| 1 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. |
| 2 | Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) |
| 3 | Nominal concrete 1:4:8 or leaner mix (i/c equivalent design mix) |
| 4 | Dismantling wooden boardings in lining of walls and partitions, excluding supporting members but including stacking within 50metres lead : |
| 5 | Up to 10 mm thick |
| 6 | Dismantling aluminium/ Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable material and stacking of serviceable material with in 50 meters lead as directed by Engineer-in-charge. |
| 7 | Credit for taking away unserviceable glass panels of small size / faded panels / broken pieces etc. |
| 8 | Credit for taking away unserviceable Paticle board panels of small size / damaged / worn out etc. |
| 9 | Credit for taking away unserviceable Aluminium section pieces of small length / damaged etc. |
| 10 | Removing polyvinyl chloride sheet in flooring & skirting including cleaning the flooring, etc all complete as directed by the Engineer- in- charge. |
| 11 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : |
| 12 | 1:2:4 (1 cement : 2 coarse sand(zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 13 | Providing, transporting, hoisting and fixing above plinth level up to floor five level precast reinforced cement concrete in shelves, including setting in cement mortar 1:3 (1 cement : 3 coarse sand), cost of required centering, shuttering and finishing with neat cement punning on exposed surfaces but, excluding the cost of reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand (zone- III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources ). |
| 14 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. |
| 15 | Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 16 | Smooth finishing of the exposed surface of R.C.C. work with 6 mm thick cement mortar 1:3 (1 Cement : 3 fine sand). |
| 17 | Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 5.0 in superstructure above plinth level up to floor V level. |
| 18 | Cement mortar 1:4 (1 cement :4 coarse sand) |
| 19 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. |
| 20 | Fixed to openings /wooden frames with rawl plugs screws etc. |
| 21 | Providing and fixing ISI marked aluminium butt hinges anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour or shade with necessary screws etc. complete: |
| 22 | Note:- Aluminium hinges shall not be used in wooden shutters , Stainless steel hinges shall be preferred |
| 23 | 100x75x4 mm |
| 24 | Providing and fixing aluminium sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete : |
| 25 | 250x16 mm |
| 26 | Providing and fixing aluminium tower bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade with necessary screws etc. complete : |
| 27 | 250x10 mm |
| 28 | 150x10 mm |
| 29 | Providing and fixing aluminium handles ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete : |
| 30 | 100 mm |
| 31 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : |
| 32 | For fixed portion |
| 33 | Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15) |
| 34 | For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately). |
| 35 | Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15) |
| 36 | Providing and fixing 12mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS:12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer-in-charge. |
| 37 | Pre-laminated particle board with decorative lamination on both sides. |
| 38 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): |
| 39 | With float glass panes of 4.0 mm thickness (weight not less than 10 kg/sqm) |
| 40 | With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm) |
| 41 | Providing and fixing Brass 100mm mortice latch and lock with 6 levers without pair of handles (best make of approved quality) for aluminium doors including necessary cutting and making good etc. complete. |
| 42 | Attending repairs to wooden or Aluminium doors or windows by removing and attending repairs including using necessary screws, nails and other accessories required for smooth functioning of door/ window as directed by the Engineer -in - charge. (Hinges, Floor springs, locks will be paid separately) |
| 43 | Refixing aluminium partition, doors, windows and ventilators with dismantled extruded built up standerd tubular section/appropriate Z sections , glass and particle boards fixing with dash fasteners of required dia. & size including necessary filling up of gaps at junctions i.e top, bottom & sides with available material but providing and fixing new screws, gaskets and pivots etc. complete for housing full/Half hight cabins, cubicles and partitions including refixing of recovered floor springs and door closers for doors complete as directed by Engineer-in-charge. |
| 44 | Shifting of dismantled aluminium partition materials of aluminium extruded sections, glass panels, prelaminated particle boards & miscellaneous materials from 2nd floor of T.E. Building, Dispur to 1st floor of T.E. Building, Panbazar, cost including all lift & lead, handling with care to avoid any damage to the materials & transportation etc complete as directed by Engineer-in-charge. |
| 45 | Providing and fixing aluminium deco grill of approved make and pattern, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per drawings and directions of engineer-in-charge. |
| 46 | Deco grill of 5 mm thick, with opening of size 50 x 50 mm and weight should not be less than 1.4 kgs per sqm. |
| 47 | Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. |
| 48 | 40 mm thick with 20 mm nominal size stone aggregate |
| 49 | Providing and fixing homogeneous polyvinyl chloride sheet in flooring & skirting in apporved pattern, colour and shade using rubber based adhesive of approved quality & manufacture like Dunlop S-758, Fevicol SR-998 or equivalent including rolling with light wooden roller weighing about 5 kg, etc all complete as directed by the Engineer- in- charge. |
| 50 | 1.0 mm thick PVC sheet flooring |
| 51 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, |
| 52 | (i)Single socketed pipes. |
| 53 | 75 mm diameter |
| 54 | Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. |
| 55 | Single tee with door |
| 56 | 75x75x75 mm |
| 57 | Bend 87.5° |
| 58 | 75 mm bend |
| 59 | 12 mm cement plaster of mix : |
| 60 | 1:6 (1 cement: 6 fine sand) |
| 61 | 15 mm cement plaster on the rough side of single or half brick wall of mix : |
| 62 | 1:6 (1 cement: 6 fine sand) |
| 63 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer, of required shade and colour all complete : |
| 64 | New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre |
| 65 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC (Volatile Organic Compound ) content less than 50 gram/ litre, of approved brand and of required shade and colour complete to give and even shade. |
| 66 | Old work (one or more coats) |
| 67 | Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour. |
| 68 | Two coats. |
| 69 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : |
| 70 | One or more coats on old work. |
| 71 | Making the opening in brick masonry including dismantling in floor or walls by cutting masonry and making good the damages to walls, flooring and jambs complete, to match existing surface i/c disposal of mulba/rubbish to the nearest municipal dumping ground, all complete as per directions of Engineer-In-Charge. |
| 72 | For door/ window/ clerestory window. |
| 73 | Cleaning Prelaminated partition board panels / glass panels with necessary cleaning acids or Soap chemicals or Glass cleaning solutions as directed by the Engineer-in-charge. |
| 74 | Providing and fixing Vertical Blinds are made up of distinct fabrics pane of good quality material and approved pattern with necessary fixtures and hangers etc. complete all as directed by the Engineer-in-charge. |
| 75 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : |
| 76 | Kitchen sink without drain board |
| 77 | 610x510 mm bowl depth 200 mm. |
| 78 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. |
| 79 | Semi rigid pipe |
| 80 | 40 mm dia |
| 81 | Providing and fixing UV stabilised PVC trap of self cleansing design, 100mm dia inlet and 75mm dia outlet, with PVC grating complete, including cost of cutting and making good the walls and floors: |
| 82 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. :Concealed work, including cutting chases and making good the walls etc. |
| 83 | 20 mm nominal outer dia .Pipes. |
| 84 | Providing and fixing PTMT stop cock of approved quality and colour. |
| 85 | Concealed stop cock, 15 mm nominal bore, 108mm long. Weighing not less than 108 gms. |
| 86 | Providing and fixing PTMT pillar cock of approved quality and colour . |
| 87 | 15mm nominal bore, 125 mm long foam flow. Weighing not less than 120 gms. |