| Sl. No. | Item Description |
| 1 | M & L Racking out of old existing sealant compound andback up rod of the existing Dummy joints by special tools likecutting blades/machines, widening of joints by 2 mmby using joint cutting blades of appropriate sizestraight and smooth edges. Joint cleaned thoroughlywith application of compressed air. Joint shall bemade dry, vacuum cleaned and free of dirt, oilvegetation and other debris Application of two coatsof primer with thin brush by forward and backwardmovement at an interval of 30 minutes before pacingthe backup rod and pouring the sealant. Thereafterfilled with closed cell, medium density, cross linkedpolyethylene foam backup rod of 8 mm dia focomplete length of the joint, over it to be filled withpolyurethane joint sealant meeting the requirementsmentioned in BS-5212, BS 4254 and EN-141875- 2003 with minimum movement accommodationfactor (MAF) of+/- 30% complete all as specified and directed by Engineer-in-Charge. |
| 2 | M & L Racking out of old existing sealant compound andback up rod of the existing construction joints by special tools likecutting blades/machines, widening of joints by 2 mmby using joint cutting blades of appropriate sizestraight and smooth edges. Joint cleaned thoroughlywith application of compressed air. Joint shall bemade dry, vacuum cleaned and free of dirt, oilvegetation and other debris . Application of two coatsof primer with thin brush by forward and backwardmovement at an interval of 30 minutes beforepouring the sealant Thereafter filled with closed cellmedium density, cross linked polyethylene foambackup rod of 12 mm dia for complete length of thejoint, over it to be filled with polyurethane joint sealantmeeting the requirements mentioned in BS-5212 , BS4254 and EN-141875-2003 with minimum movementaccommodation factor (MAF) of+/- 30% complete all as specified and directed by Engineer-in-Charge. |
| 3 | M & L Racking out of old existing sealant compound, backup rod and filler board of the existing expansion joints by speciatools like racker/cutting blades/machines , wideningof joints by 2 mm by using joint cutting blades ofappropriate size, straight and smooth edges. Jointcleaned thoroughly with application of compressedair. Joint shall be made dry, vacuum cleaned andfree of dirt, oil, vegetation and other debrisApplication of two coats of primer with thin brush byforward and backward movement at an interval of 30minutes before placing the filler board and pouringthe sealant Thereafter filled with pre-molded 25 mmthick compressible polyethylene closed cell type filler board as specified , over it filled with closed cellmedium density, cross linked polyethylene foambackup rod of 30 mm dia for complete length of thejoint. Finally filled with polyurethane joint sealantmeeting the requirements mentioned in BS-5212, BS4254 and EN-141875-2003 with minimum movementaccommodation factor MAF of+/- 30% complete all as specified and directed by Engineer-in-Charge. |
| 4 | Preparing and cleaning of broken edges of concrete pavement joints of any type and shape free from loose particles, grease, oil, demolding agents etc., cutting and chiseling the existing damaged portion of edges of joints to provide a regular prismatic cavity as directedand cleaning by using blower etc and washed with acid solutions if required and applying primer coat of epoxy ( 100 parts of epoxy resinwith 50 parts of epoxy hardner by weight proportion) and filling the cut portion with epoxy mortar of Make: Huntsman (with 100 parts of epoxy resin, araldite with 50 parts of epoxy hardner, Aradur mixed with 800 parts of quartz sand by weight) including provision of temporary wooden strips or metal strips as formwork to edges of expansion/contraction/dummy joints and trowelling the mixture to level with the adjoining surface all as per manufacturers instructions complete all as specified. . |
| 5 | Demolition of brick work or stone masonary built in cement mortar including all quoins, arches, pillars etc.complete all as specified and directed |
| 6 | M&L for precast Solid Block Masonry type 1:3:6 type C1 (20 mm Aggregate) set in cement mortar 1:6 all as specified and as directed by engineer in charge |
| 7 | M & L for precast cement concrete solid building blocks or slabs 10cm thick (with plain or interlocking joints as directed)1:3:6type C1,setting in CM 1:6 mortar,complete, in walls |
| 8 | Taking down cement plaster alongwith tiles on brick or stone wall surfaces including raking out joints, hacking for key and scrubbing down with water complete all as specified and directed by Engr-in-charge. |
| 9 | M&L for rendering 15mm thick in cement mortar 1:4 on other than fare face of brick work or concrete surfaces and finishing the surface even & smooth without using extra cement on any height complete all as specified and directed by Engr-in-charge. |
| 10 | M&L for applying two coat of exterior Acrylic emulsion paint (100% acrylic having VOC less tan 50gm/ltrand UV resistant as per IS 15489;2004) akali & fungal resitantance exterior paint of approved colour and shade over one coat of primer and 1 to 2mm thick putty punning including preparation of new plastered surface complete all as specified and as directed by Engineer-in-charge. Make-Asian (Apex Ultima) paints/Berger (Whether coat long life) including necessary scaffolding . |
| 11 | M & L for PCC 1:3:6 Type C2 (using 40mm Graded stone aggregate) as in for fixing posts, bed plates, anchor blocks, corbels, brackets, including necessary form work etc. complete all as specified and as directed. |
| 12 | M&L for HCRM TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bendin spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified |
| 13 | M&L for HCRM TMT bars 6mm dia and over, cut to length, bent to shape required, including cranking, bendin spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified |
| 14 | M&L for precast reinforced concrete 1:2:4 type B-1 (Nominal mix) using 20 mm graded crushed stone aggregates as in cover slab for manholes except set in cement mortar 1:4 including angle iron welded frame and hold fasts, all as specified and as directed. (Reinforcement to be measured and paid for separately). |
| 15 | Demolition of cement concrete (unreinforced) in ground floor and paving not exceeding 15 cm thickness (below or above ground level) complete all as specified and directed by Engr-in-charge. |
| 16 | M&L for 40 mm thick PCC 1:2:4 type B-1 using 20 mm graded stone aggregate surface finished even and smooth using extra cement as in flooring complete all as specified and directed by Engr-in-charge. |
| 17 | Supply and fix Mild steel angle iron section as in greting ,hand rails, half round or other steel section or straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts;posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165complete all as specified and directed. |
| 18 | Material and labour for applying two coats of synthetic enamel paint over one coat ofred oxide primer on new steel surfaces over 10 cm wide or girth including preparation of surface etc., complete all as specified and directed. |
| 19 | M&L for groove cutting girth exc 15cm but not exc30cm in concrete surface of any description with reinforcement or with out reinforcement complete as specified and directed |
| 20 | M&L foradequate no of coats of Painting lines arrows, dashes , letters etc road pavement and like not execeeding 10cm wide with road marking paints complete all as specified and directed by EIC,Make : STP/ASIAN/Equalient |
| 21 | M&Lpreparation of and complete removal of old existing Aircraft Dispersal marking paint of any description and providing and applying 2.50mm thick road marking with hot applied thermo plastic road marking paintn exc 10 cm wide over rough finished concrete surface of Aircraft dispersal/parade ground etc of any shade/colour approved by Enginer In-charge complete all as specified and directed.Make : STP/ASIAN/Equalient |
| 22 | M&L for preparation of old painted brick ,stone, concrete work or plastered surfaces of any description over 10 cm width or girth and applying two coat of plastic emulsion paint complete all as specified and directed by Engr-in-charge. |
| 23 | Removal of debris/malwa/surplus soil to a distance exc 1.50 Km but n exc 5.00 Km out side MD land and depositing where as directed, complete all as specified and directed by Engr-in-charge.Notefor Serial item No. 1 to 23: Kind attention of tenders is invited to that Air dispersal area will be available to execute the work on Saturday and Sunday or on holiday or as required by the user. The tenderer has to work as per user\"s requirement and unit rate quoted by the tenderer shall be deemed to include for this provision/condition |
| 24 | Dismantling floor, stone, hearth or wall tiling including cement mortar bedding but not backing, removing serviceable tiles to store and rubbish off the premises complete all as specified and directed by Engr-in-charge. |
| 25 | M&L for 25mm thick PCC 1:2:4Type B0 (12.5mm Graded Stone Aggregate) as in sub flooretc., including rough top surface to receive floor finish complete all as specified and as directed. |
| 26 | Material and Labour for glossy finish coloured vitrified ceramic tiles 8-10 mm thick of area of each tiles not exceeding 0.42 sqm but not exceeding 1.0 Sqm, of any shade of any pattern (pattern consists combination of two or more tiles ) as in vertical surfaces etcjointed in neat cement slurry and pointed in colored cement to match colour tiles over and including 10mm thick screed bed in CM 1:4 and pointed in coloured cement to match coloured tiles complete all as specified and as directed. |
| 27 | Material and Labour for vitrified ceramic tiles 8-10 mm thick dark shade/double charged/ultrachargedarea of each tiles not exceeding 0.42 sqm but not exceeding 1.0 Sqm, of any shade and any pattern (pattern consists combination of two or more tiles ) as in floor etcjointed in neat cement slurry and pointed in colored cement to match colour tiles over and including 15mm thick screed bed in CM 1:6 and pointed in coloured cement to match coloured tiles complete all as specified and as directed.NOTE: No extra cost sahll be allowed for Removing and re-fixing and necessary cutting of door etc if any required during execution of work. |
| 28 | S & F for 10mm thick Vitrified light shade Coloured tiles, square/rectangular double polished, area of each tile n.exc. 0.36 sqm,in floor including 15mm thick screed bed in CM 1:4 etc.,set and jointed in neat cement slurryand pointed in white with pigment to matchfor laying floor finishes all as specified and as directed . |
| 29 | M&L for 8 to 10 mm thick ceramic joint free Coloured Tiles, of size 600x100/150mm, on vertical surface/Skirting over and including 10mm thick rencering in CM 1:4 Laid and Jointed in Neat Cement Slurry and Pointed in white cement with pigment to match the shade of the Tiles, complete all as specified and as directed. |
| 30 | M&L for 18 to 20 mm granite slab of any size for counter top and similar work over and including 15 mm thick screed bed or bedding layer ofcement mortar 1:4 laid and jointed with grey cement slurry mixed with pigment to match the shade of slab including making good the edges complete all as specified and directed by Engr-in-charge. |
| 31 | Rounding of edges of stone slabs one edge such as in steps cooking platforms, and other similar situations complete all as specified and directed by Engineer In Charge |
| 32 | M&L for kota stone slab flooring 20 to 25 mm thick over cement screed bed laid and jointed with grey cement slurry mixed with pigment to match the shade of the stone slab including rubbing and polishing including 20 mm thick screed bed in CM 1:4 complete all as specified and directed. |
| 33 | M&L for precast cement concrete hollow solid blocks exc 10cm widthMasonry type1:3:6 (16 mm using aggregate as per IS 383) set in cement mortar 1:6 all as specified and as directed by engineer in charge |
| 34 | M& L for use and waste of Formwork to sides and soffits of floor or roof beams, beam haunchings,girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc. flat and rough finished surface of concrete. |
| 35 | M&L for RCC1:2:4 type B1 using 20 mm graded aggregate as in concrete for slab supported walls, landing ,canopies and shalfs all as specified and as directed by engineer in charge |
| 36 | M&L for rendering 15mm thick in cement mortar 1:6 on other than fare face of brick work or concrete surfaces and finishing the surface even & smooth without using extra cement on any height complete all as specified and directed by Engr-in-charge. |
| 37 | M&L for rendering 10mm thick in cement mortar 1:3 on other than fare face of brick work or concrete ceiling surfaces and finishing the surface even & smooth without using extra cement on any height complete all as specified and directed by Engr-in-charge. |
| 38 | M&L for applying two coat of Distemper oil emulsion by Auto Roller over a coat of primer over 2 to 3 mm thick birla putty punning including finishing bySanding Machine and Auto Roller new plaster surface wall complete all as specified or as directed by Engineer-in-charge.Make: Asian Paint (Tractor)/Berger paints (Bison super) |
| 39 | M&L for applying two coat of Distemper oil emulsion by Auto Roller over a coat of primer over 2 to 3 mm thick birla putty punning including finishing bySanding Machine and Auto Roller new plaster surface of ceiling complete all as specified or as directed by Engineer-in-charge.Make: Asian Paint (Tractor)/Berger paints (Bison super) |
| 40 | M&L for preparingold distemper and painted surfaces of walls including washing rubbing down andbrooming down smoke soot mould mass and applying one coats of Oil emulsion distemper old surface complete all as specified and directed by Engr-in-charge. |
| 41 | M&L for preparingolddistemper and painted surfaces of ceilingincluding washing rubbing down andbrooming down smoke soot mould mass and applying one coats of Oil emulsion distemper old surface complete all as specified and directed by Engr-in-charge. |
| 42 | M&L for preparing old external plaster surface of walls including washing rubbing down and brooming down mould mass and applying one coat of exterior Acrylic emulsion paint (100% acrylic) of approved colour and shade over a coat of primer and over 1 to 2 mm thick birla putty punning complete all as specified and as directed by Engineer-in-charge. Make-Asian (Apex Ultima) paints/Berger (Whether coat long life) including necessary scaffolding upto 2th floor. |
| 43 | Taking down chowkats or frame with shutter (without taking out shutter from the frame) not exceeding 1.50 Sqm each as doors, windows & ventilators etc. and removal from site complete all as specified and directed by Engr-in-charge. |
| 44 | Taking down door frame with shutter of area exc 1.50 but n exc 4.0 Sqm each and removing to store complete all as specified and as directed. |
| 45 | M&L for 18/19mm thick solid ply wood grade BWR type BB over head rack workfixed with decorative mica with both sides adhesive and nails for working table/storage almirah/doors etc fitted in wall in a any shape and in any direction etc to the required size and desire pattern and colouras specified and directed by EIC |
| 46 | M&L 12mm thick plywood grade BWR type BB fixed with adhesive and nails foralmirah/doors etc fiited in wall in a any shape and in any direction etc to the reuired size and desired pattern and colour as specified and directed by EIC |
| 47 | M&L for 0.9mm thick decorative wooden based mica laminated type-I of surface finish colour pattern as approved fixed with approved adhesive as per manufactures instructions finished to approved site for working table /storage almirah etc and as directed by Engineer In charge |
| 48 | M&L for prelaminatedparticle board 18/19 mm exterior grade prelaminated both side with decorative choice lamination fixed screw to timber or wooden frames as approved pattern complete all as specified and dired by Engineer in charge |
| 49 | M&L for 2nd class hard wood plaincover fillets square rectangular or triangular in section bull nosed spayed chamfered or rounded on one edge or face sectional area exc 06ton, exc 13sqcm approved design complete all as specified and directed by EIC |
| 50 | S&F for cast brass bright polished blank double action/automatic lock and release system box type butt hinges of size 100mm to 125mm long with decorative fancy type complete all as spdecified and directed by EIC |
| 51 | S& Fextrudedbrass polishedbox type decorative door handle of 100mm long desired as approved pattern complete all as specified and directed by EIC |
| 52 | S&F for telescopic channel of size 600mm ( when closed) stainless steel pairs chromium plated roller type heavy duty asper sampleapproved by EIC |
| 53 | S&F for cast brass magnetic door fanlight catch with 14mm catch and fixed of approved pattern conforming to the sample approved by EIC |
| 54 | S&F for 2 levers brass catch for cub board grade I size 50mm complete all as specified and directed by EIC |
| 55 | S&Ffor knobs for cub board fixed in nut screw and washers of brasscomplete all as specified anddirected |
| 56 | Material and Labour for providing dark coloured finish UPVC profile casement Doors profile frame consist of high impact modified grade uPVC of 60mm x 58mm (outer frame) and sashof 60mx78mm, wall thickness of profile must be minimum 1.8± 0.3 mm, which shall be manufactured from tropicalized blend with T Profile and required additives, profile shall be colorfast and conform to standard EN12608, prfile stations shall have multi hollow (min 2 to 3 chabers) chamber to include GI reinforcement with 120 GSM zinc coated, fitted in continuous length, in closed chamber, the thickness of GI shoud be selected to meet the wind load requirement as per IS 875- part-III on sash/mullion and minimum steel steel reinforceent thicknesss of 1.2 mm to 2.5m, UPVC casement Doors/Windows shall be fabricated with fusion welded corners and conform to the strengthrequireents based on wind load as per IS 875-part -III. All hardwarefitted must be stainless steel 3D hinges, handles to be of zinc/Stainless steel, alloy casted Gde 304. Glass shall be of laminated(6T+ 1.23pvb+5T) 5mm thicktoughened glass with weather seal (EPDM/TPE). UPVC casement Doors shall be installed by profile manufacturer only, Fame fastener 8mmx100mm type shall be usedcomplete all specified and as directed by Engineer in charge.Make: Fenesta or equivalent. |
| 57 | Material and Labour for providing dark coloured finish UPVC profile casementwindows (penable) profile frame consist of high impact modified grade uPVC of 60mm x 74mm (outer frame) and sash of 65mx105mm, wall thickness of profile must be minimum 1.8± 0.3 mm, which shall be manufactured from tropicalized blend with T Profile and required additives, profile shall be colorfast and conform to standard EN12608, prfile stations shall have multi hollow (min 2 to 3 chabers) chamber to include GI reinforcement with 120 GSM zinc coated, fitted in continuous length, in closed chamber, the thickness of GI shoud be selected to meet the wind load requirement as per IS 875- part-III on sash/mullion and minimum steel steel reinforceent thicknesss of 1.2 mm to 2.5m, UPVC casement Windows shall be fabricated with fusion welded corners and conform to the strengthrequireents based on wind load as per IS 875-part -III. All hardwarefitted must be stainless steel except handles to be of zinc/Stainless steel, alloy casted Gde 304. Glass shall be of laminated(6T+ 1.23pvb+5T) 8mm thicktoughened glass with weather seal (EPDM/TPE). UPVC casement windows shall be installed by profile manufacturer only, Fame fastener 8mmx100mm type shall be used area exceeding 1.0sqm but not execeeding 2.0sqmeach compete all specified and as directed by Engineer in charge.Make: Fenesta or equivalent. |
| 58 | S&F for powder coated aluminium (min thickness of powder coating 50micron)work for doors and partions with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make confirming to IS ;1285 fixed with dash fasteners of required dia and size ,or with fixing clips or expension hold fasteners for filling of gaps at junctions,i,e at top,bottom and sides with required EPDM rubber/neoprene gasketetc, support the frames including necessary filling up of tc aluminium sections shall be smooth rust free straight mitred and jointed mechanically whatever required including cleat angle,aluminium snap beading for glazing/panellingC.P brass / stainless steel screw, including all necessary hardwarefittings partion/ doors complete all as directed by Engineer in charge |
| 59 | S&F for6mm thick toughtned glass or opeque pane reuired colour and sizeincluding all necessary hardwarefittings partitions,doors /windows complete all as directed by Engineer in charge. Make: saintgobin/modiguard |
| 60 | S&F in repair of aluminium die cast of door closer hydraulically regulated designed No 3 universal type suitable for doorshutter size of 850mm to 1000mm in width weight between from 61 to 80kg and fixed |
| 61 | S&F in repair decorative end Knob for curtain rod 25mm dia fancy type as directed. |
| 62 | S&Fstain less steel Decorative curtain Rod 25mm dia with bracket and fixed in repair |
| 63 | S&F in repairs 250 mm brass sliding door bolt with hasp, staple (Bolt type ) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sectionsandfixed complete all as specified and directed by Engr-in-Charge. |
| 64 | S&F in repair1000 ltrs rotational moulded polyethylene three layered water with EPI coated storage tanks (cylindrical vertical with closed top) hoisted and fixed with all necessary fittings i in position includingtaking down existing water tank of 500 to 1000ltrs or removing of existing RCC old tankcomplete all as specified and directed by Engr-in-charge . |
| 65 | S&F25 mm dia bore ball valves high pressure of PTMT with epoxy coated aluminium rod & high-density plastic ball screwed for iron pipe and fixed complete all as specified and directed by Engr-in-charge. |
| 66 | Taking up or down existing steel tubing/PPR pipe 15 mm bore of any grade and connections including making good the disturbed surfaces complete all as specified and directed by Engr-in-charge. |
| 67 | All as per item66above ,but for 20 mm dia bore |
| 68 | S&F for 20mm dia CPVC SDR 11 pipefixed to concealed/wall, ceilling,laid in floor etc incl all fittings with solvant anf brass threaded fittings for fixing taps etc , including water tighteness test etc., complete all as specified and as directed. |
| 69 | S&F for 25mm dia CPVC SDR 11 pipe fixed to concealed/wall, ceilling, laid in floor etc incl all fittings with solvant and brass threaded fittings for fixing taps etc , including water tightness test complete all as specified and as directed. |
| 70 | S&F in repair 15 mm dia bore CP Bib cock, cast copper alloy, screwed down high pressure with crutch or butterfly handle, screwed both ends for iron pipes or for union and fixed complete all as specified and directed by Engr-in-charge. |
| 71 | S&F in repair PVC connection 15 mm dia and 450 mm long with both end brass fly nutcomplete all as specified and directed by Engr-in-charge. |
| 72 | S&F in repair 32 mm bore of pipe low density (LDPE) of pressure rating 6 Kg per Sqcm fixed to wall or floor etc including fittings complete all as specified and directed by Engr-in-charge. |
| 73 | S&F in repair stain less steeltowel rail of 20 mm dia D type, 60 cm long between flanges complete all as specified and directed by Engr-in-charge. |
| 74 | S&F in repair 100 mm dia cast iron floor trap with grating including jointing to waste pipe in run lead fixed in concrete type B1 1:2:4 completeall as specified anddirected |
| 75 | S&F forglass shelfassembly consist of 5.5mm thick sheet glass shelf 12cm wide with cromium plated bracket guard and railing 60cm fixedl with screws and making good surface of wall complete all as specified and directed by Engr-in-charge. |
| 76 | S&F forbrass chromium plated bottle trap of32mm bore for wash hand basin with inlet and outlet and screwed for pipe or fixed complete all as specified and directed by Engr-in-charge. |
| 77 | Supply only 32mm dia waste fitting brass chromium plated for basin with long screwed shanks and fly nuts, flange end bedded in red lead cement and other end fixed complete all as specified and directed by Engr-in-charge. |
| 78 | S&F for Soap Dish, Single, as Approved, fixing with Brass Chromium Plated Screws including Taking down unserviceable Soap Dish of any description, complete as all specified and directed. |
| 79 | Cuttingfor removingexistingbranch pices drain or pipe of 150mm making good to walling and rendering cutting out branch channel and making good benches completeall as specified and directed. |
| 80 | Supply and fix PVC pipe (SWR) single socketed in any length with rubber ring joint 110mm dia fixed to wall complete all as specified and as directed. |
| 81 | Supply and fix PVC (SWR) bends 110mm with access door complete all as specified and as directed. |
| 82 | Supply and fix in repairs 110mm PVC (SWR) branch piece , single (Single Y) equal or unequal all as specified and as directed. |
| 83 | Supply and fix in repairs 110mm PVC (SWR)Junction , single T (SingleTY) equal or unequal all as specified and as directed. |
| 84 | S&F liquid soap container of PTMT fixed with including chromium plated brass screws and wooden plastic cleats (Min weight 105gms) complete all asspecified and directed |
| 85 | S&F Stainless Steel Kitchen Sink with Drainage Board of Overall Size 915X460mm and Bowl Size 410X330X160mm, made of Stainless Steel 1.0mm thick Sheet with Plugs, Chromium Plated Waste Coupling and Washer including Bedding in Cement Mortar 1:4 to Dwarf Wall or fixing Cantilever Brackets and Connection to Pipe including Taking down unserviceable Sink and Connected Items complete all as specified and as directed by Engr-in-Charge. |
| 86 | M&L fordesigned false ceiling with 12mm thick size 1.2m x 1.80m Pop gypsum board sheets fixed with machine screws as per manufacture instructions and including G I channel 22 guage thick grid work main joints placed at 1.20m centre to centre cross joints placed at 450mm centre to centre, hanging with 22 gauge GI strip suspenders fromroof \"J\" hooks bolts and nuts etc and treating the Gypsum board with thin layer of Gypsumwith gypsum and hydrous binder and prepare the surface till smooth surface is achieved and applying two coat ofoil boud distemper of any patterrn and design over a coat of texture primer on ceilings sheets all complete as required as per manufacture\"s instructions and directed by the EIC1. The pattern and design shall be as directed by Engineer in charge during the execution of work.2. The exposed surface of the false ceiling shall be joint less even and smooth to receive two coats of oil bound distemper3. The Gypsum board (Pop)/sheets shall be fixed with suitable screws below the grid and shall not be placed over the grid. |
| 87 | Ditto as per above item 86 above but incurved surface 10mm thick gypsum board or raised mouldings surfacesof ceiling complete all as specified and directed by Engineer in charge |
| 88 | M & L for point wiring with PVC insulated unsheathed multistranded copper conductor cable 1100 volt grade, FRLS of size 1.5 Sqmm drawn in and including PVC rigid conduit of size not less than 20mm dia with accessories (concealed) including modular metal flush box of suitable size with inner and outer white plastic plate (same make of switch and socket) including continues 1.5 Sqmm copper conductor (multistranded) PVC insulated and unsheathed cable earth wire to common earth and connected to earth dolly complete all as specified conforming to IS-694 for the following:- (a) One light point controlled by one switch 6 Amps |
| 89 | (b) One fan/ exhaust point controlled by one switch 6 Amps |
| 90 | (c ) One 3 pin socket outlet 6 Amps on Independent board |
| 91 | (d) One 3 pin socket outlet 6 Amps on same board |
| 92 | All as per ser item no 88 but here-in before with 4 Sqmm PVC insulated copper conductor incl 4 Sqmm PVC copper conductor used as earth wire for power point /AC point on independent board |
| 93 | Supply and fixing of Modular Switch, one way, 6 Amps complete all as specified and directed |
| 94 | Supply and fixing of Modular Switch socket outlet 3 pin 5 amp flush type 3 module complete all as specified and directed |
| 95 | Supply and fixing of Modular Switch socket combination 16 A, 6 pin, 3 module complete all as specified and directed |
| 96 | Supply and fixing LED strip lights 6 watts,5 metre long strips including suitable drive, 220V, ACwithconnecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete |
| 97 | Supply and fixing LED lights fitting mirror type2\"x 10W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete |
| 98 | Supply and fixing round shape 12 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete. |
| 99 | Supply and fix exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 300m |
| 100 | Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) |
| 101 | Supply and fixing of ceiling rose in poly carbonate 3 plates flush type 6 amps, 250 volts AC complete all as specified and directed. |
| 102 | Taking down ceiling fan, dismantling blades and removing fan to store, Painting of ceiling fans complete, in situ with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust etc. (M & L) including hanging of ceiling fan connectingup incl provn of cable from Ceiling rose to fan cmplete all as directed |
| 103 | Taking down Split AC 1.5 / 2 TR , dismantling copper tubesand removingto store, servicing, topping up refrigerent gas including re fixing the same AC after the completion of civil works connecting up incl provn of cable from socketto ACcomplete all as directed |
| 104 | S&F Fan regulator modular type 02 moduletype250 volts AC complete all as specified and directed. |
| 105 | Supply and fixing MCB SP 6-32 amp rating 240V, 10KA \"C\" curve miniature circuit breaker (MCB) of single pole in the MCB DB complete with connection testing and commissioning complete all specified and directed. |
| 106 | Supply and fixing MCB SPN 40 amp rating 240V, 10KA \"C\" curve miniature circuit breaker (MCB) of single pole in the MCB DB complete with connection testing and commissioning complete all specified and directed. |
| 107 | Supply and fixing sheet metal enclosure distribution board (DB), when MCB to be used, dust and vermin proof, single pole andneutral (SPN) 8 way with 200 Amps rated copper bus bar double door protection, neutral bar, earth bar, single pole and neutral 240 volts, MCBs used as incommer Double door, flush to wall complete all as specified and directed. |
| 108 | Material and labour for submain wiring using two run of sinlge core PVC insulated cable (FRLS) 6 Sqmm copper conductor multi stranded and 6 Sqmm copper conductor insulated cable (FRLS) using as earth wire drawn through and including PVC rigid conduit of size not less than 25mm dia with accessories (concealed) complete all as specified and directed |
| 109 | Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less\"than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion |
| 110 | Schedule of Credit (Minus) Rs.14627.00NOTE: Bidder shall insert credit amount of Rs. 14627.00 as ratein Green field under Col-13. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail