| 1 | Demolilation of cement concrete (unreinforced) in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and directed. |
| 2 | M&L for PCC 1:4:8 type D2 (using 40mm graded stone aggregates) as in fdn filling and mass concrete complete all as specified and directed. |
| 3 | M&L for 100 mm thick PCC 1:4:8 type D2 (using 40mm graded stone aggregates) as in sub base etc complete all as specified and directed . |
| 4 | M&L for 100mm thick PCC 1:2:4 type B1 (using 20mm graded stone aggregates) as in floor finishing even and smooth without using extra cement complete all as specified and directed. |
| 5 | Demolition of brick work built in cement mortar including all quoins, arches, pillar including coping etc. complete all as specified anddirected. |
| 6 | M&L Brick work with sub class \"B\" old size bricks built in CM 1:6, straight or curved on plan exc 6m mean radius on plan complete all as specified and directed. |
| 7 | M&L for 15 mm thick rendering in cement mortar (1:4),on fair faces of brick wall suerfaces, finished even and smooth without using extra cement complete all as specified and directed. |
| 8 | M&L for preparation of newly plastered surface of walland applying three coats of white wash including preparationcomplete all as specified and directed. |
| 9 | M&L for sand filling under floors or in foundations including watering and consolidation complete all as specified and directed. |
| 10 | Dismantling of stone slabs and tiles of any description or thickness as on platform, shelves, floors etc laid, bedded and pointed in any mortar complete all as specified and directed. |
| 11 | M&L for machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60mm thickness, M-35 Grade fixed with grey cement and pigment complete all as specified and directed. |
| 12 | M&L for chequered cement concrete tiles 20cm x 20cm x 25mm thick, set, jointed and pointed in neat cement slurry in floors with grey cement and pigment over 15mm thick screed bed in cement mortor 1:6 complete all as specified and directed. |
| 13 | M&L for enduratiles 30cm x 30cm x 10mm thick, anti resistance of any colour, set, jointed and pointed in neat cement slurry in floors with grey cement and pigment over and including 15mm thick screed bed in cement mortor 1:6 complete all as specified and directed. |
| 14 | M&L for preparartion of bituminus surfaces old/new of road and marking 2.5 mm thick center lines or other lines, stop lines, dashes, arrows etc and the like n.exc 10 cm wide on road pavements with hot applied thermo plastic road marking paint of approved colour conforming to BS 3262-1989 with glass grit @ 300 gms/Sqm over painted surfaces while the painted surfaces are hot with special application machine all as per manufacturers instruction complete all as specified and directed. |
| 15 | S&F in repair two way reflective raod stud minimum dimension of 110 x 128 x 30 mm plastic body reflective pannel of amber red or white colour provided at site as per manufacturer instructions complete all as specified and directed. |
| 16 | Supply and fix in repair solar cat eye aluminum alloy shall be (100% water proofing design according to 65) of size 125mm x 125mm x 25mm (shank 65mm) of high efficiency Mono rystafie solar panel 2.4V/0.3 watt one NI-ed rechargeable battery (1.2V/1600MA) consisting of super bright LED with 10,000 to 18,000 mcd completed as per manufactures instructions etc. all as specified and directed. |
| 17 | S&F in repairs Heavy duty delineator with reflective tap bands made out of Mild steel size 1000 x 100mm, length of the delineator is 1000 mm MS and width 100mm and three nos reflective tape bands, All bands are highly reflective type XI including necessary excavation and earthwork and fixed in PCC (1:2:4) type B1 of size 300 mm x 300mm x300mm complete all as specified & directed. |
| 18 | S&F in repairs ABS body, Polycarbonate lens size 1000mm dia,with accessories & 5 feet long and 3 inch dia MS pole .including necessary excavation and earthwork and fixed in PCC (1:2:4) type B1 of size 300 mm x 300mm x300mm complete all as specified and directed. |
| 19 | S&F in replacement Double Legged informatory Sign Board of Size 1.0Mx1.5M (Appx 1.5 Sqm ) fixed on single frame,both side and meeting back to back on the stainless steel 50x50x3.65mm size Square pipe of 304 grade, the boards are of high intensity grade retro-reflective sheeting of AVERY DENNISON made out of 2mm thick alcoban sheet/aluminium composite pannel sheet confirming IS 736 colour as approved by Engineer-in-charge on stainless steel square pipe of size 50x50x3.65mm square pipe with nuts, washers and bolts, the lettering will be computarised cut of high intensity grade white sheeting (AVERY DENNISON) and mechanicallly fixed on both side board over vertical post of 50mm stainless steel square pipe 3.65 thick 3.20mm thick, 3.20 M long having 2 Nos flat iron 40x5mm strips, 0.30M long on bottom and fixed with and including PCC (1:3:6) type C-1 in post holes of size 0.45x0.45x0.75M complete all as specified and directed. |
| 20 | S&F in repair speed bumps high resistance to severe impacts and hard weather conditions made of sturdy plastic (black/yellow colour) & UV Stabilizers, studded with reflectors on either side complete all as specified and directed. |