| 1 | Providing comprehensive annual maintenance periodical/preventive maintenanceincluding annual maintenance of cooling appliances ( Split type Air Conditioners, Water coolers, Refrigerators and Deep Freezers) as per manufacturer specificationby providing one AC/Refrigeration mechanic including replacement ofcomponents as listed in subsequent items here in after. The maintenance of cooling appliances includes the following:-(a) Cleaning of coil unit with dust blower, lubricate the indoor and outdoor fan motor with oil.(b) Cleaning of air filters, indoor unit grills & filters through air blower.(c) Checking and cleaning the drain connection and air filter periodically, washing of coil with ventiklean solution once in a contract period.(d) Check and replace the refrigerent pipe once in a contract period or as and when required.(e) Check and repair the minor electrical fault in incoming supply.(f) Check and replace the water PVC pipe.(g)Replacementof faulty spares/components(h) Carry out the monthly, quarterly and annual maintenance of all cooling applicances of any make & capacity with job card and making the Cooling Appliances functional(Attending 3 Complaints shall be measured as one job) |
| 2 | Supply only the following new sparesfor 1.5 / 2.00 Ton CapacitySplit type AC including testing and commissioning etc complete all as directed. |
| 3 | Capacitor60 MFD. |
| 4 | Air filters. |
| 5 | Condenser fan motor 1.5 HP with blade set . |
| 6 | Blower fan motor 1.6 HP with blade set. |
| 7 | Blower with circular leaf. |
| 8 | Copper condenser coil unit (for A/C) |
| 9 | Copper cooling coil unit (for A/C) |
| 10 | Indoor motor capacitor 2.5 MFD. |
| 11 | Stainer tube (copper) |
| 12 | Capillary tube (copper) |
| 13 | Non return valve (For gas top up charging) |
| 14 | Remote control suitable for Non inverter model Split AC. |
| 15 | Remote control suitable forinverter model Split AC. |
| 16 | Electronic components for repairs to PCB |
| 17 | PCB board suitable for Non inverter model split AC 1.5/2.0 TR |
| 18 | PCB board suitable for indoor unit of Inverter model split AC 1.5/2.0 TR . |
| 19 | PCB board suitable for outdoor unit of Inverter model split AC 1.5/2.0 TR . |
| 20 | Copper pipe of size 1/2\" for suction line with foam insulation |
| 21 | Copper pipe of size 1/4\" for discharge line with foam insulation |
| 22 | Swing Motor for indoor unit |
| 23 | Outdoor unit stand |
| 24 | Condenser fan motor blade |
| 25 | Indoor Motor blower |
| 26 | Supply and fixPVC insulated unsheathed cables of size 2.5 sqmm 3 core multi-stranded Copper conductor wire suitable for geysers complete all as specified and as directed. |
| 27 | Supply & Fix 3 pin 15 Amps plug top, 250 Volts complete all as specified an directed. |
| 28 | Supply only the new following items for water cooler 40/80 Litres capacityincluding testing and commissioning etc complete all as directed. |
| 29 | Relay unit |
| 30 | PVC float valves , high pressure with polythene float and fly nut screwed to iron pipe or ferrule of bore 15 mm. |
| 31 | Thermostatasssembly |
| 32 | Water tap suitable for water cooler. |
| 33 | Starting Capacitor 80-100 MFD |
| 34 | Running capcitor 36 MFD |
| 35 | Condenser fan motor 1.6HP with blade set |
| 36 | Over load protector (OLP) |
| 37 | Supply only new compressor including pumping out oil, cleaning the refrigeration system with CO2 and charging refrigerant gas (M-22/F-22) providing NRV for further topping up of gas and re-fixing in the position including complete testing and commissioning all as directed for the following appliances :-Note: Regrigerant gas will be measured and paid separately. |
| 38 | Split type AC 1.5 Ton capacity. |
| 39 | Split type AC 2.0 Ton capacity. |
| 40 | Water cooler 40/80 Litres capacity . |
| 41 | Repair to stabilizer of capacity 4 or 5 KVA capacity by removing the old / burnt transformer and replaced with new transformer complete all as directed. |
| 42 | Repair to stabilizer by removing the old / burnt relay board suitable for Voltage stabilizer of capacity 4 KVA / 5 KVA capacity |
| 43 | M & L Painting complete with super enamel paint of approved colour for water coolerall as specified and directed. |
| 44 | Supply and fix condensed water PVC flexible pipe of standard quality of suitable size fixing with suitable clamps on wall for split type AC of capacity of 1.5/2.0 Ton complete all as specified and as directed. |
| 45 | Supply only R22 /R32 /R410 Gas complete all as specified and directed. |
| 46 | Supply only R134a Gas complete all as specified and directed. |
| 47 | Dismantling and disconnecting carefully the existing split AC 1.5/2.0 Ton capacity after disconnecting the copper pipe and electrical connection, Cleaning the refrigeration system with CO2 and fixing in a new position including, brazing, testing and commissioning complete all as directed for the following cooling appliances :-NOTE : Refrigerent gas used for filling/top up shall be measured and paid separately under respective item. |
| 48 | Supply only 2 nos of1/2\" x 3/8\" Foam Heat Insulated Pipe Black for Air Conditioner |
| 49 | Materia and labour for making good of surface withsealing the cavity /hole drilled to facilitate tubing, using white cement/POP and cleaning the surface to match with existing surface complete. |
| 50 | Material only for following items for refrigerators/Deep Freezers 320 Litres capacity including testing and commissioning etc complete all as directed. |
| 51 | (a) Relay unit. |
| 52 | (b) Thermostat assembly. |
| 53 | (c)Condenser coil |
| 54 | (d) Freezer for double door refrigerator |
| 55 | Supply only new compressor including pumping out oil, cleaning the refrigeration system with CO2 and charging refrigerant gasproviding NRV for further topping up of gas and re-fixing in the position including complete testing and commissioning all as directed for the following appliances :- NOTE : Refrigerent gas used for filling/top up shall be measured and paid separately under respective item. |
| 56 | (a) Refrigerators upto 320 litres capacity. |
| 57 | M & L Painting complete with super enamel paint of approved colour for Refrigeratorall as specified and directed. |
| 58 | Periodical checking (Quarterly) cleaning maintenance and repair, cleaning of all parts / fittings, washing out of condensing unit with water to remove deposition of materials checkingall parts for smooth functioning and carrying out servicing & lubricating of all parts ,checking and tightening electrical connections and ensuring complete unit in perfect working condition of Window ACs, Split type ACs, Water Coolers, Refrigerators & Deep Freezersfor smooth functioning including replacement of defective spare parts such as starting capacitor, running capacitor,fan motor capacitor, relay, filter element, including gas charging(R 22 /Freon gas) with leak testingand any other spare parts required for smooth operation , which are not listed in the schedule of spares mentioned below for the following units :- |
| 59 | (a) Split type ACs of capacity 2 TR PTC(K)=10 NoNote :The unit \" Each\" mentioned in column 5 shall means \" periodical maintenance of one unit per month\" |
| 60 | (b)Split type ACs of capacity 1.5 TR21 Nos Note :The unit \" Each\" mentioned in column 5 shall means \" periodical maintenance of one unit per month\" |
| 61 | Dismantlingtheunserviceable uncut hermitically sealed compressor from the split type AC unit and replacement with factory reconditionedhermitically sealed compressor ofany Make includingtransportingfor 1.5 Ton capacity and including servicing the entire unit complete all as specified and directed. Note : Old unserviceable compressor shall be taken into credit. |
| 62 | All as per Sl item No 61 herein before but of 2.0 Ton capacity. |
| 63 | M&L taking out defective Magnetic Contactor /relay 1 Pole, 30 A of split type AC of existingMake/Model up to 2 TR Capacityfor repair and refixing to its original place after carry out necessary repair and testing complete all as specified and directed by Engr-in-charge. |
| 64 | Repair/Replacement of Unserviceble Sensor (AC and DC Volt) |
| 65 | Repair/Replacement of Unserviceble Electronic PCB board. |
| 66 | All as per Sl item No 63 herein before but fan motor 1/6HP capacity and including servicing the entire unit. |
| 67 | All as per Sl item No 63 herein before but suction valve, |
| 68 | All as per Sl item No 63 herein before but discharge valve |
| 69 | All as per Sl item No 63 herein before but fan blade set |
| 70 | All as per Sl item No 63 herein before but wiring kit complete |
| 71 | Repair/Replacement of new indoor unit for split type AC 1.5 ton capactiy and including servicing the entire unit of any make complete all as specified and directed as per the existing make and model. |
| 72 | Repair/Replacement of new outdoor unit for split type AC 1.5 ton capactiy and including servicing the entire unit of any make complete all as specified and directed as per the existing make and model. |
| 73 | Matrial and labour for Spray painting to the whole out door unit of split type air conditioner 1.5/2.0 Ton with two coats of synthetic enamel paint after cleaning the unit assemblywith caustic soda wash complete and including servicing the entire unit all as specified and directed. |
| 74 | Taking out the voltage stablizer of any make and ofcapacity 4/5 KVA from site and transporting to servicingcentre to detect /identify the nature of defects/repairs and reassembling after repair/servicing and commissioning at site including testing the same to the entire satisfaction of Engineer-in-Chargecomplete all as specified and directed. |
| 75 | Supply and fixing relay set of two for voltage stabilizer up to 5 KVA capacity complete all as specified and directed. |
| 76 | All as per Sl item No 75 here-in- before but PCB (printed circuit board). |
| 77 | All as per Sl item No 75 here-in -before but 3 core flexible cord 2.5 Sqmm. |
| 78 | All as per Sl item No 75 here-in- before but indicating lamp. |
| 79 | All as per Sl item No 75 herein before but push cock brass chromium plated of size 15mm. |
| 80 | S&F for sub main wiring/power wiring with 2 runs of 4 sqmm PVC insulated stranded copper conductor FRLS cable and one run of 4sqmm copper FRLS cable as earth lead in PVC conduit all as specified. Note: Two runs of wire, one run of conduit and one run of earth conductor shall be measured as one unit length. |
| 81 | Supply and fix copper pipe 5/8\" dia for all summer appliances of any capacity including dismantling the unserviceable pipe complete all as specified and directed. |
| 82 | Supply & Fixing 4 sqmm copper conductor PVC round sheathed (flexible) industrial cable complete all as specified and directed. |
| 83 | Supply and fix two pin sheet metal earth plug top and metal clad socket 20 Amps capacity complete all as specified and directed. |
| 84 | Supply and fix Sheet metal enclosures with socket plug top and MCB SP 20A, 240 volts, with a two pin and earth plug socket complete with one single MCB 20 Amps, 240 volts (for AC ) including taking down old unserviceable old unserviceable Sheet metal enclosures with socket plug top complete all as specified and directed. |
| 85 | Supply and fixing amp rating 240V, 10KA \"C\" curve miniature circuit breaker (MCB) of SP 6-32 A current carrying capacity in the MCB DB complete with connection testing and commissioning |
| 86 | S&F Rigid non-metallic 20mm PVC conduit exclusive of boxes (junction/ terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc. |