| 1 | Taking down existing water proofing treatment on the roof, cleaning with wire brush etc. and removing debris outside MD land all as specified and directed. |
| 2 | Demolition of un-reinforced concrete on roofs, floors (other than ground floors), beams/ chajjas and similar suspended work |
| 3 | M & L for Providing, cement concrete 1:3:6,type C-1 (20mm graded aggregates) in bed blocksincluding weathering, slightly rounded or chamfered angles and throating, all as specified and directed. |
| 4 | M &L for 40 mm thickPlain Cement Concrete Type B0 1:2:4 (using 12.5 mm graded aggregate) as in roofpadding / leveling coursekerbs,or chamfered on edgesfinished even and smooth without using extra cementand mixed with water proofing compound. ( Water proofing compound shall be measured and paid seprataly ) |
| 5 | M & L for 10mm thick Screed bed or bedding layer of cement mortar 1:3 for floor finishes and mixed with water proofing compound complete all as specified and directed.( Water proofing compound shall be measured and paid seprataly ) |
| 6 | Supply only liquid water proofing compound |
| 7 | M&L for providing 3 mm thick APP modified waterproofing membrane, weighing not less than 3.6 kg/sqm, reinforced with known woven polyester matt black finished weighing not less than 160g/sqm having softening point not less than 150 degree celcius longitudnal tensile strength not less than 300 N/5cm , 10 cm overlap and 15 cm for end laps , over a coat of bitumen primer @ of 0.20 kg/sqmand finising with bituminious aluminium paint applied @ 0.10 kg / sqm and finished all as as per manufactures instruction and as directed.Note:-The work shall be carried out by authorised appicator of manufacturer. |
| 8 | M & L for applying 3 coats of acrylic polymer based elastomeric coloured single component UV resistant liquid membrane (Dr Fixit New Coat or equivalant of Sika/Cico/STP) of about 1-1.5mm dry film thicknessover and including a coat of primer as per manufacturer\"s instructions over roof slab and taken up to 300mm high on wall etc, coving the prepared substrate at junctions of the terrace and parapet using polymer mortar to fill in the cracks opened up in V grooved all as specified and directed.Note :-1.Work will be carried out through manufacturer\"s applicators only.2.Coverage of material should not be less than 2 Sqm per litre per coat or as per manufacurers instructions. |
| 9 | M & L for preparing old wall/ceilling/roof surface which includes clean and free from oil or loose materials and applying two coats of \"\"Asian Smart Care Damp Block 2K\"\" two components acrylic polymer-modified cementitious high performance coating all as per manufacturer\"s instruction ans as directed. |
| 10 | M & L for preparation, cleaning of old APP membrane surfaces and applying one coat of bituminious aluminium paint applied @ 0.10 kg / sqm complete all as as per manufactures instruction and as directed. |
| 11 | Labour for Cutting grooves in brick wall, and shaping horizontal face of groove and making good with cement mortar 1:3 all as specified directed. |
| 12 | Taking up or down 15 mm bore steel tubing and connections, including cleaning for refixing or removal . |
| 13 | Taking up or down 20 mm bore steel tubing and connections, including cleaning for refixing or removal to store |
| 14 | S & F 20 mm bore galvanized Steel tubes, medium grade with all fittings forwater supply pipes etc., laid in trenches/fixed on walls. |
| 15 | Refixing 20mm bore of pipes old steel pipes and connection in new or old position (walls, ceiling, floors etc,) |
| 16 | S & F 15 mm bore galvanized Steel tubes, medium grade with all fittings forwater supply pipes etc., laid in trenches/fixed on walls. |
| 17 | Refixing 15 mm bore of pipes old steel pipes and connection in new or old position (walls, ceiling, floors etc,) |
| 18 | S & F in repairs20mm boregun metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed. |
| 19 | Disconnecting existing water tanks, setting aside (or lowering if required) for repairs, cleaning etc and hoisting if required reconnecting and re-fixing in position of size exc 500 ltr but n.exc 1000 ltr. |
| 20 | Dismantling water tank of exc 500 and nexc 1000 ltr.complete all as specified. |
| 21 | S&Fin repairs rotational moulded polyethylene water storage tanks three layer (cylindrical, vertical with closed top) of 1000 Ltrs capacity hoisted and fixed in position all as specified and directed |
| 22 | S&Fin repairs rotational moulded polyethylene water storage tanks three layer(cylindrical, vertical with closed top) of 500 Ltrs capacity hoisted and fixed in position all as specified and directed |
| 23 | S&F in repairs 20mm ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed min. wt 20mm-210gm Make \"Paryag/polytuf\" |
| 24 | S & F in repairs PVC tank cover for 500 /1000 Ltrs capacity complete. |
| 25 | Demolition of brickor stone/ boulder masonary, built in cement mortar complete all as specified |
| 26 | M&L Precast cement concretetype C1 1:3:6 (Using 20 mm gradedaggregate) block masonrywith solidblocks, exc. 10 cm in width and setting in mortar 1:6 complete all as specified and directed. |
| 27 | Taking down cement plasteron brick or stone walls, etc., including raking out joints, hacking for key, scrubbing down with water, etc. |
| 28 | M&L for rendering 15 mm thick in cement mortar 1:4 using intergral water proofing compound on fair face of brick/concrete surfaces and finished even and smooth without using extra cement all as directed. |
| 29 | M&L for rendering 15 mm thick in cement mortar 1:6 using intergral water proofing compound on fair face of brick/concrete surfaces and finished even and smooth without using extra cement all as directed. |
| 30 | M&L preparation of new decorated surfaces and applyingtwocoat of acrylicemulsion exterior gradeon wall over a coat of primer complete all as specified |
| 31 | M & L for preparation of old surfaces and applying one coat of acrylic emulsion exterior gradeon wall complete all as specified and as directed. |
| 32 | M&L preparation of new decorated surfaces and applyingtwocoat of distemperoil emulsion over 1 mmof putty finish and a coat of alkaline resistant primer complete all as specified |
| 33 | M & L for applying one coat of distemper oil emulsion on old decorated surfaces ofwalls including preparation of surface by washing, rubbing down and stopping of distempered surfaces all as specified and directed. |
| 34 | M & L forcomplete removal of existing treatment from old plastered surfaces of celing and applying two coats of distember oil over a coat of alkali resistant prime primer over and including 1 mm thickwall care putty with brush/roller, finished even and smooth complete all as per manufacturer\"s instruction and as directed. |
| 35 | Dismantling single layer mangalore pattern or similar tiles in roofing complete all as specified and as directed. |
| 36 | M&L Roof tiles, Mangalore pattern,interlocking at side joints, laid in cement mortar complete all as specified and as directed. |
| 37 | Except tiles roof tiles mangalore pattern, interlocking at side joints, laid dry complete all as specified and directed. |
| 38 | M & L for Ridge or hip tiles to suit Mangalore pattern of roofing tiles, bedded and jointed in lime mortar 1:3 or cement mortar 1:6 complete all as specified and as directed. |
| 39 | All as per item No. 38 here-in-before but exept tiles |
| 40 | Dismantling battens for tiles, shingles etc of any size including tilting fillets. |
| 41 | S&F for 2nd class hardwoodtile battens clean sawn witrh sectional area exc 15 sqcmbut n exc 25 sqcm at 30 cm centres complete all as specified and directed. |
| 42 | All as per item No. 41 here-in-before but except battens |
| 43 | Dismantling of unframedtimber scantlings 40 sq. cm and over in section, in any position tile battensas in roofing |
| 44 | S&F for 2nd class hard-woodscantlings clean sawn as in roof members complete all as specified and directed. |
| 45 | Dismantling boarding, any description, fixed in any position with screws. |
| 46 | S&F for 20mm thick 2nd class hard wood boarding, supplied and fixed with nails in any situation (except flooring and skirting) complete all as specified and directed. |
| 47 | M & L for preparation of new painted surfaces of wood and wood based materials of any description not other wise described over 10 cm width or girth and applying Two coat of synthetic enamel paint over a pink primer coat complete all as specified and directed. |
| 48 | M&L forPreparation of new/old untreated surfaces of magalore pattern tiles including brooming down or steel wire brushing applying one coat of tile guard exterior grade apex paint over acoat of primer all as specified and directed.Note :-Rate for painting upto 15 mtr height deemed to be included in quoted rate by the contractor |
| 49 | M & L for preparation of old painted surfaces of wood and wood based materials of any description not other wise described over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed. |
| 50 | M & L for preparation of old painted surfaces of steel and iron surfaces of any description not other wise described over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed. |
| 51 | Dismantling Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings |
| 52 | S&F for 0.63mm thick Galvanised, corrugated mild steel sheeting with two corrugations side lap, fixed with coach screws and washers, in roofs, walls etc with grade of zinc coating 275, all as specified and directed. |
| 53 | Except sheeting (any thickness) Galvanised, corrugated mild steel sheeting with two corrugations side lap, fixed with coach screws and washers, in roofs, walls etc with grade of zinc coating 275 all as specified and directed. |
| 54 | S&F in repairsfor pre-painted Galvalume aluminium Zinc cooating GI based corrugated steel sheet 0.5 mm thick of any colour having tensile strength of 550 mpa as in covering/cladding to wall fixed with self tapping screws all as specified and directed. |
| 55 | Except sheeting (any thickness) pre-painted Galvalume aluminium Zinc cooating GI based corrugated steel sheet 0.5 mm thick of any colour having tensile strength of 550 mpa as in roof covering/cladding to wall fixed with self tapping screws all as specified and directed. |
| 56 | S&F in repairs for pre-painted Galvalume aluminium Zinc cooating GI based Plain steel sheet 0.5 mm thick of any colour having tensile strength of 550 mpa as in covering/cladding to wall fixed with self tapping screws all as specified and directed. |
| 57 | Except sheeting (any thickness) pre-painted Galvalume aluminium Zinc cooating GI based Plain steel sheet 0.5 mm thick of any colour having tensile strength of 550 mpa as in roof covering/cladding to wall fixed with self tapping screws all as specified and directed. |
| 58 | S & F repairs Pre-painted galvalume zinc coating GI based corrugated steel sheet 0.50mm thick of any colour and in crimp for awining /roof covering/sunshades having tensile strength of 550 Mpa fixed with screw/hookes type complet all as specified. |
| 59 | Fixing only Pre-painted galvalume zinc coating GI based corrugated steel sheet 0.50mm thick of any colour and in crimp for awining /roof covering/sunshades having tensile strength of 550 Mpa fixed with screw/hookes type complet all as specified. |
| 60 | S & F repairs Pre-painted galvalume zinc coating GI based corrugated steel sheet 0.50mm thick of any colour and in circular /Arch shape as in roof covering/sunshades having tensile strength of 550 Mpa fixed with screw/hookes type complet all as specified. |
| 61 | Fixing only Pre-painted galvalume zinc coating GI based corrugated steel sheet 0.50mm thick of any colour and in circular /Arch shape as in roof covering/sunshades having tensile strength of 550 Mpa fixed with screw/hookes type complet all as specified. |
| 62 | S&F in repair For Fibre glass reinforced translucent semi-corrugated sheeting 2mm thick with two corrugations side lap fixed with coach screw and washer in roof, wall etc. |
| 63 | Dismantling Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings all as specified and directed. |
| 64 | S & F 3mm thick, solid embossed pattern polycarbonate sheet, colour as approved by GE as in roof,fixing with self tapping screw and joints of polycarbonate sheet shall be sealed with silicon with and including aluminium strip/ties etc required for fixingall as per manufacturers instructions and as directed. |
| 65 | Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to store (measured overall as fixed along the centre line overall as fixed along the centre line over fittings and accessories) Note :-Rate for fixing the gutter upto 10mtr height deemed to be included in quoated rate by the contractor. |
| 66 | S & F in repair PVC half rounded gutter dia 250 mm (CL-2) (6 kg/cmsq) all as specified and as directed.Note :-Rate for fixing the gutter upto 12 mtr height deemed to be included in quoated rate by the contractor. |
| 67 | Fixing Only PVC half rounded gutter dia 250mm (CL-2) (6 kg/cmsq)fixed with suitable MS brackets all as specified and as directed.Note :-Rate for fixing the gutter upto 12 mtr height deemed to be included in quoated rate by the contractor. |
| 68 | S & F in repair PVC half rounded gutter dia 160mm (CL-2) 0.4 Mpa (6 kg/cmsq)all as specified and as directed. |
| 69 | Fixing Only PVC half rounded gutter dia 160mm (CL-2) 0.4 Mpa (6 kg/cmsq)all as specified and as directed |
| 70 | S & F in repair PVC Pipe dia 160mm (CL-2) 0.4 Mpa (6 kg/cmsq) fixed with suitable MS brackets vertical surface of wall all as specified and as directed |
| 71 | Fixing Only PVC Pipe dia 160mm (CL-2) 0.4 Mpa (6 kg/cmsq) fixed with suitable MS brackets vertical surface of wall all as specified and as directed |
| 72 | S&F in repair PVC bends 160mm dia all as specified and as directed. |
| 73 | S&F in repair PVC bends 250mm dia all as specified and as directed. |
| 74 | S&F in repair 160mm dia PVC half rounded gutter(Single `T\") equal or unequalall as specified and as directed. |
| 75 | S&F in repair 160mm dia PVC endsall as specified and as directed. |
| 76 | S&F in repair 250mm dia PVC half rounded gutter(Single `T\") equal or unequalall as specified and as directed. |
| 77 | S&F in repair 250mm dia PVC endsall as specified and as directed. |
| 78 | S & F in repairs 110 mm bore PVC (SWR) Soil, waste and vent pipes single socketed in any length with rubber ring joints laid in floors or trenches/ walletc complete.(6 Kg/ cm Sq). |
| 79 | Except pipes for 110mm diaPVC (SWR) pipes single socketted, in any length with rubber ring joints, fixed to walls with suitable MS clamps complete all as specified and directed. |
| 80 | S & F in repairs 75 mm bore PVC (SWR) Soil, waste and vent pipes single socketed in any length with rubber ring joints laid in floors or trenches/ wall etc complete .(6 Kg/ cm Sq). |
| 81 | Except pipes for 75mm diaPVC (SWR) pipes single socketted, in any length with rubber ring joints, fixed to walls with suitable MS clamps complete all as specified and directed. |
| 82 | S&F in repair PVC (SWR )bends 110mm dia all as specified and as directed. |
| 83 | S&F in repair PVC (SWR )bends 75mm dia all as specified and as directed. |
| 84 | S&F in repairs 110 mm PVC (SWR) WC connector bent type all as specified and as directed. |
| 85 | S & F in repairs 110 mm bore PVC (SWR) bends of any radius with access doors all as specified and as directed. |
| 86 | S & F in repairs 75 mm bore PVC (SWR) bends of any radius with access doors all as specified and as directed. |
| 87 | Dismantling of structural steel work including door ,gates but excluding framed truss etc all as specified and as directed. |
| 88 | S & F Framed work such as grills, gratings, etc with ends of bars shouldered and/or riveted, or forged intospikes; framed guard bars; barred iron doors ladders framed balusters; walk ways railings ; framework of water tanks and similar work confroming to Fe 290. Gde-E165 all as specified and directed. |
| 89 | S&F Rolled mild steel works such as in main and cross beams, hip and jack rafters, purlins, angle cleats or other connecting plates, as in rain water gutter clamps etc. conforming to Fe-410-W(Gde E-250) quality-A |
| 90 | M&L steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I.S. 1161-1979 grade St.-240 all as specified. |
| 91 | M&L forPreparation ofnew/previously untreated steel surfaces of any description, over 10 cm width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer all as specified and as directed. |
| 92 | Dismantling wall and ceiling board (fibre,pulp,insulation etc.)or insulation board/slab/blanket any thickness including cover fillets all as specified and directed |
| 93 | M&Lfor gypsum board false ceiling 12mm thick fixed with standard GI frame work with GI furring channels of 16 gauge, main \"U\" shaped channels @ 1220mm C/c and inter connected cross channels \"C\" shape spaced at 610mm c/c,the main furring channels shall be fixed through GI channels suspenders from there of @1200c/c, Main and inter connected channels shall be fixed through fasteners clips as per manufacturer\"s instructions,shall be applied with two coats of plastic emulsion paint over a coat of primer all as specified and directed. |
| 94 | M&Lgypsum boardfalse ceiling 12mm thick as in repairs incld accesserioes shall be applied with two coats of plastic emulsion paint over a coat of primer all as specified and directed. |
| 95 | M&Lfor wall panelling gypsum board12mm thick as in repairs with including assesories andshall be applied with two coats of plastic emulsion paint over a coat of primer all as specified and directed. |
| 96 | S & F in repairs of plaster of paris decorative type cornices 120 to150 mmsize of any shape and design to be fixedall around at the junction of wall and ceiling etc andshall be applied with two coats of plastic emulsion paint over a coat of primer all as specified and directed. |
| 97 | Supply& fixing of Armstrong Mineral Fibre Suspended Ceiling System with Classic Lite Tegular Edge Tiles of 12mm thick and Armstrong Prelude 24mm face exposed grid. The tiles shall have pin hole visual with Humidity Resistance (RH) of 99%, 0.55 as per ASTM C423 standard, CAC of 36db, Light Reflectance ≥87%, Thermal Conductivity k = 0.052 - 0.057 W/mK, Colour Global White, Fire Performance of Class 0/1 as per BS 476 Part 6/7 and Class A as per ASTM E84with 16mmTegular edge. The tile shall be laid on Armstrong Prelude 32 with 24 mm wide T - section flanges colour global white (matching to tile colour) having roll formed double stroke rotary stitching on all T sections i.e. the Main Runner, 1200 mm & 600 mm Cross Tees with a web height of 32mm. The grid system is to comprise main runner spaced at 1200mm securely fixed to the structural soffit using Armstrong suspension system (specifications above) at 1200mm maximum. Flush fitting 1200mm long cross tees to be interlocked between main runners at 600mm to form 1200 x 600 mm module.Cut cross tees longer than 600mm require independent support. 600 x 600mm module to be formed by fitting 600mm long flush fitting cross tees centrally between the 1200 mm cross tees. Perimeter trim to be Armstrong wall angles of size 3000x19x19mm, secured to walls using screws at 450mm centre to centre maximum. |
| 98 | M&L for onlymodular false ceiling board 9mm thickof calciumsilicate material of size 595mm x 595mm GRG ceiling tiles shall have weight 7 Kg /Sqmall as specified and directed.Note :-Rate for fixing the ceilling upto 10mtr height deemed to be included in quoated rate by the contractor. Make: Armstrong/ Diamond/ Saint Gobain or equivalent. |
| 99 | S&F in repairs for Tensile fabric roofing preconstraint 702 S2-8604S Translucent white Blanco translucido made by approved make multilayer composite materialwith special densely wooven low wick yarns 1100 dtex PES HT anticapillary treated \"TERSUISSE\" standard in the base fabric of weight not less than 750gms/sqm confirming to ENN ISO 2286-2 of standerd width 250/267 cm with tensile strength 280/280 daN/5 cm confirming the EN ISO 1421 standerd and tear stength 30/28 daN confirming to DIN 53.363 with Adhesion 10/10 daN/5 cm confirming toEN ISO 2411 and finished with formula S2 fluorinated varnish weldable with light transmission 13.5 % in NFP 38511 including stretching fixing tying etc complete all as per specified and directed. |
| 100 | Fixing for Tensile fabric roofing preconstraint 702 S2-8604S Translucent white Blanco translucido made by approved make multilayer composite materialwith special densely wooven low wick yarns 1100 dtex PES HT anticapillary treated \"TERSUISSE\" standard in the base fabric of weight not less than 750gms/sqm confirming to ENN ISO 2286-2 of standerd width 250/267 cm with tensile strength 280/280 daN/5 cm confirming the EN ISO 1421 standerd and tear stength 30/28 daN confirming to DIN 53.363 with Adhesion 10/10 daN/5 cm confirming toEN ISO 2411 and finished with formula S2 fluorinated varnish weldable with light transmission 13.5 % in NFP 38511 including stretching fixing tying etc complete all as per specified and directed. |