Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | M&L for submain wiringin replacement with 2 runs of copper conductor FRLS PVC insulated unsheathed cable 1100 volt grade 4 sqmm drawn through PVC conduit medium grade ISI marked25mm dia as per IS specification fixed in new concealedin wall/ceiling including conduit and conduit accessories and incl provn of PVC insulated 4 Sqmm FRLS multistranded copper conductor as earth continuity conductor connected to earth dolly all as specified including dismantling old and making good to the disturbed surface by plastering and two coat of distemper all as directed at site Note : (i) Three runs of 4 sqmm cable alongwith conduitand conduit accessories will be measured as one length. (ii)Cutting chasing pinning and making good disturbed surface is included in quoted rates. |
| 2 | All as per BOQ srl item No 1.00 here-in-above but for 2x6 sqmm copper conductor FRLS cable and 1x6 sqmm copper conductor FRLS cable for earth continuity as a earth wire drawn in PVC conduit32 mm dia conduit or higher size heavy duty complete all as specified and directedNote: 03 runs of 06 sqmm cable alongwith PVC conduit of appropriate dia shall be measured as one length cutting chasing pinning and making good disturbed surface is included in quoted rate. |
| 3 | All as per BOQ srl item No 1.00 here-in- above but for 4x6 sqmm copper conductor FRLS cable and 2x6 sqmm copper conductor FRLS cable for earth continuity as a earth wire drawn in PVC conduit32 mm dia conduit or higher size heavy duty complete all as specified.Note: 06 runs of 10 sqmm cable alongwith PVC conduit of appropriate dia shall be measured as one length cutting chasing pinning and making good disturbed surface is included in quoted rate. |
| 4 | All as per BOQ srl item No 1.00 here-in-above but for 4x10 sqmm copper conductor FRLS cable and 2x10 sqmm copper conductor FRLS cable for earth continuity as a earth wire drawn PVC conduit32 mm dia conduit or higher size heavy duty complete all as specified.Note: 06 runs of 10 sqmm cable alongwith PVC conduit of appropriate dia shall be measured as one length cutting chasing pinning and making good disturbed surface is included in quoted rate. |
| 5 | S&F in replacement LED tube light fitting1x18 watt, 230 volts in commercial channel with powder coated CRCA sheet housing with opal diffuser for LED with LED tube rod with high efficient LED in aluminium housing with clear & milky diffuser connecting with twin core twisted flexible copper conductor cable of suitable length of suitable size complete with all accessories all as specified.Note :The LED rod should Have PF >0.9 ,input voltage 90-300V, IP-20 , LM 80 strandedluminaries efficiency 100 lumen/watt |
| 6 | Taking down/out old unserviceable FTL tube rod of any wattage and Supply and fixing in repair LED tube rod1x18 watt, 230 volts complete with all accessories all as specified.Note :The LED rod should Have PF >0.9 ,input voltage 90-300V, IP-20 , LM 80 strandedluminaries efficiency 100 lumen/watt |
| 7 | S&F in replacementrecess/Surface mounting LED flat panel 2\"x2\" with high efficient LED & glare free full window opal diffuser of 36 watt incl connecting with twin core twisted flexible copper conductor cable complete with all accessories all as specified. Note :The LED rod should Have PF >0.9 ,input voltage 90-300V, IP-20 , LM 80 strandedluminaries efficiency 100 lumen/watt |
| 8 | S&F in replacement indoor decorative LED batten with opal diffuser with inbuilt LED tube 10W and driver designed with high transmitting optics for even light distribution IP 20 degree protection having length 620mm and PF 0.9, CRI> 70, L 70 and connecting with twin core twisted flexible copper conductor cable complete all as specified and as directed |
| 9 | S&F in replacment LED lamp 7 wattcomplete all as specified and as directed |
| 10 | Taking down carefully aluminum/copper point wiring (light, fan, socket or power) complete fittings such as switches, C/roses, Pendants DBs, sockets etc. including taking down carefully by unscrewing from boards/outlet/DBs/fittings such as switches, sockets, lamp holders, brackets, ceiling fittings bulkhead fittings, sketch fittings, tube light fittings, fan regulator, electric meters, meter box any type etc as directed by Engineer-in-Charge. and making good to the disturbed surface by plastering and two coat of distamper. complete all as specified and as directed |
| 11 | M&L for concealed point wiring complete with 1.5 Sqmm single core multistranded copper conductor FRLS PVC insulated and unsheathedcable 1100 volts grade drawn through and including non metallic rigid PVC conduit,medium grade minimum 20mm dia ISI marked and conduit accessories fixed concealed in wall/ceiling/roof etc with sunken type pressed steel/welded MS terminal boxes made out of 1.6 mm MS sheet, 3mm thick laminated sheath top cover for mounting of fittings,switches,sockets outlets,regulators etc complete including provisining of 1.5 sqmm FRLS PVC insulatedunsheathedcable 1100 volt grade with multi stranded copper conductor to common earth and connected to earth dolly for the following :- |
| 12 | One light/fan/ controlled by one switch 6 amp one way complete all as specified and directed. |
| 13 | One 3 pin switch socket combination 6 amp on the independent board complete all as specified and directed. |
| 14 | One 3 pin switch socket combination on same board with other switches complete all as specified and directed. |
| 15 | One bell point controlled by one bell push complete all as specified and directed. |
| 16 | All as per BOQ srl item No. 11.00 here-in-above but point wiring with 2.5 sqmm single core multi stranded copper conductor FRLS PVC insulated & unsheathedcable 1100 volt grade and 2.5 sqmm FRLS PVC insulated and unsheathed cable 1100 volt grade with multi stranded copper conductor for earth wire for 15/16 amp multi purpose socket combination point on independent board. complete all as specified and as directed |
| 17 | M&L forpoint wiring on wall/ surface in PVC casing caping of size 20mm complete with 1.5 Sqmm single core multistranded copper conductor FRLS PVC insulated and unsheathedcable 1100 volts grade drawn through including PVC casing caping and provisining of 1.5 sqmm FRLS PVC insulatedunsheathedcable 1100 volt grade with multi stranded copper conductor to common earth and connected to earth dolly with sunken type pressed steel/welded MS terminal boxes made out of 1.6 mm MS sheet, 3mm thick laminated sheet top cover for mounting of fittings,switches,sockets outlets,regulators etc complete all as specified and directed. |
| 18 | One light/fan/ controlled by one switch 6 amp one way complete all as specified and directed. |
| 19 | One 3 pin switch socket combination 6 amp on the independent board complete all as specified and directed. |
| 20 | One 3 pin switch socket combination on same board with other switches complete all as specified and directed. |
| 21 | One bell point controlled by one bell push complete all as specified and directed. |
| 22 | All as per BOQ srl item No. 17.00 her-in-above but point wiring with 2.5 sqmm single core multi stranded copper conductor FRLS PVC insulated & unsheathedcable 1100 volt grade and 2.5 sqmm FRLS PVC insulated and unsheathed cable 1100 volt grade with multi stranded copper conductor for earth wire for 15/16 amp multi purpose socket combination point on independent board. complete all as specified and as directed |
| 23 | M & L forpoint wiring on wall/ surface in steel conduit of size 20 mm complete with 1.5 Sqmm single core multistranded copper conductor FRLS PVC insulated and unsheathedcable 1100 volts grade drawn through and including steel conduit with all accessories including provisining of 1.5 sqmm FRLS PVC insulatedunsheathedcable 1100 volt grade with multi stranded copper conductor to common earth and connected to earth dolly with sunken type pressed steel/welded MS terminal boxes made out of 1.6 mm MS sheet, 3mm thick laminated sheet top cover for mounting of fittings,switches,sockets outlets,regulators etc complete all as specified and directed. |
| 24 | One light/fan/ controlled by one switch 6 amp one way complete all as specified and directed. |
| 25 | One 3 pin switch socket combination 6 amp on the independent board complete all as specified and directed. |
| 26 | One 3 pin switch socket combination on same board with other switches complete all as specified and directed. |
| 27 | All as per BOQ srl Item No. 23.00 here-in-above but point wiring with 2.5 sqmm single core multi stranded copper conductor FRLS PVC insulated & unsheathedcable 1100 volt grade and 2.5 sqmm FRLS PVC insulated and unsheathed cable 1100 volt grade with multi stranded copper conductor for earth wire for 15/16 amp multi purpose socket combination point on independent board complete all as specified and as directed.Note:For item 11.00, 17.00 and 23.00 :- The rate of chase cutting and making good the surface will be deemed in the rates quoted by the contractor. |
| 28 | S&F in repair switch piano modular type 6 amp single pole flush type one way complete all as specified and as directed. |
| 29 | S&F in repair switch piano modular type 16 amp single pole flush type one way complete all as specified and as directed. |
| 30 | S&F in repair socket outlet modular type 3 pin 6 amp flush type complete all as specified and as directed. |
| 31 | S&F in repair socket outlet modular type 3 pin 16 amp flush type complete all as specified and as directed. |
| 32 | S&F in repair modular step type fan regulator electronic type 120 watt 2 module complete all as specified and as directed. |
| 33 | S&F in repair modular cover plate with frame for 3 module complete all as specified and as directed. |
| 34 | S&F in repair modular cover plate with frame for 4 module complete all as specified and as directed. |
| 35 | S&F in repair modular cover plate with frame for 6 module complete all as specified and as directed. |
| 36 | S&F in repair modular cover plate with frame for 8 module all as specified. |
| 37 | S&F in repair modular metal flush box 3 module complete all as specified and as directed. |
| 38 | S&F in repair modular metal flush box 4 module complete all as specified and as directed. |
| 39 | S&F in repair modular metal flush box 6 module complete all as specified and as directed. |
| 40 | S&F in repair modular metal flush box 8 module complete all as specified and as directed. |
| 41 | S&F in repair switch piano flush type single pole, one way 6amp complete all as specified and directed |
| 42 | S&F in repair switch piano flush type single pole, one way 15 amp complete all as specified and directed. |
| 43 | S&F in repairsocket outlet 2 in 1 , 3 pin 5 A flush type complete all as specified and directed. |
| 44 | S&F in repairsocket outlet 2 in 1 , 3 pin 5 A and 15 Aflush type complete all as specified and directed. |
| 45 | S&F in repair ceiling rose 65x50mm three terminals 230 volt complete all as specified and directed. |
| 46 | S&F in repair lamp holder,PVC/Polycarbonate type and back plate suitable for batten fitting complete all as specified. |
| 47 | S&F in repair bell push flush type 230 Volt complete all as specified and as directed. |
| 48 | S&F in repair call bell ding dong 230 V single phase complete all as specified and as directed. |
| 49 | S&F in repair step type fan regulator electronic type in 5 step, 100 watt capacity switch/socket type complete all as specified and as directed. |
| 50 | S&F in replacement sheet metal enclosures for MCB distribution board 415 Volts three pole and neutral 4 way double door type flushed inside the wall with 200 Amp rated bus barincl making the surface good complete all as specified and as directed. |
| 51 | S&F in replacement sheet metal enclosures for MCB distribution board 230 Volts single pole and neutral 2 way single door type flushed inside the wall with 200 Amp rated bus bar incl making the surface good complete all as specified and directed. |
| 52 | S&Fin replacement sheet metal enclosures for MCB distribution board 230 Volts single pole and neutral 4 way double door type flushed inside the wall with 200 Amp rated bus bar incl making the surface good complete all as specified and directed. |
| 53 | S&F in replacement sheet metal enclosures for MCB distribution board 230 Volts single pole and neutral 8 way double door type flushed inside the wall with 200 Amp rated bus bar incl making the surface good complete all as specified and directed. |
| 54 | S&F in replacement MCBs5 to 32 amp SP C curve 240 Volts 10 KA finger proof terminal, bi-connect termination, label holder, 35 mm² terminal capacity, insulated sliding shutter, large two position dolly, ISI markedto be fixed on DB .complete all as specified and as directed. |
| 55 | S&F in replacement MCBs 32 amp SPN C curve 240 Volts 10 KA finger proof terminal, bi-connect termination, label holder, 35 mm² terminal capacity, insulated sliding shutter, large two position dolly, ISI markedto be fixed on DB .complete all as specified and as directed. |
| 56 | S&F in replacement MCBs16 to 32 amp TPN C curve 240 Volts 10 KA finger proof terminal, bi-connect termination, label holder, 35 mm² terminal capacity, insulated sliding shutter, large two position dolly, ISI markedto be fixed on DB . complete all as specified and as directed. |
| 57 | S&F in replacement MCBs40 to 100 amp TPN C curve 240 Volts 10 KA finger proof terminal, bi-connect termination, label holder, 35 mm² terminal capacity, insulated sliding shutter, large two position dolly, ISI markedto be fixed on DB . complete all as specified and as directed. |
| 58 | S&F in replacement MCCB four pole 415 Volts, 63 A, 16 KA complete all as specified and as directed. |
| 59 | S&F in replacement MCCB four pole 415 Volts, 100 A, 16 KA complete all as specified and as directed. |
| 60 | S&F ceiling fans complete with blades, down rods,without remote with electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) including taking down old ceiling fans complete all as specified and as directed. |
| 61 | M&L for earthing complete with galvanized steel earth plate electrode 600x600x6.0 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below normal ground level,the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15cm on all side and including connected toand includinggalvanized earth lead wire 4.0 mm dia upto 7.5 mtrs long by means ofnuts and bolts, check nuts and washers of GI and connected to earhing test point and earth dollyall as shown in electrical plate No 3 of MES SSR part I and testing on completion includingnecessary excavation and earth work in any type of soil,PCC(1:3:6) type C1 chamber,pre-cast RCC slab 50mm thic in cement concrete (1:2:4),type B1,reinforced with welded steel wire fabric or XPM,(weight not less than 4 Kg per Sqm) with cast iron frame,funnel with watering pipe 20mm dia medium grade,wire mesh and lugs,GI protection pipe,15mm dia,light grade,7.5 mtr long for protection of earth lead upto test point etc all as specified and as directed. Note : The Earth result should be less than 3 ohmand the result will be checked in presenceMES Rep. if desired earth resistance is not found then entire earthing shall be re-done by Contractor without accruing any extra cost to the Govt. |
| 62 | S&F in replacementplug top & socket with sheet metal enclosures Single pole including one MCB 20 Amp, 240 Volts,10 KA complete all as specified and as directed. |
| 63 | S&F exhaust fan, PVC body AC single Phase. 230V of size 250m sweep with, blades, and frame and louvers complete all as specified and as directed including taking down old exhaust fan. |
| 64 | M&L for earthing complete with copper earth plate electrode 600mmx600mmx3.15 mm thick buried directly in ground earth pit not less than 3 mtr below ground level with top edge of earth plate not less than 2.25 mtrs below found level connected to copper earth strip of20x3 mm by two means of nuts, bolts, thimbles, chuck nuts, washers test points including one end firmly fixed with earth plate by means of nut and bolts and other end of copper strip to test point GI watering pipe, 20mm dia duly plugged shall be projected out at least 20 cms above the ground level incl covering the earth electrode with charcoal dust salt all around not less than 15cm provision of earth pit RCC cover all as shown in electrical plate No. 5 of SSR Part I, 1991 etc incl necessary earth an disposal of surplus soil complete and testing all as specified and directed. Note : The Earth result should be less than 3 ohmand the result will be checked in presenceMES Rep if desired earth resistance is not found then entire earthing shall be re-done by Contractor without accruing any extra cost to the Govt. |
| 65 | S&F in replacment Switch flame Proof rotary type with termination box in LM-6 16 A single Pole 240 V complete all as specified and directed. |
| 66 | S&F in replacment LED light fitting 2x16 Watt flame proof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum hosing with heat resistant toughened glass with LED tube light fixtures driver, holders, connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size complete all as specified and directed. |
| 67 | S&F in replacement industrial plug and socket 32 A 5 pin 8 module having protection IP 54, incl MCBs 4 pole duly fixed in wall all as specified. |
| 68 | S&F in replacement industrial plug and socket 63 A 5 pin 8 module having protection IP 54, incl MCBs 4 pole duly fixed in wall all as specified. |
| 69 | S & F in replacement MCCB 125 Amp, 3 pole 16 KA with adjustable thermal release fixed magnetic protection complete all as specified and as directed. |
| 70 | S & F in replacement MCCB 160 Amp, 4 pole 36 KA with adjustable thermal release fixed magnetic protection complete all as specified and as directed. |
| 71 | S & F in replacement MCCB 200 Amp, 4 pole 36 KA with adjustable thermal release fixed magnetic protection complete all as specified and as directed. |
| 72 | S & F in replacement MCCB 250 Amp, 4 pole 36 KA with adjustable thermal release fixed magnetic protection complete all as specified and as directed. |
| 73 | S & F in replacement MCCB 400 Amp, 4 pole 36 KA with adjustable thermal release fixed magnetic protection complete all as specified and as directed. |
| 74 | S & F in replacement MCCB 630 Amp, 4 pole 50 KA with adjustable thermal release fixed magnetic protection complete all as specified and as directed. |
| 75 | S&F in replacement off load change over switch 415 Volt 630 Amp 4 Pole in sheet metal enlosure side handle operated complete all as specified and as directed. |
| 76 | S&F in replacement off load change over switch 415 Volt 400 Amp 4 Pole in sheet metal enlosure side handle operated complete all as specified and as directed. |
| 77 | S&F in replacement Bus Bar Chamber of size 60 x 60 x45 cm suitable of 3 phase 433 Volts outdoor type made out of 3.15 mm thick M S Sheet with 200 Amps rated aluminium busbar (4 Nos ) PVC sleeves and coloured (Red,Yellow,Blue and Black) with locking arrangments and angle iron stand of size 40 x 40 x 6mm frame grouted in ground with PCC foundatiuon 1:2:4 type C1 with 20mm graded stone aggregate alongwith all necesary cable connections,lugs and cable gland including 2 coat of paint over a coat of red oxide primercomplete all as specified and as directed. |
| 78 | All as per BOQ srl item No.77.00 here-in-above but with 400 Amps rated aluminium busbar complete all as specified and as directed. |
| 79 | Supply, laying, jointing and testing in trenches, passing through ducts/pipes, fixing along poles, jointing and testing ; XLPE cable insulated, screened, PVC bedded, galvanized steel wire or strip armoured electric power cable (heavy duty) with aluminium stranded conductor 1100 volts grade of size 3.5 core 300 Sq mmincluding taking down old unserviceable cable complete all as specified and directed . |
| 80 | Supply, laying, jointing and testing in trenches, passing through ducts/pipes, fixing along poles, jointing and testing ; XLPE cable insulated, screened, PVC bedded, galvanized steel wire or strip armoured electric power cable (heavy duty) with aluminium stranded conductor 1100 volts grade of size 3.5 core 240 Sq mmincluding taking down old unserviceable cable complete all as specified and directed . |
| 81 | Supply, laying, jointing and testing in trenches, passing through ducts/pipes, fixing along poles, jointing and testing ; XLPE cable insulated, screened, PVC bedded, galvanized steel wire or strip armoured electric power cable (heavy duty) with aluminium stranded conductor 1100 volts grade of size 3.5 core 185 Sq mmincluding taking down old unserviceable cable complete all as specified and directed . |
| 82 | Supply, laying, jointing and testing in replacement in trenches, passing through ducts/pipes, fixing along poles, jointing and testing ; XLPE cable insulated, screened, PVC bedded, galvanized steel wire or strip armoured electric power cable (heavy duty) with aluminium stranded conductor 1100 volts grade of size 3.5 core 150 Sq mmincluding taking down old unserviceable cable complete all as specified and directed . |
| 83 | Supply, laying, jointing and testing in trenches, passing through ducts/pipes, fixing along poles, jointing and testing ; XLPE cable insulated, screened, PVC bedded, galvanized steel wire or strip armoured electric power cable (heavy duty) with aluminium stranded conductor 1100 volts grade of size 3.5 core 120 Sq mmincluding taking down old unserviceable cable complete all as specified and directed . |
| 84 | Supply, laying, jointing and testing in trenches, passing through ducts/pipes, fixing along poles, jointing and testing ; XLPE cable insulated, screened, PVC bedded, galvanized steel wire or strip armoured electric power cable (heavy duty) with aluminium stranded conductor 1100 volts grade of size 3.5 core 95 Sq mmincluding taking down old unserviceable cable complete all as specified and directed . |
| 85 | Supply, laying, jointing and testing in trenches, passing through ducts/pipes, fixing along poles, jointing and testing ; XLPE cable insulated, screened, PVC bedded, galvanized steel wire or strip armoured electric power cable (heavy duty) with aluminium stranded conductor 1100 volts grade of size 3.5 core 70 Sq mmincluding taking down old unserviceable cable complete all as specified and directed . |
| 86 | Supply, laying, jointing and testingin trenches, passing through ducts/pipes, fixing along poles, jointing and testing ; XLPE cable insulated, screened, PVC bedded, galvanized steel wire or strip armoured electric power cable (heavy duty) with aluminium stranded conductor 1100 volts grade of size 3.5 core 50 Sq mmincluding taking down old unserviceable cable complete all as specified and directed . |
| 87 | Supply, laying, jointing and testing in trenches, passing through ducts/pipes, fixing along poles, jointing and testing ; XLPE cable insulated, screened, PVC bedded, galvanized steel wire or strip armoured electric power cable (heavy duty) with aluminium stranded conductor 1100 volts grade of size 3.5 core 35 Sq mmincluding taking down old unserviceable cable complete all as specified and directed . |
| 88 | Supply, laying, jointing and testing in trenches, passing through ducts/pipes, fixing along poles, jointing and testing ; XLPE cable insulated, screened, PVC bedded, galvanized steel wire or strip armoured electric power cable (heavy duty) with aluminium stranded conductor 1100 volts grade of size 3.5 core 25 Sq mmincluding taking down old unserviceable cable complete all as specified and directed . |
| 89 | Supply, laying, jointing and testing in trenches, passing through ducts/pipes, fixing along poles, jointing and testing ; XLPE cable insulated, screened, PVC bedded, galvanized steel wire or strip armoured electric power cable (heavy duty) with aluminium stranded conductor 1100 volts grade of size 4 core 16 Sq mmincluding taking down old unserviceable cable complete all as specified and directed . |
| 90 | Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m depth forlaying of cables etc and getting out in soft loose soil complete all as specified and as directed. |
| 91 | All as per Item No. 90.00 here-in-above but for depth exceeding 1.50 m and not exceeding 3.00 m complete all as specified and directed.. |
| 92 | Returning filling in including spreading leveling watering and well ramming in layers not exceeding 25cm in soil complete all as specified and as directed. |
| 93 | Removing excavated material not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point as in soil complete all as specified and as directed. |
| 94 | M&L filling approved river sand in trenches for sand cushioning of laying of cables to the full width of excavated trench 08 cm thick before laying the cable and 15 cm above the cable, gently punned down, stretching and testing of cable on transformer yard etc complete all as specified and directed.Note :- Thickness of sand cushioning after punning down i.e 18cm shall be measured for payment purpose only |
| 95 | M&L for brick protection cover of UG cable by old size bricks common burnt clay building bricks sub class `B’ laid dry and flat abutting each other with width equal to length of brick and gap between adjacent brick not exceeding 10mm complete all as specified and as directed. |
| 96 | S&F in replacement GI tubing 80 mm bore light grade galvanised with all fitting complete for cable protection under road crossing/on pole/wall or similar position complete all as specified and as directed. |
| 97 | All as per BOQ srl item No 96.0 here-in- above but of size 50mm dia bore complete all as specified and as directed. |
| 98 | All as per BOQ srl item No.96.00 here-in-above but of size 40mm dia bore complete all as specified and as directed. |
| 99 | M&L for Making bore to road/cement path/hard standing for providing GI pipe 40/50/80mmboth end socketed for passing armoured cable incl making good the disturbed surface complete all as specified and as directed. |
| 100 | M&L for locating the fault in LT cable of any size by any method as per the direction of Eng-in-charge and repair the same by providing straight through or end joints . Note: The joint and earth work will be measured and paid separately. |
| 101 | Disconnecting the existing cable from panel/pole, preparing the end for jointing including all earth work and S & F end joint kit in replacement for 1.1 KV grade suitable for outdoor/indoor type terminal heat shrinkable type joints with jointing material for 3.5 core XLPE armoured aluminium conductor cable of size 185 to 300 Sqmm complete all as specified and as directed. |
| 102 | All as per BOQ srl item No.101.00 here-in-above but of size 70 to 150Sqmm complete all as specified and as directed. |
| 103 | All as per BOQ srl item No.101.00 here-in-above but of size 25 to 50Sqmm complete all as specified and as directed. |
| 104 | Disconnecting the existing cable from panel/pole, preparing the end for jointing including all earth work and S & Fjoint kit in replacement kit for 1.1 KV grade suitable for straight through heat shrinkable type joints with jointing material for 3.5 core XLPE armoured aluminium conductor cable of size 185 to 300 Sq mm complete all as specified and as directed. |
| 105 | All as per BOQ srl item No.104.00 here-in- above but of size 70 to 150Sqmm complete all as specified and as directed. |
| 106 | All as per BOQ srl item No.104.00 here-in- above but of size 25 to 50Sqmm complete all as specified and as directed. |
| 107 | M&L for painting the swaged steel tubular LT poles including cross arms,clamps and light brackets surface of any discription after preparation of old painted surface(removing old paint by paint removers and cleaning with scraper any number of existing coats) with one finishing coat aluminium paint and marking pole no. as per existing numbers and painting of lower portion of pole in alternate layer of black and yellow shades/colour complete all as specified and as directed. |
| 108 | M&L for preparation of old PCC surfaces and applying alternatively in sky blue and orangecolour one coat of synthetic enamel black paint to PCC pole upto 1 mtrheight from ground levelincluding numbering of pole with black paintcomplete all as specified and as directed. |
| 109 | Repair/Maintenance of any type any size LT/HT panel by opening all incoming and outgoing LT/HT cable connection and reconnecting the LT/HT cable in proper manner by changing all burnt lugs and proper insulation of all nacked cable incl cleaning of panel with blower from inside and removing all grass and bushes around the panel up to 2 mtr distance incl Painting of panel one coat of synthetic enamel paint of grey colour, welding work for repair of broken hinges, doors, all as specified. |
| 110 | S&F traffic signal light, 240V, 50 Hz AC with two colour (Green & Red) indicator warning light, Stop and Go light, PC housing waterproof, IP65 including all necessary fixing arrangements and wiring connections including taking down old traffic signal light complete all as specified and directed. |
| 111 | Taking down the existing Steel tubular poles from the premises of air force station ambala from one location and fixing the same to the another position within the premises air force station ambala with mild steel base plate of size 30cmx30cmx6mm thick, welded at bottom and cap finial taper plugs, bolt, nuts and screw as specified and fixed in true vertical position .Note :- (a) Excavation earth work, foundation concrete shall be measured and paid separately under respective items.(b) Poles shall be painted with two coats of black bituminous paint throughout internally and externally up to planting depth.The remaining portion of the exterior surface shall be painted with two coats of aluminium paint over a coat of red oxide primer. |
| 112 | S&F energy efficient LED flood light fitting, 250W, input voltage 230VAC, 50Hz with ingress protection IP 65, CRI >70, PF>0.9, minimum 25000 burning hours,LM-80, lumen efficacy ≥100 lumen/watt, THD> 20, Aluminium housingincluding all fixing arrengment like clamps, nuts, bolts, washers, 120W LED lamp with all accessories pre-wired and connecting with twin core twisted flexible copper conductor cable with all necessary staging, etc. for fixing at any locations including taking down the old unserviceable fittings complete all as specified and as directed. |
| 113 | All as per BOQ srl item No.112.00 here-in-above but 120W complete all as specified and as directed. |
| 114 | All as per BOQ srl item No.112.00 here-in-above but 70W complete all as specified and as directed. |
| 115 | S&F energy efficient LED street light fitting, 120W, input voltage 230VAC, 50Hz with ingress protection IP 65, CRI >70, PF>0.9, minimum 25000 burning hours,LM-80, lumen efficacy ≥100 lumen/watt, THD> 20, Aluminium housingincluding all fixing arrengment like clamps, nuts, bolts, washers, 120W LED lamp with all accessories pre-wired and connecting with twin core twisted flexible copper conductor cable with all necessary staging, etc. for fixing at any locations including taking down the old unserviceable fittings complete all as specified and as directed. |
| 116 | All as per BOQ srl item No.115.00 here-in-above but 90W complete all as specified and as directed. |
| 117 | All as per BOQ srl item No.115.00 here-in-above but 70W complete all as specified and as directed. |
| 118 | All as per BOQ srl item No.115.00 here-in-above but 35W complete all as specified and as directed. |
| 119 | S&F in replacement PVC insulated copper conductor cable, 3 core 1.5sqmm, served with inner sheathing of PVC tape and overall PVC sheathed, 1100V grade heavy duty in connections complete all as specified and as directed. |
| 120 | S&F in replacement street light GI pipe bracket 40mm dia 1.50m length (ISI marked) light grade bend to shape with two Nos MS clamp duly painted nuts and bolts etc , complete all as specified and as directed. |
| 121 | M&L for cement concrete 1:3:6 type C-2 using (40 mm graded mechanically crushed stone aggregate) in foundation filling of poles/stays/plinths etc complete all as specified and directed by Engineer-in-Charge. |
| 122 | M&L for cement concrete 1:2:4 type B-1 using (20 mm graded mechanically crushed stone aggregate) in coping of poles including form work whereas required as per site requirement complete all as specified and directed by Engineer-in-Charge. |
| 123 | Supply & spreading 40 mm graded mechanically crushed stone aggregate in layer not exceeding 150mm thick each layer around the transformer at sub station complete all as specified and directed. |
| 124 | Supply & spreading 20 mm graded crushed stone aggregate in layer not exceeding 150mm thick each layer around the transformer at sub station complete all as specified and directed. |
| 125 | M&L for Aluminium strip 25x3mm on FRP insulator fixed on wall/MS sheet or floors incl connecting to lightening arrester/earthing/test point strip should be brazed/welded at each jointcomplete all as specified and as directed. |
| 126 | S&F copper strip of size 20x3 mm complete with saddles and base insulators (made out of porcelene/PVC) and fixing screws on roof and down side conductors complete all as specified and as directed. |
| 127 | S&F PVC/Porcelain insulator on wall/MS sheet incl removing of existing earth strip of any type and refixing the same on insulators. complete all as specified and as directed. |
| 128 | M&L for Air termination, single pointed aluminium rod 12 mm dia and 300 mm long incl fixing base plate with insulator complete fixing on the top roof of the hanger complete all as specified and directed. |
| 129 | S&F wall mounted fan of 450mm sweep with, air delivery 110 CMM, 1325 RPM,230 V Single Phase AC with up and down tiltmachanism inclulding clamp, nuts bolts and washerfor fixing in the wall including taking down old fan and making good the distrubed surface complete all as specified and as directed |
| 130 | M&L for overhauling and rewinding of electricgate motor of cap 3 HP, 415 Voltsby removing worn out winding, cleaning of slots and insertion of insulating paper in the slots in appropriate size and rewinding with super enamelled copper wire of suitable size along with insertion of superior quality of insulating material, winding, varnishing and drying, including dismantling of electric motor connection and re-fixing back after rewinding including replacement of connection plate and making necessary electric connection and testing complete all as specification and directed. Note :- (i) The Job includesreplacement of unsv parts such as starter, Contactor, MCB/MCCB, relay, limit switch, NO/NC switch, forward/reverse switch,emergency stop switch, and rewiringusing copper conductor orany other parts which required for smooth functionig of gate motor. (ii) The alignment of thegate and servicing & greasing of connnected items such as pullley, rail, wheels, chain etc complete is also incuded in quoted rate. |
| 131 | M&L for servicing / overhauling of gear box of motorised gate including replacement of old unsv / broken gears, oiling/greasing, filling gear oil, and replacement of gaskets nuts bolts washer etc complete, including dismantling of gear box connection and re-fixing back after repairing and making necessaryconnection with motor and testing complete all as specification and directed.Note :- (i) The job included complete servicing and replacement of connected spare items/parts to make the gear box functional for motor installed with the gate. |
| 132 | Supply Installation Testing and Commissioning of a set of maintenance free tripod earthing system consisting of 3 No. of Copper Bonded Earth Rodof 10 feetlength, 17.2 mm dia made of high tensile low carbon steel circular rods, molecularly bonded with 99.9% electrolytic grade copper on outer surface (minimum copper bonding thickness-250 microns) with exothermically jointed copper bus bar of 150x50x6mm for long lasting and connection . Each copper bonded rod and the exothermically jointed busbar both should be CPRI tested on at least 25KA Fault current to ensuring the high current carrying capacity of the system and earth rod should be certified by Underwriter laboratories confirming to comply with UL467 international standard for grounding and bonding equipment. Each rod should be used with minimum 50kg earth enhancing compound that should be ROHS tested and have passed , Resisitivity of the earth enhancing compond should be less than 0.05 ohm meter- an international standard for Earth Enhancement Compound by NABL accredit Lab.Note : The rate forinterconnection of tripod earthwith Copper strip ofsize 20x3 mm andpoly carbonate earth pit cover -03 Nos shall deemed to be included in the quoted rates. The Earth result should be less than 1 ohm and the result will be checkedin presence of user rep & MES Rep. |
| 133 | M&L for earthing complete with galvanized steel earth plate electrode 600 x 600 x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below normal ground level,the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15cm on all side and including connected toand includinggalvanized earth lead strip 32 x 6 mm size upto 7.5 mtrs long by means ofnuts and bolts, check nuts and washers of GI and connected to earhing test point and earth dollyall as shown in electrical plate No 3 of MES SSR part I and testing on completion includingnecessary excavation and earth work in any type of soil,PCC(1:3:6)type C1 chamber,pre-cast RCC slab 50mm thick in cement concrete (1:2:4),type B1,reinforced with welded steel wire fabric or XPM,(weight not less than 4 Kg per Sqm) with cast iron frame,funnel with watering pipe 20mm dia medium grade,wire mesh and lugs,GI protection pipe,40mm dia,light grade,7.5 mtr long for protection of earth lead upto test point etc alongwith old unserviceable earthing all as specified and as directed. Note : if desired earth resistance is not found, than entire earthing shall be re-done by Contractor without accruing any extra cost to the Govt. |
| 134 | S&F in replacement junction box thermoplastic polycarbonate enclosure, shock proof, IP65/IP66 (weather, rust, dust, water and vibration proof, outdoor type, internally embedded gasket with provision for all side cable entry through glands of size 250x200x100mm with 4Nos. aluminium bus bar of size 25x6mm, 8Nos. terminals with andincluding 01No. 10Amp MCB 10kA duly mounted fixed with MS clamps fabricated out of FI 40x3mm of required shape and size and fied at any location complete all as specified and as directed |
| 135 | S&F in replacement automatic street light switch using nature switch for automatic switching of street lights, 8kW equally distributed over 3 phase based on LUX level of natural light, infrared sensor based on nature switch along with contactor 60A/phase, MCB SP for input and output 63A, wiring for main load with 3 core 16sqmm copper cable duly fixed to pole/wall, mounted on enclosure made out of rust proof, electric shock proof, termite proof and FR grade SMC junction box of protection class IP 54 fixed at any location complete all as specified and as directed |
| 136 | S&F in replacement flame proof weather proof energy efficient LEDlight fitting, 150W, input voltage 230VAC, 50Hz with ingress protection IP 65, CRI >70, PF>0.9, minimum 25000 burning hours,LM-79, lumen efficacy ≥100 lumen/watt, THD> 20, CRCA housingincluding all fixing arrengment like clamps, nuts, bolts, washers with all accessories pre-wired and connecting with twin core twisted flexible copper conductor cable with all necessary staging, etc. for fixing at any locations including taking down the old unserviceable fittings complete all as specified and as directed. |
| 137 | S&F in replacement flame proof weather proof energy efficient LEDflood light fitting 60W, input voltage 230VAC, 50Hz with ingress protection IP 65, CRI >70, PF>0.9, minimum 25000 burning hours,LM-79, lumen efficacy ≥100 lumen/watt, THD> 20, CRCA housingincluding all fixing arrangement like clamps, nuts, bolts, washers with all accessories pre-wired and connecting with twin core twisted flexible copper conductor cable with all necessary staging, etc. for fixing at any locations including taking down the old unserviceable fittings complete all as specified and as directed. |
| 138 | Supply, installation, testing & commissioningof powder coated compartmentalized LT panel, of suitable size, symetrical with overload, short circuit and earth fault protection, having bus bar chambers with rated aluminium bus bar, duly insulated with coloured PVC sleeves as per standard code, rigidly mounted on bakelite / DMC insulators (square / round with good insulation resistance), fabricated out of 3.15mm thick CRCA sheet steel, totally enclosed, dust proof, weather proof, vermin proof, double door with suitable locking arrangements and suitable for operation on 415V, 50Hz, 3 phase, 4 wire AC supply with gland plates, cable glands, lifting hooks, ventilating louvers, bus bars, inter connections, earthing, labeling electrical interlocking, suitable for termination of cables, mounted/fixed on and including MS angle iron stand /frame 40cm height from FFL, fabricated out of 50x50x6mm thick MS angle legs (4Nos.) duly grouted in ground with PCC 1:3:6 type C1 painting all exposed metal surfaces with two coats of synthetic enamel paint (of approved tint) over a coat of red oxide zinc chrome primer with, accommodating and including the under mentioned and connecting up complete all as specified and as directed |
| 139 | (a) Panel with the following: (i) 600A rated aluminium bus bar 04 Nos (three phase & Neutral)(ii) MCCB 400A, 415V, 45KA, four pole - 1 Nos.(Incoming)(iii) MCCB 200A, 415V, 25KA, three pole - 2 Nos.(Outgoing)(iv) MCCB 160A, 415V, 25KA, three pole - 3 Nos.(Outgoing)(v) Digital ampere meter and voltmeter -01 Nos(vi) Indication lamp R,Y,B, N -01 Set |
| 140 | (b) Panel with the following: (i) 600A rated aluminium bus bar 04 Nos (three phase & Neutral)(ii) MCCB 250A, 415V, 45KA, four pole - 1 Nos.(Incoming)(iii) MCCB 200A, 415V, 25KA, three pole - 1 Nos.(Outgoing)(iv) MCCB 125A, 415V, 25KA, three pole - 3 Nos.(Outgoing)(v) Digital ampere meter and voltmeter -01 Nos(vi) Indication lamp R,Y,B, N -01 Set |
| 141 | S&F in replacement 1100 Volts grade heavy duty cable PVC insulated aluminium solid conductor served with inner sheathing of PVC tape and overall PVC sheathed in service connection suspended by insulating hangers not more than 1 mtr apart incl 4 mm suspension wire one twin core flat of size 6 sqmm sold aluminium conductor. complete all as specified and as directed. |
| 142 | All as per item No.141.00 here-in-above but twin core 10 sqmm complete all as specified and as directed. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail