| 1 | Demolition of brick work or stone masonry built in cement mortar including all quoins, pillars, arches etc. but excluding ashlar facings, dressed stone work and precast concrete articles, complete all as specified and as directed. |
| 2 | M&L for brick work with sub class ‘B\" bricks of old size,straight or curved on plan exc 6 m mean radius built in cement mortar 1:4 complete all as specified and as directed. |
| 3 | All as per ser Item No 02 above but except brick complete all as specified and as directed |
| 4 | M & L for walling of random rubble stone masonry built in Cement mortar 1:6 uncoursed, well bonded, bedded and solidly hearted and pointing surface in contact with earth in the same mortar, including providing weep holes as the work proceeds complete all as specified and directed. |
| 5 | All as per ser Item No 04 above but except stone complete all as specified and as directed |
| 6 | M & L for providing pre-cast cement concrete type C-1 (1:3:6) (20mm graded aggregate) as in bond stone with solid blocks exc. 10 cm in width and setting in mortar 1:4 complete all as specified and as directed. |
| 7 | Extra over stone walling for hammer dressing to face stones and dressing of face beds and joints, as specified, of random rubble walling, uncoursed or brought upto courses for 40mm granite or trap stone complete all as specified and as directed |
| 8 | M & L for providing flush pointing to random rubble masonry, uncoursed or brought upto courses in cement mortar 1:4 complete all as specified and as directed. |
| 9 | Taking down cement plaster on brick or stone wall etc. including racking out joints, hacking for key and scrubbing down with water etc. complete all as specified and as directed. |
| 10 | M&L for rendering 15mm thick on brick wall or concrete surface in cement mortar 1:4 finished even and smooth without using extra cement complete all as specified and as directed. |
| 11 | M&L for preparation new or old undecorated surface of walls and applying two coats of cement base paint over a coat of alkali resistant primer complete all as specified and as directed. |
| 12 | M&L for preparation of old plastered surface of wall and applying one coats of cement based paint complete all as specified and as directed |
| 13 | Demolition of Concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and as directed. |
| 14 | M&L for 75 mm thick Cement concrete (1:4:8) type B- 2, (40mm graded aggregate) as in sub base complete all as specified and as directed. |
| 15 | M&L sand filling under floor or in foundations including watering and consolidation complete all as specified and directed. |
| 16 | M&L 60mm thick, machine pressed precast concrete interlocking paver block, with grey cement and pigment, any shape and size confirming to IS 15658-2006, M-35 Grade complete all as specified and directed. |
| 17 | M&L 80mm thick, machine pressed precast concrete interlocking paver block, with grey cement and pigment, any shape and size confirming to IS 15658-2006, M-40 Grade complete all as specified and directed. |
| 18 | M & L 15mm thick screed bed or bedding layer in cement mortar 1:4 for laying floor finishes, finished even and fair complete all as specified and as directed. |
| 19 | M&L for chequered cement concrete tiles 20cm X 20cm X 25mm thick, with grey cement and pigments, set, jointed and pointed in neat cement slurry in floors complete all as specified and directed. |
| 20 | M&L for providing cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate as in lintels upto 1.5m clear span, cills, steps and other similar bands, plinth courses, string courses, lacing courses, parapets and railing upto 60cm height, copings, kneelers, apex stone, bed plates and the like including weathering slightly rounded or chamfered angles and throating complete all as specified and directed. |
| 21 | Dismantling of cast iron or reinforced concrete drain pipes, jointed in cement mortar and taking out of trenches, if required complete all as specified and directed. |
| 22 | S & F PVC (SWR) pipes 110 mm bore single socketed, in any length with rubber ring joints laid in trenches or in floor including weep holes etc complete all as specified and directed. |
| 23 | S & F PVC (SWR) bends of 110mm bore complete all as specified and as directed |
| 24 | S & F PVC (SWR) pipes 75mm bore single socketed in any length with rubber ring joints fixed to wallsetc complete all as specified and directed. |
| 25 | S & F PVC (SWR) bends of 110mm bore complete all as specified and as directed. |
| 26 | M&L PCC (1:4:8) type D-2 (using 40 mm graded stone aggregate) as in concrete bed to drain pipes 110mm dia including packing under and haunching against the sides of pipe including excavation, returning, & filling complete all as specified & directed. |
| 27 | M&L for cutting in to existing manholes for connecting new drains, making good to pipe & rendering cutting out existing benching for and forming branch channel in cement concrete1:2:4 type B-1 smooth finished and reforming benching as required for 150 mm bore drain pipe complete all as specified and directed. |
| 28 | Demolition of concrete of any description and in any position not otherwise specifically provided for complete all as specified and as directed. |
| 29 | M&L for PCC 1:2:4 type B 1, using 20 mm graded stone aggregate as surface channels and drains including fair finishing complete all as specified and directed. |
| 30 | Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc complete all as specified and directed. |
| 31 | M & L for providing plain cement concrete type D-2, 1:4:8 (using 40mm graded crushed stone aggregate) as in foundations, filling and mass concrete, complete all as specified and directed. |
| 32 | Dewatering/pumping/bailing out contaminated with waste material sludge from septic tank along with inlet outlet chamber of any capacity/depth by vehicle mounted sewage suction machine and disposing same out of cantonment area in a closed container including taking off manhole cover and putting back the same after cleaning./removing the liquid waste material of septic tanks and cutting hole through slap/ wall where required for inserting pipe and making good the same with cement mortar to match with existing surface to make hygienically fit, writing the date of cleaning of septic tank with black and white paint of size 150x 200 mm and finally spraying unslaked lime (bleaching powder ) dry around and over the septic tank complete all as specified and directed. |
| 33 | Demolition Cement Concrete (reinforced) of any description and in any position not otherwise specifically provided complete all as specified and as directed. |
| 34 | M & L for providing reinforced cement concrete type B-1, 1:2:4 (20mm graded aggregate) (nominal mix) Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and as directed. |
| 35 | M & L for mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed. |
| 36 | M&L for use and waste of formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) complete all as specified and as directed. |
| 37 | M&L 25mm thick PCC 1:2:4 type B-0 using 12.5 mm graded stone aggregate as in levelling course complete all as directed. |
| 38 | Material and labour for 75 mm thick cement concrete type C-2, 1:3:6 ( using 20 mm graded aggregate) as in plinth protectionetclaid in bays including finishing the concrete surface even and smooth without using extra cement complete all as specified and directed. |
| 39 | Material and labour PCC 1:2:4 Type B-1 (using 20mm graded mechanically crushed stone aggregate) as in bonding/locking of edges of interlocking tiles including weathering and slightly rounded or chamferedon edges and threating including necessary form work complete all as specified and as directed. |
| 40 | M&L for 15mm thick rendering on stone masonry surfaces or surface other than fair face of brick-work etc in cement mortar 1:4 complete all as specified and directed. |
| 41 | M&L cement concrete in foundation type C 2, 1:3:6 (40 mm graded stone aggregate) as in filling and mass concrete. |
| 42 | M & L precast cement concrete 1:3:6 type C-1 (using 20 mm graded stone aggregate) as in boulders (for stone walling bond stone) and set in cm 1:4 |
| 43 | Material and labour for providing precast RCC 1:1.5:3 type A-1 using 20mm graded mechanically crushed stone aggregate as in cover slab for man holes, drains, soak well etc and similar articles etc, set in CM 1:4 with plain faces including chamfered weathering throating etc including necessary form work complete all as specified and directed. |
| 44 | Supply and fixing 5 mm dia up to 10 mm dia and over mild steel TMT bars, cut to length, bent to shape required cranking bending and binding with and including mild steel wire annealed not less than 0.90 mm dia. complete all as specified and directed. |
| 45 | Supply and fixing in repairs PVC (SWR) 110mm bore as soil waste and vent pipe single socketed in any length with rubber ring joints fixed to walls complete all as specified and directed. |
| 46 | Supply and fxinigPVC (SWR) bends, Tany radius for 75mm bore pipe complete all as specified and as directed. |
| 47 | Taking down carefully copper/ aluminium unserviceable/ perished point wiring (light, fan, socket or power complete including fixture and fittings such as switches, ceiling roses, pandents, regulators, sockets, light fittings, removing material from site for taking credit etc and making good disturbed surfaces of wall, floors, complete all as specified and directed. |
| 48 | M & L for point wiring with PVC insulated unsheathed single core multistranded copper conductor 1.5 sqmm, 1100 volts grade cable, FRLS, drawn through PVC casing caping/PVC Conduit (As per site requirement) including accessories and provision of PVC boxes for mounting switches, switch socket, fan regulator, provision of modular Teressa plate Irene stripes, No of modules as required on site or as directed by Engineer-in-Charge including one run of PVC insulated unsheathed multistranded copper conductor cable 1.5 sqmm (green colour) earth wire and connected to earth dolly for following. |
| 49 | (a) One light /one fan/one bell point controlled by one switch. |
| 50 | (b) One socket outlet 5 pins 5 amps controlled by one switch on same board. |
| 51 | (c) One socket outlet 5 pins 5 amps controlled by one switch on independent board. |
| 52 | All as per item No 48 herein before but wiring with 2.5 sqmm copper wire (FRLS) and 1.5 sqmm earth wire for socket outlet 6 pin 15 amps on independent board. |
| 53 | S&F switch piano flush button single pole, one way 5 amps complete all as specified and directed. |
| 54 | S&F socket outlet multi 5 pins 5 amp, complete all as specified and directed. |
| 55 | S & F switch socket combination 2 in 1, 5A flush type complete all as specified and directed. |
| 56 | S&F switch piano flush button single pole, one way 15amps complete all as specified and directed. |
| 57 | S&F socket outlet 2 in 1, 6 pins 15 amp,complete all as specified and directed. |
| 58 | S & F switch socket combination 3 pin 16A, flush type complete all as specified and directed. |
| 59 | S&F Modular switch 1 way 6A, 1 module complete all as specified and directed. |
| 60 | S&F Modular switch 1 way 16A, 1 module complete all as specified and directed. |
| 61 | S&F Modular Socket 6A/16A - 2/3 pin combined 2 module, complete all as specified and directed. |
| 62 | S&F ceiling rose, PVC/poly carbonate, isolated body three terminal complete all as specified and directed. |
| 63 | S&F lamp holder angle typePVC/Poly carbonate type insulated body with back plate suitable for batten/wallfitting complete all as specified and directed. |
| 64 | S&F sheet metal enclosure for DBs (Double door type) when MCBs to be used single pole and neutral 4 way including blanking plate as required with 200 amps rated busbar 240V fixed sunk/flush to the wall or niche complete all as specified and directed. |
| 65 | S&F sheet metal enclosure for DBs (Double door type) when MCBs to be used single pole and neutral 8 way including blanking plate as required with 200 amps rated busbar 240V fixed sunk/flush to the wall or niche complete all as specified and directed. |
| 66 | S&F sheet metal enclosure for DBs (Double door type) when MCBs to be used single pole and neutral 12 way including blanking plate as required with 200 amps rated busbar 240V fixed sunk/flush to the wall or niche complete all as specified and directed. |
| 67 | S&F MCB single pole and neutral enclosure with two pin and earth plug and socket complete with one single pole MCB 20 amp complete all as specified and directed. |
| 68 | MCB single pole & neutral 40 to 63 Amps 230 Volts \"C\" series, 10 KA complete all as specified and directed. |
| 69 | S&F MCB\"s single pole 240 volts 6 to 32Amps 10 KA \"C\"series complete all as specified and directed. |
| 70 | M & L for sub main wiring with two single core 6 sqmm PVC insulated and unsheathed 1100 volts grade, stranded copper conductor FRLS ISI marked drawn into & including medium grade PVC conduit/ casing caping25 mm dia with all fittings and accessoriesand one continuous run of 6 sqmm copper conductor PVC insulated (green colour) as earth wire fixed into PVC casing / conduit (not less than 25mm outer dia) with all fittings and accessories fixed concealed/ surfaceincluding taking down old unserviceable submain wiring and making good disturbed surfacecomplete all as specified and directed. |
| 71 | M & L for sub main wiring with two single core 4 sqmm PVC insulated and unsheathed 1100 volts grade, stranded copper conductor (FRLS) ISI marked drawn into & including medium grade PVC conduit/ casing caping25 mm dia with all fittings and accessoriesand one continuous run of 4.00 sqmm copper conductor PVC insulated (green colour) as earth wire fixed into PVC casing / conduit (not less than 25mm outer dia) with all fittings and accessories fixed concealed/ surfaceincluding taking down old unserviceable submain wiring and making good disturbed surfacecomplete all as specified and directed. |
| 72 | Supply and fixing 1100 volts grade heavy duty cable PVC insulated stranded aluminium conductor, served with inner sheathed of PVC tape overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4 mm suspension wire, one twin core cable of size 16 Sqmm complete all as specified and directed |
| 73 | S & F in replacement LED light fitting 1x9W/1X10W bulk head luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed. |
| 74 | Supply and fixing in replacement LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed. |
| 75 | Supply and fixing in replacement LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete. complete all as specified and directed. |
| 76 | Supply and fixing in replacement round shape 6 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed. |
| 77 | Supply and fixing in replacement LED luminaire 600 mm x 600 mm,35/36 watt (as per site requirement), 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed. |
| 78 | S&F Bed side designer lamp, 5 watts, with LED lamp, including all wiring and switches required, with terminal connection, 3 terminal/ PVC/ polycarbonate, isolated body complete all as specified and directed. |
| 79 | Supply and fix in replacement Decorative gate light made up of high grade unbreakable polycarbonate material suitable for retrofit LED 20W B22 base with 1x20 watt LED lamp complete all as specified and directed. |
| 80 | supply and fix in replacement unique LED flood/ focus light 70 W LED 6500 K with IP 65 protection complete all as specified and directed. |
| 81 | Supply and fixing in replacement Exhaust fan AC single phase, 1200 rpm 230/240V of size 250mm sweep with louvre heavy duty complete all as specified and directed. |
| 82 | Supply and fix in replacement, water heater storage type, electric capacity 25 ltr along with all accessories BEE 5 star rated, complete all as specified and directed. |
| 83 | Supply and fix in replacement, water heater storage type, electric capacity 10 ltr along with all accessories BEE 5 star rated, complete all as specified and directed. |
| 84 | M&L for painting of exhaust fans complete, in situ with synthetic enamel paintby spraying including fillingcavitieswithfiller,one coat after cleaning all dust etc. complete all as specified and directed. |
| 85 | M&L for rewinding of exhaust fan with super copper enamelled wire with suitable gauge, varnishing, oiling and greasing of any make of size 450 mm sweep by dismantling its parts, capacitor 4 Mfd by replacing petty items such as nuts & bolts, bearing & washers, cleaning of exhaust fan body and its blade by cleaning agent, assembling,and connectingand testing complete all as specified and directed. |
| 86 | Supply and fixing ball bearing suitable for exhaust fan of any sweep and make complete all as specified and directed. |
| 87 | Supply and fixing gun metal bush suitable for any sweep fan of any make complete all as specified and directed. |
| 88 | Supply and fixing of Capacitor 2.5/3/4 mfd complete all as specified and directed. |
| 89 | Supply and fix in replacement of unserviceable heating element with new one capacity of 1500 Watts (triangle type) for 25 Ltr geysers complete all as specified and directed. |
| 90 | Supply and fix in replacement of unserviceable heating element with new one capacity of 2000 Watts for 25 Ltr geyser (triangle type) complete all as specified and directed. |
| 91 | Supply and fix of unserviceable heating element with new one capacity of 3000 Watts for 225 Ltr geyser complete all as specified and directed. |
| 92 | M&L for repair/replacement of thermostat 7\"\"/9\" suitable for 25/50 ltrs capacity water geyser with automatic thermal cut out including testing complete all as specified and directed. |
| 93 | M&L for repair/replacement of copper Geyser Assembly with rubber packing for 25/50 ltrs capacity water geyser with automatic thermal cut out fixed in repair and including testing, complete all as specified and directed. |
| 94 | S & F and testing of compressor for split type air conditioner of capacity 1.5/2 ton and taking down of unserviceable compressor, complete all as specified and directed. |
| 95 | S & F and testing of thermistor (temperature Sensor) for split type air conditioner of capacity 1.5/2 ton and taking down unserviceable blower complete all as specified and directed. |
| 96 | S & F and testing of PCB for split type air conditioner of capacity 1.5/ 2 ton and taking down unserviceable PCB complete all as specified and directed. |
| 97 | S & F and testing of Blower for split type air conditioner of capacity 1.5/2 ton and taking down unserviceable Blower, complete all as specified and directed. |
| 98 | S & F and testing of transformer for split type air conditioner of capacity 1.5/2 ton and taking down unserviceable blower, complete all as specified and directed. |
| 99 | S & F and testing of out door unit fan blade for split type air conditioner of capacity 2/ 1.5 ton and taking down unserviceable Sensor, complete all as specified and directed. |
| 100 | S & F and testing of outer unit fan of split type air conditioner of capacity 1.5/2 ton and taking down of unserviceable fan, complete all as specified and directed. |
| 101 | S & F and testing of 2 Way Valve assembly of split type air conditioner of capacity 1.5/2 ton and taking down of unserviceablefan, complete all as specified and directed. |
| 102 | Supply and fixing of Capacitor 50 MFD for 1.5 / 2 ton AC complete all as specified and directed. |
| 103 | M&L for repair and replacement unserviceable worn out/ burnt parts of Voltage Stabilizer up to 10 KVA of any make complete all as specified and directed. |
| 104 | Supply and refilling of gas R-22/ R-410/R32/ R134Afor split/ window/ central package type Air conditioners and refrigerators including checking and fixing leakage complete all as specified and directed. |
| 105 | Earthing complete with galvanized steel earth plate electrode 60cmx 60cmx6mmthick buried directly in ground (earth pit not less than 2.25mdeep below normal ground level) with top edge of the plate not less than 1.5mbelow normal ground level, connected to galvanized iron wire 4.0mm diaby means of bolts, nuts and washers of galvanized iron or steel, protected by GI light grade pipe 15mm bore includingGI lightgrade water pipe 20mm dia with funnel all as shown in electric plate No. 03 of 2009 SSR Pt-I and testing on complete including earth work in any type of soil, PCC 1:2:4 type B-0 as in earth pit and cover 40mm thick reinforced with XPM (weight not less than 4.0Kg/Sqm) and frame of angle iron 25x25x3mm with lugs 2 Nos and with 6mm dia MS bar handle made to shape, common salt, charcoal and testing oncompletion, complete all as specified and directed. |