| 1 | Surface excavation n.exc 30 cm deep and averaging 15cm deep and getting out hard and dense soil complete all as specified and directed. |
| 2 | Excavation in trenches n.exc 1.5m wide and 1.5m depth for foundation etc or for shaft well, cesspits etc n.exc 10 Sqm on plan and n.exc 1.5m depth and getting out in hard/dense soil complete all as specified and directed. |
| 3 | All as per ser item No 02 here-in-before but exc 1.5m depth but not exc 3.00m |
| 4 | M&L plain cement concrete 1:4:8, type D-2 (using 40mm graded stone aggregate),in foundation, filling and mass concrete complete all as specified and directed. |
| 5 | M&L for use & waste offormwork to rough finished surfaces of concrete, form work to sides of plinth beam, footings, bases of columns etc complete all as specified and directed. |
| 6 | M&L for RCC M-25 (Design Mix) (using 20mm graded stone aggregate) as in foundation, footing, plinth beam, bases for columns etc complete all as specified and directed. |
| 7 | M&L for use & waste of formwork to square or rectangle shape and fair finished surfaces of concrete, to sides of pillars, post , struts etc complete all as specified and directed. |
| 8 | M&L for RCC M-25 (Design Mix) (using 20mm graded stone aggregate) as in columns etc complete all as specified and directed. |
| 9 | M&L for formwork to soffits of fair finished suspended slabs such as roof slabs, floor slabs, landings and similar work; n.exc 200mm thick(Horizontal or sloping) etc complete all as specified and directed. |
| 10 | M&L for RCC M-25 (Design Mix) (using 20mm graded stone aggregate) as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed. |
| 11 | M&L for use & waste of formwork finished fairto sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc. complete all as specified and directed. |
| 12 | M &L RCC (Design Mix) M-25 (using 20mm graded stone aggregate) inbeam bressummers, lintels over 1.5m span etc. complete all as specified and directed. |
| 13 | M&L TMT bars 10mm dia and over cut to length, bend to shape required including cranking, bending spirally for hookings for cols, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed. |
| 14 | M&L TMT bars but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders complete all as specified and directed. |
| 15 | Returning filling in including spreading levelling, watering and well ramming in layers n exc 25 cm complete all as specified. |
| 16 | Removing of excavated soil not exc 50m and depositing where directed at a level not exc 1.5 M above the starting point complete all as specified and directed. |
| 17 | M&L brick work with sub-class \"B\" bricks, straight or curved on plan exc 6 m mean radius built in cement mortar 1:4 complete all as specified and directed. |
| 18 | M&L brickwork with subclass ‘B’ bricks, straight or curved on plan to any radius in half brick thick walls built in cement mortar 1:4 complete all as specified and directed. |
| 19 | M&L for rendering 10 mm thick in cement mortar 1:6 on fair faces of brick work or cement concrete surfacesincluding finishing the surface even and smooth without using extra cement complete all as specified. |
| 20 | M&L for rendering 15 mm thick in cement mortar 1:4 on stone masonry surfaces or surface other than fair face of brick-work or on one side of lathing with using integral waterproofing compound @ 3% by weight of cement including finishing the surface even and smooth without using extra cement complete all as specified. Note -WPC shall be measured and paid separately. |
| 21 | M&L for rendering 5 mm thick in cement mortar 1:3 on fair faces of brick work or cement concrete surfacesincluding finishing the surface even and smooth without using extra cement on ceiling surfaces complete all as specified. |
| 22 | M&L for preparation of newly plastered surfaces of walls and applying two coats of cement base paintcomplete all as specified. |
| 23 | M&L for preparing newly plastered surfaces of walls, applying two coats of distemper oil emulation, white of tinted complete all as specified and directed. |
| 24 | M&L for preparing newly plastered surfaces of ceilings, applying three coats of white wash complete all as specified and directed. |
| 25 | M&L for hardcore of gauge not exceeding 63 mm of broken stone, deposited, spread and levelled in layers not exce 15 cm thick, watered and rammed to a true surface complete all as specified and directed. |
| 26 | M&L 75 mm thick cement concrete 1:4:8, type D-2 (using 40 mm graded stone aggregate) in sub base of flooring complete all as specified and directed. |
| 27 | M&L 25 mm thick PCC 1:2:4, type B-1 (using 20 mm graded stone aggregate), including finishing surface of concrete topping even and rough as sub base/ flooring complete all as specified. |
| 28 | M&L for machine cut Kota stone slab flooring 20-25mm thick over 20mm thick cement screed bed in cement mortar 1:3laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed. |
| 29 | M&L Kota stone slab 20-25mm thick in riser of steps, skirting, dado and pillar laid including 15mm thick rendering in cement mortar 1:4and jointed complete all as specified and directed. |
| 30 | M&L non - skid ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exc 0.06 sqm but n.exc 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15 mm thick screed bed in cement and sand mortar 1:4, complete all as specified. |
| 31 | M&L glazed ceramic tile 450mm x 300mm and 6-7mm thick (coloured) on vertical surfaces such as skirting, dados etc set and jointed in neat cement slurry and pointed in coloured cement to match the shade of tiles over and including 10 mm thick plaster in cement mortar 1:4 complete all as specified. |
| 32 | S&F roof trusses, trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. complete all as specified and directed. |
| 33 | M&L preparation of new steel surfaces of any description over 10 cm width or girth and priming with redoxide zinc chrome and painting with two coats of synthetic enamel paint on Steel sheeting as in roofing complete all as specified. |
| 34 | M&L for pre- painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as etc complete all as specified. |
| 35 | M&L for pre-painted galvalume aluminium zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering /cladding to wall, fixed with self tapping screws complete all as specified and directed. |
| 36 | S&F 2nd class soft wood plain, solid, straight chowkhats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints complete all as specified and directed. |
| 37 | S&F factory made 35mm thickplain framed, panelled shutter (two panel) with lock rail and panel of 9mm BWP commercial ply or 12mm veneered particle board with commercial veneering onboth faces, the size of rail and stile (second classhardwood)as per IS-1003 (part-I), kiln seasoned and chemically pressure treated, complete all as specified and directed. |
| 38 | S&F factory made 2nd class soft wood glazed and skeleton shutters 35 mm thick, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc., sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24 (a) supplied and fitted to chowkhats complete all as specified and directed. |
| 39 | S&F factory made glazed and skeleton shutters thickness 30 mm,(2nd class softwood), open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc. sizes of members of shutters supplied and fitted to chowkhats if windows, ventilators, etc. are provided with stiles and rails as in SSR Part I, section specified 8 clause 8.24(b) complete all as specified and directed. |
| 40 | M&L for preparation of newly or previously untreated wooden surfaces of any description over 10 cm width or girth and priming with pink primer and applyingtwo coats of synthetic enamel paint on wooden surfacescomplete all as specified. |
| 41 | S&F 300mm long aluminium alloy, anodised sliding door bolt with hasp staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded section or cast aluminium alloy and fixed complete all as specified. |
| 42 | S&F stainless steel wire cloth 0.36mm nominal dia of wire and average wide of aperture 1.40mm and fixed with stainless steel wire staples etc complete all as specified and directed |
| 43 | S&F 3mm thicksheet glass, ordinary quality and glazing with oil putty in square n exc 0.5 sq. m in each pane complete all as specified and directed. |
| 44 | S&F factory made solid PVC door frame of size 50 mm x 47 mm made out of 5 mm plain colour PVC sheet reinforced with MS square tube, complete all as shown in drawing of relevant item in MES, schedule Part-II, 2010 complete all as specified. |
| 45 | S&F factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of MS tubes for top & bottom rails MS frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail, panelling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement complete all as shown in drawing of relevant item complete all as specified and directed. |
| 46 | S&F steel ventilators with top hung shutter including hinges steel peg stay, squares no.exc 0.50 Sqm in each pane complete all as specified and directed. |
| 47 | S&F 3mm thick figured glass, pin head type and glazing with oil putty in squares n exc 0.5 sq. m in each pane complete all as specified and directed. |
| 48 | S&F butt hinges, 100 mm long medium weight, cold rolled mild steel, ISI marked complete all as specified. |
| 49 | S&F butt hinges, 75 mm long medium weight, cold rolled mild steel, ISI marked complete all as specified. |
| 50 | S&F butt hinges, 50 mm long medium weight, cold rolled mild steel, ISI marked complete all as specified. |
| 51 | S&F 150mm long aluminium anodised, barrel tower bolt ISI marked complete all as specified. |
| 52 | S&F 100mm long aluminium anodised, barrel tower bolt ISI marked complete all as specified. |
| 53 | S&F 150mm long aluminium anodised cast typealuminium handle SI marked complete all as specified. |
| 54 | S&F 100mm long aluminium anodised cast typealuminium handle SI marked complete all as specified. |
| 55 | S&F for PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls for 110 mm bore of pipe complete all as specified and directed. |
| 56 | S&F for PVC (SWR) floor trap, plain with grating including jointing with solvent cement 75 mm bore complete all as specified. |
| 57 | S&F for PVC (SWR) gully trap, plain with grating including jointing with solvent cement 110 mm bore complete all as specified. |
| 58 | S&F in repairs water closet (Orissa pattern) complete including provision of lime concrete bedding including vitreous China squatting pan, ‘Orissa’ pattern, size 580mm x 440 mm white, with integral foot rests (excluding flushing cistern and flush pipe) complete all as specified and directed. |
| 59 | S&F PVC valve less, symphonic action type, flushing cistern of 10 ltrs capacity, low level, white, with inlet, ball valve, float and handle complete all as specified and directed. |
| 60 | S&F 600mm x 450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick commercial quality plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete supplied and fixed , all as specified. |
| 61 | S&F 110mm bore PVC (SWR) pipe single socket any length with rubber ring joints laid in trenches or in floors complete all as specified. |
| 62 | S&F 75mm bore PVC (SWR) pipe single socket any length with rubber ring joints laid in trenches or in floors complete all as specified. |
| 63 | S&F 110mm bore PVC (SWR)bend, plain including jointing with solvent cement complete all as specified. |
| 64 | S&F 100mm bore PVC (SWR) single \"T \"any radius, complete all as specified and directed. |
| 65 | S&F 110mm bore PVC (SWR) vent cowl, plain including jointing with solvent cement complete all as specified. |
| 66 | S&F 500 ltrs capacity rotational moulded triple layered polyethylene in white coloured ISI marked water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position complete all as per specified and directed. |
| 67 | S&F second class softwood plain fillets square, rectangular or triangular in section, wrought secured with screws, cross sectional area exc 13 Sqcm and n.exc 25 Sqcm complete all as specified and directed. |
| 68 | S&F second class softwood plain fillets square, rectangular or triangular in section, wrought secured with screws, cross sectional area exc 3 Sqcm and n.exc 6 Sqcm complete all as specified and directed. |
| 69 | M&L for 4mm thick veneered decorative plywood, grade 1 (with BWR resin) with decorative face veneers on one face has decorative veneer fixed with nails to timber frame work in ceiling etc. complete all as specified and directed. |
| 70 | S&F vitreous china wash basin, white, flat back, size 580mmx450mm (for Hospital use) excluding taps, waste, chain and plug and porcelain stopper but including brackets etc complete all as specified and directed. |
| 71 | S&F soap dish chromium plated, fixed to plugs with chromium plated brass screws, complete all as specified and directed. |
| 72 | M&L 75mm thick PCC 1:3:6, type C-2 (using 20mm graded stone aggregate) as in plinth protection and similar works including finishing the surface of concrete topping even & fair, without using extra cement complete all as specified. |
| 73 | S&Ffor4 mm thickfigured glass pin head type andglazing with oil putty in squares n.exc 0.5 sqm in each pane complete all as specified and directed. |
| 74 | Supply only integralwater proofing compound. |
| 75 | M&L for use & waste of formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/ PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wideetc complete all as specified and directed. |
| 76 | S&F steel door including projecting type hinges, steel handle, complete, with glazing bars, dovetailed or welded complete all as specified and directed. |
| 77 | S&F PVC connection 15 mm size, of length 450 mm, with PTMT nuts supplied and fixed complete all as specified. |
| 78 | Excavation in post holes (or similar holes) each n.exc 0.5cum getting out, returning, filling in and ramming earth/broken rubble mixed with earth around, in layers n.exc 25cm, watering and removing surplus soil to a distance n.exc 50m and making good surface in hard/dense soil complete all as specified and directed. |
| 79 | S&F framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and directed. |
| 80 | S&F plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment Fe-290 (Gde E-165) complete all as specified and directed. |
| 81 | M&L for providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-30 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc. of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of coarse sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling he joints with fine sand and cutting of paver block as per required size and pattern, finishing and sweeping extra sand complete all as specified and directed. |
| 82 | M&L for providing cement concrete 1:2:4, type B-1(using 20mm graded stone aggregate) as in roof kerbs or mud stop, rounded or chamfered on edges complete all as specified and directed. |
| 83 | Demolition of brick work, PCC block masonry, stone masonry or boulder masonry built in cement mortar complete all as specified and directed by Engr -in-Charge |
| 84 | M&L brick work with sub class \"B\" (old size) bricks, straight or curved on plan to any radius built in cement sand mortar 1:6,complete all as specified and directed. |
| 85 | Taking down cement plaster of any description including racking out joints, hacking for key, scrubbing down with water etc. complete all as specified and directed. |
| 86 | M&L for precast cement concrete hollow block masonry exc. 10 cm in width 1:2:4, type B1(using 16 mm graded stone aggregate as per IS383) and setting in cement mortar 1:4 all as specified and directed |
| 87 | M&L for rendering 15 mm thick in cement mortar 1:4 on fair faces of brick work or cement concrete surfaces including finishing the surface even and smooth without using extra cement including mixing of water proofing compound, complete all as specified and directed. NOTE:- Water proofing compound shall be measured separately. |
| 88 | M&L for complete removal of existing treatment on old wall surfaces & finishing walls with acrylic smooth exterior paint of required shade (two or more coat applied @ 1.67 Itr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) new surfaces or old decorated surfaces complete all as specified and directed by Engr-in-Charge. |
| 89 | S&F mild steel work as in angle iron posts or struts in fencing and for making waterways, grills etc including cutting tops to shape as directed, drilling holes notching for wire etc flat iron fillets (for securing wire mesh etc) including all necessary drilling, bolting or riveting etc and similar work conforming to FE-290 Gde E-165, complete all as specified & directed. |
| 90 | S&F galvanised 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins etc as complete all as specified & directed. |
| 91 | S&F10 user LLDPE septic tank conventional to carry sewage and sludge water, excavation in any type of soil, PCC 1:4:8 below foundation, vent shaft connection etc complete all as specified and directed. |
| 92 | Construction of soakage wells excavation, in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of M-25 concrete including intercepting chamber and screen chamber made of Brick masonry in CM, RCC cover slab in M25/ SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats of size 2.4m dia and 3m depth complete all as specified and directed. |
| 93 | M&L for plain cement concrete 1:3:6, type C-2 (using 40mm graded stone aggregate) as in foundations, filling and mass concrete complete all as specified and directed. |
| 94 | M&L plain cement concrete 1:2:4, type B-1 (using 12.5 mm graded crushed stone aggregate) as incopingsetc complete all as specified and directed. |
| 95 | M&L for reinforced concrete pipes, 150mm, Class NP2, laid in trenches, jointed complete with and including collars complete all as specified and directed |
| 96 | M&L concrete bed to drain pipes 150 mm bore in PCC 1:3:6, type C2 (using 40 mm graded crushed stone aggregate) including packing under, and haunching against the sides of pipes after they are laid and tested including forming cradles complete all as specified and directed. |
| 97 | M&L for cement concrete 1:2:4, type B-1 (using 20mm graded stone aggregate) as in surface channels, drains etc, complete all as specified and directed. |
| 98 | M&L pre-cast RCC 1:2:4, type B1 (using 20mm graded stone aggregate) as in cover slab for manhole etc including necessary form work complete all as specified and directed. |
| 99 | S&F3-layer PP-R Polypropylene random copolymer) concealed pipesof 16mm outer diaSDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings fixed complete to walls, ceilings or in floors etc complete all as specified and directed. |
| 100 | All as per ser item No 99 here-in-before but 20mm outer dia. |
| 101 | Lagging to 20mm bore pipe exposed PPR tubing all around (including provisions of lagging on pipe fitting i.e., unions, elbows, nipples, tees etc) with 40mm thick bonded mineral wood performed \"SNAP ON\" pipe section of density 144 Kg/Cum confirming to IS-9842 with chicken mesh wire netting 25 gauge, 20mm mesh with 0.01 mm aluminium foil complete all as specified and directed. |
| 102 | S&F bib taps, cast copper alloy chromium plated fancy type with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed. |
| 103 | S&F chromium plated shower roses 125mm dia with or without swivel joints, any size, including fixing to steel pipe or union complete all as specified and directed. |
| 104 | S&F stop valves, cast copper alloy but fancy type, chromium plated with long shank and cup (concealed type), screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed. |
| 105 | S&F brass CP mixer for mixing hot & cold water screwed down for iron pipe and fixed to 15mm bore of pipe complete all as specified and directed. |
| 106 | S&F gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed to 20mm dia bore pipe complete all as specified and directed. |
| 107 | Supply and erection of steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts and screws as specified type 410 SP-31 (09 metres long) including two coats of black bituminous paint internally throughout and externally upto embedded portion and applying two coats of synthetic enamelpaint over a coat of red oxide primer with black and white strip of 30 cm each upto 1.50 metre height and two coats of aluminium paint over a coat of red oxide primer externally on remaining exposed surface after preparation of surface and eraction in position, complete all as specified anddirected. Note:- Cost of excavation and earth work, PCC for foundation and coping, channel, clamps nuts, bolts shall be deemed included in quoted rate. |
| 108 | S&F 100 W LEDNew generation energy saving & environmental friendly long life Versatile pressure die-cast aluminium IP66 roadway luminaire with high powerLED as light source and electronic driver suitable for pole dia up to 58 mm complete all as specified and directed. |
| 109 | S&F GI pipe, bracket for street light fittings made out of GI Pipe medium grade 1.20 m long bent to required angle/shape with and including necessary clamps, nuts, bolts & washers of suitable size and two coats of aluminium paint with a base coat of red oxide primer complete all as specified and directed. |
| 110 | S&F PVC insulated unsheathed copper cable of size 1.5 Sqmm 3 core FRLS PVC for service connections from junction box to light fitting complete all as specified and directed. |
| 111 | S&F loopin loopout fuse junction box made out of thermo plastic polycarbonate with IP 66/67 weather proof for outdoor installation (with knockouts of cable entry) protection with terminals and locking screw fitted with 3 phase with neutral copper Bus Bar, 415 Volts, 50Hz and6A MCB SP, suitable for cables off sizes and fixingon steel tubular pole at a height not less than 1.5m above ground levelwith the help of clamps two nos of F1 20 x 3 mm and suitable nuts and bolts,complete all as specified and directed. |
| 112 | Supply and laying GI pipe 50mm dia medium grade for cable protection on pole/road/culvert crossing and for on pedestal complete all as specified and directed. |
| 113 | M&L earthing complete with galvanized earth plate electrode 600mm x 600mm and 6 mm thick buried directly in ground vertically to a depth of not less than 2.25 mtr below ground level connected to 32 x 6mm earth strip with nuts, bolts and washers made out of galvanized iron mild steel and 40 mm dia GI pipe \"light grade\" for protection of earth lead and connected to control board or main switch or as directed by Engineer -in-Charge including earthing pit in PCC 1:3:6 type C1 for chamber &pre-cast RCC coverof size 380 x 380 x 40 mm with one handle made out of 8 mm dia round bar, 20 mm dia GI pipe light grade for watering funnels, wire mesh and provided charcoal or coke of alternative layers of 15 cm includingnecessary earth work as excavation, returning filling & removal etc complete all as specified and directed. |
| 114 | M&L earthing complete with galvanized earth plate electrode 600mm x 600mm and 6 mm thick buried directly in ground vertically to a depth of notless than 2.25 mtr below ground level connected to 4mm GI Wire mm earth strip with nuts, bolts and washers made out of galvanized iron mild steel and 40 mm dia GI pipe \"light grade\" for protection of earth lead and connected to control board or main switch or as directed by Engineer -in-Charge including earthing pit in PCC 1:3:6, type C1 for chamber &pre-cast RCC coverof size 380mm x 380mm x 40 mm with one handle made out of 8 mm dia round bar, 20 mm dia GI pipe light grade for watering funnels , wire mesh and provided charcoal or coke of alternative layers of 15 cm includingnecessary earth work as excavation, returning filling & removal etc complete all as specified and directed. |
| 115 | Supply and laying XLPE insulated PVC FRLS, armoured heavy duty electric cable with aluminium conductor, 1100 Volts grade, cross-sectional area, galvanized steel strip or wire armoured, of size25 Sq mm 4 core complete all as specified and directed. |
| 116 | Supply and laying XLPE insulated PVC FRLS, armoured heavy duty electric cable with aluminium conductor, 1100 Volts grade, cross-sectional area, galvanized steel strip or wire armoured, of size35 Sq mm 3.5 core complete all as specified and directed. |
| 117 | Supply and laying XLPE insulated PVC FRLS, armoured heavy duty electric cable with aluminium conductor, 1100 Volts grade, cross-sectional area, galvanized steel strip or wire armoured, of size16 Sq mm 2 core complete all as specified and directed. |
| 118 | Supply and laying of burnt clay building bricks, sub-class B (old size) designation 75 laid flat in tranches for cable protection with wide equal to length of brick, complete all as specified and directed. |
| 119 | M&L for dry sand cushioning to under ground electric cable on layer of 8 cm thick before laying the cable and second layer of 15cm thick after laying the cable all as specified in clause 19.75 of MES schedule part-1 complete all as specified and directed.Note:- (i) Sand shall be fine sand as specified for plastering.(ii) Only ground thickness shall be measured for payment. |
| 120 | Supply, installation, commissioning & testing of LT panel board (Main Panel) outdoor type fabricated out of 3.15 mm thick CRCA Sheet, dust and vermin proof, totally enclosed metal clad, double doortype accessible from front and rear side both with locking arrangement 3 phase 1.5 Sqmm single core copper wire system at AC 440 V, 50 HZ with colour coded aluminium bus bar of rated current capacity 200 Amps complete applied with two coats of synthetic enamelledpaint over a coat of anti corrosion primer and mounted on angle iron of size 50mmx50mmx6 mm grouted in PCC foundation including earth work and excavation complete suitable to accommodate the following accessories : - Supply and fabricated LT distrubution panel board with 3.15 mm thick CRCA sheet.Aluminium busbar 4 strip with Coloured R,Y,B & Neutral of size (32x6) mm. Angle iron for frame work of size 50mmx50mmx6mm thick for panel mountingINCOMING TPNMCCB 4 POLE63 Amp,50Hz 415 Volts OUTGOING MCBsTPN 32 Amp, with repturing capacity16 K - 02 NosIndicator LED lamp R,Y,B Digital Volt meter 0-500 Volts with selector switchDigital Ammeter 0-400 Amps with suitable CT,sStreet lightASTRONOMICAL timer with contactor 32 Amps TP, and 40Amps TPN = 02 Nos NOTE : Cost for construction of plateform for panel of brick masonary work in CM 1:6 with foundationPCC 1:4:8 type D-2including plaster work, PCC copping 1:2:4 (using 40 mm thick stone aggerate), deemed to be included in the item rate. No extra payment will be made. |
| 121 | M&L for point wiring in PVC conduit, concealed with 1.5sqmm size multi stranded FRLS copper conductor cable 1.5 sqm including clamps, screws guttier/plug etc PVC unsheathed cable into and including MS/GI sunken board with Bakelite sheet and PVC insulated FRLS cable of size 1.5 Sqmm as earth continuity conductor for, one light point/fan point/ex fan point controlled by one 5 Amps switch one way complete all as specified and directed. |
| 122 | All as per ser item No 121 here-in-before but one 3 pin 5 Amps switch socket outlet on dependent board |
| 123 | All as per ser item No 121 here-in-before but one one 3 pin 5 Amps switch socket outlet on same board with accessories. |
| 124 | M&L for point wiring in PVC conduit concealed with 2.5 Sqmm size multi stranded FRLS copper conductor cable including clamps, screws guttier/plug etc PVC unsheathed cable into and including MS/GI sunken board with Bakelite sheet and PVC insulated FRLS cable of size 2.5 Sqmm as earth continuity conductor, all as specified. |
| 125 | S&F switch piano flush type, single pole, one way 6 Amps 240 Volts, complete all as specified and directed |
| 126 | S&F switch piano flush type, single pole, 15 Amps 240 Volts, complete all as specified and directed |
| 127 | S&Fsocket outlet 2 in 1, 3 pin, 5 Amps, flush type complete with gang box all as specified and directed. |
| 128 | S&Fsocket outlet 2 in 1, 3 pin, 5 and 15 Amps, flush type complete with gang box all as specified and directed. |
| 129 | S&F ceiling rose 3 terminal / PVC/ polycarbonate, isolated body all as specified and directed. |
| 130 | S&F lamp holder, PVC/ polycarbonate type with back plate suitable for batten fitting complete all as specified and directed. |
| 131 | S&F in repairs distribution board, SPN 8 way, double door complete all as specified and directed. |
| 132 | S&F in repairs distribution board, SPN 4 way, double door complete all as specified and directed. |
| 133 | S&F in repairs MCB,DP 40 Amps 240 Volts\"B\" curve, complete all as specified and directed |
| 134 | S&F MCB single pole 6-32 Amps 240 Volts \"B\" curve complete all as specified and directed |
| 135 | S&F exhaust fan/brisk air fan of size 300 mm sweep, non metallic complete all as specified and directed. |
| 136 | S&F static water tanks 25 ltrs capacity complete all as specified. |
| 137 | S&F ceiling fan BLDC 1200mm sweep 230 Volts 50 Hzs copper wound complete all as specified and directed. |
| 138 | S&F LED lamp 10W complete all as specified and directed. |
| 139 | S&F LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed. |