| 1 | Taking down chowkats or frame with shutters (without taking off shuttters from frames) size exc 1.5 Sqm but not exc 4 sqm each each and removing from site and making good disturbed surfaces as per existing specifications complete all as specified and directed. |
| 2 | Taking down chowkats or frame with shutters (without taking off shuttters from frames) size n .exc 1.5 Sqm and removing from site and making good disturbed surfaces as per existing specifications complete all as specified and directed. |
| 3 | Supply and fixing powder coated aluminium door shutters, aluminium section weighting 0.55 Kg/ RM including necessary jointing cleats, glazing clips, rubber neoprene packing, handles 2 Nos in each door, hinges, powder coated aluminium snap beading screws etc complete all as specified and directed. |
| 4 | Supply and fixing for powder coated aluminium window and ventilator shutters with aluminium grill, side hund type without sash bars aluminium section weighing 0.55Kg/RM including necessary hointing cleats, glazing clips, rubber packing anodised aluminium snap beading, screws anodised aluminium fitting such as peg stay 150mm long (01no) hinges type B21, 100mm long (02 Nos) suitable handle (01 No) complete all as specified and directed. |
| 5 | Taking down of aluminium partition including glass and particle board etc complete all as specified and directed. |
| 6 | Supply and fixing for powder coated aluminium partition fixed type/with out sash bars aluminium section weighing 0.55kg/RM incl necessary jointing cleats, glazing clips rubber packingaluminium snap beading, screw etc complete all as specified and directed. |
| 7 | Supply and fixing powder coatedaluminium frame for doors, windows ventilators with one or more rebates including jointing cleat for fixing etc complete all as specified and directed. |
| 8 | Supply and fixing ordinary quality sheet glass 5mm thick in panels of aluminium door and window etc fixed with aluminium clip and rubber beading all as specified n exc 0.5 sqm complete all as specified and directed. |
| 9 | Supply and fixing ordinary quality sheet glass 5mm thick in panels of aluminium door and window etc fixed with aluminium clip and rubber beading all as specified exc 0.5 sqm complete all as specified and directed. |
| 10 | Material and labourfor 9mm thick Prelaminated particle, board, exterior grade, prelaminated both side with both side decorative choice laminations fixed with screws/beading to timber/aluminium frame work complete all as specified and directed. |
| 11 | Supply and fixing in repair aluminium (die cast) body door closer hydraulically regulated designation No.3 universal type suitable for aluminium door shutters of width 851 to 1000mm and of weight between 61 to 80Kg complete all as specified and directed. |
| 12 | Supply and fixingfor double action floor spring hydraulically regulated made ou of minium 1.25mm thick aluminium allooy sheet foundation box, main body with stainless steel cover governing pivot made of brass, other parts made of MS heavy duty and fixed complete all as specified and directed. |
| 13 | Material and labourfor 12mm thick Prelaminated particle, board, exterior grade, prelaminated one side with decorative choice laminations & other side balancing white lamination, fixed with screws to timber frame work and fixed in repairs complete all as specified and directed. |
| 14 | Supply and fixing in repairs Harrison rails 20 mm dia mild steel chromium plated curtain rail fixing with brackets stops complete all as specified and directed. |
| 15 | Dismantling wall and ceiling boards (fibre, pulp, insulation etc) any thickness, including cover fillets and grid frame work, complete all as specified and directed. |
| 16 | M & L anodised aluminium snap grid frame work of size 605 x605mm for false ceiling including hanger 6mm dia GI (upto 1200mm length) adjusting level fixed to roof slab by means of ceiling cleats made out of GI flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5 mm dia 40mm long complete all as specified and directed. |
| 17 | M&L for 8 mm thick Exposed metal frame ceiling with calcium silicate board of siliceous and calcareous material reinforced with cellulose fibre for fixing in 600 mm x 600mm grid complete all as specified and directed. |
| 18 | M&Lfor hollow core 8 mm thick wood grain shade or as approved first class heavy dutyprelaminatedPVC Wall panels lining/panelling and in ceilings inclusive of solvent cement and fixing at site on PVC frame or aluminium snap grid work as per specifications and drawing complete all as specified and directed. |
| 19 | S&F in repair 3 mm thick sheet glass ordinary quality and glazing with oil putty in square n.exc 0.5 sq.m in each pane complete all as specified and directed. |
| 20 | S&F in repair 4 mm thick sheet glass ordinary quality and glazing with oil putty in square exc 0.5 sq.m in each pane complete all as specified and directed. |
| 21 | S&F in repair Stainless steel wire cloth. 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and directed. |
| 22 | Dismantling wrought iron or mild steel work of any description not otherwise provided, complete all as specified and directed. |
| 23 | Taking down cement plaster including racking out joints, hacking for key and scrubbing down with water etc complete all as specified and directed. |
| 24 | M&L for 15 mm thick cement plastering on fair faces brick or concrete surfaces in CM 1:6finished even and smooth without using extra cement complete all as specified and directed. |
| 25 | Demolition of brick work built in cement mortar in any position including all quoins, arches & pillars etc complete all as specified and directed. |
| 26 | M&L for brick work withsub class \"B\"bricksstraight or curved on plan exceeding6m mean radius built in cement mortar 1:6 complete all as specified and directed. |
| 27 | Taking down of old existing roof treatment of any description incl scrube and remove loose concrete, brick tiles, mud fuska, plaster, bitumen, oil grases and any other materials that might effect adhesion by wire brushing the surface and cleaning of the surface throughly with water and disposed off old materials from site complete all as specified and directed. |
| 28 | M&L for50 mm thick cement concrete 1:2:4 type B-0 ( using 12.5 mm graded stone aggregate) as in padding/ base on roofcomplete all as specified and directed. |
| 29 | M&L for 20 mm thick plastering in CM 1:4 on RCC roof slab, finish even and smooth for receive water proofing APP membrane using WPC @ 3% by weight of cement, complete all as specified and directed.Note : WPC will be measured and paid separately. |
| 30 | Supply only Integral water proofing compound complete all as specified and directed. |
| 31 | M/L for preparation of the plastered roof surfaces and fix the APP polymeric water proofing membrane of minimum 3 mm thickness & weighing not less than 3.0 kg / sqm of black finished reinforced with non-woven ployster 160 gsmmatt with a thermofusible finish laid over primer conforming to IS:3384-1965 @ 0.5 kg/sqm and thereafter apply compitable hot blownbitumen 85/25 @ 1.20 kg/sqm torching overlaps with a propane or a butane gas torch with a overlap of 75 mm at the sides and 100 mm at the end sealing complete all as specified and directed. |
| 32 | Disconnecting existing PVC tanks of capacity exc 250 & n exc 500 ltrers, setting aside (or loweringif required)for repairs, Cleaning and removing all scale and dirt, etc. from tanks and form mouths of circulating pipes, etc. and hoisting if required reconnecting and re-fixing the same in position and restore water supply to accommodation complete all as specified and directed. |
| 33 | Disconnecting existing PVC tanks of capacity exc 500 & n exc 1000 ltrers, setting aside (or loweringif required)for repairs, Cleaning and removing all scale and dirt, etc. from tanks and form mouths of circulating pipes, etc. and hoisting if required reconnecting and re-fixing the same in position and restore water supply to accommodation complete all as specified and directed. |
| 34 | Supply and fixing for 15 mm bore steel water tubing galvanised 15mm bore, medium grade fixed to walls and ceiling or in floor including taking down of old GI linescomplete all as specified and directed. |
| 35 | Supply and fixing in repair for 20mm bore steel water tubing galvanised, medium grade fixed to walls and ceiling or in floor including taking down of old GI linescomplete all as specified and directed. |
| 36 | Supply and fixing in repair for 25 mm bore steel water tubing galvanised, medium grade fixed to walls and ceiling or in floor including taking down of old GI linescomplete all as specified and directed. |
| 37 | M&L for preparation of newly plastered surfaces and applying two coats of cement base paint over a coat of alkali resistant primer complete all as specified and directed. |
| 38 | M&L for preparation of new or previously untreated plsatered or concrete surfaces and applying two coats of weather coat over a coat of primer complete all as specified and directed. |
| 39 | S&F 1.25mm thickness of laths steel rolling shutters, without ball bearing as specified including top cover, anchoring rod, hasp, staple and including gear operated type with bevel gear box and crank handle for rolling shutters and one shop coat of primer erected in position as indicated, completed all as specified. |
| 40 | S&F Safety lever locks mild steel with 4 leavers for rolling shutters complete all as specified and directed. |
| 41 | M&L in applying two coats of synthetic enamel paint over a coat of red oxide primer to new steel and iron surfaces over 10cm in width or girth including preparation of surfaces complete all as specified and directed. |
| 42 | Dismantling of plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof covering complete all as specified and directed. |
| 43 | S&F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm of an colour having tensile strength of 550 Mpa as in roof covering fixed on curved truss, fixed with self tapping screws complete all as specified and directed. |
| 44 | S&F Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm of an colour having tensile strength of 550Mpa as in roof covering fixed on curved truss, gutters etc fixed with self tapping screws complete all as specified and directed. |
| 45 | M&L for providing PVDF aluminium composite panels with fire resistant mineral filled core material as in interior/exterior wall cladding upto G+2 storeyed external wall surface shall consist of following (I)Aluminium sheet making a total panel thickness of 3 mm with outer surface finished with PVDF based coating 0.25mm , inner surface finished with a thin coat of polyster paint. The thickness of aluminium cover sheet shall be 0.50 mm inner core shall be of LDPE(II)MS(Mild Steel )tubeframing of section 25 mmx50 mm x1.50mm thick , (III) MS (Mild steel)tubegrid shall not be exceed 1.0 sqm each, theMS Tube grid not more than 1 m c/c shall be fixed with MS angle 30x30x5 mm projected 150mm from surface of wall, (IV) Colourshall be approved by GE. (V) Joint shall be sealed with silicon weather proof sealing compound with help of masking Tapes.Note: Canopy, borders,projections etc will be measured in sqm for payment purpose. |
| 46 | M&L for cut outs/ metal sign board of dogs Size 1.2m X 1.5mPVDF aluminium composite panels with fire resistent mineral filled core materialprinted with vinaylOR print with 3 M retro reflective tapes on ACP Sheetfixed on the ACP Sheet with the help of high bond double side taps Of 3M Grey VHB taps 2 mm thick including taking down of old sign board complete all as specified and directed.Note: coloure and Type of dogs choice shall be approved by GE. |
| 47 | M&L for 3dStainless steelLED lighted letters OR print with 3 M retro reflective tapes on ACP Sheet above 12 inch including taking down of old ss letters complete all as specified and directed Note: Size shall be approved by GE. |
| 48 | M&L for Steel work in tubular trusses and purlins including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to IS 1161-1979 grade St.-240 complete all as specified and directed. |
| 49 | M&L for Structural steel, rolled section such as joist, beam, channel, angle, tee, in available lengths Fe 410-W(Gde-E-250) quality-A complete all as specified and directed. |
| 50 | M/L for Framed work such as grills, gratings etc., with ends of bars shouldered and/or riveted, or forget into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe 410-0 or Fe 310-0 complete all as specified and directed. |