| 1 | Dismantling G.S Sheet / FRP Sheet / AC Sheet roofing including ridges, valleys and gutter etc and stacking the material within 50 m lead |
| 2 | Taking out doors, windlows and clear storey openings (steel / wood) shutter including stacking within 100 m lead (only shutters)Of area 3.00 Sq.M and below |
| 3 | Dismantling brick work in Cement mortar carefully without damaging adjacent structures including stacking of materials and dispoal of unserviceable materials within 100 m lead as per direction of Engineer-in-charge. |
| 4 | Dismantling steel work in built up sections in angles, tees, flats and channels including all gusset plates, bolts, nuts, cutting rivets, welding etc. including dismantling and stacking within 100 m lead. |
| 5 | Dismantling plain cement concrete manually / by mechanical means carefully without damaging adjacent structures including disposal of debris within 200 m lead as per direction of Engineer-incharge |
| 6 | Dismantling of RCC works carefully manually without damaging adjacent structures excluding cutting of reinforcement including stacking of steel reinforcement bars and disposal of unserviceable materials within 200 m lead as per direction of Engineer-in-charge. |
| 7 | Extra for cutting of reinforcement in RCC, stacking the same and returning the steel scrap to the departmental stores all as per direction of Engineer-in-charge. |
| 8 | Earth work excavation by mechanical means (Hydraulic excavator) / manual means in all types of soil other than soft and hard rock, dressing the sides of foundation, ramming of bottom etc. including shoring and dewatering (if necessary) and refilling with selected excavated earth in layers of not more than 500 mm thick, each layer well rammed and consolidated including disposing the surplus earth within a distance of 200 m all as per specifications including clearing Jungle, uprooting of vegetation, grass, etc. complete and as directed by the Engineer-in-charge (a) From 0.00 to 1.50 m depth from Average Ground Level |
| 9 | Dismantling Bituminous road including stacking of serviceable materails and disposal of unserviceable materials within 200 m lead. |
| 10 | Supplying, Stacking and Laying of 150 mm thick rubble soling stones as under floor base including packing with smaller stone and compacting, ramming including spreading and consolidation of blinding material, moorum etc. complete all as per specifications and as directed by the Engineer-in-charge. |
| 11 | Providing and laying in position cement concrete of 1:3:6 (1 cement, 3 crushed sand, 6 graded stone aggregate of maximum size 20 mm) including consolidation, finishing, curing etc. complete as per specificationsand drawings but excluding the cost of Form work shuttering, centering Complete at all levels. |
| 12 | Providing and laying in position Reinforced Cement Concrete (RCC) of grade M-30 using 20mm maximum size aggregates and crushed sand of approved quality including admixtures of approved brand and quality (plasticiser or super plasticiser) if required, including weigh batching, mechanical mixing, transporting, placing, vibrating, consolidation, finishing, curing etc. complete but excluding the cost of centering, shuttering and reinforcement complete as per specifications up to Plinth Level.Note :Minimum Cement Contentto be as per the latest revision of the relevant IS Codes. |
| 13 | Extra for RCC Using Ready Mix Concrete from outside project area including transporting and pumping from approved batching plants . |
| 14 | Providing and laying in position cement concrete of 1:1.5:3 at all levels (1 cement, 1.5 crushed sand, 3 graded stone aggregate of nominal size 20 mm) including consolidation, finishing, curing etc.. complete as per specifications and drawings but excluding the cost of shuttering, centering and steel reinforcement. |
| 15 | Providing Reinforcement Steel for reinforced cement concrete Using TMT bars of specified grades all dia bars. TMT bars to be supplied by the contractor manufactured by approved brands as per relevant IS 1786 code at all levels including supplying, preparation of bar bending schedules, cutting, bending, transporting, fixing, tieing in position with PVC coated G.I binding wire, all labour charges, cost of cover blocks in specified grade of concrete etc. complete as per specifications and drawings. Steel supplied by the contractor. |
| 16 | Providing , centering ,shuttering Form work For Sub Structure using PVC film faced plywood to get a neat form finish surface for all types of structures including necessary strutting, proping, staging, supports etc and deshuttering the same after the specified time all as per drawings, specifications and as directed by the Engineer-in-charge at all levels. |
| 17 | Supplying , cutting to shape and fixing 90 mm dia UPVC Pipesas per IS 4985 in RR Masonry/ RCC walls for weep holes complete all as per drawings and as specified at site. |
| 18 | Providing and fixing in position premoulded jointer filler 170mm wide & 12 mm thick in expansion joints. |
| 19 | Providing and laying in position bitumen hot sealing compound for expansin joints using approved make. |
| 20 | Providing Structural steel work using angles, channels, joists and other sections, welded and / or bolted in built up sections for trusses , structural steel floors, frame works, monorails and other structures including supplying, cutting, welding, fabricating, hoisting, fixing in position, applying a priming coat of approved steel primer etc. complete all as per specifications, drawings and as directed by the Engineer in charge. Up to and including 300 mm Joists, 350 mm channels, and below sections using materials produced byapproved manufactures or equivalent meeting all the technical specifications as per relevant IS 2062 codes and standards.All test reports to be provided along with the supply of the materials Notes: 1. The contractor shall supply documentary evidence of purchase of steel, Test certificate from approved manufacturers and also third party testing from approved laboratories with out any extra cost. 2. Welding weights, connections, bolts and nuts shall not be measured for payment but the cost of which shall be deemed to have been included in the rates. 3. Welding Electrodes from approved manufactrers meetinf all the technical specifications (the electrode gives smooth radiographic quality weld with low spatter and smoke) grade only shall be used. 4. Holes to be drilled only by Drilling machines and gas cutting of holes are not permitted. 5. Rate inclusive of all consumables like GAS, welding electrodes and tools and tackles etc. |
| 21 | Providing and Painting two coats of synthetic enamel paint on steel surfaces of approved brand and manufacture to give an even shade over a primer coat.including preparation of the surfaces, scaffolding complete. as per specifications and as directed by the Engineer-in-charge |
| 22 | Providing and constructing Brickwork in cement mortar 1:4 using crushed sand with Flyash / Flyash Lime bricks with minimum 70 kg / Sq. cm strength of approved make and size in Sub structure including, scaffolding, raking out joints, curing, cleaning complete all as per specifications and drawings. |
| 23 | Providing and constructing Brickwork in cement mortar 1:4 using crushed sand with Flyash/ Flyash Lime bricks with minimum 70 kg/ sq.cm strength of approved make and size in super structure up to and including Floor II Level including, scaffolding, raking out joints, curing, cleaning complete all as per specifications and drawings. |
| 24 | Providing and constructing Half brick masonry using Flyash/ Flyash Lime bricks in substructure with minimum 70 kg / Sq.cm strength of approved make and size in partition walls in C.M 1:4 using crushed sand including scaffolding, raking out joints, curing etc. complete and with stiffners of RCC 1:2:4 (105 X 75 mm size) at every 900 mm height including form work curing etc. complete as per specifications but excluding reinforcement. (Reinforcement will be paid under relevant item) |
| 25 | Providing and constructing Half brick masonry using Flyash/ Flyash Lime bricks with minimum 70 kg / Sq.cm strength of approved make and size in partition walls in C.M 1:4 (using crushed sand) including scaffolding, raking out joints, curing etc. complete and with stiffners of RCC 1:2:4 (105 X 75 mm size) at every 900 mm height including form work curing etc. complete as per specifications but excluding reinforcement in Super Structure up to Floor - II level. (Reinforcement will be paid under relevant item) |
| 26 | Providing and fixing precoated Galvalume Roofing profile sheets 0.50mm thickness in single sheet of approved size, shape and pitch up to and including single length of 12.00 met. The sheet shall be fixed using self drilling / self tapping screws of size (5.5 X 55 mm) with EPDM seal or with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers filled with white lead complete upto any pitch in horizontal / vertical or curved surfaces excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required as directed by the Engineer-incharge |
| 27 | Providing 15 mm thick Internal plaster in cement mortar 1:4 without cement punning (using Crushed Sand) finished smooth, including sieving of sand to required fineness, preparation of the surface, scaffolding, curing all as per specifications, drawings and as directed at site complete. |
| 28 | Providing 20 mm thick water proof plastering in cement mortar 1:3 (using crushed sand) finsihed smooth with a floating coat of neat cement including approved water proofing compound added @ 2% by weight of cement or as per manufacturer\"s specifications, sieving of sand to required fineness, preparation of surface, scaffolding at all heights, curing all as per specifications, drawings and as directed at site. |
| 29 | Providing 15 mm thick Internal plaster in cement mortar 1:4 with cement punning (using Crushed Sand) finished smooth, including sieving of sand to required fineness, preparation of the surface, scaffolding, curing all as per specifications, drawings and as directed at site complete. |
| 30 | Providing and fixing 1st quality antiskid ceramic glazed floor tiles of minimum 300 - 600 mm long and 300 - 600 mm wide and thickness not less than 6 mm conforming to IS 15622 of approved make in all colours and shades as approved by Engineer-incharge over a bed of 20 mm thick bed of cement mortar 1:4 (using crushed sand) and jointing with grey cement slurry including pointing with white cement based Tile grout of approved make and matching shade complete as per patterns, drawings and specifications complete as directed by the Enginner-in-charge. |
| 31 | Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS 15622 of approved make. shade and colour of size ranging from 300 - 600 mm long and 300 mm - 600 mm wide and thickness not less than 6 mm as approved by Engineer-in-charge in skirting, risers of steps and dados over 12 mm thick bed of cement mortar 1:3 (using crushed sand), setting the tiles in cement slurry and pointing the joints with matching colour Tile grout of approved make of matching shade including using PVC tile trim in the exposed corners, complete as per drawings, patterns and specifications complete as directed by the Engineer-in-charge. |
| 32 | Providing and fixing Minimum 15-17 mm thick gang saw cut mirror polished (premoulded and prepolished) machine cut Granite of Telephone Black colour for kitchen platforms, vanitiy counters, Wash basin Counters, Door Frames, window sills, facias and similar locations of required size, colour and texture laid over 20 mm thick base cement mortar 1:4 (using crushed sand) with joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing the edges to give high gloss finish etc. complete as directed by the Engineer-in-charge at all levels |
| 33 | Extra for providing edge moulding to 15-17 mm thickGranite Slab counters, Vanitis etc. including machine polishing to edge to give high gloss finish et. Complete as per design approved by Engineer-in-charge. |
| 34 | Providing and fixing 35 mm thick panelled door type FRP door shutterswith plain colour or wooden veneer finish of approved make & approved design & colour. made out of 1.5 mm thick FRP skin moulded over wooden frame work of 40 mm wide and required thickness wooden styles and minimum 100 mm wide lock rails and wooden blocks for door stoppers, tower bolts, baby latch, aldrop, handles etc. wherever required and core filled with Polyurethane Foam and fixing with 4 Nos 100 mm (ISI marked) stainless steel hinges with S.S. wood screws. including the cost of 100 mm ISI marked heavy quality stainless steel butt hinges with necessary screws. |
| 35 | Providing and fixing White Vitreous china Orissa pattern W.C. pan of size 580x440 mm of apperoved make with 100 mm China ware P or S trap, One no. 10 litre High level or low level white PVC flushing cistern with flush pipe & bend with manually controlled device (handle lever) conforming to IS:7231, PVC 15 mm Inlet connection with all fittings and fixtures complete including all connection, embedding in position commissioning, cleaning etc. all as per drawings and specifications and as directed by the Engineer-in-charge. |
| 36 | Providing and fixingWhite vitreous China wash basin ofsize 550 x 400 mm/ 550 x 420 mm and equivalent sizes with single 15 mm C.P. brass pillar tap of approved make and colour with C.I. brackets, 15 m C.P. brass pillar tap of approved make,15 mm x 600mm long PVC Inlet connection, 32 mm heavy quality C.P. brass waste coupling of standard pattern, including painting of fittings and brackets, cutting and making good the walls and testing complete all as per specifications and as directed by the Engineer-in-charge |
| 37 | Providing and fixing white vitreous china flat back half stall urinal size 580x380x350 mm / 610 mm of approved make Aquaseal model with Push cock of approved make,with CP brass flush pipe unions, heavy quality C.P. brass spreaders, C.P waste coupling with dome grating, clamps complete all as per specifications drawings and as directed by the Engineer-in-charge. |
| 38 | Providing and fixing anodised aluminium baby latch of size 75 X 12 mm ISI marked of approved make transparent or dyed to requried colour or shade with necessary screws etc. |
| 39 | Providing and fixing aluminium handles 175 mm long Inner grip 125 mm with 12 mm dia rod plate type BOW handles ISI marked of approved make, anodised transparent or dyed to req. colour or shade with necessary screws etc. complete. |
| 40 | Providing and fixing 6 mm thick mirrors of size 600 x 450 mm of approved make with bevelled edges complete with 6 mm thick asbestos sheet back ground fixed to walls with C.P. brass screws and concealed washers complete. all as per specifications and as directed by the Engineer-in-charge . |
| 41 | Providing and fixing Heavy quality 32 mm diaPVC (semi-rigid) waste pipeof approved make for sink or wash basin including PVC waste fittings etc. complete all as per specifications and as directed by the Engineer-in-charge |
| 42 | Providing and fixing C.P brass 15 mm dia bib cock fancy variety quarter turn of approved type and make of heavy quality of specified / approved make as per specifications and as directed by the Engineer-in-charge |
| 43 | Providing and fixing 15 mm n.b CP brass Angle cockquarter turn ofheavy quality of specified / approved make, for wash basin inlet / flush cistern etc. as per specifications and as directed by the Engineer-in-charge. |
| 44 | Providing and fixing heavy quality CP brass bottle trap 31 / 32 mm of approved make single piece moulded with height of 270mm, effective length of tail pipe 260 mm from the centre of the waste coupling 77 mm breadth with 25 mm minimum water seal,of approved make for wash basins / urinal etc all as per specifications and directed by the Engineer in charge. |
| 45 | Providing and fixing C.P brass towel rail of approved make 600 mm long complete fixed to walls with 30 mm CP brass screws with concealed fitting arrangement all as directed by the Engineer-incharge. |
| 46 | Providing, laying , jointing, fixing and testing heavy quality ( (ISI Marked C-Class) Galvanised Iron pipes and ISI marked fittings like, tees, elbows, bends, unions, nipples,reducers etc. as required for the work, including testing the pipes and fittings for 10.00 Kg / Sq.Cm hydralic pressure with a minimum period of two hours duration with clean water, including cutting , threading, jointing with hemp yarn, white lead, jointing teflon tape, chasing walls and making good by filling with concrete 1:3:6, complete all as per specifications and drawings, including two coats of anti corrosive bitumastic paint, all as directed by the Engineer-in-charge. Pipes with ISI marked \"C\" -Class heavy quality pipes of approved make. |
| 47 | 15 mm dia G.I pipe |
| 48 | 20 mm dia G.I pipe |
| 49 | Providing and fixing C.P Brass open stop cock of Heavy Quality of specified / approved make as per specifications and as directed by the Engineer-in-charge |
| 50 | 15 mm n.b CP Brass open stop cock of approved make and type |
| 51 | 20 mm n.b CP brass open stop cock of approved make and type |
| 52 | Providing and fixing cast iron nahani trap / floor trap of 100 mm inlet and 75 mm outlet, (weighing 5.80 Kg each), jointing with lead with the connection pipes, placing as per the drawings, embedding in cement concrete 1:2: 4 and making circular hole up to floor level using 110 mm O/D PVC pipes of 6 Kg / sq.cm pressure and fixing 1 No 125 mm dia C. P brass grating , complete all as specifications and drawings and as directed by the Engineer-incharge. |
| 53 | Providing and fixing SS grating 125 mm dia heavy quality stainless steel / C.P brass grating of approved equvalent make as specified for floor traps / nahani traps all as directed by the Engineer-in-charge |
| 54 | Providing and fixing 150 x 100 mm size gully trap \"P\" type square mouth S.W. gully trap complete with CI grating brick masonry chamber with water tight CI cover with frame of 300 x 300 mm size (inside) the weight of cover to be not less than 4.5 kg and frame to be not less than 2.70 kg as per standard design. |
| 55 | Supplying and fixing Cast Iron Man hole or Cast Iron Steps cover of approved make and weight as specified in the drawings or as directed by the Engineer in charge. |
| 56 | Providing, supplying, fixing in position, under floors or in walls centrifugally cast iron pipes including required specials like bends, tees, \"Y\" collars, cowl etc for soil, waste and ventilation pipes conforming to IS.3989 or Cast Iron hubless pipes confirming to IS 15905 of approved make including cost of jointing with spun yarn and molten lead of specified quantity, caulking the joints, including testing of pipes, painting with primer, fixing at walls with necessary approved type of clamps and brackets complete all as per drawings and specifications and as directed at site. |
| 57 | 75 mm dia centrifugally cast (spun) iron socketed pipe as per IS:3989 using 0.90 kg lead / joint or Cast Iron hubless pipes confirming to IS 15905 |
| 58 | 100 mm dia centrifugally cast (spun) iron socketed pipe as per IS:3989 using 1.00 kg lead / joint or Cast Iron hubless pipes confirming to IS 15905 |
| 59 | Providing and fixing75 mm Dia C.I cowl as per IS 3989terminal guards (slotted C.I cowls) for the following Dia of C.I Pipes as directed by the Engineer-in-charge |
| 60 | Providing, laying 150 mm diameter stoneware pipe to the slope specified and jointing glazed stoneware pipes grade \"A\" with stiff mixture of cement mortar in the order of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete excluding excavation and refilling which will be paid under relevent Item |
| 61 | Providing and fixing PVCSWR PIPE 110 mm O/D rain water pipes conforming to relevant IS type B and PVC SWR fittings & specials conforming to relevant IS including jointing with seal ring / With PVC solvent adhesive including fixing in walls using clamps etc complete all as per drawings, specifications and as directed by the Engineer-in-charge. |
| 62 | Providing and fixing glazing With frosted glass panes of 5.00 mm thicknessin aluminium doors, window, ventilator shutters and partitions etc with PVC / Neoprene gasket etc. complete as per the architectural drawings and directions of the Engineer-in-charge (Cost of snap beading shall be paid in basic item) |
| 63 | Providing and applying wall painting two coats on new work with premium plastic emulsion paint of approved brand to give an even shade, including a coat of approved cement primer, including preparation of the surfaces, scaffolding complete. as per specifications and as directed by the Engineer-in-charge |
| 64 | Providing , painting and finishing walls with two coats of exterior emulusion paint of approved make on sand face plaster/ plain plaster & concrete of required shade over new work including base coat of water proofing cement paint, preparation of the surfaces, scaffolding complete. as per specifications and as directed by the Engineer-in-charge. |
| 65 | Providing, fabricating, erecting & in position CRIMPNET GATE with G.I. tubular frames, 50mm x 8 g G.I. crimpnet welded onM.S. pipes with angle iron frame, m.s. flat beadingto hold crimpnet, m.s. channel supports incluidng pivot type hinges, locking arrangements, tower bolts, embedding channel posts in cement concrete 1:3:6 , scaffolding for erectingand painting the gate & all steel work with two coats of approved paint over a coat of primer etc. complete generally as per specifications & drawings.cost of excavation, PCC, formworkshall be paid seperately and MS angle, Channel & M.S. Pipe shall be paid instructural steel relevant item. |
| 66 | Supplying & fixing in position 50 mm x 8 gauge G.I. CRIMPNET welded to pipes with angle iron frame, m.s. flat beading to hold CRIMPNET including scaffolding all material & labour etc. complete as per specifications. |
| 67 | Providing G.I.Pipes medium variety (Class B) for CRIMPNET GATE etc. includding cutting of pipes as required, bending & welding including painting with two coat of synthetic enamel paint over a coat of steel primer etc complete |