Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | B & R Division Items |
| 2 | Demolition of un-reinforced cement concrete in ground floor and paving not exceeding 15 cm thick (below or above ground level) complete all as specified and directed. |
| 3 | Demolition of brick work or stone/ boulder masonry, built in cement mortar including all quoins, pillars etc. complete all as specified and as directed. |
| 4 | Dismantling floor, hearth or wall tilling including cement mortar bedding (but not backing) removing serviceable tiles to stores and rubbish off the premises. |
| 5 | Dismantling stone slabs of any description or thickness in floors, aprons etc. laid, bedded and pointed in any mortar and disposing off complete all as specified and as directed |
| 6 | Demolition of reed lathing, single or double including battens and plaster or chiken wire lathing all as specified. |
| 7 | Dismantling mild steel work or wrought iron of any description and in any position complete all as specified and as directed. |
| 8 | Dismantling plain or corrugated steel sheeting, any gauge or any thickness as in roof covering, wall cladding, etc.including all necessary staging / scaffolding, etc. as required complete all as specified and as directed. |
| 9 | Dismantling of timber scantling 40 Sqcm and over in section, in any position in framed work complete all as specified and directed. |
| 10 | Taking down cement plaster on brick or stone walls etc, including raking out joints, hacking for key scrubing down with water etc complete all as specified and as directed. |
| 11 | Taking down chowkhats or frame with shutters (without taking off shutters from frame) each not exceeding 1.50 Sqm each complete all as specified. |
| 12 | Taking down Chowkats or frames with shutters exceeding 1.5 Sqm but not exceeding 4 Sqm each (without taking off shutters from the frame) complete all as specified. |
| 13 | Surface dressing n exc 15 cm deep and gettingout in soft / lose soil complete all as specified |
| 14 | Excavating in trenches, n exc 1.50 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out soft/ loosetype of soil complete all as specified and directed. |
| 15 | Returning, filling in trenches including spreading, leveling watering and ramming in layers not exceeding 25cm all as specified. |
| 16 | Removing of surplus soil not exceeding 50 m and deposited where directed at a level not exceeding 1.50m above the starting point all as specified. |
| 17 | M&L for earth filling under floor incl spreading ,levelling & well ramming includuing watering as required n exc . 25 cm thick . (Note :- Earthobtained from item no 04 is reused ) |
| 18 | M&L for fine dry river sand filling under floors, watering, leveling and consolidating complete all as specified and as directedNote: Only consolidated thickness of sand shall be considered for measurement purposes |
| 19 | Supplying and laying Polythene film, 150 micron thick,@ 0.30 to 0.50 kg per sq. m water proof, wrinkle free without puncture over tack coat/sand cushion as specified in the design with overlap between adjacent strips and at transverse joints as minimum 300mm.(No additionaI amount to be paid for overlap) |
| 20 | M&L for Treating the bottom and sides of excavation at the rate of 5 litres of emulsion per square metre of surface areacomplete all as specified. |
| 21 | M&L for Treating the backfill in contact with foundation at the rate of 7.5 litres of emulsion per square metre of vertical surface (Area of the sub structure in contact with backfill to be measured) complete all as specified. |
| 22 | M&L for Treating the top surface of filled earth at the rate of 5 litres of emulsion per square metre of surfacecomplete all as specified. |
| 23 | M&L for Treating the soil under plinth protection at the rate of 5 litres of emulsion per square metre of surface area complete all as specified. |
| 24 | M&L for Treating the soil along with external perimeter of building at the rate of 2.25 litre of emulsion per metre of the perimeter wall complete all as specified. |
| 25 | M&L for moorum/red bajri filling in floors or pavings, laid in layers n exc. 15 cm thick ,spread, levelledincluding watering complete all as specified and directed. |
| 26 | M&L for Hardcore broken stone of gauge n exc 63mm deposited spread and levelled in layers n exc 15cm thick watered and rammed to a true surface complete all as specified and directed. |
| 27 | M&L for PCC (1:4:8), Type D2 using 40 mm graded stoneaggregate as in foundations, sub-base,filling and mass concrete complete all as specified. |
| 28 | M&Lfor providing 100 mm thick cement concrete (1:4:8) type D-2 using (40mm gradedstone aggregate) as in Sub base of floor rough surface complete all as specified. |
| 29 | M & Lfor plain cement concrete 1:3:6 type C-2 (using 40mm graded stone aggregates) as in foundations, sub-base,filling and mass concrete. all as specified and dirceted |
| 30 | M & Lfor Plain Cement Concrete(1:3:6) type C1 using 20mm graded stoneaggregate as in surface channel and drainall as specified and directed. |
| 31 | Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends foretccomplete all as specified and directed. |
| 32 | Add or deduct for each 25 mm girth or part thereof over or under 30cm(For adjustment in girth of item mention above) |
| 33 | Material and labour for 75mm thick plain cement concrete 1:3:6 type C1 using 20mm graded stone aggregate as in plinth protection finished even and fair without using extra cement complete all as specified. |
| 34 | M & Lfor 75mm thickcement concrete 1:3:6 type C2 (using 40mm graded stone aggregate) as in plinth protection finished even and fair without using extra cement laid inpanels and joints filled with bituminous mastic filling with 1 part of bitumen and 3 part of sand complete all as specified and directed. |
| 35 | M & L for plain cement concrete (1:2:4) type B1 using 20mm graded aggreagate as in bed blocks, coping , cills, steps, kneelers, bed plates, apex stones kerbs and similar works including necessary formwork complete all as specified and directed. |
| 36 | M&Lfor providing 25 mm thick cement concrete (1:2:4) type B-0 using (12.50mm gradedstone aggregate) as in flooringto receive the topping layers complete all as specified. |
| 37 | Material and labour for 50 mm thick Plain Cement concrete type B2 1:2:4 (40mm graded crushed stone aggregates) for sub base in floor fair and rough for receiving tiles, topping layer all as specified and directed. |
| 38 | M & L for Precast reinforcement cement concrete (1:2:4) type B1 using 20mm graded aggreagate as in cover slab for man holes, chullah hoods, chajja, water troughts, mangers, shelves and similar article with plain faces set in cement mortar (1:4) incl necessary formwork complete all as specified and directed. |
| 39 | Use and waste formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter rough finished flat surfaces of concrete complete all as specified and as directed. |
| 40 | Use and waste formwork to sides and soffits of floor or roof beam, beam hunching, girder, lintels, cantilever, shelves including supports etc for rough finished flat surfaces of concrete complete all as specified and directed |
| 41 | Use and waste of formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) complete all as specified and directed |
| 42 | Use and waste of formwork to sides of pillars, posts, struts, piers, columns and stanchions for rough finished flat surfaces of concreteall as specified and directed. |
| 43 | Use and waste Formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/ PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide all as specified and directed. |
| 44 | Material and labour for Reinforced Cement Concrete M-25 (design mix) using 20 mm graded aggregate as in foundation including rafts, footings, foundation beams, plinth beams, bases for columns etc complete all as specified and directed. |
| 45 | Material and labour for Reinforced Cement Concrete M-25 (design mix) using 20 mm graded aggregate as inbeams, cantilever, lintels over 1.5m complete all as specified and directed. |
| 46 | Material and labour for Reinforced Cement Concrete M-25 (design mix) using 20 mm graded aggregate as incolumn, pillars, piers, posts, and struts complete all as specified and directed. |
| 47 | Material and labour for Reinforced Cement Concrete M-25 (design mix) using 20 mm graded aggregate as in slab supported on walls, beams and columns in floors, roof landig balconies, canopies, deck slab and shelves and like complete all as specified and directed. |
| 48 | M & Lfor 10mm dia and over TMT bars, cut to length bend to shape as required including cranking, hooking etc and binding with and including mild steel wire (annealed) not less than 0.9 mm dia complete all as specified and directed. |
| 49 | M & Lfor 6mm to 8mm dia and over TMT bars, cut to length bend to shape as required including cranking, hooking etc and binding with and including mild steel wire (annealed) not less than 0.9 mm dia complete all as specified and directed. |
| 50 | M & Lfor Mild Steel TMT Bar 6mm dia and over up to 10 mm dia as in stirrups, spacers and binders as required including cranking, hooking etc and binding with and including mild steel wire (annealed) not less than 0.9 mm dia complete all as specified and directed |
| 51 | M & L for brickwork with subclass \"B\" or locally available best qualityold size bricks, straight or curved on plan exc 6 m mean raduis,built in CM (1:6) complete all as specified and directed. |
| 52 | M & L for half brick work in cement mortar (1:4) straight or curved on plan to any radius with locally available Subclass ‘B’ old size best quality bricks all as specified . |
| 53 | M&L for 10 mm thick rendering in cement mortar (1:3) on Roof slab surface & water proofing compound mixed @ 3% finished fair and even complete all as specified.Note :- WPC measured and paid saperately. |
| 54 | M&L for 5 mm thick rendering in cement mortar (1:3) of cieling surfacesfinished even and smooth complete all as specified. |
| 55 | M & Lrendering 10mm thick cement plaster on other than fair faces of brick wall or condrete surfaces in CM (1:6) finished fair and even complete all as specified. |
| 56 | M & Lfor 15 mm thick renderingin cement mortar 1:4 on fair faces of brick wall or concrete surfaces, finished the surfaces even and fair without using extra cement complete all as specified. |
| 57 | M & Lrendering 15 mm thick cement plaster in two layer each of 10+5 mm thick on fair faces of brick wall or condrete surfaces in CM (1:4) & water proofing compound mixed with second layer @ 3% finished fair and even complete all as specified. (Note :WPC measured separately). |
| 58 | M&L for 20 mm thick rendering on fair face of brick or concrete surface in cement mortar (1:3) with WPC mixed @3% finished even and fair using extra cement complete all as specified. |
| 59 | Supply only integral water proffing compound WPC complete all as specified. |
| 60 | M & LNon Skid ceramic tiles colour7 to 8mm thick (square/rectangular) area of each tile exceeding 0.11 but not exceeding 0.18 sqm, as in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile including15 mm thick screed bed or bedding layers in cement mortar 1:6overbrushing with neat cement slurry as specified |
| 61 | Material and labour Non-skid coloured ceramic tiles 7 to 8 mm thick ( square/rectangular) area of each tiles exc 0.18 sqm but not exc 0.38 sqmas in floors set and jointed in cement slurry and pointed in white or colour cement to match the shade of tile over and including screed bed or bedding layers of 15 mm thick cement mortar (1:4)complete all as specified |
| 62 | Material and labour Non-skid coloured ceramic tiles 7 to 8 mm thick ( square/rectangular) area of each tiles exc 0.18 sqm but not exc 0.38 sqm as in vertical surfaces of skirting/bdado etc over 10 mm thick rendering in cm (1:4) complete all as specified. |
| 63 | M & LGlazed ceramic coloured tilesin vertical surface size 450mm x 350mm x & ( 6mm to 7mm )mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match over & including10mm thick screed bed or backing coat in cement mortar 1:4layingof skirting/dado on walls all as specified and directed. |
| 64 | M&L in repairs for 18-20mm thick granite stone slab, of any type, table rubbed and polished, in steps, jambs, pillars, window cills, cooking platforms and the like in laid over and including 15mm thick screed in cement mortar (1:4) (rate shall be included) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of slab and taking off old damaged slab and disposing off complete all as specified and as directed. |
| 65 | M&L pre-polished chequered coloured paver tiles 25mm thick, area of each tile exceeding 0.06sqm but not exceeding 0.11sqm, in floors, set, jointed & pointed with neat white cement slurry mixed with pigment to match colour of tile, laid over and including 15mm thick screed bed or bedding layer in cement mortar (1:4) &Brushing neat cement slurry with 3.0kg of cement per sq. metre (rate shall be included) complete all as specified and as directed. |
| 66 | M&L applying one coat of cold bituminous primer (as approved by GE) @0.25ltr/Sqm over dried up surface of concrete/ plastered including cleaning surfaces confirming to IS 3384-1986 complete all as directed by Engineer in charge. |
| 67 | Supply and laying APP based polymeric membrane 3 mm thick (Minimum), weighting not less than 3.5 kg/Sqm reinforced with polyester non woven fabric (weighting not less than 160 gms/sqm) shall be applied over Bituminious primer as specified above.Application of polymeric membrane shall be by torching application etc as per manufacturer\"s instructions.The overlaps shall be minium 100 mm on the transverse direction and 75 mm longitudinal direction including one coat of aluminium paint over the APP modified membrane @ 0.11 Kg/Sqm complete all as specified. |
| 68 | Supply and fix pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified. |
| 69 | Supply and fix pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified. |
| 70 | Supply and fix structural steel work in tubular/hollow sections trusses , Purlin , posts, rafteretc including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to IS 1161-1979 grade St.-240 complete all as as specified and directed. |
| 71 | S&F Roof trusses (framed), trussed,purlins, crane gantries, rails ,posts and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats nuts bolts plates (plain or chequered) etc. |
| 72 | Supply and fix Framed work such as grills, gratings, etc.. with ends of bars or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and directed. |
| 73 | S & F Solid PVC door frame of size 50 mm x 47 mm made of 5 mm plain colour PVC sheet reinforced with mild steel square tube complete all as specified in clause 8B.3.1 and shown on page 150 of MES Schedule Part-II (2010). |
| 74 | S & F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of MS tubes for top & bottom rails, MS frame covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; paneling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading and jointed together with solvent cement, supply and fixing in the frame at site as per clause 8 B.2.1 of MES schedule Part-II (2004) complete all as specified. Make: Rajshri or equivalent as approved. |
| 75 | S & F Factory made wire gauzed PVC moulded door shutter 30 mm thick (style) wire gauzed i.e. panel will be of wire gauze in lieu of PVC sheet panel. The wire gauze shall be wrapped on an additional square 8mm M.S. Solid tube and this tube shall be welded to M.S. tubes. The wire gauge shall be stretched to tighten firmly consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing. |
| 76 | M & L for second class harwood timber scantlings in wroughtfixed to framed work scantling 40 sqcm and over in section in any position complete all as specified and directed. |
| 77 | M & L for 12 mm thick Prelaminated particle board,Exterior grade, prelaminated on bothside with decorative choice lamination & otherside balancing white lamination, all as directed. |
| 78 | Supply and fixStainless steel wire cloth. 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified. |
| 79 | S & F Pressed steel frames made of 1.25mm thick MS sheet of profile 105x60mm for door and window frames with one or more rebates includinghinges (100/50mm stainless steel),lock strike plate, shock absorber, 20mm dia 60mm long MS conduit for housing of a drop bolt, treating of internal surfaces of chowkhats with coal tar or black paint including hinges, hold fasts/lugs etc complete all as specified. |
| 80 | M & LPlain Cement concrete (1:3:6), type C-0 using 12.5mm graded stone aggregate as in filling of steel chowkhatsand concrete for fixing of holdfast including necessary form work complete all as specified. |
| 81 | S&F Powder coated aluminium (minimum thickness of powder coating 50 micron) for shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/neoprene gasket required (Fittings shall be paid for separately) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws all complete as per architectural drawings and the directions of Engineer-in-charge |
| 82 | S&F 3.00 mm thick sheet glass frosted ordinary quality and glazing with oil putting square nexc 0.5 sqm in each pane complete all as specified. |
| 83 | S&F 4.00 mm thick tinted sheet glass ordinary quality and glazing with oil putting square nexc 0.5 sqm in each pane complete all as specified. |
| 84 | Supply and fix 250mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixedcomplete all as specified. |
| 85 | S&F 100mm long Butt hinges, extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed complete all as specified and directed. |
| 86 | Supply and fix 125 mm long aluminium handles cast type anodised complete all as specified & directed . |
| 87 | Supply and fix 150 mm long aluminum anodised barrel tower bolts of extruded section completeall as specified and directed. |
| 88 | S &F Vitreous China urinals, bowl type urinal flat back, size of 375 x 390 x 590 mm white (minimum), with grating and union for discharge pipe (back or corner wall type), complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and Union for discharge pipe. (Exclusive of fixing supply pipe to flushing cistern, trap and waste pipe) |
| 89 | S&F for in repair vitreous china wash basin, white, counter top, size 560 mm x 461 mm ovel shape including waste coupling but excluding taps, waste chain and plug and porcelain stopper complete all as specified and directed.Make: Hindware Cat Part No 10017 or equivalent as per make approved list. |
| 90 | Supply and fix in repair vitreous china Squatting pan, \"Orissa\" pattern, Size 580 X 440mm ,with integral foot rests (excluding flushing ciestern and flush pipe) incl necessary lime concrete and 100 mm bore cast iron \"P\" trap with 550 to 600mm long neck for connecting WC to branch piece with cement joints complete all as specified & as directed . |
| 91 | Supply & Fixed inrepairsVitreous china wash down water closet pan ( pedestal pattern ) , whitewith P or S trap incl. seat cover but excluding fixing bolts, flushing cistern and flush pipe complete all as specified and as directed. |
| 92 | S & FPVC valveless, syphonic action type,low level flushing cistren 10 ltr capacity ISI Marked incl all acessories and 32mm dia PVC flush / discharge pipe incl float valve, inlet complete all as specified. |
| 93 | S & Fsoap dish chromium plated complete all as specified. |
| 94 | S&F PVC connections 15mm dia size with PTMT nuts of length 450mm complete in all respect as specified |
| 95 | S & F 15mm bore pillar tap cast copper alloy with capstan head, chromium plated concealed screwed down high pressure with or without hot or cold with long shunk screwed shanks and fly nuts screwed for iron pipes and connecting to water pipe line complete all specified and directed. |
| 96 | S&F 15mm bore bib taps , cast copper alloy, chromium plated with crutch or butter fly handle, screwed down for iron pipe or for brass ferrule including accessories complete all as specified and directed. |
| 97 | Supply and fix 15mm bore stop valves/angle valveof cast copper alloy, screwed down, high pressure with crutch or butter fly handle, chromium plated, with long shank andfixed complete all as specified. |
| 98 | Supply and fix as in repair 15mm bore stop valves/angle valveof cast copper alloy, concealed, cup screwed down, high pressure with crutch or butter fly handle, chromium plated, with long shank fixed complete all as specified. |
| 99 | S&F 600mmx450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and directed. |
| 100 | Supply and fix Towel rail, 20mm dia brass chromium plated, 600mm long with fancy type brass chromium plated brackets on both sides and fixed with steel screws and wooden/rawl plugs as in repair complete all as specified. |
| 101 | Supply and fix 125mm dia CP brass shower rose with swivel joints, any colour including shower arm 15mm dia, 195mm long with bend of 45 degree with flange of CP brass complete all as specified.Make : Parryware cat No. T9809A1 or equivalent as per approved list of make. |
| 102 | M&L for PCC (1:3:6),Type C2 using 40 mm graded stoneaggregate as in bed to drain for 110 mm bore including packing under and hunching against side of pipe after they are laid and tested complete all as specified. |
| 103 | Supply and fix 110mm diaPVC (SWR) pipes single socketed, in any length, laid in trenches or in floors / fixed to walls complete all as specified. |
| 104 | Supply and fix 75mm diaPVC (SWR) pipes single socketed, in any length fixed to walls / floors or in trenches complete all as specified. |
| 105 | Supply and fix 110mm dia PVC (SWR) bend suitable for pipe complete all as specified. |
| 106 | Supply & Fixed inrepairs PVC (SWR) bends 75 mm bore any radius suitable for pipe complete all as specified. |
| 107 | Supply & Fixed inrepairsPVC (SWR) vent cowl110 mm suitable for pipe complete all as specified. |
| 108 | Supply and fix 110mm bore PVC (SWR) junction, single T equal or unequal with or without door access complete all as specified. |
| 109 | M & LPVC(SWR) floor trap, 75mm dia outlet, plain with grating including jointing with solvent cement complete all as specified. |
| 110 | S&F 15mm bore steel water tubing, medium grade, galvanised with screwed and socketed joints, in any length, including supply and fixing all fittings, ISI marked conforming to IS -1239 and fixed to walls or laid in floors / trenches required for water connections complete all as specified and as directed. |
| 111 | S&F 20mm bore steel water tubing, medium grade, galvanised with screwed and socketed joints, in any length, including supply and fixing all fittings, ISI marked conforming to IS -1239 and fixed to walls or laid in floors / trenches required for water connections complete all as specified and as directed. |
| 112 | Cuttinggrooves or rebates not exceeding 20 cm girth, and trimming with or without reinforced surfaces complete all as specified and directed. |
| 113 | Supply and fix 20 mm bore dia, Gun-metal, gate valves, with iron wheel head, screwed both ends on GI pipes with GI union fixed in existing/ new location completeall as specified and directed. |
| 114 | Supplying, hoisting, fixing and connecting up 2000 litre rotational moulded polythylene water storage tanks double layer (cylindrical vertical with closed top), hoisted and fixed in position all as specified in SSR Part-I including connecting the overflow drain out, inlet and outlet pipes, tank nipple, elbow, bend, unions, sockets, etc. including taking down old damaged water tank and disposing off complete all as specified and as directed |
| 115 | S&F Ball valves high pressure of PTMT with epoxy coated aluminium rod & high- density plastic bal screwed for iron pipe and fixed (min wt 15mm-142gms/20mm-210gms/25mm- 455gms/40mm-690gms) for 25mm bore pipe complete all as specified and directed. |
| 116 | S&F gun metal gate valve 20mm dia, cast copper alloy, screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe complete all as specified and directed. |
| 117 | M & Lfor preparation of new or previously untreated wall surfaces and applying three coats of white wash complete all as specified and directed. |
| 118 | M & Lfor preparation of new or previously untreated ceiling surfaces and applying three coats of white wash complete all as specified and directed. |
| 119 | M & Lfor providing and applying wall care putty in two coats of 1 mm thickness over plastered surface to prepare the surface even and smooth complete all as specified. |
| 120 | M & L preparation of new plastered surface of walls and applying two coat of oil emulsion distemper over one coat of primer with using roller complete all as specified. |
| 121 | Material & Labour for preparation of new plastered surface applying two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm using roller complete all as specified and directed. |
| 122 | M & Lpreparation of new steel surfaces of any description over 10cm width or girth not otherwise described and applying two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and as directed. |
| 123 | M & Lfor preparation of new wooden surfaces of any description not other wise described over 10 cm width or girth and applying two coat of Synthetic enamel paint over a coat of pink primer complete all as specified and as directed. |
| 124 | M & Lfor preparation of old wooden surfaces of any description not other wise described over 10 cm width or girth and applying two coat of Synthetic enamel paint complete all as specified and as directed. |
| 125 | E & M Division items |
| 126 | Taking down carefully copper/aluminium point wiring (light, fan, buzzer, socket or power) complete including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc includingremoving from site for taking credit and making good to disturbed surface of walls, floors etc as per existing specification complete all as specified and as directed. |
| 127 | Taking down carefully submain wiring including all accessories without disturbing existing wiring fittings fixtures etc and making good to the disturbed surfaces all as directed and as specified in any type and size all as directed. |
| 128 | Taking out old U/s GI PIPE of 25/32mm size/type including all GI fittings etc complete all as specified and directed. (Excavation and earth work will be measured and paid separately under respective items) |
| 129 | M & Lfor point wiring with FRLSH stranded copper conductor1.5 sqmm (nominal area), two single core, PVC insulated cable 1100 volts grade, ISI-694 markedin and including heavy duty, PVC Conduit including all accessories etc ISI marked, with GI sunken box suitable for fixing switches, sockets and regulators including PVC insulated stranded copper conductor 1.5 sqmm (nominal area) single core cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed for One light point controlled by one switch. |
| 130 | M & Lfor point wiring with FRLSH stranded copper conductor1.5 sqmm (nominal area), two single core, PVC insulated cable 1100 volts grade, ISI-694 markedin and including heavy duty, PVC Conduit including all accessories etc ISI marked, with GI sunken box suitable for fixing switches, sockets and regulators including PVC insulated stranded copper conductor 1.5 sqmm (nominal area) single core cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed for One fan point/exhaust fan point controlled by one, one way switch 5 Amp. |
| 131 | M & Lfor point wiring with FRLSH stranded copper conductor1.5 sqmm (nominal area), two single core, PVC insulated cable 1100 volts grade, ISI-694 markedin and including heavy duty, PVC Conduit including all accessories etc ISI marked, with GI sunken box suitable for fixing switches, sockets and regulators including PVC insulated stranded copper conductor 1.5 sqmm (nominal area) single core cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed for One 3 pin 5 Amp socket outlet point controlled by one switch on the same board. |
| 132 | M & Lfor point wiring with FRLSH stranded copper conductor1.5 sqmm (nominal area), two single core, PVC insulated cable 1100 volts grade, ISI-694 markedin and including heavy duty, PVC Conduit including all accessories etc ISI marked, with GI sunken box suitable for fixing switches, sockets and regulators including PVC insulated stranded copper conductor 1.5 sqmm (nominal area) single core cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed forOne 3 pin 5 Amp socket outlet point controlled by one switch on independent board. |
| 133 | M & Lfor point wiring with FRLSH stranded copper conductor2.5 sqmm (nominal area), two single core, PVC insulated cable 1100 volts grade, ISI-694 markedin and including heavy duty, PVC Conduit including all accessories etc ISI marked, with GI sunken box suitable for fixing switches, sockets and regulators including PVC insulated stranded copper conductor 2.5 sqmm (nominal area) single core cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed for 3 pin, 15 Amp socket outlet, independent |
| 134 | S&Fswitch piano flush type button single pole one way 5 Amps all as specified and directed. |
| 135 | S&F socket outlet 2 in 1, 3 pin 5 Amp flush type all as specified and directed. |
| 136 | S&Fswitch piano flush type button single pole one way 15 Amps all as specified and directed. |
| 137 | S&F Socket outlet 2 in 1, 3 pin, 5 and 15amp flush type all as specified and directed. |
| 138 | S&F Socket outlet 2 in 1, 3 pin, 5 and 15amp flush type all as specified and directed. |
| 139 | S&Fswitch socket combination 5 in 1 5/16 Amp flush type with all as specified and directed. |
| 140 | S&F ceiling rose surface bakelite with three terminals all as specified and directed |
| 141 | S&F ceiling fan regulator socketed, step type, flush type heavy duty suitable to work on 230 volts Ac supply complete all as specified. |
| 142 | M & Lfor submain wiring with two single core 1.5 sqmm PVC insulated unsheathed cable multi-strand copper conductor FRLSH drawn through and including PVC non metallic rigid PVC Conduit with all fittings and fixing accessories on roof, walls, ceiling etc including 1 x 1.5 sqmm PVC insulated unsheathed multi strand copper conductor earth wire FRLSH connecting earth including cutting groove for concealed wiring, making good to disturb surface of wall/floor with cement mortar and finishes to match existing complete all as specified and directed.Note: Two run of single core cable, one run earth wire and one run PVC Conduit will be measured as one length. |
| 143 | M & Lfor submain wiring with two single core 4.0 sqmm PVC insulated unsheathed cable multi-strand copper conductor FRLSH drawn through and including PVC non metallic rigid PVC Conduit with all fittings and fixing accessories on roof, walls, ceiling etc including 1 x 2.5 sqmm PVC insulated unsheathed multi strand copper conductor earth wire FRLSH connecting earth including cutting groove for concealed wiring, making good to disturb surface of wall/floor with cement mortar and finishes to match existing complete all as specified and directed. Note: Two run of single core cable, one run earth wire and one run PVC Conduit will be measured as one length. |
| 144 | M & Lfor submain wiring with two single core 6.0 sqmm PVC insulated unsheathed cable multi-strand copper conductor FRLSH drawn through and including PVC non metallic rigid Conduit conceled with all fittings and fixing accessories on roof, walls, ceiling etc including 1 x 4.0 sqmm PVC insulated unsheathed multi strand copper conductor earth wire FRLSH connecting earth including cutting groove for concealed wiring, making good to disturb surface of wall/floor with cement mortar and finishes to match existing complete all as specified and directed. Note: Two run of single core cable, one run earth wire and one run PVC Conduit will be measured as one length. |
| 145 | Supply & Fix LED betten plastic type fitting of capacity 20W, operating on 230V, 50Hz, AC Supply having luminous efficacy of not less than 125 lumens/watts, CCT 6500K, P.F>0.9, 2.5 KV surge protection, 4-feet long, housing made out of extruded alluminium with decorative end caps elegently designed complete all as specified. |
| 146 | S&F wall mounted, compact LED batten 20 watt having 30 mins backup (working as regular 20 watt in normal mode and 4 watt in backup mode) and connecting with three core flexible copper conductor cable of suitable size from ceiling rose including taking down of old unserviceable one complete all as specified and directed |
| 147 | S&F wall mounted, compact LED batten 20 watt and connecting with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directedMake : Crompton Cat No- CCS-103-05-65-SL-DP-NWH or equivalent as per approved make list. |
| 148 | Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.. |
| 149 | S&F bldg security light, LEDluminaire 30 watt made up of pressure die cast alluminium body with mid power LED as lighting sources and PC cover having Top opening separate driver compartment with IP66 protection and impact resistance of IK07 including fixing arrangements and taking down old rusted bracket fittings completeall as per directed by Engr- in – charge. |
| 150 | S&F bldg security light, LEDluminaire 25 watt IP 66 LED lamp, made up of pressure die cast alluminium body with mid power LED as lighting sources and PC cover having Top opening separate driver compartment with IP66 protection and impact resistance of IK07 including fixing arrangements and taking down old rusted bracket fittings completeall as per directed by Engr- in – charge. Make : Crompton Cat No- TRP-415-25-57-SL-LM-NBK or equivalent as per approved make list. |
| 151 | S&F Angle bracket 40mm dia for fixing building security light of 40mm dia of 1 mtr long bent to shape 45 degree for fixing of security light including MS clamps of suitable size including nuts, bolts complete all as specified and directed |
| 152 | S&F plastic body exhaust fan300 mm sweep complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, copper winding and connecting to ceiling rose with flexible copper cable including making holes on the wall and making good to the disturbed surfaces including taking down of old UNSV one and depositing to MES store yard complete all as specified and as directed. |
| 153 | S&F Metal body exhaust fan300 mm sweep complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, copper winding and connecting to ceiling rose with flexible copper cable including making holes on the wall and making good to the disturbed surfaces complete all as specified and as directed. |
| 154 | S&F BLDC ceiling fan 1200mm sweep complete with blades, down rods and accessories, 230 V, min air delivery 210 CFM with service value 6.00 BEE 5 star rated & provn of ‘S’ type fan hook complete all as specified and directed. |
| 155 | Supply and fix electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection pipe etc complete all as specified and as directed. |
| 156 | S&F metal plug socket with MCB SP 20 Amp, 240 V enclosure for AC/equipment with neutral and earth point complete all as specified and directed. |
| 157 | S&F sheet metal enclosure powder coated single phase DB for fixing of MCBs, 8 way double door with bus bar includinggrouting on the wall by means of screws and rawal plugs and making good disturbed surfaces complete all as specified and directed. |
| 158 | S&F sheet metal enclosure powder coated three phase and neutral DB for fixing of MCBs, 4 way double door with bus bar includinggrouting on the wall by means of screws and rawal plugs and making good disturbed surfaces complete all as specified and directed. |
| 159 | S&F MCB TPN of capacity 63 Amps ,240 V, 10 KA \"B\" curve complete all as specified and directed. |
| 160 | S&F MCB SPN of capacity 40-63 Amps,240 V, 10 KA \"C\" curve complete all as specified and directed. |
| 161 | S&F MCB SP of capacity 5-32 Amps,240 V, 10 KA \"C\" curve complete all as specified and directed. |
| 162 | M & Lfor new earthing with galvanised steel earth plate electrode 600mmX600mmX6mm thick burried directly in ground (earth pit not less than 2.25 mtr below ground level) with top edge of the plate not less than 1.5 mtr below ground level connected to 4mm dia GI wire protected by 20 mm bore light grade galvanised iron pipe and other end connected to test point as directed including funnel with wire mesh and watering pipe 20 mm bore medium grade galvanised iron pipe with charcoal and common salt in alternaterlayers of 15 cm thickness all around the GI plate electrode with concrete pit in PCC 1:3:6 type C-1 with cast iron frame including cast iron cover 10mm thick hinged to CI frame and 6mm MS rod for handle, necessary excavation and earth wok in hard/dense soil and disposal of spoil to a distance n exc 50 m and necessary testing complete all as shown in electrical plate No 3 of SSR part-I complete all as specified and directed. |
| 163 | Taking out old existing earthing and M & Lfor new earthing with galvanised steel earth plate electrode 600mmX600mmX6mm thick burried directly in ground (earth pit not less than 2.25 mtr below ground level) with top edge of the plate not less than 1.5 mtr below ground level connected to 4mm dia GI wire protected by 20 mm bore light grade galvanised iron pipe and other end connected to test point as directed including funnel with wire mesh and watering pipe 20 mm bore medium grade galvanised iron pipe with charcoal and common salt in alternaterlayers of 15 cm thickness all around the GI plate electrode with concrete pit in PCC 1:3:6 type C-1 with cast iron frame including cast iron cover 10mm thick hinged to CI frame and 6mm MS rod for handle, necessary excavation and earth wok in hard/dense soil and disposal of spoil to a distance n exc 50 m and necessary testing complete all as shown in electrical plate No 3 of SSR part-I complete all as specified and directed. |
| 164 | Supply, fixing, commissioning & testing of XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, Electric power cable (heavy duty) with aluminium conductors, 1100 volts, grade cross sectional area 16 sqmm 4.0 core laid in trenches/fixed to wall/under road/pipe etc with copper cable glands & copper thimbles complete all as specified and directed. |
| 165 | Material & labour GI tube light grade 25 mm bore for protection ofcable complete all as specified and directed. |
| 166 | M & Lfor steel water tubing 25mm dia, medium grade galvanised with new fitting laid in trenches or on wall complete all as specified and directed. |
| 167 | S&F gun metal gate valve 25mm dia, cast copper alloy, screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe complete all as specified and directed. |
| 168 | M & L100mm thickPCC 1:3:6 type C2 using 40mm graded crushed stone aggregate for flooring complete all as specified and directed. |
| 169 | Excavation in trenches not exceeding 1.50 m wide and n.exc 1.5 m in depth for foundation of poles, cable etc, not exc 10 sqm on plan and getting out in soft/loose soil including taking out brick protection etc complete all as specified and directed. |
| 170 | Returning, filling in, including spreading, leveling, wateringand well ramming in layers not exc 25cm thick complete all as specified and directed. |
| 171 | Removing excavated materials (soils) not exc. 50m and depositing where directed at a level not exc. 1.5m above the starting point complete all as specified and directed. |
| 172 | M & L for sand cushioning by spreading in trenches crushed sand by gently by punning down manually as in cable protection all as specified and as directed by Engineer -in-charge.Note : Thickness of sand cushioning after punning down will be measured. |
| 173 | M&L for bricks sub-class \"B\" laid in trenches in flat style (width portion in horizontal shape) for cable protection complete all as specified and directed. |
| 174 | M & Lfor cutting of existing GI pipe line 25mm dia for inserting Tee and reducer etc for taking 25mm dia branch pipe including fittings complete |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
| 5 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail