| 1 | Taking down and up old unsereviceable XLPE underground cable of any size from pole wall/roof/trenches, complete all as specified and directed. |
| 2 | Taking down old broken unserviceable, damaged/rusted swaged steel tublar poles/ cement poles of any size and remove from site, complete all as specified and directed. |
| 3 | Taking down old unsv burnt cable 1.5 sqmm to 6 sqmm size, complete all as specified and directed. |
| 4 | Taking down old unserviceable building security light/ street light/ flood light fitting of any type and any capacity and remove from its location, complete all as specified and directed. |
| 5 | Taking down old unserviceable post top lantern, decorative outdoor fitting of any capacity and any type and remove from its location, complete all as specified and directed. |
| 6 | Taking down old unserviceable looping box alongwith clamps nuts and bolts and removefrom its location, complete all as specified and directed. |
| 7 | Taking down/out old unserviceable rusted GI pipe light grade street light brackets building security light brackets and remove from its location, complete all as specified and directed. |
| 8 | Taking down/out old unserviceable rusted GI pipe light grade of 50mm/40mm/25 mm bore and remove from its location, complete all as specified and directed. |
| 9 | Supply and laying cable insulated screened PVC bedded,unarmoured, sheathed, electric power cables 1100 volts grade with stranded copper conductor of size 1.5 Sqmm x 3 core for connecting up topost top lantern, garden light and looping box, complete all as specified and directed. |
| 10 | Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated aluminium stranded conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed of size 4 sqmm x 2 Core in service connections, complete all as specified and directed. |
| 11 | Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated aluminium stranded conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed of size 6 sqmm x 2 Core in service connections, complete all as specified and directed. |
| 12 | Supply and fix looping box made out from fiber of size 300x200x112mm, out door type weather proof with locking arrangement & comprising of three phase connector and MCB SPN 10 Amp, with suitable bus bar arrangements and fix on pole with and including suitable size MS clamps, MS flat iron, cable glands, nut bolts, washers, complete all as specified and directed. |
| 13 | Supply and fix looping box made out from fiber of size 175x150x100mm, out door type weather proof with locking arrangement & comprising of connector MCB SPN 6 Amp and fix on pole with and including suitable size clamps, MS flat iron, cable glands, nut bolts, washers, complete all as specified and directed. |
| 14 | Material and labour GI tubing 50 mm dia light grade galvanized for cable protection and fixing of post top lantern with all connecting items (like suitable size of clamps, angle, nut & bolts) for holding of pipe with pole, complete all as specified and directed. |
| 15 | Supply and fix Steel tubular swaged poles type 410 SP-31 (9 metres long) complete with cast iron base plate, finial taper plug, bolts, nuts, screws and top cover, including double arm bracket of suitable size for fixing of street light all as specified and directed including the following:-(a) Excavation & earth work, will be measured and paid separatly under relevent items.(b) Material and labour for painting of pole externally with one coat of black bituminous paint (upto planting depth) and above plinth block/concrete collar with two coat of aluminium paint over a coat of red oxide primer, preparation of surface including painting of 30cm wide blue bands 3 Nos with synthetic enamel paint in alternate layer upto the height of 1.5m above plinth block.(c) Material and labour for writing letter or figures (Block, Roman, Italic as Indian) with thick synthetic enamel paint of approved shade not exc height in numbering of pole.(d) Drilling 02 Nos of holes to LT Pole (one hole near street light bracket and another near bus bar at bottom side) for insert of cable for street light. |
| 16 | Supply and fix for decorative pole antiquely designed aesthetically appealing landscape cum street light(3 metres long) along with single arm hanging braket of suitable size made out from ERW pipe with base plate, finial taper plug, bolts, nuts, screws and top cover, suitable for fixing one Nos hanging light and testing, complete all as specified and directed. |
| 17 | Supply and fix for decorative pole antiquely celesta designed aesthetically appealing landscape cum street light made out from aluminium housing pole type (3.50 metres long) along with single arm hanging braket of suitable size made out from ERW pipe with base plate, finial taper plug, bolts, nuts, screws and top cover, suitable for fixing one Nos hanging light and testing, complete all as specified and directed. |
| 18 | Supply and fix for octagonal poleantiquely designed aesthetically appealing landscape cum street light made out from hot deep galvanised (7 metres long) along with single armbracket of suitable size made out from galvenised pipe complete with base plate having holes for mounting on foundationfinial taper plug, bolts, nuts, screws and top cover, suitable for fixing street light and testing, complete all as specified and directed. |
| 19 | M&L PCC 1:3:6 type C-1 (using 20mm graded crushed stone aggregate) for making foundation of poles/ post top lanterns/ decorative lights, complete all as specified and directed. |
| 20 | M&L PCC 1:2:4 type B-1 (using 20mm graded crushed stone aggregate) for making coping of Street light poles post top lanterns/ decorative lights, complete all as specified and directed. |
| 21 | S&F LED Hanging light Aluminium housing polymer defuser and pleasant lumin output IP -65 of capacity 40 watt LED 0f 6000k/3000k as per requirment on site including neccesary brakets made out from GI pipe of suitable size and shape complete testing on ground, complete all as specified and directed. |
| 22 | S&F LED Post top lantern fitting of capacity 25 watts, 100 lumen per watt capacity of 6000k/3000k as per requirment on site including GI Pipe in wall and all necessary fixing arrangement, complete all as specified and directed. |
| 23 | S&F for LED Post top gate light fitting of capacity 50 watts, 100 lumen per watt capacity 0f 6000k/3000k as per requirment on site including GI Pipe in wall and all necessary fixing arrangement, complete all as specified and directed. |
| 24 | S&F LED Post top lantern heritage light fitting of capacity 20 watts, 100 lumen per watt IP 65of 6000k/3000k as per requirment on site including GI Pipe in wall and all necessary fixing arrangement, complete all as specified and directed. |
| 25 | S&F LED BOLLARD light fitting of capacity 9 watts, 100 lumen per watt IP 650f 6000k/3000k as per requirment on site including necessary fixing arrangement, complete all as specified and directed. |
| 26 | S&F LED BOLLARD mushroom type light fitting of capacity 9 watts, 100 lumen per watt IP 650f 6000k/3000k as per requirment on site including necessary fixing arrangement, complete all as specified and directed. |
| 27 | S&F LED spot decorative spike light fitting of capacity 10 watts, IP 65 0f 6000k/3000k as per requirment on site including necessary fixing arrangement, complete all as specified and directed. |
| 28 | Supply and fix 6 watt fountain light, IP-66, in warm white colour, of 6000k/3000k as per requirement on site of 6000k/3000k as per requirment on site, complete all as specified and directed. |
| 29 | Supply and fix 9 watt wall light, IP-66, in warm white colour, of 6000k/3000k as per requirement on site of 6000k/3000k as per requirment on site, complete all as specified and directed. |
| 30 | M&L for painting external surface steel tubular poles 9 metre/ Decorative Poles 33 meter/ Octagonal Poles 7 meter long of any type complete andcross arm/bracket etc with two coats of aluminium paint and black paints inalternatestrip upto 1.50 metre (each strip of 30 cm)with super enamel synthetic paint from bottom and remaining portion shall be painted with two coats of aluminium paint of LT pole including preparation of surface and marking pole No, complete all as specified and directed. |
| 31 | Supply and fix LED street light fitting of capacity 90 watt, luminaire fixture in IP 66 protection level with aluminum pressure die cast reflector with heat shrink LM 6, dedicated optics with precise light distribution SDMC not less than 5 uniform lighting quality and UV stabilized, output of LED lamp efficiency 100 luman per watt after all losses, protection against biological eye safety certification and UV,and including suitable bracket MS clamps made out of 32 x 6mm thick flat with nuts, bolts and washers, complete all as specified and directed. Note: Contractor should arrangeall necessary materials including aluminium movable ladder of required height all safety measures should be ensured by contractor. |
| 32 | Supply and fix LED flood light fitting of capacity 200 watt, luminaire fixture in IP 66 protection level output of LED lamp efficiency 100 luman per watt after all losses, driver with 4KV surge high and low voltage protection, power factor not less than 0.97, life of LED 50,000 burning hours at L 70, protection against biological eye safety certification and UV and including suitable bracket andfixed to pole/ wall with two Nos. MS clamps made out of 32 x 6mm thick flat with nuts, bolts and washers etc. of 6000k/3000k as per requirment on site, complete all as specified and directed. Note: Contractor should bring all necessary materials including aluminium movable ladder of required height all safety measures should be ensured by contractor. |
| 33 | Supply and fix LED flood light fitting of capacity 150 watt, luminaire fixture in IP 66 protection level output of LED lamp efficiency 100 luman per watt after all losses, driver with 4KV surge high and low voltage protection, power factor not less than 0.97, life of LED 50,000 burning hours at L 70, protection against biological eye safety certification and UV and including suitable bracket andfixed to pole/ wall with two Nos. MS clamps made out of 32 x 6mm thick flat with nuts, bolts and washers etc. of 6000k/3000k as per requirment on site, complete all as specified and directed. Note: Contractor should bring all necessary materials including aluminium movable ladder of required height all safety measures should be ensured by contractor. |
| 34 | Supply and fix LED flood light fitting of capacity 100 watt, luminaire fixture in IP 66 protection level output of LED lamp efficiency 100 luman per watt after all losses, driver with 4KV surge high and low voltage protection, power factor not less than 0.97, life of LED 50,000 burning hours at L 70, protection against biological eye safety certification and UV and including suitable bracket andfixed to pole/ wall with two Nos. MS clamps made out of 32 x 6mm thick flat with nuts, bolts and washers etc. of 6000k/3000k as per requirment on site, complete all as specified and directed. Note: Contractor should bring all necessary materials including aluminium movable ladder of required height all safety measures should be ensured by contractor. |
| 35 | Supply and fix LED flood light fitting of capacity 50 watt, luminaire fixture in IP 66 protection level output of LED lamp efficiency 100 luman per watt after all losses, driver with 4KV surge high and low voltage protection, power factor not less than 0.97, life of LED 50,000 burning hours at L 70, protection against biological eye safety certification and UV and including suitable bracket andfixed to pole/ wall with two Nos. MS clamps made out of 32 x 6mm thick flat with nuts, bolts and washers etc. of 6000k/3000k as per requirment on site, complete all as specified and directed. Note: Contractor should bring all necessary materials including aluminium movable ladder of required height all safety measures should be ensured by contractor. |
| 36 | Supply and fixing LED building security light fitting 45 Watt, luminaire fixture in IP 66 protection level output of LED lamp efficiency minium 100 luman per watt after all losses , pressure die-cast aluminium housing LED Street light, complete all as directed by Engineer-in-Charge. Note: Contractor should bring all necessary materials including aluminium movable ladder of required height all safety measures should be ensured by contractor. |
| 37 | Supply and fixing LED building security light fitting 60 Watt, luminaire fixture in IP 66 protection level output of LED lamp efficiency minium 100 luman per watt after all losses , pressure die-cast aluminium housing LED Street light, complete all as directed by Engineer-in-Charge. Note: Contractor should bring all necessary materials including aluminium movable ladder of required height all safety measures should be ensured by contractor. |
| 38 | Disconnecting existing LT cable of street light pole from junction box and placing the GI pipe of minimum 60mm dia minimum 0.6 meter length from one end of the LT cable and fixing the GI pipe on the pole tightly with the with help of clamp nuts and reconnecting the LT cable to the juction box, complete all as specified and directed by Engineer- Incharge. |
| 39 | S&F in repairs LED based of rating 9 watts thread type/ Pin type bulb suitable for decorative lights, complete all as specified and directed by Engr- In-Charge. |
| 40 | S&F in repairs warm white LED based of rating 9 watts thread type/ Pin type bulb suitable for decorative lights, complete all as specified and directed by Engr- In-Charge. |
| 41 | S&F in repairs LED based of rating 12 watts thread type/ Pin type bulb suitable for decorative lights, complete all as specified and directed by Engr- In-Charge. |
| 42 | S&F in repairs warm white LED based of rating 12 watts thread type/ Pin type bulb suitable for decorative lights, complete all as specified and directed by Engr- In-Charge. |
| 43 | S&F in repairs LEDbased of rating 14 watts warm white thread type/ Pin type bulb suitable fordecorative lights, complete all as specified and directed by Engr- In-Charge. |
| 44 | S&F in repairs E27 Heat Resistant Ceramic Bulb Holder /Infrared Lamp Holder/IR Bulb Holder/Heat Resistant Ceramic Bulb Holder, complete all as specified and directed by Engr- In-Charge. |
| 45 | M&L for Replacement of Earthing complete with galvanized steel earth plate electrode 60 cm x 60cmx6.3 mm thick, buried directly in ground vertically (earth pit not less than 2.25 m deep below ground level) with top edge of the earth plate not less than 1.5m below ground level , connected to4 mm dia GI wire as earthing lead by means of blots and nuts check nuts and washers of galvanized iron and connected to main switch board including watering pipe 20mm dia medium grade with PCC chamber, MS funnel, wire gauge,CI cover with frame, 15 mm dia GI pipe light grade for protection of earth wire etc including necessary excavation in any type of strata, returning, fillingremoval of soil outside MD land, filling ofcharcoal andsalt all as shown in electrical plate No. 3 of MES Sch Part I, connected to earthing test point, testing on completion all as specified and directed. Note : Meggering value of earthing should be less than 2 Ohm. |
| 46 | Supply and fixLT XLPE insulated screened, PVC bedded galvanized steel strip or wire armoured electric power cable heavy duly , IS-7098 Part-II, with stranded aluminum conductor LT 1100 voltsgrade of size 35 Sqmm x 4 core with lugs and ferruls of suitable size, complete all as specified and directed. |
| 47 | Supply and fixLT XLPE insulated screened, PVC bedded galvanized steel strip or wire armoured electric power cable heavy duly , IS-7098 Part-II, with stranded aluminum conductor LT 1100 voltsgrade of size 25 Sqmm x 4 core with lugs and ferruls of suitable size all as specified and directed. |
| 48 | Supply and fixLT XLPE insulated screened, PVC bedded galvanized steel strip or wire armoured electric power cable heavy duly , IS-7098 Part-II, with stranded aluminum conductor LT 1100 voltsgrade of size 16 Sqmm x 4 core with lugs and ferruls of suitable size, complete all as specified and directed. |
| 49 | Supply and fixLT XLPE insulated screened, PVC bedded galvanized steel strip or wire armoured electric power cable heavy duly, IS-7098 Part-II, with stranded aluminum conductor LT 1100 voltsgrade of size 10 Sqmm x 4 core with lugs and ferruls of suitable size, complete all as specified and directed. |
| 50 | Supply and fixcable LT XLPE insulated screened, PVC bedded galvanized steel strip or wire armoured electric power cable heavy duly, IS-7098 Part-II, with stranded aluminum conductor LT 1100 voltsgrade of size 10 Sqmm x 2 core with lugs and ferruls of suitable size, complete all as specified and directed. |
| 51 | Labour only for taking out and checking of underground cable and relaying /rerouting the same cable of any size and any capacity including making servicable electric connections, complete all as specified and directed by Engr- In-Charge. |
| 52 | Supply and fixing in repairs testing and commissioningof multifunction timer switch digital 24 hour three phase complete with timer, contactor and suitable rating MCB s for incoming and out going in built in suitable sheet metal enclosure panel and working in Single/Three phase integrated models of cpacity 63 Amp, complete all as specified and directed. Make : Havells, L&T or equivalent Models of crompton/schinder as approvedby GE). |
| 53 | Material and labour for cutting existing hard standing by manual method, 0.45 m width and 0.6 m in depthfor inserting galvanized tubing for cable protection, refilling the same after laying of pipe, with soil, stone aggregate etc., as obtained from excavation, making good top surface with 100mm thick PCC (1:2:4), type BI (using 20mm graded crushed stone aggregate) and removal of excess material if anye, complete all as specified and directed by Engr- In-Charge.Note:- Cost of taking out of old GI pipe is deemed to be included in the quoted rate. |
| 54 | S&F GI clamp including connected accessories and bracket made of GI Pipe 50mm dia light grade 1.25 m long,bend to shape with two sets of MS flat iron clamps, nuts, bolts, washers etc including two coats of synthetic enamel paint over a coat of red-oxide primer, complete all as specified and directed. |
| 55 | S&F Street light BEST pattern brackets suitable 410 SP-31 pole made out of GI pipe 50mm bore light grade 1.50 metre long bend to shape including welding etc with cap diameter suitable to SP-31 pole to required shape and necessary nut bolt washer, including two coats of synthetic enamel paint over a coat of red-oxide primer, complete all as specified and directed. |
| 56 | S&F Street light single arm bracket made out of GI pipe 40 mm bore light grade 1.50 metre long bend to shape including welding etc and two sets of clamps made out of MS 40mm x 5mm bent to required shape and necessary nut bolt washer, including two coats of synthetic enamel paint over a coat of red-oxide primer, complete all as specified and directed. |
| 57 | S&F Street light double arm brackets made out of GI pipe 40 mm bore light grade 1.50 metre long bend to shape including welding etc and two sets of clamps made out of MS 40mm x 5mm bent to required shape and necessary nut bolt washer, including two coats of synthetic enamel paint over a coat of red-oxide primer, complete all as specified and directed. |
| 58 | Labour only for cutting small bushes of trees around two metre radius of street light fitting serviciability checking of street light fitting, for each pole of street lights, complete all as specified and directed. |
| 59 | Excavation in trenches not exceeding 1.50m wide and not exceeding 1.50m depth and getting out in hard/dense soil/RCC/PCC for laying of cable/ GI pipe, complete all as specified and directed. |
| 60 | Returning, filling in including spreading levelling watering well ramming in layers not exceeding 25cm thick each layer, complete all as specified and directed. |
| 61 | Removing surplus soil to a distance outside MD land and depositing n.exc. 50mwhere directed at a level not exceeding 1.50m above the starting point all in including removing balance debries from MD land, complete all as specified and directed. |
| 62 | M&L PCC 1:2:4 type B-1 (using 20mm graded crushed stone aggregate) in for road filling and mass concrete, complete all as specified and directed. |
| 63 | Supply and providingunreinforced pre cast cement concrete cable covers for cable protection (Ready made Covers) ofsizes Class LVtype I, flat size 250x150x40 mm putting adjecent to each other, complete all as specified and directed. |
| 64 | S&F in replace ofLED security light timer switch 24 Hourdigital type suitable for 63 Amp 3ph, complete all as speified and directed. Make L&T or equivalent. |
| 65 | S&F in replace ofLED security light contactor switch of 63Amp 3ph 4P suitable for 63 Amp 3ph timer, complete all as speified and directed. Make L&T MNX63 or equivalent. |
| 66 | S&F in replace of LED security lightMCB of 63Amp 3ph 4 p suitable for 63 Amp 3ph timer, complete all as speified and directed. Make L&T or equivalent. |
| 67 | S&F in replace of LED security light driver suitable for 15 watt to 40 watt of 100 lumen per watt IP 65of 6000k/3000k as per requirment on site including necessary fixing arrangement, complete all as specified and directed. |
| 68 | S&F in replace of LED security light driver suitable for 50 watt to 100 watt of 100 lumen per watt IP 65of 6000k/3000k as per requirment on site including necessary fixing arrangement, complete all as specified and directed. |
| 69 | S&F in replace of LED security light driver suitable for 100 watt to 200 watt of 100 lumen per watt IP 65of 6000k/3000k as per requirment on site including necessary fixing arrangement, complete all as specified and directed. |
| 70 | S&F in repairs steel perforated trunking system of size 60x30 mm and providing sturdy nuts and bolts for connecting cable trunking steadily onto walls or lying in air steadily with help of metal frame, complete all as specified and directed. |
| 71 | S&F in repairs PVC trunking system of size 60x30 mm and providing sturdy nuts and bolts for connecting cable as per requirment on site including necessary fixing arrangement, complete all as specified and directed. |
| 72 | S&F in repairs sheet metal enclosures double door, for DBs when MCBs to be used 240 volts 8 way with 200 Amps rated bus bar for single pole and neutral fixed on wall by cutting chasing and making good to the disturbed surfaced board in and including copper lugs/thimbles duly crimped for connection, complete all as specified and directed. |
| 73 | S&F in repairs sheet metal enclosures double door, for DBs when MCBs to be used 240 volts 12 way with 200 Amps rated bus bar single pole and neutral fixed on wall by cutting chasing and making good to the disturbed surfaced board in and including copper lugs/thimbles duly crimped for connection, complete all as specified and directed. |
| 74 | S&F in repairs MCB SP 240 volt, 16 to 63 Amps, C series all as specified and directed. Note: Thimble/lugs of rating of MCB should be used with wire for fixing in the MCB, complete all as specified and directed. |
| 75 | S&F in repairs MCB SPN 240 volt, 20 to 63 Amps, C series, complete all as specified and directed.Note: Thimble/lugs of rating of MCB should be used with wire for fixing in the MCB. |
| 76 | Supply, installation, testing and commissioning of factory made, CPRI / ERDA type tested, fully compartmentalized bolted type OUTDOOR GARDEN LIGHTS PANEL of suitable size conforming to IEC 61439-1 & 2 and IEC 61641 and having modular extensible design suitable for indoor mounting, internal arc compliance of minimum 70 kA for 0.5 s, made out of 2mm thick mild steel CRCA sheet, having both sides openable with hinged doors and locking arrangement, IP 54 & IK 10 protection, supported and fixed on structural frame of angle iron of suitable size, including earthing stud, labelling, painting to all internal & external exposed steel surfaces with powder coating paint (7 tank process), duly fixed in ground with PCC foundation (1:2:4) type B-1, with danger notice plate of 1.6 mm thick mild steel vitreous enamelled (white) with letters, figures and conventional skull and bones in signal red colour suitable for 3-Phase, 4-Wire system, 500 V grade with necessary wiring, PVC sheathed stranded copper conductor of appropriate length and size, including fixing lugs, bolts, screws, etc., including taking out old panel, complete all as specified and directed by the engineer-in-charge. The OUTDOOR FEEDER PANEL shall comprise of the following: Set (3L + N) of copper busbar of rated capacity 200 A, covered with PVC insulated sleeves including insulator, nuts, bolts, etc. with complete connection. INCOMING:-(i) MCCB 4 pole, 415 Volts, 63 Amps, 10 KA - 01 No. OUTGOING:-(i) MCB 2 pole, 240Volts,40 to 63 Amps, - 12 No.(ii) MCB 1 pole, 240Volts, 20 to 32 Amps, - 10 No.INSTRUMENTS & COMPONENTS:-(i) Voltmeter LED type 0-500 V. (ii) Ammeter LED type 0-200 A.(iii) CT 100/5 Amp,3 Nos. (iv) Phase indicator lamps (RYB) -set of 3. (v) Aluminium bus bar TPN 200Amps (electro-plated with aluminium). (vi) Internal wiring for panel incl insulators, sleeves etc. (vii) POWDER COATINGand treatment as per CPRI. |