| 1 | Surface dressing n.exc 15 cm including cleaning away all grass Sqm vegetation, saplings, shrubs, brushwood, undergrowth and trees not exceeding 30 cm girth complete all as specified and directed. |
| 2 | Surface excavation n.exc 30cm deep and averaging 15cm deep and getting out in soft/ loose soil complete all as specified and directed. |
| 3 | Excavating over areas, n exc 1.5 m deep and getting out in soft/loose soil complete all as specified and as directed. |
| 4 | Excavating over areas, exc 1.5 m deep and getting out in soft/loose soil complete all as specified and as directed. |
| 5 | Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5M in depth for foundation etc and getting out in any type of soil complete all as specified and as directed. |
| 6 | M&L for Treating the bottom and sides of excavation at the rate of 5 litres of emulsion per square metre of surface area complete all as specified and directed. |
| 7 | M&L for Treating the backfill in contact with foundation at the rate of 7.5 litres of emulsion per square metre of vertical surface (Area of the sub structure in contact with backfill to be measured) complete all as specified and directed. |
| 8 | M&L for Treating the top surface of filled earth at the rate of 5 litres of emulsion per square metre of surface complete all as specified and directed. |
| 9 | M&L for Treating the soil under plinth protection at the rate of 5 litres of emulsion per square metre of surface area complete all as specified and directed. |
| 10 | Returning filling including spreading, levelling, watering and well ramming in layers n exc. 25cm complete all as specified and directed. |
| 11 | Removing excavated materialn exc 50mand depoting where directed at a level n exc 1.5m above the starting point complete all as specified and directed. |
| 12 | M & L cement concrete 1:4:8 of type D2 (using 40mm graded stone aggregate) as in foundations filling and mass concrete complete all as specified and directed. |
| 13 | Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter complete all as specified and directed. |
| 14 | M & L for Reinforced cement concrete1:2:4 type B1 (using 20mm graded aggregate) as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and directed. |
| 15 | M & L Formwork to sides of pillars, posts, struts, piers, columns and stanchions complete all as specified and directed. |
| 16 | M & L for Reinforced cement concrete1:2:4 type B1 (using 20mm graded aggregate) as in columns, pillars, piers, posts and struts etc complete all as specified and as directed. |
| 17 | M & L for formwork to sidesand soffits of floor or roof beam, rough finished of flat concrete surface including suppots, overhangs etc complete all as specified and as directed. |
| 18 | M & L for Reinforced cement concrete 1:2:4 type B1 (using 20mm graded aggregate) as in Beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and as directed. |
| 19 | M&L for fromwork to flat rough finished surfaces soffit of concrete sunpended slab not exc 200mm thick horizontal or sloping complete all as specified and directed. |
| 20 | M&L for Formwork to edges of concrete flats, breaks in floors, openings in concrete walls, floors and roofs and sides of RCC/PCC bands in walls, horizontal or sloping, and similar work all exceeding 20cm wide. (Where RCC/PCC band in walls, spanning and opening, complete all as specified and as directed. |
| 21 | M&L providing reinforced cement concrete type B1 (1:2:4) using 20 mm graded stone aggregate as in roof slabs supported on walls surfaces of concrete flat complete all as specified and directed. |
| 22 | M&L providing reinforced cement concrete type B1 (1:2:4) using 20 mm graeded stone aggregate as in chajja all as specified and as directed. |
| 23 | M&L for mild steel TMT bars 10 mm dia over cut to length, bent to shape required including cranking, bending, hooking ends & binding with mild steel wire (annealed) not less than 0.90mm dia or securing with clips completeall as specified & as directed. |
| 24 | M&L for mild steel TMT bars 6mm to 8mm dia over cut to length, bent to shape required including cranking, bending, hooking ends & binding with mild steel wire (annealed) not less than 0.90mm dia or securing with clips completeall as specified & as directed. |
| 25 | Ditto, but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders complete all as specified and directed. |
| 26 | M&L for Pre-cast cement concrete block masonry with solid blocks, PCC 1:3:6 typeC1 (20mm graded aggregate exc. 10 cm in width and setting in mortar 1:6, complete all as specified and as directed. |
| 27 | M&L rendering 15mm thick in cement plaster 1:4 on surfaces other than fair faces of brick work and surfacemixing with WPC as per Manufactures instruction, finished even and fair without using extra cement complete all as specified and as diected. |
| 28 | M&L rendering 10mm thick in cement plaster 1:6 on fair faces of brick work and surface finished even and fair complete all as specified and directed. |
| 29 | M&L rendering 10mm thick in CM 1:4 on concrete surfaces of roof slab, mixing with WPC as per Manufactures instruction and complete all as specified and directed. |
| 30 | M&L rendering 5mm thick in CM 1:4 on ceiling of concrete surfaces and complete all as specified and directed. |
| 31 | Supply only Liquid water proofing compound complete all as specified and as directed. |
| 32 | Material & Labour for preparing new Plastered Surfaces of Walls and applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Camouflage pattern) with silicon additives @ 1.43 litre/ 10 sqm, over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces. complete all as specified and as directed. |
| 33 | Material & Labour for preparing new Plastered Surfaces of Walls and applying three coat of white wash complete all as specified and as directed. |
| 34 | Material & Labour for preparing new Plastered Surfaces of ceiling and applying three coat of white wash complete all as specified and as directed. |
| 35 | Earth filling under floor including spreading, levelling, watering and well ramming in layers n exc. 25cm thick complete all as specified and directed. |
| 36 | M & L for Hardcore of broken stone or boulder of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and directed. |
| 37 | M&L Cement Concrete 1:4:8 (40mm Graded Stone Aggregate) 100mm thick in Sub-bases, complete all as specified and as directed. |
| 38 | M&L for Cement concrete 1:2:4 type B-0, 25mm thick as in subbase (12.5mm graded aggregate) complete all as specified and directed. |
| 39 | M&L Machine Cut Kota Stone Slab 20-25mm thick in Flooring over and including Cement Screed 15mm thick in Cement Mortar 1:6, laid and jointed with Grey Cement Slurry mixed with Pigment to match the Shade of the Slab including Rubbing and Polishing, complete all as specified and as directed.NOTE : Cost of Cement Screed Bed will deem to be included in the Quoted Unit Rate. |
| 40 | M&L Coloured Glazed Ceramic Tiles in vertical surface 450X 350X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match the Tiles, laid over and including 15mm thick rendering as Screed or backing coat of wall tilein Cement Mortar 1:4, complete all as specified and as directed.NOTE : Cost of Cement Screed Bed shall deem to be include in the Quoted Unit Rate. |
| 41 | M&L for preapring clean and dried plaster surface and applying a coat of oil based bitumen primer confirming to (IS: 3384) at the rate of 0.30 litrs per Sqm and then laying APP based polymeric membrane minimum weighing 3kg/sqm and minimum 3mm thick reinforced withnon woven polyster reniforced membrane having thermal insulation with mineral gravel on upper side of membrane land on primed surface by torch application methodcomplete all as specified and directed. |
| 42 | M & L for 75mm thic cement concrete type C1 1:3:6 (20mm garded stone aggregate) as in plinth protection complete all as specified and as directed. |
| 43 | S&F fibre glass mesh 145Gsm as in various column/beam joints before plaster work with necessary fitting and fixtures complete all as specified and as directed. |
| 44 | S&FSteel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded, complete all as specified and as directed. |
| 45 | Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete Fe-290, (Gde E- 165). |
| 46 | S&F 1mm thick Mild steel, plain, black sheet in wall cladding, steel gates and similar work, cut to size, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc. as required complete all as specified and directed. |
| 47 | M&L preparing New or previously untreated Steel and Iron Surfaces of any description, over 10 Cm width or girth and applying Two Coats of Synthetic Enamel Paint (First quality) over a Red Oxide Zinc Chrome Primer, complete all as specified and as directed. |
| 48 | S&F Sheet Glass 4.0mm thick, Ordinary quality and glazing with Oil Putty in Square exc. 0.50 Sqm in Each Pane of Steel Windows, complete all as specified and as directed. |
| 49 | Excavation over area not exc 1.5 mtr deep and getting out hard/dense soil complete all as specified and directed. |
| 50 | All as per items No1 above but exc 1.5 mtrbut not 3.0 mtr deep complete all as specified and directed. |
| 51 | All as per items No1 above but exc 3 mtrbut not 4.5 mtr deep complete all as specified and directed. |
| 52 | M & L for design mix renforced cement concrete M-30 ( Using 20 mm graded stone aggregate) as in foundation plinth beam cantilevers, bressummers etc,all as specified and directed |
| 53 | M & L for design mix renforced cement concrete M-30 ( Using 20 mm graded stone aggregate) as in wall, retaining walls and like, any thickness, above top of footing including attached pilasters and buttresses all as specified and directed |
| 54 | M & L for design mix renforced cement concrete M-30 ( Using 20 mm graded stone aggregate) as in beams, cantilever beam etc all as specified and directed |
| 55 | M & L for design mix renforced cement concrete M-30 ( Using 20 mm graded stone aggregate) as in dome slab etc all as specified and directed |
| 56 | M & L for form work to face of walls, retaining wall, etc for rough finished surface of concrete, verticle or to batter complete all as specified and directed. |
| 57 | M&L PCC (1:3:6) type C2 as in plinth protection finish surface even and smooth using extra cement (100 mm thick) incl forming dummy joints at 2mtr centre to centre and filled with lean mortar (1:8) all as directed by Engineer-in-Charge |
| 58 | M&L for rendering 15mm thick cement plaster in CM( 1:3) on fair face of block or concrete surface with water proffing compound finished even and smooth without using extra cement complete all as specified and directed. |
| 59 | M&L for rendering 5mm thick cement plaster in CM( 1:3) on fair face of block or concrete ceiling surface with water proofing compound finished even and smooth without using extra cement complete all as specified and directed. |
| 60 | M&L for rendering 15mm thick cement plaster in CM( 1:4) on fair face of blockor concretesurface with water proofing compound finished even and smooth without using extra cement complete all as specified and directed. |
| 61 | M&L for preparation on newly plastered wall surface and appplying two coats of cement base paint complete all as specified and directed. |
| 62 | Supply only integral waterproofing compound of approved quality complete all as specified and directed. |
| 63 | M&L for PCC(1:2:4) type B-0 (12.5 mm graded aggregate) 40mm thick as in floor with even and smooth finishing without using extra cement complete all as specified and directed. |
| 64 | S&F for mild steel as in framed work such as grills, gratings etc with ends of bars shouldered and or riveted or forged into spikes, framded guard bars, barres iron doors, MS rungs, ladders, framed balustered, walk ways, railingand similar work conforming to Fe-290 Gde E-165 complete all as specified and directed. |
| 65 | M&L for two coats of synthetic enamel paint over a coat of Red oxide primer including preparation of new steel/iron surface of any description over 10 cm in width or girth complete all as specified and directed. |
| 66 | S&F for central bulbed type PVC water bars 150mm wide10mm thick in construction joints complete all as specified and as directed. |
| 67 | M&L for cement concrete type B-2 (1:2:4) (using 40mm graded stone aggregate) as in surface channel and drain complete all as specified and directed. |
| 68 | S&F Cast iron work grade FG 150, unmachined, in manhole covers, and similar articles exc 5Kg each complete all as specified and as directed. |
| 69 | S&F Cast iron cowls 100mm dia all as specified and as directed. |
| 70 | M&L for Surface excavation in hard and dense soiln.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting outand removing up to 50mtr complete all as specified and as directed as in hard/dense soil |
| 71 | M&L Cement Concrete 100 mm thic 1:3:6 type C2 (40mm Graded Stone Aggregate) 100mm thick in Sub-bases, complete all as specified and as directed. |
| 72 | M&L Cement Concrete 1:2:4 (20mm Graded Stone Aggregate) 100mm thick as in flooring , complete all as specified and as directed. |
| 73 | M&L for laying pre-polished 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footpath parks, lawn drive ways or light traffic parkings etc of required sterngth, thickness & sizeocompaction by using plate vibrator, filling the joints with sand and cutting of paer blocks as per required size and pattern, finishin and sweeping extra sand, including taking out existing odl pace rblokks and removing from site complete ll as pseecified and aas directed. |
| 74 | M&Lsand filling under floors or in foundation incl watering and consolidation complete all as specified and directed. |
| 75 | M&L Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete all as specified and directed. |
| 76 | Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, watering, and removing surplus soil to a distance n exc 50 m and making good surface complete all as specified and directed. |
| 77 | M&L for Cement concrete 1:2:4 type B2 as in foundations, filling and mass concrete complete all as specified and as directed. |
| 78 | S&F mild steel work as in posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc. and similar work conforming to Fe-290 Gde E-165 complete all as specified and as directed |
| 79 | Supply only Chain link MS galvanisd fencing, any size or type complete all as specified and as directed. |
| 80 | Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provission of binding wire complete all as specified and directed. |
| 81 | Mild steel round bars 10mm dia and over, horizontaly woven in chain link fencing including cut to length, bent to shape required, including cranking, bending etc complete all as specified and as directed. |
| 82 | S&F Mild steel screw bolts 12mm dia (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, exc 5cm but n exc 10m long complete all as specified and directed. |
| 83 | M & L for Sand fillingin trenchesas cable protection including wateringand consolidation complete all as specified and direted. |
| 84 | M & L for boring under road/ hard standing by trench less technology using ultra soundmethodincluding 150 mm HDPE pipe 10 KG pressurerating completeall as specified and directed by Engineer In Charge. |
| 85 | M&L for brick protection cover to underground cable with sub-class ‘B’ old size over burnt bricks laid dry and flat across the axis of cable, abutting each other with gaps between adjacent bricks not exceeding 10mm complete all as specified & directed. |
| 86 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminiumconductor of size 95 sq mm 3.5 core complete all as specified and directed by Engr-in-charge. |
| 87 | M & L for earthing complete with galvanised steel earth plate electrode of size 60 cm x 60 cm x 6mm thick burried directly in ground not less that 2.25 m deep below normal ground level and top edge of the plate not less than 1.5 mtrs below normal ground level connected to GI strip of size 25 x 4 mm by means of bolts, nuts, check nuts and washers of GI or steel all as shown in electrical palte No 3 connected to earthing test point incl excavation, earth work in any type of soil strata, PCC chamber, 40 mm dia GI med grade pipe as protection of strip and 15 mm dia GI Med grade watering pipe, funnel, wire mesh etcincluding testing on completion all as specified and directed. |
| 88 | Supply, install, test and commissioning LT Panel board, TPN 415 Volts, 50 Hz,out door cubical type floor mounted CPRI approved factory made,double doordust and vermin proofIP-54, fabricatedout of CRCA sheet not less than 3.15 mm thickwith 2mm thick for internal compartment duly powder coated fixed on angle iron pedestalmade out of 50x50x6 mm with cable chamberfor individual feeders for incommingand outgoing connections,one set of LED indicator lampRYB with switch and fuse and the panel board shall be provided with proper ventillation including suitable size of cable alley copper bus bar suitable for carrying of current400 Amps with suitable connections from MCCB out going to main bus bar shall be carried out with TPN copper bus bars of suitable rating and connections from main bus bar to out going MCCB\"s (intake point) will be carried out with TPN copper bus bar as per MCCB rating duly insulated and colour coded heat shrinkable sleeve and shall be rigidly mounted on suitable size of bridge insulator including necessary PCC foundation of minimum 0.35 m height positioned and fixed with suitable nut, bolts, washers etc to the MC pedestal all as specified and directed comprising of the following :-(a) MCCB 250 Amps 4 Pole 50 Hz 415 V with adjustable thermal and adjustable magnatic (4 Pole) having rupturing capacity 25KA -1 Nos (incoming).(b) MCCB 100 Amps 4 Pole 50 Hz 415 V with thermal magnectic release having rupturing capacity 16 KA - 1 Nos (Outgoing).(c) MCCB 63 Amps 4 Pole 50 Hz 415 V with thermal magnectic release having rupturing capacity 16 KA - 2 Nos (Outgoing).(d)FASD starter suitable for 40 HP Centrifugal pump - 02 Nos ( 1 W + 1 S) for fire pump(e)FASD starter suitable for 15 HP Centrifugal pump - 02 Nos ( 1 W + 1 S) (for jockey pump)(f) 3 Phase digital multi function meter modelA, class 1, 5A with relay Vega Series - 1Nos(g) Indicating lamp 240 volts LED type - set of three. |
| 89 | S&F of150 mm bore, ductile iron pipe with spigot and socket ends class K-9 suitable for and including tyton joints in any length laid in trenches, completeall as specified and as directed. |
| 90 | Supply and lay Pipes MS ERW Steel including specials, nominal dia 150 mm as per IS 3589 (1981) thickness 6.0 mm complete all as specified and directed |
| 91 | Supply and lay Pipes MS ERW Steel including specials, nominal dia 200 mm as per IS 3589 (1981) thickness 6.0 mm complete all as specified and directed |
| 92 | S&F of Tubes, \"medium grade\", galvanised, with all fitting; of size 80 mm dia laid in trenches jointing complete including laid in trenches/floor at places where directedcomplete all as specified and directed. |
| 93 | S & F of150 mm bore cast iron flanged & drilled both ends sluice valve, (ISI marked) long body type, conforming to IS 14846-2000; Class PN-1.6 with iron wheel head & brass spindle including all jointing materials and mild steel nuts, bolts, washers, rubber / fibre board gaskets etcand testingcomplete all as specified & directed. |
| 94 | S & F of80 mm bore cast iron flanged & drilled both ends sluice valve, (ISI marked) long body type, conforming to IS 14846-2000; Class PN-1.6 with iron wheel head & brass spindle including all jointing materials and mild steel nuts, bolts, washers, rubber / fibre board gaskets etcand testingcomplete all as specified & directed. |
| 95 | Supply and fix Valve, reflux, with by-pass Arrangement, 150 mm (6”) dia completeincluding all jointing materials and mild steel nuts, bolts, washers, rubber / fibre board gaskets etcand testingcomplete all as specified & directed. |
| 96 | Supply and fix Foot Valve conforming to IS 4038, 150 mm (6”) dia. completeincluding all jointing materials and mild steel nuts, bolts, washers, rubber / fibre board gaskets etcand testingcomplete all as specified & directed. |
| 97 | Supply and fix 63 mm dia 15 meter long hose conforming to IS 636 complete with male and female coupling conforming to IS 903 including testingcomplete all as specified & directed. |
| 98 | Shifting and Re-Fixing, installation, servicing, testing and commissioning of centifugal pump of 40 HP complete including electrical connection with three phase of copper cable of required size from conenctor of motor to FASD starter at LT Panel complete all as specified and directed by Engineer in Charge. |
| 99 | Shifting and Re- Fixing, installation, servicing, testing and commissioning of jockey pump of 15 HP complete including electrical connection with three phase of copper cable of required size from conenctor of motor to FASD starter at LT Panel complete all as specified and directed by Engineer in Charge. |
| 100 | Shifting and Re- Fixing, installation, servicing, testingand commissioning of Diesel driven centrifugal pump with diesel engine of 40 HP completeall as specified and directed by Engineer in Charge. (Note :- 1. Serving of complete diesel engine inclduing hange of engine oil, filters, collant etc are inclusive of rates quoted by contractor). 2. For testing of diesel driven pump, DHPP \"N\" shall be provided by department only) |