| 1 | M&L for \"B\" check means taking out old unserviceable engine oil from oil sump by openeing the drain plug and well cleaning the oil sump, taking out oil filter, bypass filter and diesel filter (primary and secondary) and replacement the same with new as follows for DG Set\"s of capacity of 20 KVA to 40KVA complete all as specified and directed. Note : (a) Spare parts shall be measured and paid separately under respective item of Sch \"A\". (b) Labour charges for dismantling/taking down and replacement/fixing new parts as and when required deems to be incl. in the quoted rates |
| 2 | Supply only fuel filter element with \"O\" ring |
| 3 | Supply only Lubricating Oil filter element with \"O\" ring. |
| 4 | Supply only Hose pipe, including nut, bolts and clamps |
| 5 | Supply only\"V\" belt cogged type make Fenner/good |
| 6 | Supply onlyAir filter element inner & outter |
| 7 | Supply only Oil bypass filter element with \"O\" ring |
| 8 | Supply only fuel water seprater |
| 9 | M&L for \"B\" check means taking out old unserviceable engine oil from oil sump by openeing the drain plug and well cleaning the oil sump, taking out oil filter, bypass filter and diesel filter (primary and secondary) and replacement the same with new as follows for DG Set\"s of capacity of 50 KVA to 62.5KVA complete all as specified and directed. Note : (a) Spare parts shall be measured and paid separately under respective item of Sch \"A\". (b) Labour charges for dismantling/taking down and replacement/fixing new parts as and when required deems to be incl. in the quoted rates |
| 10 | Supply only fuel filter element with \"O\" ring |
| 11 | Supply only Lubricating Oil filter element with \"O\" ring. |
| 12 | Supply only Hose pipe, including nut, bolts and clamps |
| 13 | Supply only\"V\" belt cogged type make Fenner/good |
| 14 | Supply onlyAir filter element inner & outter |
| 15 | Supply only Oil bypass filter element with \"O\" ring |
| 16 | Supply only fuel water seprater |
| 17 | M&L for \"B\" check means taking out old unserviceable engine oil from oil sump by openeing the drain plug and well cleaning the oil sump, taking out oil filter, bypass filter and diesel filter (primary and secondary) and replacement the same with new as follows for DG Set\"s of capacity of 100 KVA to 125KVA complete all as specified and directed. Note : (a) Spare parts shall be measured and paid separately under respective item of Sch \"A\". (b) Labour charges for dismantling/taking down and replacement/fixing new parts as and when required deems to be incl. in the quoted rates |
| 18 | Supply only fuel filter element with \"O\" ring |
| 19 | Supply only Lubricating Oil filter element with \"O\" ring. |
| 20 | Supply only Hose pipe, including nut, bolts and clamps |
| 21 | Supply only\"V\" belt cogged type make Fenner/good |
| 22 | Supply onlyAir filter element inner & outter |
| 23 | Supply only Oil bypass filter element with \"O\" ring |
| 24 | Supply only fuel water seprater |
| 25 | M&L for \"B\" check means taking out old unserviceable engine oil from oil sump by openeing the drain plug and well cleaning the oil sump, taking out oil filter, bypass filter and diesel filter (primary and secondary) and replacement the same with new as follows for DG Set\"s of capacity of 250KVA complete all as specified and directed. Note : (a) Spare parts shall be measured and paid separately under respective item of Sch \"A\". (b) Labour charges for dismantling/taking down and replacement/fixing new parts as and when required deems to be incl. in the quoted rates |
| 26 | Supply only fuel filter element with \"O\" ring |
| 27 | Supply only Lubricating Oil filter element with \"O\" ring. |
| 28 | Supply only Hose pipe, including nut, bolts and clamps |
| 29 | Supply only\"V\" belt cogged type make Fenner/good |
| 30 | Supply onlyAir filter element inner & outter |
| 31 | Supply only Oil bypass filter element with \"O\" ring |
| 32 | Supply only fuel water seprater |
| 33 | Supply and filling in renewal or in topping up engine oil SAE grade 20W-40 for DG Set of capacity 20 to 250 KVA complete all as specified and directed |
| 34 | M&L for Disconnecting, removing and dismantling water radiator assembly from DG Set of 25 KVA to 100 KVA DG set and descaling the radiator thoroughly with radiator cleaner solution / any other chemical solvent agent including stopping of leakage at place to copper cores and tubes by brazing, with suitable copper brazing rod and refixing back to its original possing complete all as specified and as directed. |
| 35 | All as per item No 06 above but for DG set of capacity 125 KVA to 250 KVA complete all as specified and directed. |
| 36 | Supply and filling in renewal or in topping distilled water for mixing with coolent as recommended ratio or topping in radiator complete all as specified and directed. |
| 37 | Supply and filling in renewal or in topping inhabitor non corrossive coolent mixed with distilled water as recommended ratio complete all as specified and directed. |
| 38 | M&L for Taking out unserviceable AVR from DG set and replace with the new AVR (Automatic Voltage Regulator) of the exising make of generator of capacity 125 KVA to 250 KVA, complete all as specified and directed. |
| 39 | All as per item No 10 above but of 20 KVA to 100 KVA complete all as specified and directed. |
| 40 | M&L for Taking out unserviceable self starter from DG set including repair & overhauling the self starter assy 12/24 volts of capacity 125 KVA to 250 KVA after spliting the assembly including cleaning and rewininding armature and stator assembly with super enamelled copper winding wire of existing size & insulating the field coil assy and fixing back to its original position and testing complete all as specified and directed. |
| 41 | All as per item No 12 above but of 20 KVA to 100 KVA complete all as specified and directed. |
| 42 | M&L for replacement of battery terminal positive & negative made of brass with necessary brazing to cable complete all as specified and directed. |
| 43 | M&Lfor replacement of battery cable of 70 Sqmm PVC insulated multi stranded copper conductor singlecore cable with necessary copper lugs complete all as specified and directed. |
| 44 | Taking out unserviceable dynamo 12 volt from any capacity of DG SET, fromthe exisintg position, dismantling the same and repairing by turning of commutator replacing the armature, carbon brush varnishing the coil assembling and other parts to make serviceable and refixing back to its original in position and testingcomplete all as specified and directed. |
| 45 | M&L for repair of U/S UPS including repair /replacement of U/S inverter card ,PFC board,SMPS board ,rewiring,PCB board ,and any other part required for smooth functioning of UPS complete all as specified and directed. |
| 46 | M&L for taking down U/S battery from UPS and supply and installation of sealed lead acid battery of 12V 42 AH of minium 3 year warranty complete all as specified and directed. |
| 47 | M&L for Taking down PT pump from engine, over hauling & calibiration at workshop, and clean with cleaning agent including replacement of defective parts by new partsreinstallation,and testing complete. for 125KVA to 250 KVA complete all as specified and directed.Note : (a) Spare parts shall be measured and paid separately under respective item of Sch \"A\". (b) Labour charges for dismantling/taking down and replacement/fixing new parts as and when required deems to be incl. in the quoted rates |
| 48 | Supply only gasket set complete all as specified and directed |
| 49 | Supply only techo shaft assembly complete all as specified and directed |
| 50 | Supply only throttle shaftcomplete all as specified and directed |
| 51 | Supply only gear pump complete all as specified and directed |
| 52 | Supply only berral & sleeves complete all as specified and directed |
| 53 | Supply only governer plunger complete all as specified and directed |
| 54 | Supply only shut down valve assymbly complete all as specified and directed |
| 55 | M&L for Taking down of FIP from engine,repair overhaulling,calibration and testing of fuel pump of 20 KVA to 100 KVA capacity DG set including replacement of defective parts , and adjustment of injectors and setting of fuel pressure complete all as specified and as directed.Note : (a) Spare parts shall be measured and paid separately under respective item of Sch \"A\". (b) Labour charges for dismantling/taking down and replacement/fixing new parts as and when required deems to be incl. in the quoted rates |
| 56 | Supply only delivery valve complete all as specified and directed |
| 57 | Supply only roller complete all as specified and directed |
| 58 | Supply only rocker asssambly complete all as specified and directed |
| 59 | Supply only element complete all as specified and directed |
| 60 | Supply only FIP gasket set complete all as specified and directed |
| 61 | Supply only injector cup set complete all as specified and directed |
| 62 | Supply only barrel plunger complete all as specified and directed |
| 63 | Supply only \"O\" ring set complete all as specified and directed |
| 64 | M&L for Taking down turbo charger assembly of 125 KVA to 250 KVA DG set Repair / over hauling including replacement of defective parts by new parts ,reinstallation,and testingfor 250 KVA DG Set complete all as specified and directed. Note : (a) Spare parts shall be measured and paid separately under respective item of Sch \"A\". (b) Labour charges for dismantling/taking down and replacement/fixing new parts as and when required deems to be incl. in the quoted rates |
| 65 | Supply only Turbo repair kit complete all as specified and directed |
| 66 | Supply onlyTurbine wheel & shaft complete all as specified and directed |
| 67 | Supply only compressor wheel complete all as specified and directed |
| 68 | M&L for Taking down of AC alternatorfrom DG sets of capacity 20 KVA to 100 KVA after disconnecting all electrical connections, cleaning of winding with emery paper of armature and filled coils and rewininding armature and stator assembly with super enamelled copper winding wire of existing size & insulating the field coil assy including transportation of alternator to workshop and bringing it back to site for re-installation and reconnecting alternator with engine including testing on load complete all as specified and as directed including repairing of following worn out spare parts : -(i)Carbon bushing and brush holder (set of 08) - 01 Set.(ii) Suitable size and capacity of bearing - 01 Set. |
| 69 | All as per item No 22 above but of 125 KVA to 250 KVA complete all as specified and directed. |
| 70 | M &L for reconditioning of unserviceable battery 12 volt, 120 to 180 Ah by replacing complete cells, PVC saperaters, electrolyte, terminals & final sealing, recharging and testing complete all as specified and directed. |
| 71 | Supply and fixing in replacement of U/S battery with new 12 volts 150 AH lead acid tubular battery complete all as specified and directed. Make-Exide / Amron / Livefast / Liuminous |
| 72 | Supply and fixing in replacement of U/S battery with new 12 volts 180 AH lead acid tubular battery complete all as specified and directed. Make-Exide / Amron / Livefast / Liuminous |
| 73 | Supply and fixing in replacement of U/S battery with new 12 volts 48 AH lead acid maintenance free battery complete all as specified and directed. Make-Exide / Amron / Livefast / Liuminous |
| 74 | Supply and fixing in replacement of U/S battery with new 12 volts 110 AH lead acid maintenance free battery complete all as specified and directed. Make-Exide / Amron / Livefast / Liuminous |
| 75 | Supply & fixingin replacementshut down valve assymbly complete all as specified and directed. |
| 76 | Supply & fixingvaccume indicator complete all as specified and directed. |
| 77 | Supply & fixingrubber hose cooler any size complete all as specified and directed. |
| 78 | Supply & fixing Hose rubber for radiatorany size complete all as specified and directed. |
| 79 | Supply & fixing fuel pipe from tank to filter with all fittings complete all as specified and directed. |
| 80 | Supply & fixingfuel pipe from filter to pump assymbly with all fittings complete all as specified and directed. |
| 81 | Supply & fixing water pump assembly suitable for 62.5 KVA to 250 KVA DG Set complete all as specified and directed. |
| 82 | Supply and fix in replacement \"ON LOAD\" change over switch 415V in sheet metal enclosures 4 pole of capacity 63 Amps with sidehandle operated complete all as specified and as directed. |
| 83 | All as per item No 36 above but of capacity 100 Amps complete all as specified and directed. |
| 84 | All as per item No 36 above but of capacity 250 Amps complete all as specified and directed. |
| 85 | All as per item No 36 above but of capacity 400 Amps complete all as specified and directed. |
| 86 | Supplying and laying in replacement synthetic Rubber insulated mats 2.0 mm thick for voltage upto 3.3 kv for electrical suitable for electrical shock safety of sizes 2m x 1m. complete all as specified and directed. |
| 87 | Supply, Installed & fix maintenance free earthing copper bonded steel earth rod of 10 feet long having diameter of 17.2mm with copper bonding thickness of 250 micron,UL listed,CPRI Tested at 25 KA fault current for one second and is provided with universal clamp made of SS earth enhancing compound shall be of 50kg/pit(resistivity is less than 0.12 Ohm meter). The above arrangements shall be provided with heavy duty earth poly plastic pit cover of 4000 kg load bearing capacity (Size:270 x 240 x 200mm) andFRLS insulated copper conductor of size 6 sqmm, single core cable drawn through and including medium grade rigid PVC conduit upto 7 mtr incl cutting and chases on wall / floor and making good using PCC work complete all as specified and directed. |
| 88 | M&L for Disconnecting carefully old unserviceable ammeter from panel board and S&F of new 96mm size square/circular digital type ammeter of range 0-30 ampere or 0-300 Ampere, size of letters 25mm, with set of CTs of suitable rating, necessary connecting/fixing arrangements and testing complete all as specified and directed. |
| 89 | M&L for Disconnecting carefully old unserviceable Voltmeter from panel board an S&F of new 96 mm size square/circular digital type Voltmeter of range 0-500 Volt,size of letters 25mm, make -AE (ISI marked), necessary connecting/fixing arrangements and testing complete all as specified and directed |
| 90 | S&F as in replacement of LED type indicating lamps of RYB colours as directed at site on existing panel board including necessary fixing and connecting arrangements complete all as specified and directed |
| 91 | M & L for fire extinguishers of capacity 9 Kg foam typecomplete all as specified and directed. |
| 92 | M & L for fire extinguishers of capacity 5 Kg ABC typecomplete all as specified and directed. |
| 93 | M & L for fire extinguishers of capacity 2 Kg ABC typecomplete all as specified and directed. |
| 94 | S&F in replacement of glow sign board box type of size 100 cm x 200cm made of flexy cover in blue and maroon bordering colour all around the flex board in rectangular form, blue background with MES logo on the centre with the stencil of word, font size as directed by Engr-in-Charge.One side of the board will display and the other side is made of GI Sheet with MS angle frame not less than 40x40x6mm, 02 x LED tube light fittings complete including connecting up with twin core twisted flexible copper conductor cable with suitable size and necessary items for fixing on roof of Pump House & Power House, with all grouting and PCC work complete all as specified and as directed |
| 95 | Supply only pair of class 2 electrical hand gloves HT 11 KV complete conforming to IS :4770/1991,complete all as specified and directed. |
| 96 | Supplying and fixing in repairs asbestos rope 12 mm dia wound over exhaust pipe of DG set of any capacitycomplete all as specified and directed. |
| 97 | Supply, installation, testing & commissioning for Moving Bed Bio Reactor (MBBR), Fluidised Aerobic Bio Reactor (FAB) synthectic media MOC PP virgin, Surface area 450 m2/m3 complete all as specified and directed. |
| 98 | M&L for Taking down Blower of any make and capacity installed at STP including adjustment of lobes and covers and replacement of defective parts by new parts, reinstallation, and testing complete all as specified and directed. Note : (a) Spare parts shall be measured and paid separately under respective item of Sch \"A\". (b) Labour charges for dismantling/taking down and replacement/fixing new parts as and when required deems to be incl. in the quoted rates |
| 99 | Lubricating oil filter |
| 100 | Radiator hose pipe |
| 101 | Fan belt |
| 102 | Carbon brush |
| 103 | M&L for Taking down Gear Box installed at STP including adjustment of lobes and covers and replacement of defective parts by new parts, reinstallation, and testing complete all as specified and directed. Note : (a) Spare parts shall be measured and paid separately under respective item of Sch \"A\". (b) Labour charges for dismantling/taking down and replacement/fixing new parts as and when required deems to be incl. in the quoted rates |
| 104 | Fan belt |
| 105 | Carbon brush |
| 106 | M&L for Gear oil of suitable grade for Kay blower complete all as specified and directed |
| 107 | M&L for scheduled maintanence and servicing of all electro - mechanical machinery/panel of existing non clog submersible( lifting and lowering the pump and remove all blockage items), also rectifying delivery side pipe line or leakagewhen ordered including cleaning it\"s part, removing corrosion, refixing it, rectifying leakage or block of pump due toplastics & cotton / loose nut / stud/ gland packing/gland rope/ star packing/ clamps/washersetc of suitable size as required. Details of maintenace should be recorded in registercomplete all as specified and directed . |
| 108 | S&F in replacement of following spare parts suitable for existing starter panels as required:- |
| 109 | S&F MNX 110 coil 3 pole contactor 110 amp.all as specified and directed |
| 110 | S&F MNX 80 coil 3 pole contactor 80 amp.all as specified and directed |
| 111 | S&F MNX 70 coil 3 pole contactor 70 amp.all as specified and directed |
| 112 | S&F MNX 40 coil 3 pole contactor 40 amp.all as specified and directed |
| 113 | S&F MNX 32 coil 3 pole contactor 32 amp.all as specified and directed |
| 114 | S&F MNX 25 coil 3 pole contactor 25 amp.all as specified and directed |
| 115 | S&F MNX 18 coil 3 pole contactor 18 amp.all as specified and directed |
| 116 | S&F MNX 12 coil 3 pole contactor 12 amp.all as specified and directed |
| 117 | S&F Contactor 3Phase, 3Pole, 63A all as specified and directed.Make: TC Cat No: LC1 D633 or equivalent in make of Simens/ L&T/ Havells |
| 118 | S&F Contactor 240V, 3Pole, 50A all as specified and directed.Make: HPL Cat No: IC50 or equivalent in make of Simens/ L&T/ Havells |
| 119 | S&F Auxiliary Contactor MNX 9-80 all as specified and directedMake: L&T Cat No:CS94118 or equivalent in make of Simens/ L&T/ Havells |
| 120 | S&F MN 5 Thermal Over Load Relay 45-75A all as specified and directed. |
| 121 | S&F MN 5 Thermal Over Load Relay 9-15A all as specified and directed. |
| 122 | S&F Thermal Over Load Relay 7-10A all as specified and directed. Make: TC Model No: TR2D09314 or equvalent in make of Simens/ C&S/ L&T |
| 123 | S&F Thermal Over Load Relay 12-18A all as specified and directed. Make: TC Model No: TR2D18321 or equvalent in make of Simens/ C&S/ L&T |
| 124 | S&F Thermal Over Load Relay 17-25A all as specified and directed. Make: TC Model No: TR2D3522 or equvalent in make of Simens/ C&S/ L&T |
| 125 | S&F Power Contactor AC 3Phase, 4-Pole, 330A all as specified and directed.Make: HPL Cat No: SDE-330a/4 or equivalent in make of Simens/L&T/Havells |
| 126 | S&F Power Contactor AC 3Phase, 4-Pole, 150A all as specified and directed.Make: HPL Cat No: SDE-150a/4 or equivalent in make of Simens/L&T/Havells |
| 127 | S&F Single phase preventor 415VAC all as specified and directedMake: ELLICO Type: ESP-2 or equivalent in make of C&S/L&T/Simens |
| 128 | S&F Phase failure relay type VSP-D2 auxiliary supply 415 VoltMake Minilec or equivalent in Gelco or Ambilin as approved. |
| 129 | S&F Timer for ATS starter with coil.all as specified and directed |
| 130 | S&F MCCB four pole 400 amps, 36 KA, thermally adjustablesuitable for AMF Panel all as specified and directed |
| 131 | S&F Relay for AMF Panel at MH all as specified and directed |
| 132 | S&F Contactor for AMF Panel,400Aall as specified and directed |
| 133 | S&F Timer for AMP panel at MH all as specified and directed |
| 134 | M&L for Lifitng of non clog submersible of sewage pump from existing sump well ,cleaning of blocked sludge /floating plastic bags ,washing and relowering the pump including disconnection/connections and when odered in emergency servicescomplete all as specified and directed. |
| 135 | M&L for Rewinding of motor of non clog /submersible pump set,any capacitywith suitable gauge of super enameled copper winding wire including temperature sensor including varnishing, heating, painting with two coats of synthetic enamel spray paint, testing for satisfactory running at site of following capacities:- |
| 136 | 12.5 HP |
| 137 | 7.5 HP |
| 138 | M&L for Renewal of mechanical seal of non clog submersible pump set of any makeincluding moisture sensor of following capacities:- |
| 139 | 12.5 HP |
| 140 | 5/7.5 HP |
| 141 | M&L for Renewal ofspare parts such as end cable bush, upper & lower ball bearing, oil C-40, O ring & gasket, marking tape etc of non clog submersible pump set of capacity 28.5 HP of makeKSB Type KRTUPK-100-260/74 complete all as specified and directed |
| 142 | S&F Rubber mat of 1 meter x 2 meter x19mm all as specified and directed. |
| 143 | M&L for Renewal ofspare parts such as end cable bush, upper & lower ball bearing, oil C-40, O ring & gasket, marking tape etc of non clog submersible pump set of capacity 12.5 HP of makeKSB Type KRTUPK-100-260/74 complete all as specified and directed |
| 144 | M&L for Renewal ofspare parts such as end cable bush, upper & lower ball bearing, oil C-40, O ring & gasket, marking tape etc of non clog submersible pump set of capacity 5/7.5 HP of makeKSB Type KRTUPK-100-260/74 complete all as specified and directed |
| 145 | M&L for Renewal of following spare parts suitable for existing open execution star delta starter installed in sewage panels including all necessary connections complete all as specified and directed |
| 146 | S&F Current Monitoring relay32A-70A, 95 NC, 98 NO all as specified and directed |
| 147 | S&F Timer for relay type 800S-230 for supply voltage 230V, AC ± 20%, contact 5A, 250 V AC. Make Selectron or equivalent in L&T / Schneider complete all as specified and directed |
| 148 | S&F in replacement of MCB tripple pole 63 amps \"C\" series,all as specified and directed. |
| 149 | S&F in replacement of MCB four pole 63 amps \"C\" .series as per Legrand cat ref bo 408702 or equivalent in Schneider or Hager as approved complete all as specified and directed. |
| 150 | S&F in replacement of MCCB 630 amps, 36 KA,four pole complete all as specified and directed.. |
| 151 | S&F in replacement of MCCB 250 amps, 36 KA,four pole complete all as specified and directed.. |
| 152 | S&F in replacement of MCCB 200 amps, 25 KA, four pole complete all as specified and directed.. |
| 153 | S&F in replacement of MCCB 100 amps, 25 KA, four pole complete all as specified and directed.. |
| 154 | S&F in replacement of MCCB 100 amps, 16 KA, three pole complete all as specified and directed.. |
| 155 | S&F in replacement of MCCB 125 amps, 16 KA,four pole complete all as specified and directed.. |
| 156 | S&F Battery Charger with input voltage 170-270VAC, 50Hz and output voltage 12VDC, output current of 10A suitable for workshop and garages complete all as specified and directed.Make: Lubi Cat No: LEBC1210A12V or equivalent in make of Bosch/Philips/VTECH |
| 157 | Material and Labour with tools and machinery for cleaning of sewage sump well draining out sludge/floating particlesoutside the cantonment area up to the satidsfaction of engineer-in- charge complete all as specified and directed |
| 158 | S&FPVC braided pipe (House pipe) heavy duty 100 mm bore for suction in sewage line complete all as specified and directed.. |
| 159 | S&F Hand operated chain pully blocksheavy duty indef chain 3 Ton fall lift 15 mtr or suitable for lifting non clog sumersible pumpcapacity with powerfull chain complete all as specified and directed . |
| 160 | M&L for Renewal of PVC insulated PVC sheathed copper conductor flexible cable water /oil proof suitable for non clog sumersible pump set ,size of 10 core 1.5 sqmm multistranded dewatering cable including of good making of water proof epoxy joint at motor termination as required complete all as specified and directed. |
| 161 | Supply only Calcium Hypo Chloride Calcium based granular disinfectant having 65% to 70% Chlorine content for water treatment packed in 50 kg drum complete all as specified and directed . |
| 162 | Supply only copper sulphate crystal of best quality as approved complete all as specified and directed.. |
| 163 | Supply only white alum ferric crystal of best quality as approved complete all as specified and directed.. |
| 164 | Supply only Calcium Trichloroisocyanuric acid granules Having Chlorine content not less than 90% for swimming pool water treatment packed in 50 kg drum complete all as specified and directed.. |
| 165 | Supply &fixing of Suction sweeper brush with assembly (Brush with connecting roaler stand )or as per existing brush for swimming pool cleaning complete all as specified and directed.. |
| 166 | S&F multiport valve of reputed make suitable for bobbin wound sandfilter of capacity 35 Cubic meter per hour for swimming pool water filtration complete all as specified and directed |