| 1 | Engagement of Beldar |
| 2 | Providing and fixing double scaffolding system (cup lock type) on the exterior side, up to seven story height made with 40 mm dia M.S. tube 1.5 m centre to centre, horizontal & vertical tubes joining with cup & lock system with M.S. tubes, M.S. tube challies, M.S. clamps and M.S. staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it there after. The scaffolding system shall be stiffened with bracings, runners, connection with the building etc wherever required for inspectionof work at required locations with essential safety features for the workmen etc. complete as per directions and approval of Engineer-in-charge. The elevational area of the scaffolding shall be measured for payment purpose. The payment shall be made once irrespective of duration of scaffolding.Note: - This item to be used for maintenance work judicially, necessary deduction for scaffolding in the existing item to be done. |
| 3 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications :, Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/ 10 sqm of approved brand or manufacture |
| 4 | Applying priming coat :, With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/steel works |
| 5 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :, 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources). |
| 6 | Applying stamping finish to the top surface of freshly laid plain / reinforced cement concrete of specified grade in portico, side walks, drive ways, pool decks and open yard as per direction of the Engineer-in-Charge. * The concrete shall be placed and screened to the finished grade and floated to the uniform surface by using standard finishing techniques. approved color hardener @ 2.7 kg/sqm shall be applied evenly to the surface of the fresh concrete by the dry shake method by sprinkling in twoor more shakes floated after each shake and trowel only after final floating. The approved released agent @ 0.113 Kg/Sqm shall be applied evenly to the trowelled surface before stamping or the said release agent can be applied to the flexible polyurethene stamp moulds of approved design and in required sizes to achieve final stamping pattern. These stampings shall be placed on the surface of concrete in three to four pieces at a time and tapped gently with rammers of sufficient size and weight to leave proper stamp marks and the process repeated for the remaining concrete surface till the whole surface to be stamped is completed within the time while the concrete is in plastic stage of setting. * After stamping, the curing shall be done as per manufacturers specifications. After initial curing the imprinted joints shall be grouted using cement slurry mixed with color hardener as per the requirement. The surface shall be sealed by applying acrylic based sealer not less than 0.167 litre/Sqm on finished surface. * The construction joints shall be provided by grove cutting of size 4 mm x 20 mm in panel size 3 m x 3 m or lesser as per the site conditions and filling the same with 10 mm baker rod and providing & laying (PU) Polyurethane based joint sealer of approved make as per manufacturer’s specifications and finished by applying polyurethene resin based topprotective clear coat of minimum 80 micron applied with rollers on properly cured and dry clean surface. (The cost of concrete for flooring is not included in the item, which shall be paid for seperately). |
| 7 | Providing and laying 60mm thick factory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge. |
| 8 | Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge (length of finished kerb edging shall be measured for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-charge). |
| 9 | 12 mm cement plaster of mix :, 1:4 (1 cement: 4 fine sand) |
| 10 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :, Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 11 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :, Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 12 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 13 | Finishing walls with textured exterior paint of required shade :, New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @2.20kg/10 sqm. |
| 14 | Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete |
| 15 | Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq.meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-harge., With cement mortar 1:4 (1cement: 4 coarse sand). |
| 16 | 12 mm cement plaster of mix :, 1:4 (1 cement: 4 fine sand) |
| 17 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications :, Two or more coats applied on walls @ 1.25 ltr/10 sqm. over and including one coat of Special primer applied @ 0.75 ltr / 10sqm |
| 18 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 19 | Dismantling of flexible pavements and disposal of dismantled materials up to a lead of 100 m, stacking serviceable and unserviceable materials separately as per Technical Specification Clause 202 Manually Bituminous Courses MORD-202 (2.14) CH-25 LKO |
| 20 | Dismantling of flexible pavement (bituminous courses) by mechanical means and disposal of dismantled material up to a lead of 1 kilometre, as per direction of Engineer-in-charge. |
| 21 | Dismantling stone slab flooring laid in cement mortar including stacking of serviceable material and disposal of unserviceable material within 50 metres lead |
| 22 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge., Nominal concrete 1:4:8 or leaner mix (i/c equivalent design mix) |
| 23 | Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved. |
| 24 | Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved. |
| 25 | Supply and fixing of red square paver blocks of size 100mm x 100mm having thickness 60-80 mm where 9 pieces have a total coverage of 1sqft as per the direction of engineer in charge |
| 26 | Supplying and installing of Branding and Signage over Aluminium Composite Panel incuding the cost of printing and designing along with graphics and illustrations in font and language of approved size including the cost of suspended frame work from the existing wall. Also including cost of providing and fixing of fasteners complete in all respects as per Architect |
| 27 | Providing, fabricating and fixing/ erection of 6mm Decorative Metal Pendant Sigange including the cost of Ornamental casted bracket at desired location as per approved drawing and design including Designing along with graphics and illustrations in font and language in tentative size of 900*1800mm or as approved. Also including cost of providing and fixing of fasteners complete in all respects as per Architect in charge |
| 28 | Providing & Laying 100x100 mm with thickness ranging from 70-90mm rough finish granite cobbles stone and shape of approved and complete as per direction of Engineer-in-Charge, including transport, loading, unloading and conveyance of black cobbles granite from available source to work site, including labour charges for fixing the granite and pointing etc., complete |
| 29 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete., Hot finished seamless type tubes. |
| 30 | Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 31 | Providing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required., 1.00 mm thick with zinc coating not less than 275 gm/m* Please Enable Macros to View BoQ information |