| 1 | Supply Part of 11 kV HT Line |
| 2 | Steel Tubular Poles 9 Mtr |
| 3 | Muffs with concerete filling |
| 4 | Cross Arm: Channel Iron (100×50×6 mm), Length (1270) mm i/c tolerance of 100 mm either side) × 8 structure |
| 5 | Angle Iron (50×50×6 mm), Length: 750 mm × 2 No. × 8 structures |
| 6 | Pole Top Bracket [MSCI: 100×50×6 mm- 100mm] |
| 7 | 11KV Pin Insulators (Porcelain, 12 kV, 10 KN) 3 No. per pole str. |
| 8 | Belt - MS Angle Iron: 50×50×6, Length: 1800 mm × 2 No. |
| 9 | X-Bracing Set - MS Angle Iron: 50×50×6, Length: 2125 mm × 2 No |
| 10 | X-Arm (Horizontal) - MS Channel Iron: 100×50×6, Length: 2340 mm × 2 No. Δ Formation and (for GO Switch & DO Fuse Unit 12 No. also) |
| 11 | Discs Insulator Sets on Dead End Stuctures comprising 1 No. Disc: ^^ (Porcelain, BS, 12kV, 90 KN) including Dead End Clamps etc × (3 No. conductors) × (2 No. sides) |
| 12 | Stay set complete in all respect |
| 13 | Stay Wire (7/3.15 mm) (10.0 Kg Per Stay Set) |
| 14 | HT Earthing Set Complete |
| 15 | Single Continous Earth Wire (G.I. 8 SWG) |
| 16 | Eye Hook for Earth Wire |
| 17 | Angle Iron 50×50×6, Length 2800 mm |
| 18 | Half Clamps |
| 19 | Full Clamps |
| 20 | Danger Plate (250×200×1.6mm) |
| 21 | Nuts and Bolts of various sizes (Galvanised/Coated) |
| 22 | Barbed Wire |
| 23 | Red Oxide |
| 24 | Aluminium Paint |
| 25 | Prov. HP Make AIQ Desktop Model HP 200 G4 with Intell core 5-10110U-12th Gen, Processor |
| 26 | Erection Part of 11 kV HT Line |
| 27 | ACSR 7/3.81 (80mm²) |
| 28 | Steel Tubular Poles 9 Mtr |
| 29 | Muffs with concerete filling |
| 30 | Cross Arm: Channel Iron (100×50×6 mm), Length (1270) mm i/c tolerance of 100 mm either side) × 8 structure |
| 31 | Angle Iron (50×50×6 mm), Length: 750 mm × 2 No. × 8 structures |
| 32 | Pole Top Bracket [MSCI: 100×50×6 mm- 100mm] |
| 33 | 11KV Pin Insulators (Porcelain, 12 kV, 10 KN) 3 No. per pole str. |
| 34 | Belt - MS Angle Iron: 50×50×6, Length: 1800 mm × 2 No. |
| 35 | X-Bracing Set - MS Angle Iron: 50×50×6, Length: 2125 mm × 2 No |
| 36 | X-Arm (Horizontal) - MS Channel Iron: 100×50×6, Length: 2340 mm × 2 No. Δ Formation and (for GO Switch & DO Fuse Unit 12 No. also) |
| 37 | Discs Insulator Sets on Dead End Stuctures comprising 1 No. Disc: ^^ (Porcelain, BS, 12kV, 90 KN) including Dead End Clamps etc × (3 No. conductors) × (2 No. sides) |
| 38 | Stay set complete in all respect |
| 39 | Stay Wire (7/3.15 mm) (10.0 Kg Per Stay Set) |
| 40 | HT Earthing Set Complete |
| 41 | Single Continous Earth Wire (G.I. 8 SWG) |
| 42 | Eye Hook for Earth Wire |
| 43 | Angle Iron 50×50×6, Length 2800 mm |
| 44 | Half Clamps |
| 45 | Full Clamps |
| 46 | Danger Plate (250×200×1.6mm) |
| 47 | Nuts and Bolts of various sizes (Galvanised/Coated) |
| 48 | Barbed Wire |
| 49 | Red Oxide |
| 50 | Aluminium Paint |
| 51 | Tranportation of line material to site of work ( Mechanical Transportation + Manual Transportation) Please Enable Macros to View BoQ information |