| 1 | Name of Instrument |
| 2 | POLARIMETER |
| 3 | GAS CHROMATOGRAPH WITH ECD, TCD, FID WITH AUTOSAMPLER |
| 4 | HOT PLATE |
| 5 | LOVIBOND TINTOMETER |
| 6 | DIGITAL BUTYRO REFRACTOMETER |
| 7 | VACUUM OVEN |
| 8 | HOMOGENIZER |
| 9 | MICROWAVE DIGESTION SYSTEM |
| 10 | ROTARY EVAPORATOR |
| 11 | UV- VISIBLE SPECTROPHOMETER |
| 12 | PH METER |
| 13 | TURBIDITY METER |
| 14 | CONDUCTIVITY AND TDS METER |
| 15 | WATER BATH SHAKER |
| 16 | AUTO TITRATOR |
| 17 | BOMB CALORIMETER |
| 18 | AUTOMATED FAT ANALYSER |
| 19 | AUTOMATED PROTEIN ANALYSER |
| 20 | AUTOMATED FIBRE ANALYSER |
| 21 | ULTRA SONIC BATH |
| 22 | ORBITAL SHAKER (Refrigerated) |
| 23 | FLASH POINT APPARATUS (PENSKYU- MARTENS) |
| 24 | AUTOMATIC GLASSWARE WASHING AND DRYING SYSTEM |
| 25 | DIGITAL THERMOHYGROMETER |
| 26 | ABBE\"S REFRACTOMETER |
| 27 | REFRIGERATED CENTRIFUGE (BENCH TOP) |
| 28 | WATER PURIFICATION SYSTEM INCLUDING WATER SOFTER |
| 29 | FLAME PHOTOMETER |
| 30 | LABORATORY REFRIGERATOR |
| 31 | DEEP FREEZER (-20°C) |
| 32 | DEEP FREEZER (-40°C) |
| 33 | NITROGEN EVAPORTER |
| 34 | DIGITAL BALANCE 500GM (0.01g Accuracy) |
| 35 | ANALYTICAL BALANCE (0.0001g ACCURACY) |
| 36 | MUFFLE FURNACE |
| 37 | VORTEX MIXER |
| 38 | VISCOMETER |
| 39 | KARL FISCHER TITRATOR |
| 40 | WATER BATH |
| 41 | ULTRA PERFORMANCE CHROMATOGRAPHY (UPLC) WITH PHOTODIODE ARRAY (PDA), FLUORESCENCE (FLD) AND REFRACTIVE INDEX DETECTOR (RID) |
| 42 | ATOMIC ABSORPTION SPECTROPHOMETER (GTA/FLAME/VGA) |
| 43 | MAGNETIC STIRRER |
| 44 | MICRO FILTRATION ASSEMBALY |
| 45 | NITROGEN GENERATOR |
| 46 | HOT AIR OVEN |
| 47 | CENTRIFUGE (FLOOR MODEL WITH REFRIGERATION) |
| 48 | FT-IR WITH ATR & LIQUID CELL |
| 49 | List of Consumables |
| 50 | MUFFLE FURNACE Al2O3 Sample Plate, Al2O3 Furnace Door Block, Protection Glove, Crucible Clip, Crucibles |
| 51 | KARL FISCHER TITRATOR Titration Vessel, Detector Electrode with Lead, Generator Electrode (with Frit) with Lead, Desiccant Tube and Cap, Injection Septa (Pack Of 10), Gas Tight Syringe 1.0ml , Luer needle 17-gauge, Dust Cover, Results Manager Software, Main Power Pack, Fuse, Karl Fischer Titration Reagent(s), NIST Calibration standard |
| 52 | REFRIGERATED CENTRIFUGE (Bench Top) Bottles/falcon tubes/adapters for 0.2ml tubes, One set of Other items (adapters) required for improving the applicability/system performance should to be quoted |
| 53 | NITROGEN EVAPORATOR Evaporation tubes, Gas Fuse |
| 54 | WATER PURIFICATION SYSTEM INCLUDING WATER SOFTNER cartridges, filters etc. for |
| 55 | BOMB CALORIMETER Ignition wire, Cotton thread, Combustion crucible, Bomb, NIST certified Benzoic for calibration, Any other Accessories required for analysis of food samples. |
| 56 | GAS CHROMATOGRAPH WITH ECD, TCD, FID WITH AUTOSAMPLER Pesticide column (30 m x 0.250mm x 0.25µm (5MS (95% dimethyl-, 5% diphenyl-polysiloxane / 1MS (100% dimethyl polysiloxane or equivalent) 100 mm Column for Fatty Acid Profiling with main concern of Trans Fatty Acid Application, Column for Cholesterol Application, Stationary phase: 95% dimethyl-, 5% diphenyl-polysiloxane (30 m x 0.250mm x 0.25µm), Vial sets (1, 2 mL, Crimp type, Amber and Clear glass), Vials (10, 20ml Crimp type with cap & septa), 300/500 µL Recovery vials, Septa PTFE/Silicone (for 1, 2 mL Vials), Septa PTFE/Silicone (for 10, 20 mL Headspace Vials), Ergonomic Crimping Tools for different vial types, Ergonomic Decapping Tools for different vial types, Head Space vials 10,20 ml capacity, Suitable syringes for quoted autosampler, Suitable Headspace syringe /valve/loop, QuEChERS Kits for Pesticides and Herbicides in following Matrices:Matrices with high fat, Matrices with high Water content, Matrices with high pigmented, SPE cartridges for water. |
| 57 | ULTRA PERFORMANCE LIQUID CHROMATOGRAPHY (UPLC) With PHOTODIODE ARRAY (PDA), FLUORESCENCE (FLD) AND REFRACTIVE INDEX DETECTOR (RID) Sample Vials with 1.5 ml or greater, Stainless Steel Ultra Sonic bath with the capacity of 5 L or more, with Time setting (min) 1-30min or continuous operation with LED and Push button (Should be IP 33 Protection class) for sonication of spare parts as well as solvents, Fittings, Frits, ferules and Tubing’s, Tubing cutter, Solvent bottles (1000 ml capacity), Solvent filters (Glass & SS both, Compatible Manual syringes -10 µl, 20 µl, 50 µl, Standards for HPLC Calibration for PDA, RI and Fluorescence detector, Consumables required for each detector must be provided. HPLC Columns: One each ofC8 = 250 × 4.6 × 5μm C18 = 250 × 4.6 × 5μmCyano = 250 × 4.6 ×5μm. Amino = 250 × 4.6 × 5μmPhenyl = 250 × 4.6 ×5μm. Silica = 250 × 4.6 × 5μm.All columns must be supplied with respective guard column and holder. |
| 58 | UV-VISIBLE SPECTROPHOTOMETER ,0.5, 1 and 3-ml quartz cuvettes 10 mm path length, 0.5, 1, and 3 ml glass cuvettes 10 mm path length, Cuvette holder, Suitable Certified Standards for Validation including Holmium oxide glass filters for wavelength calibration & NIST traceable, NIST traceable Potassium dichromate. |
| 59 | UV-VISIBLE SPECTROPHOTOMETER ,0.5, 1 and 3-ml quartz cuvettes 10 mm path length, 0.5, 1, and 3 ml glass cuvettes 10 mm path length, Cuvette holder, Suitable Certified Standards for Validation including Holmium oxide glass filters for wavelength calibration & NIST traceable, NIST traceable Potassium dichromate. |
| 60 | FT-IR WITH ATR & LIQUID CELL • Hydraulic Press with KBr die and Pellet Holder• Suitable Mortar Pestle (dia 5-6 cm)• Suitable Portable De Humidifier to maintain 30- 60% RH• Temperature and Relative Humidity Digital Indicator with calibration certificate from ISO 17025 accredited lab.• Reference NIST Standard Polystyrene film (0.3 mm) over the range of 3800 cm-1 to 650 cm-1. |
| 61 | ABBE’S REFRACTOMETER Calibration block: and contact solution(1- Bromonaphthalene) and any other standard solutions |
| 62 | POLARIMETER Sample cells having stainless steel/Hastelloy with stopper. Sample Length Sample Volume1. 100 mm 1.5 ml2. 200 mm 2.0 mL |
| 63 | CENTRIFUGE (FLOOR MODEL WITH REFRIGERATION Bottles/falcon tubes/adapters for 0.2ml tubes. |
| 64 | AUTOMATED PROTEIN ANALYSER • Exhaust unit, Rack, stand, lid, 40 nos. of digestion tubes ≥250ml and all other required Accessories for stand-alone operation of the digester |
| 65 | ATOMIC ABSORPTION SPECTROPHOTMETER (GTA/FLAME/VGA) Standards: NIST traceable standards for each element separately 100 ml (1000 ppm) each for Na, K, Ca, Mg, Al, Fe, Mn, Ba, Sr, ,Cu, Cr, Ni, Co, Mo, Cd, Pb, Zn, As, Hg, Se Nitrous oxide gas, Acetylene gas, Argon gas, Nitrogen gas and Standards, Graphite Furnance tubes, Deutirioum Lamps, Nitric Acid Analytical Grade, Sulphuric Acid analytical grade. |