| 1 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group B |
| 2 | Supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 3 | Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed steel/ PVC conduit as required |
| 4 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required. 6 Module |
| 5 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel / PVC conduit as required. |
| 6 | 1x1.5 sq.mm |
| 7 | 2x2.5 sq.mm |
| 8 | 2x4 sq.mm |
| 9 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 10 | 15/16 amp switch |
| 11 | 6 pin 15/16 amp socket outlet |
| 12 | Providing and fixing G.I. pipes complete with G.I. fittings and clamps i/c cutting and making good the same etc. as required at site |
| 13 | 40 mm |
| 14 | 25 mm |
| 15 | Supplying and fixing of gun metal gate valve of folowing size etc. as required at site. |
| 16 | 25 mm |
| 17 | Supplying and fixing of following sizes of medium class PVC conduit /batten along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 18 | 25 mm |
| 19 | 20 mm |
| 20 | Providing and fixing following rating and breaking capacity and pole MCCB in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. 250 Amp, 35 KA,TPMCCB |
| 21 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. |
| 22 | Above 35 sq. mm and upto 95 sq. mm |
| 23 | Upto 35 sq. mm |
| 24 | Supply, installation, testing and commissioning of1400 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Moter, Class of Insulation: B, 3 Nos. Blades, 30 cm long down rod, 2 nos.conopies, shackle kit, safety rope, copper winding, power Factor not less than 0.9, service Value (CMM/W) minimum 6.85, Air Delivery minimum 215 CMM, 350 RPM (Tolerance as per IS:374-2019),THD less than 10%,remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut ,bolts,washers temprature rise= 75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230V, 50 Hz, single phase AC supply, earthing etc. complete as required |
| 25 | Supply, instsallation, testing and commissioning of pre-wired single box type fitting with one no. LEd tube of frosted cover design 18 watts 2100 lm, 50000 burning hours, size 1200 mm complete i/c all accessories etc. directly on ceiling/ wall, including connection with 1.5 sq.mmFRLS PVC insulated copper conductor cable and earthing etc. as required fitting eqivalent to Philips make, CAT No. TMC 502 1xT- LED 22W, Tube eqivalent to Philips make CAT No. MAS LED Tube 1200 mm 18W 865 T8I -2100 lm |
| 26 | Supply, instsallation, testing and commissioning of pre-wired double box type fitting with two no. LED tube of frosted cover design 18 watts 2100 lm, 50000 burning hours, size 1200 mm complete i/c all accessories etc. directly on ceiling/ wall, including connection with 1.5 sq.mmFRLS PVC insulated copper conductor cable and earthing etc. as required fitting eqivalent to Philips make, CAT No. TMC 502 2xT- LED 22W, Tube eqivalent to Philips make CAT No. MAS LED Tube 1200 mm 18W 865 T8I -2100 lm |
| 27 | S/I/T/C of 150 watts flood light fitting 5700K pressured dia cast housing with IP65 protection efficient with 220-240V output emitter LED for better distribution with dimension 447x163x327 mm and 6500 colour with lumens 21500 with all accessories etc. as required at site. (Model No. BVP410 LED 215CW HE NB FG S4 XTFCL) (Philips) |
| 28 | Supplyingof one number PVC insulatedand PVC sheathed /XLPE aluminium armoured conductorpower cable confirming to1.1 KV grade of following size direct in wall etc as reqd. |
| 29 | 4x16 sq.mm |
| 30 | 3.5 x 95 sq.mm |
| 31 | Supplying and fixing of street light pole box of size (250x200x100)complete with all accessories i/c suitable clamps, suitable bakelite sheet, brass screws, washers and 1 Nos. SP MCB 10 amps capacity i/c making connection etc. as required at site. |
| 32 | S/I/T/C of 70 of pre wired, 70 watts, street light luminaire delivering> 100 lumen/ watts with PDC housing , 220-240V, 50 HZ on existing street light pole /wall including all accessories and connection etc. as required. Make Philips, CAT No. BRP032 P LED 75 CW SLR PSU GR SPD or equivalent Model of Thorn/ Trilux/ Philips |
| 33 | Supply, installation, testing and commissioning of pre-wired, 5 watts, IP 65, Post top lantern light have symmetric light distribution 220-240V, 50 Hz complete i/c all accessories etc. directly on surface including connection with 1.5 sqmm FRLS PVC insulated copper conductor cable and erthing etc. as required Make Philips uniscape Model CAT No. BFP 20 LED 45 CW PSU GR CPC SPD or equivalent Model of Thorn/Trilux |
| 34 | Supplying/ fixing / testing and commissioning of 6 watts TRI Glow LED Rope light (72 LED\"s per meter) 108V- 240V, 50HZ having lumens 18000 mm, hight 6.5 mm and weight 11.5 mm strip light for prefect ambience. Colour; Tri colour and waterproof with IP65 rating for superior life and with standing harsh weathr. Flexible, slim & compact and fixing around G.I. pole of size 12 mm hight i/c making connection etc. as required at site. (Model No. 582183) (Philips) |
| 35 | Supply, erection, testing and commissioning of 415V, 3 phase 4 wire 50 Hz, meter panel, IP 65 (outdoor type) fabricated CRCA sheet steel of 2mm thick of frame work and covers, 3mm thick for gland plates i/c cleaning & finishing complete with 7 tank processfor powder coating in approved shade, having capacity /extensible type DMC/ SMC FP bus bars of high conductivity, DMC/ SMC bus bar supports, button base channel of MS section of suitable size fabrication shall be done in transportable sections, entire panel shall have a common copper earth bar of size 25 mm x 5 mm at the rear with 2 Nos. earth sdud, solid connections from main bus bar to switch gears with required size of bus bar etc . complete in all respect as per CPWD specification complete with necessary accessories, wiring with 2.5 sq.mm FRLS insulated copper conductor,cable alleys cable gland and following incoming and outgoing switchgears with protection and metering etc. as required at site. all MCCBs above 63A should be provided with spreader Terminals. Approval shall be taken for each panel before fabrication |
| 36 | Incomer100A FP MCCB (25KA) with thermal magnetic based O/L & S/C protection- 1 Nos. , Incomer should be suitable for cable termination. RYB on , off trip indication lamp-1set, Multi-function Meter with CT-100/5A Class-1.0 10 VA- 03 Nos.Outgoing:1. 63A DP MCB (10kA) – 6 Nos.2. Space for single phase energy meter with lockable arrangement (96x 96mm) :- 6 Nos.Connectingterminal (inside cable alley) of all MCB should be suitable for connection with aluminium armoured cable upto size 16 sq.mm |