| 1 | Taking down Cast iron/AC/PVC of any dia and size fixed on wall or floor at any floor/ any height/ any location including all fittings complete all as specified. |
| 2 | S&F 100 mm dia sand cast CI soil waste pipe in any length with ears and jointed with neat cement paste fixed to wall at any floor/ any height/ any location including all fittings complete all as specified and as directed by Engr-in-Charge |
| 3 | S&F 75 mm dia sand cast CI soil waste pipe in any length with ears and jointed with neat cement paste fixed to wall at any floor/ any height/ any location including all fittings complete all as specified and as directed by Engr-in-Charge |
| 4 | M&L in repair 100mm cast iron Nahani trapwith grating including jointingto waste pipe fixed in cement concrete type B1 (1:2:4)complete all as specified and as directed by Engr-in-Charge |
| 5 | S&F in repair 100 mm dia sand cast CI bend of any radius with ovel access door and jointed with neat cement pastefixed to wall or roof at any floor/ any height/ any location including all fittings complete all as specified and as directed by Engr-in-Charge |
| 6 | S&F in repair 75mm dia sand cast CI bend of any radius with ovel access door and jointed with neat cement pastefixed to wall or roof at any floor/ any height/ any location including all fittings complete all as specified and as directed by Engr-in-Charge |
| 7 | S&F in repair 100 mm dia CI sand cast branch piece single branch of any radius with ovel access door and jointed with neat cement pastefixed to wall or roof at any floor/ any height/ any location including all fittings complete all as specified and as directed by Engr-in-Charge |
| 8 | S&F in repair 100 mm dia branch piece double (equal or unequal) ordinary or inverted or with parallel brach and jointed with neat cement pastefixed to wall or roof at any floor/ any height/ any location including all fittings complete all as specified and as directed by Engr-in-Charge |
| 9 | S&F in repair 75 mm dia branch piece single branch of any radius with ovel access door and jointed with neat cement pastefixed to wall or roof at any floor/ any height/ any location including all fittings complete all as specified and as directed by Engr-in-Charge |
| 10 | S&F in repair 75 mm dia branch piece double (equal or unequal) ordinary or inverted or with parallel brach and jointed with neat cement pastefixed to wall or roof at any floor/ any height/ any location including all fittings complete all as specified and as directed by Engr-in-Charge |
| 11 | Cutting holes in bricks or RCC walls exce half brick built in cement mortar including making good after inserting and setting pipes all as specifiedand as directed by Engr-in-Charge |
| 12 | Jointing only cast iron pipes and fittingsAC pipesin repair with cement joints forpipes 100mm dia upto ground/stilt plus 16th floors including removing of tree, complete all as specified and directed. |
| 13 | Demolition of Cement concretein any description and in any position not other wise specifically provideddirected by Engineer-in-Charge and removal of debris to out side MD land. |
| 14 | M&L for PCC B2 1:2:4 100 mm th (using 40mm stone aggregate) for floor finishes complete all as specified and as directed. |
| 15 | S&F in repair stainless steel grating cover fixed in repairs suitable for 100mm dia nahani trap fixed with cement complete all as specified and as directed by Engr-in-Charge |
| 16 | S & F in repair Cast iron floor trap 75mm dia, with ss grating including jointingto waste pipe fixed in cementconcrete type B-1 (1:2;4) all as specified |
| 17 | S&F in repair cast iron cowl suitable for 75mm dia pipe complete all as specified and as directed by the Engineer-in-Charge |
| 18 | S&F in repair cast iron cowl suitable for 100mm dia pipe complete all as specified and as directed by the Engineer-in-Charge |
| 19 | Dismantling floor hearth or wall tiling including cement mortar beddingremoving serviceble tiles to store and rubbish off the permises. |
| 20 | M & L for Non-Skid coloured ceramic tiles 7 to 8mm thick (square/rectangular) area of each tiles exceeding 0.06sqm but not exceeding 0.11 sqm over & including 15mm thick Screed bed or bedding layer in CM 1:6 for laying floor finishes, set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and as directed by the Engineer-in-Charge |
| 21 | M & L for Glazed whiteceramic tiles of size 300x200x 6 to 7mm laid on vertical surface such as dado/skirting over cement mortar backing coat, set jointed in neat cement slurry and pointed in white or colouredcementincluding 10mm thick bedding layer in CM 1:4, complete all as specified and as directed. |
| 22 | S&F in repairs white vitreous china wash down water closet pan (pedestal pattern) with PVC seat cover withmild steel chromium plated or aluminised hinging device including connection to drowm pipe PVC connection andflushingpipe all as specified. |
| 23 | Supply and Fixed 10 ltr capaciaty PVC low level flushing cistern with dual flushing system including brackets 10 litre capacity with 32mm bore polythene flush pipe of sufficient lenght including internal fitting (valve less syphonic)etc. complete fixed as in repairs. |
| 24 | Taking down rain water pipes/PVC pipes/cemented pipe (any size or pattern) including all fittings, heads, shoes, bends, swan necks, etc.,at any height, any location, any floor including all necessary scaffolding complete all as specified and as directed by Engineer-in-Charge. |
| 25 | S&F 160mm dia PVC (SWR) pipes single socketed,in any length with rubber ring joints, fixed in wallincluding GI clamps of approved shape and size approved by GE at any height, any location, any floor including necessary scaffoldingcomplete all as specified and as directed by Engineer-in-Charge. |
| 26 | S&F in repair 160mm dia PVC (SWR) bends/shoes any radius fixed to pipe at any location/height including necessary scaffolding etc complete all as specified and as directed by Engineer-in-Charge. |
| 27 | S&F 110mm dia PVC (SWR) pipes single socketed,in any length with rubber ring joints, fixed in wallincluding GI clamps of approved shape and size approved by GE at any height, any location, any floor including necessary scaffoldingcomplete all as specified and as directed by Engineer-in-Charge. |
| 28 | S&F in repair 110mm dia PVC (SWR) bends/shoes any radius fixed to pipe at any location/height including necessary scaffolding etc complete all as specified and as directed by Engineer-in-Charge. |
| 29 | S&F 75mm dia PVC (SWR) pipes single socketed,in any length with rubber ring joints, fixed in wallincluding GI clamps of approved shape and size approved by GE at any height including necessary scaffoldingcomplete all as specified and as directed by Engineer-in-Charge. |
| 30 | S&F in repair 75mm dia PVC (SWR) bends/shoes any radius fixed to pipe at any location/height including necessary scaffolding etc complete all as specified and as directed by Engineer-in-Charge. |
| 31 | Dismantling stone slabs and tiles of any description or thickness in floors, aprons etc. |
| 32 | Material and Labour for Polished granite stone slab 20mm thick(table rubbed and polished) in steps, jambs, pillar, window cills, cooking platformand like in cement mortar 1:4 incl pointing in white cement 1:2 using marble dust with admixture pigmentto match with shade of granite including moulding at front edgecomplete all as specified and as directed as in platforms.[Note :- Quality of granite all as approved by GE]. |
| 33 | S&F in repair vitrous china squatting pan \"Orrisa Pattern\" size 580x440mm white with integral foot rest including connecting and necessary provision of lime concret complete all as specified and directed by Engr-in-Charge |
| 34 | S&F in repair wash hand basin vitreous china white flat back or angle type of size 580mmx450mm including waste chain and plug and porcelain stopper, waste pipe, a pair of brackets or errecting standetc. complete all as specified and directed. |
| 35 | S&F Kitchen sinks with drainage board made of stainless steel 1 mm thick (SS grade 304 AISI 18/8) IS embosed (IS : 13983) gloosy finish ktichen sink with plugs, washeres and wastes including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460 mm bowl size 410 mm x 330 mm x 160 mm, as in repairs complete all as specified and as directed by Engineer in Charge. |
| 36 | M&L in repairs for framed brackets of angles, joist, channel, angle or tee sections fixed independently without connecting plates ect cut to shape (cut to ordinary length i.e within 20mm of the length indicated) drilled and cuntersunk for screws, including bending and welding as necessary, confirming to fe-410-0 or fe 310-0 including removing of old brackets and remove to store complete as specified and directed. |
| 37 | M & L for preparation of new or previously untreted steel surface of any description over 10 cm in width or girth and applying two coat synthetic enamel paint over a coat of red oxide primer ,complete all as specified and directed. |