| 1 | Repairing/Servicing of landing/hydrant valve 63 mm dia. outlet with the replacement of Female Adopter, Plunger, rubber, Washer, rubber gasket, nut bolt etc. Complete as required. |
| 2 | Repairing/Servicing of hose reel drum with changing of 30 mtr. long rubber pipe and shut off nozzle 25mm dia. |
| 3 | Servicing / Minor Repair of Diesel Engine pump, Jockey pump induction motor, Electrical Driven Induction Motor for main pump, non-return valve, butterfly valve, sluice valve, foot valve, Main supply auto/manual electrical driven panel, starter switch, Jockey pump starter, Main pump starter, selectors, Volt Meter, Ampere meter, Battery Charger & relay. Complete along with oiling & greasing, filling of coolant (1ltr.) Complete in all respect. With cost of new battery. |
| 4 | Cleaning and repairing of pump room & underground water tank with water proffing of UG Tank. |
| 5 | Painting of all existing pipe lines, boxes, pump house equipment with the two coat ISI Red Paint and primer etc. |
| 6 | Repairing/Servicing of of 10 Zone Fire Alarm main control panel Microprocessor based with Public Address System. complete in all respect. |
| 7 | Repairing/Servicing of of 6 Zone Local Fire alarm control panel. Complete labour and T&P. |
| 8 | Repairing/Servicing of for Manual Call point Break Glass type housed in MS sheet, including connection. |
| 9 | Repairing/Servicing of Electronic LMT Hooter, housed in MS housing suitable for wall mounting/ceiling, including making connection. |
| 10 | Repairing/Servicing of Responsce indicator pul stanting type suitable for including connection. Complete in all respect. |
| 11 | Repairing/Servicing of Smoke Detector as per specifaction including making connections with wire. |
| 12 | Repairing/Servicing of Heat Detector ROR Type as per specification including making connection with wire. |
| 13 | Refilling of ABC Type 4 Kg Capacity Fire Extinguisher. All complete as per direction of E/ic. |
| 14 | Refilling of Co2 Type 4.5 Kg Capacity Fire Extinguisher. All complete as per direction of Engineer in Charge. |
| 15 | SITC of shut off nozzle complete in all respect. |
| 16 | SITC of RRL Hose PIPE 63 mm dia x 15 m long complete with GM/SS coupling conforming to IS: 636. |
| 17 | SITC of SS Branch Pipe & Nozzle IS: 903. |
| 18 | Supplying & laying of 2x1.5 sqmm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required. |
| 19 | SITC of lionization Smoke Detector as per specifaction. |
| 20 | SITC of Heat Detector ROR Type as per specification |
| 21 | Providing and fixing in position the industrial type pressure gauge complete as required |