| 1 | Excavation in trenches n exc 1.5m wide and n exc 1.50m in depth for foundation etc and getting out in soft/loose or disintegrated soil complete all as specified by Engineer-in-Charge .Note; Most of the Excavation will be done manually andno extra cost will be paid to contractor seperately for manual excavation. If any UG Cables, Pipes are damaged during excavation,entire cost for restoration will be borne by the contractor |
| 2 | All as per item no 1 above but depth exc 1.5 m but not exc 3.00 m complete all as specified by Engineer-in-Charge. |
| 3 | M&L PCC 1 : 3 : 6 type C2 using 40mm graded stone aggregates as in foundation of manholes, drains, posts etc complete all as specified by Engineer-in-Charge |
| 4 | M&L for brick work with sub class \"B\" bricks old size bricks strainght or curved on plan exc 6m mean radius built in CM 1 : 4 including demolition complete all as specified by Engineer-in-Charge |
| 5 | M&L for rendering 15 mm thick on fair faces of brick work or concrete surfaces in CM 1 : 4 finished even and smooth without using extra cementincluding water proofing compound complete all as specified by Engineer-in-Charge Note : Water proofing compound shall be measured separately under appropriate items |
| 6 | Supply only Integral waterproofing compound complete all as specified by Engineer-in-Charge |
| 7 | Demolition and breaking up drain pipes of 150mm dia and more (Salt glazed ware, AC or Reinforced concrete) set in cement mortar |
| 8 | Demolition and breaking up drain pipes of 200mm dia and more (Salt glazed ware, AC or Reinforced concrete) any type set in cement mortar |
| 9 | M&L for concrete(1:3:6) type C2 bed to 150mm dia drain pipes including packing under,and haunching againstthe sides of pipes after they are laid and tested complete all as specified by Engineer-in-Charge |
| 10 | M&L for concrete(1:3:6) type C2 bed to 200mm dia drain pipes including packing under,and haunching againstthe sides of pipes after they are laid and tested complete all as specified by Engineer-in-Charge |
| 11 | S&F DWCPE(SN4) 150mm diameter sewagepipes including snap fit coupler and rubber ring incltesting ,properly jointing and laying in trenches to a levelbedcomplete all as specified by Engineer-in-Charge |
| 12 | S&F DWCPE(SN4) 200mm diameter sewagepipes including snap fit coupler and rubber ring incltesting ,properly jointing and laying in trenches to a levelbedcomplete all as specified by Engineer-in-Charge |
| 13 | Returningfilling in, incl spreading levelling watering and well ramming in layers n exc 25cm (after the pipes have been laid and tested) in soft/loose/disintegrated soil or rocks complete all as specified. |
| 14 | Removing excavated material rocks to a distance exc 1.5 kms but n exc 5 km and depositing where directed . |
| 15 | M&L for providing cement concrete in lintels upto 1.5mtr clear span,cill,stepd,sesmic and other slimlar bands ,plinth course ,string courses,lacing courses ,parapets and raling upto 60cm in height copings kneelers apex stone bed plates, water trufs and like including weathring slighthly rounded or chamfered angles and throting etc type B1, 1 : 2 : 4using 20mm graded aggregate and set in CM 1 : 4 complete all as specified. |
| 16 | Cutting into existing manholes for connecting new drains making good to pipe and rendering,cutting out existing benchingfor and forming branch channel (1/2 or 3/4section ) in cement concrete1 : 2 : 4 type B1 finished smooth and reforming benching as required for 150 mm or 200 mm dia pipes complete all as specified. |
| 17 | S&F Precast plastic fibre reinforced concrete man hole covers\" medium duty \" of overall size 1000 mm x 500 mm x 75 to 80 mm factary made complete all as specified and directed . |
| 18 | Cleaning of EWC\"s, IWC\"s, bottle traps, Nahani traps, gully traps and floor traps etc and CI/ PVC pipes all types top to bottom including junctions etc, cleaning of sewage line upto GT in the area of Old/New APS, Signal enclave and adjoining area (Md accn and all types of Accn) complete all as specified by Engineer-in-Charge |
| 19 | Cleaning of GT\"s in the area of Old/New APS, Signal enclave, Sanjay Vihar and adjoining area as (Md accn and all types of Accn)complete all as specified by Engineer-in-Charge |
| 20 | Cleaning of manhole depth of upto 1.8 m in the area of Old/New APS, Signal enclave, Sanjay Vihar and adjoining area as (Md accn and all types of Accn) and taking out sludge and depositing them to notified area by Municipal corp of delhi for dumping or out side Defence land complete all as specified by Engineer-in-Charge |
| 21 | Cleaning of Manhole depth exc 1.8 min the area of Old/New APS, Signal enclave, Sanjay Vihar and adjoining area as (Md accn and all types of Accn)including removal of all waste etc obtainedduring cleaning of sewage line within 500 m range complete all as specified by Engineer-in-Charge |
| 22 | Cleaning of Sewage line from GT to Ist Manhole in the area of Old/New APS, Signal enclave, Sanjay Vihar and adjoining area as (Md accn and all types of Accn) including removal of all waste etc obtainedduring cleaning of sewage line within 500 m range complete all as specified by Engineer-in-Charge |
| 23 | Cleaning of sewage line n.exc 10 m in lengthiin the area of Old/New APS, Signal enclave, Sanjay Vihar and adjoining area as (Md accn and all types of Accn) including removal of all waste etc obtainedduring cleaning of sewage line within 500 m range complete all as specified by Engineer-in-Charge |
| 24 | Cleaning of Sewage line 0.00mtr to 20.00 m in length in the area of Old/New APS, Signal enclave, Sanjay Vihar and adjoining area as (Md accn and all types of Accn) including removal of all waste etc obtainedduring cleaning of sewage line within 500 m range complete all as specified by Engineer-in-Charge . (Note :- This item will be measured if length exceed from 10.00mtr.) |
| 25 | Cleaning of Sewage lineexc 20.00 mtr but not exc 30.00mtr in lengthin the area of Old/New APS, Signal enclave, Sanjay Vihar and adjoining area as (Md accn and all types of Accn) including removal of all waste etc obtainedduring cleaning of sewage line within 500 m range complete all as directed and as specified. Note :- This item will be measured if length exceed from 20.00mtr.)Note :- For execution of item srl No 18 to 25 above agency should deploy minimum of 04 Nos of Safaiwala and 01 No supervisior on all days of the month/year during the contract period including Sunday and Holidays so as to complaints are attended prompty within 04 hours so that health and life troops and their families may not be adversly affected.The Delay in rectification of complaint more than four hours, the penality will be levied @ Rs.100.00 Per complaint. |
| 26 | Dismantling Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof covering and view cutter complete all as specified and as directed |
| 27 | Dismantling wrought iron or mild steel work of any description not otherwise provided complete all as specified and as directed |
| 28 | Dismantling post or struts ( wood ,steel,RCC) of any description and in any postion including taking out embeed postion in concrete,brick work, Masonary etc and making good the disturbe surfaces all as specified and directed |
| 29 | Dismantling of chain link fencing of any type fixed in any situation including flat iron MS round bars mounted on nuts & bolts etc all as specified and directed |
| 30 | S & F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws including for roof covering and view cutter complete all as specified and as directed. |
| 31 | S & F Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 including two coats of synthetic enamel paint over a coatof red oxide primer on Frame work including prepration of surfsces all as specified and directed |
| 32 | S & F Framed bracketof angles or tees with web and flanges cut to shape, drilled and countersunk for screw, including bending and welding angles, as necessary,gusset plates, riveting, etc.. n exc 10 kg each brackets, conforming to Fe.290.Gde-E-165 (Brackets over 10 kg each to be measured under \"Structural Steel\") including two coats of synthetic enamel paint over a coatof red oxide primer on angle all as specified and directed |
| 33 | S & F in Repair 2mm thick fiber glass reinforced transculent corrugated sheeting with two corrugation side lap fixed with coach screw in roof wall Etc all as specified and directed . |
| 34 | S & F in Repair Galvanised. 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails strain- ing bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. as directed (each line wire to be measured) all as specified and directed |
| 35 | Restraining & recurring including making good stapels etc barbed wire fencing of any description and any postion all as specified and directed |
| 36 | S & F in repair of rust proof concertina coil with and including nessecary GI fixing clips for securing complete all as specified and directed following specification:-(a) dia of coil (unstreched)-610mm , (b) No of sprials per Rm ,(c ) weight of each coil with hessian pack -8050 Kg (+0.5) ,(d) centre coil made from 2.60(+0.50)mm dia GI high tensile wire as per IS 4454 galvanised as pe IS 2629 (e) razor punched stripe :- razor punched strip inCONSEC-ZAL steel comprising of alluminum base with zinc alloy @150 gm/sqm conforming to ASTM A-792/A -792M with addational primer treatment of epoxy/polyerethane & final paint top coat of caulified green shade (BSL) 139 by hot dipping process and barb tape length -23.50mm barb width-18.60mm barbe spacing - 36.00mm center width - 7.40mm |
| 37 | Excavating in post holes (similar holes) each not exceeding 0.50 Cum getting ot, returning filling in ramming earth and broken rubbel mixed with earth around ,in layers not exceeding 25cm in soft/loose soil all as specified and directed |
| 38 | Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provission of binding wire |
| 39 | Supply only Chain link MS galvanisd fencing of mesh any size or type complete all as specified and directed. |
| 40 | Supply only Fe 410-W-250 quality (A) Milds steel in flat,round or square bars , in avilable length |
| 41 | S&F of Mild steel screw bolts (machine made) of 16 to 20mm Dia with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, exc 5cm but n exc 10 long complete all as specified and directed. |
| 42 | Demolition of cement concrete to ground floor(unreinforced) and paving n.exc 15cm thickness (below or above ground level) and removing rubbish of out side MOD land. |
| 43 | Surface excavation n Exc 30cm deep and averaging 15cm deep and getting out in soft loose soil. |
| 44 | M&L 50mm thick PCC (1:4:8)type D 2 (40mm graded stone aggregate)as in sub base, complete all as specified. |
| 45 | M&L Sand filling (sand cushioning) under floors or in foundation incl watering and consolidation all as spd and directed. |
| 46 | M&L Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60mm thickness M-35 grade with grey cement and pigment all as spd and directed |
| 47 | M & Lfor rendering on fair surfaces of Brick work in CM (1:4), 15 mm thick, fair and even, preparation of newly plastered surfaces of walls and applying two coats of cement base paint over a coat of alkali resistent primer on walls complete all as specified by Engineer-in-Charge |
| 48 | M & Lcomplete removal of existing treatment in wall/celling and preparation of old plastered surfaces and applying two coats of cement base paint over a coat of anti alkaline primer complete all as specified by Engineer-in-Charge |
| 49 | S & F in repairs 100 mm dia cast iron (spun pipe) soil, waste and vent pipes in any length with or without ears, with cement joints, fixed in walls/floors/trenches etc complete all as specified by Engineer-in-Charge Note : For pipes fixed on walls to be suitably clamped using stack clamps to maintain 10 to 15 cm distance from the wall (rates inclusive in this item) of appropriate size @ 2 m apart for height of pipe) and all the necessary scaffolding, padding, trestles required for carrying out work should be borne by the contractor in this item only and nothing extra should be paid to contractor for height of building upto G+5 |
| 50 | S & F in repairs 75 mm dia cast iron (spun pipe) soil, waste and vent pipes in any length with or without ears, with cement joints, fixed in walls/floors/trenches etc complete all as specified by Engineer-in-Charge Note : For pipes fixed on walls to be suitably clamped using stack clamps to maintain 10 to 15 cm distance from the wall (rates inclusive in this item) of appropriate size @ 2 m apart for height of pipe) and all the necessary scaffolding, padding, trestles required for carrying out work should be borne by the contractor in this item only and nothing extra should be paid to contractor for height of building upto G+5 |
| 51 | S & F in repairs Cast iron Bends of 100mm dia (any radius), diminishing pieces or tapers (larger bore measured) etc complete all as specified by Engineer-in-Charge Note :- All the necessary scaffolding, padding, trestles required for carrying out work should be borne by the contractor in this item only and nothing extra should be paid to contractor for height of building upto G+5 |
| 52 | S & F in repairs cast iron Bends of 75mm dia (any radius), diminishing pieces or tapers (larger bore measured) etc complete all as specified by Engineer-in-Charge Note :- All the necessary scaffolding, padding, trestles required for carrying out work should be borne by the contractor in this item only and nothing extra should be paid to contractor for height of building upto G+5 |
| 53 | S&F for 110mm bore PVC (SWR) pipes single socketed,inanylength with rubber ring joints, laid in trenches or in floors complete all as specified and directed. |
| 54 | S&F for 75mm bore PVC (SWR) pipes single socketed,inanylength with rubber ring joints, laid in trenches or in floors complete all as specified and directed. |
| 55 | S&F in repair of PVC (SWR) bends any radius of 110mm bore complete all as specified |
| 56 | S&F in repair of PVC (SWR) bends any radius of 75mm bore complete all as specified |
| 57 | Mechanically used high pressure Super Sucker Machine capable of Air lifting of dense sludge like muds, slurry, small stones, debries, grits etc from sewer lines/Manholes thorough vaccum mode and capable of Jetting sewer lines of any dia. The machine shall be used by the contractoras per direction of Engineer-in-Charge as on required basis. Job shall be completed to the entire satisfaction of GE..( For ,Sanjay vihar ,Old / New APS Signal encalveand adjoining area ) Note: Rates quoted cleaned for 08 hrs of super sucker machine. Any work carried out throughout 08 hrs shall be measured as on Job. |