in clause 8B.3.1 and shown on page 150 of MES Schedule Part-II (2010) complete all as specified and directed. |
| 33 | S&F Pressed steel frames made of 1.25mm thick MS sheet of profile 105mmx60mm for door and window frames with one rebate including lock strike plate, shock absorber, 20mm dia 60mm long MS conduit for housing of a drop bolt, treating of internal surfaces of chowkhats with coal tar or black paint including hinges, hold fasts/lugs etc complete all as specified and directed. |
| 34 | All as per Srl Item No 33here-in-before but size 125mmx60mm with double rebate. |
| 35 | M&L cement concrete (1:3:6), type C-1 (using 20mm graded stone aggregate) as in filling of steel chowkhats,bed blocks, coping etcincluding necessary form work complete all as specified and directed. |
| 36 | S&F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of MS tubes for top & bottom rails, MS frame covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; paneling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading and jointed together with solvent cement, supply and fixing in the frame at site as per clause 8 B.2.1 of MES schedule Part-II (2004) complete all as specified. Make: Rajshri or equivalent in approved makes. |
| 37 | S&F plain framed panel shutter 30 mm thick second class hard wood (any number of panels ) with panel of timber flat on both side (featherd egde )or veneered particle board medium density wood particle board with commercial face veneers suplied and fitted to chowkhats complete all as specified and directed. |
| 38 | S&F 35mm thick second class hard wood glazed and skelton shutters,open rebated and prepared to receive glass gauze,etc (without sash bars),edges of framingplain chamfered or rounded fitted with cut and mitred beads for securing glass etc sizes of members of shutters as specified in SSR part-I section 8 clause 8.24(a) fitted to chowkat complete all as specified and directed. |
| 39 | M&L Preparation of new steel surfaces of any description, over 10cm width or girth and applying two coats of synthetic enamel paint over red oxide zink primer on steel surfaces complete all as specified. |
| 40 | M&L Preparation of new wooden or wood based surfaces of any description, over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed. |
| 41 | M&L Preparation of old wooden or wood based surfaces of any description, over 10cm width or girth and applying one coats of synthetic enamel paint complete all as specified and directed. |
| 42 | S&F Pre-painted galvatume aluminium zince coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed. |
| 43 | S&F Pre-painted galvatume aluminium zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550Mpa as in roof covering/cladding to wall,fixed with self tapping screws complete all as specified and directed. |
| 44 | S&F Roof trusses (framed), trussed,purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. of Fe 410-W (Gde E-250) Quality \"A\" including fabrication, erraction and fixing complete all as specified and directed. |
| 45 | S&F Rolled sections as in post/pilllars where connected with angle cleats or other connecting plates etc,of Fe 410-W(Gde E-250) Quality \"B\" including fabrication,erection and fixing complete all as specified and directed. |
| 46 | S&F Mild steel plates(plain or chequered) channels,square cut or notched(ordinary and counter sunk) forming holes,without any attachment and fixing complete all as specified and directed. |
| 47 | S&F PTMT tower bolts, 200 mm long and fixed with steel screws complete all as specified and directed. |
| 48 | S&F PTMT butt hinge, 100mm long,fixed with steel screws with brass/bronze hinge pin complete all as specified and directed. |
| 49 | S&F PTMT handle 125mm long fixed with steel screws complete all as specified and directed. |
| 50 | S&F 200mm long aluminium, anodisedbarrel tower bolts of extruded section, complete all as specified and directed. |
| 51 | S&F 150mm Extruded aluminium alloy handlecomplete all as specified and directed. |
| 52 | S&FAluminium alloy, anodised, sliding door bolt 300mm length,with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified and directed. |
| 53 | S&F mild steel 300 mm, ordinary rat tail rod pattern springs, including roller and roller plate complete all as specified and directed. |
| 54 | S&F 3 mm thick sheet glass, ordinary quality and glazing with oil putty in squares not exceeding 0.50 Sqm each pane complete with oil putty complete all as specified and directed. |
| 55 | S&F stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel staple etc complete all as specified and directed. |
| 56 | S&F in repairs brass chromium plated bib tap for iron pipe of 15mm borefancy type with crutch or butterfly handle, screwed down high pressure complete all as specified and directed. |
| 57 | S&F in repairs brass chromium plated long body bib tap for iron pipe of 15mm borefancy type with crutch or butterfly handle, screwed down high pressure complete all as specified and directed. |
| 58 | S&F in repairs chromium plated cast copper alloy 1-way angle cock with flange suitable for 15mm bore pipe, complete all as specified and directed. |
| 59 | S&Fwall mixer with \"L\" bend (Provision for OH shower) 15mm for mixing hot & cold water screwed down for iron pipe and fixed complete all as specified and directed. |
| 60 | S&F in repairs CP brass shower rose 150mm size shower with 300mm arm suitable for 15mm bore pipe complete all as specified and directed.Makes : Prayag cat No. BS-79S or or techno-commercially equivalent in approved makes. |
| 61 | S&F in repairs looking mirror 600mmx450mmwith aluminium channel frame, selected quality mounted on 6mm thick commercial ply wood back and fixed with chromium plated brass screws and cup washers complete all as specified and directed. |
| 62 | S&F CP soap dish, any type, fixed to plugs with chromium plated brass screws complete all as specified and directed. |
| 63 | S&F in repairs PVC connection 450mm long with 2 Nos brass check nuts suitable for 15mm bore of pipe with washerccomplete all as specified and directed. |
| 64 | S&F in repair PVC low level flushing cistern (white) of 10 liters capacity with inlet ball float valve, PVC flush pipe and necessary fixing arrangements and connecting to water pipe and WC etc and fixed in repairs complete all as specified and directed. |
| 65 | S&F in repair Vitreous china white squatting pan orrissa pattern of size 630mm x 450 mm with integral foot rests including necessary cement concrete and 100 mm bore cast iron ‘P’ trap with 550 to 600 mm long neck for connecting WC to branch piece with cement joints, fixed as in repair, complete all as specified and directed.. |
| 66 | S&F Vitreous china white wash down water closet (pedestal pattern) including PVC seat cover and connection to drain or out going pipe and to flushing pipe anti-syphonage pipe etc, complete all as specified and directed. |
| 67 | S&F in repairs,Ist quality vitreous china wash hand basin, white flat back size 550mmx400mm (excluding taps, waste, pipe chain and plug) but including porcelain stopper and a pair of MS bracket etccomplete all as specified and directed. |
| 68 | S&F 32mm waste fittings, brass, chromium plated for glazed ware sinks, basins, etc. with long screwed shanks and fly-nuts, flange end bedded in red lead cement and other end fixed complete all as specified and directed. |
| 69 | S&F PVC waste pipe of standard pattern, not less than 75cm long , 32/40mm dia for steel sink waste coupling or urinalof suitable size complete all as specified and directed. |
| 70 | S&F galvanised steel tubing, medium grade, with all fitting and fixed to walls, ceilings or laid in floors 15 mm dia including taking up or down old steel tubingcomplete all as specified and directed. |
| 71 | S&F galvanised steel tubing, medium grade, with all fitting and fixed to walls, ceilings or laid in floors 20 mm dia including taking up or down old steel tubingcomplete all as specified and directed. |
| 72 | M&L 100mm thick cement concrete (1:4:8), type D-2 (using 40mm graded stone aggregate) as in subbase of interlocking complete all as specified and directed. |
| 73 | M&L in repair for precast machine pressed cement concrete interlocking paver blocks of any shape and size confirming to IS 15658-2006 of 60 mm thick M-35 grade, glossy type with grey cement and pigment laid dry over a layer of 25 mm thick sand cushioning complete all as specified and directed.Note:-sand cushioning to be measured and paid for seperately. |
| 74 | M&L sand filling under floors, foundation or cable protection including spreding leveling in layer not exceeding 25cm thick complete all as specified and directed. |
| 75 | M&L PCC 1:2:4, type B-1 (using 20m graded stone aggregates) as in kerbs, rounded or chamfered on edges complete all as specified and directed. |
| 76 | M&L cement concrete 1:3:6, type C2 (using 40 mm graded stone aggregate) as in concrete bed to drain pipe 150 mm dia including packing under and haunching against the sides of pipe after they are laid and tested completed all as specified and directed. |
| 77 | S&F salt glazed stonewire drain pipe 150 mm internal diameter grade \"A\" laid in trenches jointed and tested complete all as specified and directed. |
| 78 | M&L cutting into existing manholes for connecting new drains 150mm dia,making good to pipe & rendering,cutting out existing benching for & forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 smooth finished & reforming benching as required complete all as specified and directed. |
| 79 | S&F in rep of Gypsum Board 6 to 7 mm thick in ceiling fixed with screw 60cmx60cm placed in ceiling (Angle 25mm X 25mm, Main tee 38mmX23mm ,Sub tee 23mmX23mm) incl aluminium anodised/powder coated snap grid frame 605mmX605mm for false ceiling incl hanging arrangement complete all as specified and directed.Note:-The hanging stay wire shall not be less than 4.00mm thick and quoted rate shall deemed inclusive of rate of stay wire as per site requirements. |
| 80 | S&F in repair Gun-metal, globe or gate valves, with iron wheel head, screwed both end for iron pipe and fixed 20 mm dia complete all as specified and directed. |
| 81 | S&F in repair Gun-metal, globe or gate valves, with iron wheel head, screwed both end for iron pipe and fixed 25 mm dia complete all as specified and directed. |
| 82 | M&L color rotational molded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I capacity of the tank 1000 ltrs including GI tank nipple of size 20/15 mm dia including dismantling of old water tank complete all as specified and directed. |
| 83 | M&L color rotational molded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I capacity of the tank 500 ltrs including GI tank nipple of size 20/15 mm dia including dismantling of old water tank complete all as specified and directed. |
| 84 | S&F ball valves of 20 mm bore high pressure of PTMT with epoxy coated Aluminium rod & high-density plastic bal screwed for iron pipe and fixedcomplete all as specified and directed. |
| 85 | Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories) complete all as specified and directed. |
| 86 | S&F PVC (SWR) junction 100mm bore single, (Single T) equal or unequal all as specified and directed. |
| 87 | S&F 75 mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls or laid in trenches complete all as specified and directed. |
| 88 | S&F 110 mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls or laid in trenches ccomplete all as specified and directed. |
| 89 | S&F 75mm dia PVC (SWR) bends any radius complete all as specified and directed. |
| 90 | S&F 110 mm dia PVC (SWR) bends any radius complete all as specified and directed. |
| 91 | S&F 75 mm dia PVC (SWR) bends any radius with access door complete all as specified and directed. |
| 92 | S&F 110 mm dia PVC (SWR) bends any radius with access door complete all as specified and directed. |
| 93 | S&F 75 mm dia PVC (SWR) vent cowl complete all as specified and directed. |
| 94 | S&F 110 mm dia PVC (SWR) vent cowl complete all as specified and directed. |
| 95 | S&F cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint complete all as specified and directed. |
| 96 | S&F PVC (SWR) multi floor trap with grating including jointing with solvent cement 75/100 mm dia outlet complete all as specified and directed. |
| 97 | S&F in repair PVC (SWR) gully trap 125/110 mm, setting and jointing with solvent cementcomplete all as specified and directed. |
| 98 | Demolition of unreinforced cement concretein ground floors and paving n.exc 15 cm thickness below or above ground level complete all as specified & as directed. |
| 99 | M&L75mm thick PCC 1:3:6, type C-1 (using 40/20mm graded stone aggregate) as inlevelling course to receive floor finishes, etc complete all as specified and directed. |
| 100 | M&L 75 mm thick cement concrete 1:3:6, type C-2 (using 20mm graded stone aggregate) as in plinth protection, shall be laid in 1:20 slope. The concrete shall be laid at a stretch not exceeding 3-meter in length. Joint gap between the adjoining slab, at corners and at junctions of wall shall not exceed 10mm in width and shall be sealed with mastic filling i.e. one part of bitumen of grade 85/25 garde mixed with 3 part of sand. Top surface of concrete shall be finished even and smooth without using extra cement. Joints shall be provided at not more than 3-meter interval at corner and junction walls complete all as specified and directed. |
| 101 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles and rubbish off the premises complete all as specified and directed. |
| 102 | S&F granite (of any type) stone slab of20mm thick laid over 15mm thick cement screed bed in cementmortar 1:6 machine cut,size and jointed over grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing complete all as specified and directed. |
| 103 | Dismantling of stone slabs and tiles of any description or thickness in floors aprons laid bedded and pointed in any mortar complete all as specified and directed. |
| 104 | Taking down chowkhat with shutter exceeding 1.50 Sqm and not exceeding 4 Sqm (without taking off shutter) each complete all as specified and directed. |
| 105 | Taking down chowkhat or frames exceeding 1.50 Sqm and not exceeding 4 Sqm each complete all as specified and directed. |
| 106 | Taking down shutters of exceeding 1sqm but not exceeding 2 Sqm each complete all as specified and directed. |
| 107 | M&L Preparation of new plastered surfaces wall and applying two coats of Oil bound distember over a coat of primer and applying a coat of 1mm thick wall care puttycomplete all as specified and directed. |
| 108 | M&L Preparation of new plastered surfaces and applying two coats of cement base paint over a coat of alkali resistant priming paint complete all as specified and directed. |
| 109 | M&L Preparation of new plastered surfaces and applying three coatswhite washing on ceiling surfaces complete all as specified and directed. |
| 110 | M&L white washing one coats on ceiling including preparation of old plastered surfaces complete all as specified and directed. |
| 111 | M&L complete removal of oldexisting treatment on walls, cornices etc by brooming down or steel wire brushing scrapping down smoke soot moulds, moss and efflorescence salt and trading oil decorated surface of walls and applying a coat of wall care putty of approved make as on wall surface and two coats of oil based distemper (white or tinted) complete all as specified and directed. |
| 112 | M&L complete removal of oldexisting surfaceand applying two coats cement based paint over one coat of alkali resistant priming paint completecomplete all as specified and directed. |
| 113 | Dismantling brick work built in cement mortar of any specification and in any position complete all as specified and directed. |
| 114 | All as per Srl Item No 6 here-in-before but using old bricks retrieved from item No 113 demolition including cleaning and removal of mortar from old bricks. |
| 115 | S&Fin repair mild steel curtain rod powder coated with fixing side brackets, end cup, rings @10 Nos per running metre and fixed with PVC rawl plugs & steel screwscomplete all as specified and directed. |
| 116 | Demolition of existing RCC chhajja or similar article including cutting of steel reinforcement , making good disturbed portion with concreting or plastering whatever required, mixing with bonding agent (Pedelite/Sika/Fosrock).Note:- Size of Chajja is not more than 2.00 Sqm and of 0.15cm thick. |
| 117 | M&L rolled sections as in main and cross beams/columns, hip and jack rafters, purlins where connected to common rafters and running rails and guides for sliding doors, fixed with angle cleats or other connecting plates (Fe-410 W Gde E-250 Quality A) complete all as specified and directed. |
| 118 | M&L cutting chases, pinning in, making good to facings in brick work where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc. and making good, cutting not exceeding 10 cm girth all as specified complete all as specified and directed. |
| 119 | M&L cutting holes exceeding 400 Sqcm but not exceeding 0.10 Sqm into or through brick walls built in cement mortar complete all as specified and directed. |
| 120 | M&L PCC 1:2:4, type B-0 (using 12.5mm graded stone aggregate) as inlevelling course to receive floor finishes, filling of eaves gap, sides of interlocking tiles,filling of pressed steel chowkhats, etc complete all as specified and directed. |
| 121 | S&F Repair/Refixing of 4mm thick designer cement fiber ceiling board of size 600mmx600mm in ceiling fixed with screws laid on hot dipped galvanised iron imposed grid with 24mm wide T-section exposed flanges which shall be powder coated in white colour. . Hangers of G.I. wire max 4mm dia to be fixed by the approved rowl plug, level adjusters and screws etc. The last hanger at the end of each main runner shall not be greater than 450 mm from adjacent wall flush fitting of 1200mm long cross tee with(double stitching) to be interlocked between main runner at 600mm centre to from 1200mmx600mm modules cross T longer than 600mm modules to be formed by fitting 600mm long cross T, T preremeter wall angle shall be of 0.45mm thick galvanised steel of size 19mmx19mm of powder cated white colour all as per instruction including taking off old ceiling board of any size complete all as specified and directed. |
| 122 | S&F Providing and fixing 4mm thick designer cement fiber ceiling board of size 600mmx600mm in ceiling fixed with screws as per manufacturer\"s instructions (Make : Everest & M/s Visaka Industries Ltd or equivalant in approved makes) laid on hot dipped galvanised iron imposed grid with 24mm wide T-section exposed flanges which shall be powder coated in white colour. The frame shall comprise of main runner made from 0.33mm thick galvanised steel sheet and size of 24x32mm and spaced at 12mm centres securely fixed to the structural soffits by approved hangers at 1200mm maximum at centres making a grid of size 600x600mm. Hangers of G.I. wire max 4mm dia to be fixed by the approved rowl plug, level adjusters and screws etc. The last hanger at the end of each main runner shall not be greater than 450 mm from adjacent wall flush fitting of 1200mm long cross tee with(double stitching) to be interlocked between main runner at 600mm centre to from 1200x600mm modules cross T longer than 600mm modules to be formed by fitting 600mm long cross T, T preremeter wall angle shall be of 0.45mm thick galvanised steel of size 19x19mm of powder cated white colour all as per instruction including taking off old ceiling board of any size complete all as specified and directed. |
| 123 | M&L machine cut kota stone slab flooring 18-20 mm thick over and including 15 mm thick cement screed (1:6) base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and granite polish complete all as specifed and directed complete all as specified and directed. |
| 124 | S&F 5mm thick coloured of any selected design hollow PVC wall cladding strips interlocked to each other fitted to wall including PVC \"U\" shapes of top/ bottom and PVC angles at door/windows openings all as per manufacturer\"s fixing instructions as in repair complete all as sepecified and directed. |
| 125 | M&L Point wiring complete with 1100 volts grade PVC insulated unsheathed FRLS cable of copperconductor, multi stranded of size 1.5 sqmm, single core,in and including rigid non-metallic PVC conealed conduit, with all accessories if require such as bends,reducers, spacers, saddles, junction boxes bakelite sheets, wooden rectangular boards / round blocks(for housing lamp holders and light fittings etc) and MS pressed steel / cast iron sunken boxes of suitable size for mounting switches / bell pushes / sockets, fan regulator etc covered with new 3 mm thick laminated bakelite sheet top cover including continuous earth wire of size 1.5 sqmm unsheated stranded copper conductor with green PVC insulation connected to common earth dolly complete all as specified and directed for the followings :- (a) One light/fan/Bell Pointcontrolled by one single pole one way switch. |
| 126 | (b) One socket outlet on the sameboard controlled by one single pole one way switch complete all as specified and directed. |
| 127 | (c) One 5 amps socket outlet independentcontrolled by one single pole 5 Amp switch. |
| 128 | Allas per ItemNo 125 here-in- before but one three pin 15 Amps switch socket out let on the independentboardwith 2.5 SqmmPVC insulated copper conductor and 2.5 Sqmm copper conductor for continuous earthing complete. |
| 129 | S&F Switch piano flushtype single pole one way5/6 Amp complete all as specified and directed. |
| 130 | S&F Switch piano flush type 15 amps, single pole one way duly ISI marked complete all as specified and directed. |
| 131 | S&F Socket outlet 2 in one , 5/6 Amps flush typeISI marked complete all as specified and directed. |
| 132 | S&FSocket outlet, 2 in one6pin 5 and 15 Ampspiano flush type ISI marked complete all as specified and directed. |
| 133 | S&F ceiling rose, PVC/Polycarbonate, isolated three terminals complete all as specified and directed. |
| 134 | S&F Lamp holder PVC/Polycarbonate,isolated with back plate suitable for batten fittings including 10W LED Bulb complete all as specified and directed. |
| 135 | S&F ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200mm sweep. Min air delivery 210 CFM with service value 6.00 BEE five star rated with brushless direct current motor (BLDC) complete all as specified and directed. |
| 136 | S&F in repair stepped type electronic fan regulater flush type on the existing phenolic laminated sheet etc complete all as specified and directed. |
| 137 | S&F LED tube light fitting 1X18 Wdecorative ultra slim linear LED lighting fixture with extruded polycarbonate, environmental friendly, energy efficient230V,complete with all accessories internally pre wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size.Makes:- Cat Part No LHEXBLP7UN1W018 of make \"Havells\"or techno-commercially equivalent in approved makes. |
| 138 | S&F sheet metal enclouser double door factory made powder coated out of CRCA mild steel sheet 1.2 mm thick wih metallic painting white series pre-wired SPN DBs, 240 volts 200 Amps rated bus bar,Neutral link,Earth bar andDin rail,8 way dust and vermin proof suitable for incorporation of MCBs duly concealed in wall and making good to distrubed surface and colour matching complete all as specified. |
| 139 | S&F 240V, 10 KA \"B\" curve miniature circuit breaker (MCB) of single poles and current carrying capacity 6 to 32 AMP, in the MCB DB complete with connection testing and commissioning complete all as specified and directed. |
| 140 | S&FMCB, Single Pole and neutral 240 V, 32 Amps 10 KA \"B\" series complete all as specified and directed. |
| 141 | S&F Sheet Metal Enclosures with Socket plug top and MCBs Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB, 20 Amp complete all as specified and directed. |
| 142 | S&F LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed. |
| 143 | M&L Earthing complete with galvanized steel plate elecrode of size60 cm x 60cm & 6.0 mm thick burried directly in ground vertically to a depth not less than 2.5 mtr below the ground level with top edge of earth plate at a depth not less than 1.5 mtr below ground level. Earth plate surrounded by 15mm thick packed alternative layers of charcoal dust and comman salt, earth lead GI wire of 4mm dia (8 SWG) by means of bolts , nuts, check nuts and washers of galvanised iron with thimbles. The other end of GI earth wire is connected to main switch board and protected by light grade GI pipe of 15 mm bore. provision of 20mm bore light grade GI pipe for watering including GI funnel and wire mesh. Pipe shall be provided vertically upto top level of earth pit and then taken horrizontally to the earth pit. Cement concrete chamber of PCC ( 1:3:6 ) type C-2 using 40 mm graded stone aggregate.The chamber shall be constructed one metre away from edge of earth pit. 50 mm thick pre cast cover of cement conrete (1:2:4) type B-1 using 20 mm graded stone aggregate,excavation in soft / loose soil, returning filling and removal of surplus soil to a distance of 50 mm as directed and shown in Electrical Plate No- 3 of SSR Part-1 (2009) complete all as specified and directed. |
| 144 | Supply and lay cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, electric power cables (Heavy duty) 1100 volts grade with stranded aluminium conductor of size 16 Sqmm 2 core complete all as specified and directed. |
| 145 | M&L Bricks common burnt clay building bricks, sub-class ‘B’ designation 75 laid dry width wise acrose the line of cable in trenches for protection of underground cable complete all as specified and directed. |
| 146 | S&F Mild steel galvanised iron pipe light grade (ISI marked) 40mm bore for passing of earth lead laid in trenches fixed to walls laid under floors, roads including all fittings i.e MS clamps nuts & bolts etc as required complete all as specified and directed. |
| 147 | S&F galvanised steel tubing, medium grade, with all fitting and fixed to walls, ceilings or laid in floors 40 mm dia including taking up or down old steel tubingcomplete all as specified and directed. |
| 148 | M&L cutting existing CI/GI pipe 40/50/80/100mm dia bore including run lead joints of suitbale size with necessary fillings complete all as specified and directed. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail