| 1 | Demolition of cement concrete any in ground floors and pavings anythickness complete all as specified and directed by Engr-in-Charge. |
| 2 | M&L Repairs old gate Steel rolling shutters / main gate of any thikness including taking down & refixing with some altration like welding, fixing some articles & refixing in same opening with gear operated type with bevel gear box and crank handle as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer; erected in position as indicated, complete: push pull ormanual type complete all as specified and directed |
| 3 | S&F prepainted galvalume aluminium zink coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550MPa as in roof covering/cladding to wall, fixed with self tapping screwincluding necessary scaffolding,any type any location/height complete all as specified |
| 4 | S&F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws including necessary scaffolding, anytype, any location/ height complete all as specified |
| 5 | S&F Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.11611979 grade St.-240structural steel is painted one shop coat of zinc chromate primer paint (including preparation of surface) at Contractor’s workshop before fabrication all as specified and directed. |
| 6 | M&LFramed work as in doors orgates of angle or other section with gusset plates, rails,braces, etc., complete, drilled forfixing of steel sheeting or othercovering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete |
| 7 | M&L for applying two coats of synthetic enamel paint over a coat of red oxide primer including preparation of new steel surfaces of any description over 10cm width or girth not otherwise described andall as specified and as directed. |
| 8 | M&L PCC 1:3:6 type C-2 (using 40mm graded crushed stone aggregate) as infoundations, filling and mass concrete, complete all as specified. |
| 9 | Excavating in trenches, n exc1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft/loose soil complete all as specified and directed. |
| 10 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm. of hard/dense soil complete all as specified and directed. |
| 11 | Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed |
| 12 | M&L for Brickwork with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius built in CM 1:6 as in wall/septic tank/soakage well all as specified and directed. |
| 13 | M&L for non skid ceramic tiles, joint free, coloured tiles7mm to 8 mm thick (Square or rectangular) area of tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc set & jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tile laid over and including 15 mm thick screed bed orbedding layer of cement mortar (1:6)complete all as specified and directed. |
| 14 | M&L for Glazed ceramic tiles in vertical surface 450 x 600 x 7mm thick set and jointed in neat cement slurry set & jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tile including 15 mm thick screed bed orbedding layer of cement mortar (1:4)complete all as specified and directed.and pointed in white or colour cement to match. |
| 15 | S&F 110mm diaPVC (SWR) pipes single socketed, in any length, laid in trenches or in floors / fixed to walls incl. clamps & screw. |
| 16 | S&F 75mm diaPVC (SWR) pipes single socketed, in any length fixed to walls / floors or in trenches |
| 17 | S&F 110mm dia PVC (SWR) bends any radiucomplete all as specified and as directed |
| 18 | S&F 75mm dia PVC (SWR) bends any radiucomplete all as specified and as directed |
| 19 | M&L 75 mm thick plain cement concrete type D2 1:4:8using 40 mm graded crushed stone aggregate as in sub base complete all as specified and directed by Engr-in-Charge. |
| 20 | M&L Rendering 15mm thick on fair faces of brick work, stone masonry or concrete surface, in cement mortar 1:4 finishedthe surface even and smooth without using extra cement , complete, all as specified |
| 21 | M&L for two coats of Camouflage painting over a coat of primer on newly plastered external walls of colour complete all as specified and directed. |
| 22 | Excavation in treanches soft/loosesoil not exceeding 1.5 mtr wide and not exceeding 1.5mtr in depth for foundation etc or for shaft well, cesspits, manholes, pireholes etc not exc 10 Sqm on plan and getting out in soft/loose soil, complete all as specified. |
| 23 | Returning & filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 CM thick in soft/ loose soil, complete all as specified. |
| 24 | Removing excavated material not exceeding 50mtr and deposting where directed at a level not exceeding 1.5mtr above the starting point complete all as specified. |
| 25 | M&L for sand cushioning (dry sand) to under ground cable for cable protection with layer of 8 cm deep before laying the cable and 15 cm depth after laying the cable, complete all as specified.Note :Punned thickness of sand layers shall be measured and paid contractor. |
| 26 | M&L for brick, subclass \"B\" well burnt, laid dry flat in trenches for protection of cable over LT/HT cable, complete all as specified. |
| 27 | Supply laid in trences/ fixing with pole/ connecting, thembling, glandingofXLPE insulated under ground screened PVC badded, galvanised steel strip or wire armoured, electric power cable (Heavy duty) 1100 volts grade with stranded aluminium conductor of size 16 Sqmm 4 core (earhted) complete all as specified. |
| 28 | Material and labour for sub main wiring with two runs of single core PVC FRLS IS-694 cable with unsheathed multi-stranded copper conductor of size 2.5 Sqmm and drawing through in concelead rigid non metallic PVC conduit pipe medium grade heavy duty in suitable size with all necessary fittings including one run of FRLS insulated unsheathed stranded copper conductor cable of size 2.5 Sqmm as earth wire (green in colour) and connected to common earth dolly complete including taking down of old unserviceable sub main wiring complete all as specified and as directedNote;-(i) Two run of 2.5 sqmmwith one run of PVC conduit pipe shall be measured agaist one unit. (ii)Cost of cutting /chasing/ plastering /colouring etc as site shall be included matching to disturbed surface all as existed. |
| 29 | Supply, installation, testing and commisioning of single phase geared AC induction motor for sliding gate upto 800Kg weight having 220 volts, 50 Hz, single phase, 550W provide high torque at low speed ensure accurate stopping of gate at fully open and fully closed options with tntegrated electronic control board inside the motor housing which supports configuration of opening/ closingwith heavy duty outer closing designed for outdoor installation, consisting of push button- 01 No. Motor shall be operable with manual push button and remote control transmitter- 02 Nos (remote control operating range shall be approximately 30-50 meters in open line-of-site condition). Motor shall include wireless safety photocell sensor to detect obstacle in the movement path of the gate.Note:- (i) Quoted rate include cost of MS module rack suitable for gate sliding. (ii) Quoted rate shall include rate for demolition and reconstruction of RCC work; required for the foundation of moving gate or motor.(Gate not included) |
| 30 | M&L in replacement earthing complete withgalvanized steel earth plate 600 x600 x 6mm thick, buried directly in ground(earth pit not less than 2.25 Mtr deep below ground level) with top edge of the plate not less than 1.5 Mtrs belownormal groundlevel, connected to galvanized GI earth lead wire 4.0mm dia as earthing lead by means of bolts, nuts, check nuts & washers of galvanized iron or steel besides building at all joints including excavation and earth work, GI pipe light grade 40 MM bore for protection of GI strip from earth electrode and 15 MM as watering with wiremesh funnel charcoaldust, common salt, PCC (1:2:4)type B-1 using 20 MMgraded stone aggregate for chamber and MS angle iron frame 40x40x3 MM and RCC cover 40 MM thick (1:2:4)type B-1 using 20 MM graded stone aggregate reinforced with 6 MM dia round bars@75 MM C/C both ways with MS handle 12 MM dia , PGI funnel and wire mesh , 20 MM bore GI Pipe light grade for wateringcomplete all asshown in electrical plate No 3 of SSR Part-I(2009) and connected to earth test point including testing complete all as specified and directed. Note : Quote rstes shall be included the cost of srtip upto 7.5 Mtr and required earth work.. |
| 31 | M&L for repair/servicing of moving target machine trolly type operated with 220 volt, 50 Htz. Machine comprises of 0.33 HP motor, 0.33 HP frequency drive motor, on/off remote control, target on/off remote, limit switch assembly, timer, RF antina, bearing, wheel, worm gear box, moving target gear bearing etc to make fully functional and operational in working condition by repairing or replacing the spare parts.Nore:- 1. Unit rate is inclusive of transportation, required spare parts, nut bolts, other necessary accesories etc to complete the job.2. Testing of moving target machine will be done in presence of user and Engineer in charge3. Contractor has advised to visit the site before quoting the rate for correct assessment of work. |
| 32 | Note:- (i) Make of material shall be as per mentioned in Particular specifications or Appendix \"B\" to Particular specifications as approved by AGE (I) AF manauri |