| 1 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. |
| 2 | Supplying and fixing metal box of 150mm X 75mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 amps socket outlet and 5/6 amps piano type switch, connection, painting etc. as required. (For light plugs to be used in non residential buildings). |
| 3 | Supplying and fixing metal box of 180mm X 100mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 amps socket outlet and 15/16 amps piano type switch, connection, painting etc. as required. |
| 4 | Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc as required. 100 mm X 100 mm X 60 mm deep |
| 5 | Providing and fixing circular/ Hexagonal GI box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick GI sheet with its top surface hacked for proper bonding, top lid shall be screwed into the GI box by means of 3.3 mm dia round headed screws, one lock at the corners, clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing. |
| 6 | Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required. |
| 7 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. |
| 8 | 2 X 1.5 sq. mm + 1 x 1.5 sq. mm earth wire |
| 9 | 2 X 2.5 sq. mm + 1 x 2.5 sq. mm earth wire |
| 10 | 4 X 16 sq. mm + 2 x 6 sq. mm earth wire |
| 11 | Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required. |
| 12 | Supplying and fixing PVC batten/ angle holder including connections etc. as required. |
| 13 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 8 way Double Door |
| 14 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 8 way (4+24), Double Door |
| 15 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole |
| 16 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Double pole |
| 17 | Supplying and fixing Cable End Box (Loose wire box) (IP 43) suitable for following single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with testing and commissioning etc. as required. for 10 way, Double door SPN MCB DB |
| 18 | Supplying and fixing Cable End Box (Loose wire box)(IP 43) suitable for following triple pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete withtesting and commissioning etc. as required. For 8 way, Double door TPN MCBDB |
| 19 | Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. |
| 20 | Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. |
| 21 | Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/coke and salt as required. |
| 22 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. |
| 23 | Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cmlong down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS: 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise-75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. |
| 24 | Supply and fixing of LED tube light with heavy duty metal box type tube light fitting 1x22 watt. Suitable for up to 1 x 22 watt suitable for up to 1x 22 watt LED polycarbonate tube light complete in cluding tube suitable for both surface & suspended complete.2620 System lumens>120Lm/W, P.F>0.95, THD<10%, CRI>80, sheet thickness min 0.8 mm., tube with al. head sink >300V over voltage protection, 2.5 KV internal surge protection, with 5 year warrantee. |
| 25 | Supply and fixing of LED street light fitting with mandatory driver set having die cast al. body with tougtend glass/UV stablized PC cover and lenses suitable for 30 watt to 40 watt confirming ti IP 65/66 and IK 07 and above protection complete having company logo engraved complete in all respect including labour.3600-4800 System lumens, High power LED with lenses, 120Lm/W, P.F>0.95, THD<10% at full load, CRI>70, potted driver set in metal housing (Not circuitory) phase to phase protection at 440V,>300V over voltage auto cut and restart feature, 4 KV internal surge protection, with 5 year warrantee. |
| 26 | Supplying and fixing of 32 mm dia X 2.00 metres long G.I. pipe (medium class) bracket for mounting of fluorescent / HPMV / HPSV street light fitting on pole including bending the pipe to the required shape, 2 nos 40 mm X 3 mm flat iron clamps with nuts, bolts and washer, painting the flat iron with primer and finish paint etc. as required. |
| 27 | Supply and laying of 6 Sq. mm 2 core Aluminium conductor PVC insulated armoured served sheathed cables 1100 V Grade at a depth of 750 mm. below ground level over a cushion of 75 mm thick sand all around and protected with burnt bricks on sides and on top as directed by engineer in charge complete in all respect including excavation and refilling. the armouring of the cable shall be properly connected with the earth conductor by clamps etc. |
| 28 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 4 X 16 sq. mm (28mm) |
| 29 | S/f of 63 Amp. FP MCB 10 KA complete in all respect. |
| 30 | Supply of 10 Watt LED Bulb havells or equalivant |
| 31 | Supply of 230 mm Sweep metalic fresh Air fan havells or equalivant |
| 32 | Onload Changeover Switch 63 Amp. 415 V, 50 Hz, Side Handle Make:-Legrand, Havells or Eq. |
| 33 | Supply and fixing of fire extinguisher, ABC Type 4.00 kg. capacity (ISI Marked IS : 15683 & TAC approved) complete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work. |
| 34 | Supply and fixing of C02 type fire extinguisher 4.5 kg. capacity (ISI Marked IS : 2878 & TAC approved) complete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work. |
| 35 | SITC of 05 kw OFF-GRID solar system Solar PV module- 5 kw monoCrystline of Tier-1 Quality, Inverter- 05 Kva, Wire And other Accessories- as required, Lithium battery-200 AH, structure- Pri Galvanize Iron. Complete in all respect. |
| 36 | SITC of 3 HP SOLAR WATER PUMP SYSTEM, SOLAR PV Module-03 Kw mono Crystline of Tier-1 Quality, Controller- 03 hp, Solar Water Pump-03 hp, , panel, mounting structure, Assembly Materials, Tie, Clamps, Tape, Wires etc complete as required at site with Two - Year warranty. |
| 37 | SITC of Solar Street Light 18 watt, SPV module of 36 cell 110 Wp, voltage at maximum power 18.0 v 0.3% , module Voc should be minimum of 22 V. module efficiency should be >14.8%, Life PO4/LFP) 12.8 volt, 45 Ah at sTC, white light emitting diode 18 watt 9LED+Driver), Using LEDs which emits ultraviolet light will not be permitted, (5500-6500 K), 135Lm/W and lumens output of luminaries >2250 lumens, the pole should be hot dip galvanized pipe as per IS 1161 & IS 4736 ie class B with 76 mm outer diameter and minimum 3 mm thickness of 6 mtr. length approx 4.5 mtr. above the ground, mounted at pole below the module mounting structure with 5 year comprehensive warranty |
| 38 | Total Please Enable Macros to View BoQ information |