| Sl. No. | Item Description |
| 1 | Schedule \"A\" Part – I to Schedule \"A\" Part – XX:NOTE: Schedule \"A\" Part – I to Part – XX are prepriced by MES. Bidders shall insert their Lumpsum amount in Green coloured field under Column - 6 only |
| 2 | Lumpsum price worked out by the contractor for \"Buildings & Structures\",as listed in Schedule \"A\" Part – I . |
| 3 | Lumpsum price worked out by the contractor for \"Site Clearance / Earthwork/ Excavation\", as listed in Schedule \"A\" Part – II . |
| 4 | Lumpsum price worked out by the contractor for \"Pile foundation\", as listed in Schedule \"A\" Part – III |
| 5 | Lumpsum price worked out by the contractor for \"Internal Electrification\", as listed in Schedule \"A\" Part – IV . |
| 6 | Lumpsum price worked out by the contractor for \"Internal Water Supply\", as listed in Schedule \"A\" Part – V . |
| 7 | Lumpsum price worked out by the contractor for \"Sewage Disposal B/R\",as listed in Schedule \"A\" Part – VI . |
| 8 | Lumpsum price worked out by the contractor for \"External Water Supply\", as listed in Schedule \"A\" Part – VII |
| 9 | Lumpsum price worked out by the contractor for \"External Electrification\",as listed in Schedule \"A\" Part – VIII |
| 10 | Lumpsum price worked out by the contractor for Roads/Paths/Hard Standing\", as listed in Schedule \"A\" Part – IX . |
| 11 | Lumpsum price worked out by the contractor for \"Area drainage\", as listed in Schedule \"A\" Part – X |
| 12 | Lumpsum price worked out by the contractor for \"Chain link fencing/ Wall/ Gate\",as listed in Schedule \"A\" Part – XI |
| 13 | Lumpsum price worked out by the contractor for \"Fire fighting and fire alarm system\", as listed in Schedule \"A\" Part – XII |
| 14 | Lumpsum price worked out by the contractor for \"Lightning Protection\", as listed in Schedule \"A\" Part – XIII |
| 15 | Lumpsum price worked out by the contractor for \"PVC Conduit\", as listed in Schedule \"A\" Part – XIV |
| 16 | Lumpsum price worked out by the contractor for \"Solar water heater\", as listed in Schedule \"A\" Part – XV |
| 17 | Lumpsum price worked out by the contractor for \"Central Air conditioning \",as listed in Schedule \"A\" Part – XVI . |
| 18 | Lumpsum price worked out by the contractor for \"Arboriculture\", as listed in Schedule \"A\" Part – XVII |
| 19 | Lumpsum price worked out by the contractor for \"Cooling Appliances\", as listed in Schedule \"A\" Part – XVIII |
| 20 | Lumpsum price worked out by the contractor for \"Mechanical laundry\", as listed in Schedule \"A\" Part – XIX |
| 21 | Lumpsum price worked out by the contractor for \"Retaining wall \", as listed in Schedule \"A\" Part – XX |
| 22 | Schedule \"A\" Part - XXI [Miscellaneous Items] |
| 23 | Internal Electrification |
| 24 | Point Wiring complete with 1100 Volts, FRLSH Grade, 1.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor Cable, confirming to IS - 694 drawn through and including heavy duty PVC Conduit, 20 mm dia including all accessories concealed in Walls / Roofs / Floors / Ceiling etc. and Pressed Metal Flush Box made out of 2mm thick MS Sheet of suitable size and 3 mm thick Hylam Sheet top cover for fixing switches, fittings, regulators etc concealed in walls, including 1100 Volts, FRLSH Grade, 1.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable as earth continuity conductor with colour coding and connecting to Earth Dolly for One Light / Fan Point / Bell Point controlled by One Switch complete all as specified. |
| 25 | All as per Serial Item No. 21 above but One 3 Pin Switch Socket Outlet 5 Amps on Independent Board complete all as specified. |
| 26 | All as per Serial Item No. 21 above but One 3 Pin Switch Socket Outlet 5 Amps on same Board complete all as specified. |
| 27 | All as per item No.21 here-in-before but controlled by two two way switch complete all as specefied and directed. |
| 28 | All as per Serial Item No. 21 above but one 3 Pin Switch Socket Outlet 16 Amps on independent board, with 1100 Volts, FRLSH grade, 4.0 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor Cable confirming to IS - 694 and including 1100 Volts, FRLSH grade, 4.0 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor Cable as Earth Continuity Conductor. |
| 29 | Supply and fixing of ceiling fan complete with blades, down rod and other accessories, AC 230 Volts, 1200 mm sweep, min air delivary 210 CFM with service value 6.00, BEE, 5 star rated with brushless direct current motor [BLDC] including connecting with 1.0 Sqmm, 2 core copper conductor from ceiling rose complete all as specified and as directed. |
| 30 | Supply and fixing exhaust fan, 250mm sweep, plastic body, heavy duty with louvers, AC single phase, 230 volts, connection with 1.0 sqmm copper conductor flexible wire from ceiling rose including making necessary opening and making good the disturbed surface complete all as specified and as directed. |
| 31 | Supply and fixing exhaust fan, 300 mm sweep, metallic body, heavy duty , AC single phase, 230 volts , 5 star rating, connection with 1.0 sqmm copper conductor flexible wire from ceiling rose including making necessary opening and making good the disturbed surface complete all as specified and as directed. |
| 32 | S&F energy efficient LED Tube light fitting with tube 5W or nearest size, 240 Volts, 50 Hz, surface mounted, decorative ultra slim square profile LED light fixture with extruded polycorbonate environmental friendly, energy efficient ready to use pack of complete mounting brackets including connecting up with 1.0 Sqmm 3 core flexible copper conductor cable complete all as specified as directed |
| 33 | S&F energy efficient LED Tube light fitting with tube 10W or nearest size, 240 Volts, 50 Hz, surface mounted, decorative ultra slim square profile LED light fixture with extruded polycorbonate environmental friendly, energy efficient ready to use pack of complete mounting brackets includingconnecting up with 1.0 Sqmm 3 core flexible copper conductor cable complete all as specified as directed |
| 34 | S&F energy efficient LED Tube light fitting with tube 18/20W or nearest size, 240 Volts, 50 Hz, surface mounted, decorative ultra slim square profile LED light fixture with extruded polycorbonate environmental friendly, energy efficient ready to use pack of complete mounting brackets includingconnecting up with 1.0 Sqmm 3 core flexible copper conductor cable complete all as specified as directed |
| 35 | S & F energy efficient LED security light fitting with tube 30 watts new generatiionenergy saving & environmental friendly long life, made up of pressure die cast aluminium housing with high efficient LED as lighting source and PC cover having top opening separate driver compartment with IP66 protection pre-wired and connecting up with with 1.0 Sqmm copper conductor cable upto connector including 1.5 metre long GI tubing light grade bracket of 32 mm dia bend to shape for fixing on wall/ polewith suitable MS bracket nuts, bolts etc., complete all as specified and directed. |
| 36 | Supply, Install, testing and commissioning of AC three phase static electronic meter of accuracy class 1.0, 240 Volts, 50 Hz, with backlite LCD display of rating 10-60 Amps six month historywith the following specifications complete all as specified and directed.[a] AC Three Phase Four wire, tamper proof, Static Meter of Class 1.0, 415 V, 50 Hz, 10 A-60 A conforming to IS-16444 and relevant IEC standards with incuilt 865-867 MHz Radio Frequency communication facility with self healing Mesh network with default and on demand display, biling data generation facility, anti-tamper features, Microprocessor and LED/LCD based circuitry.[b] Meter should support the following data: 30 Min instantaneous data for voltage, current, power factor, power, cumulative energy and frequency, 30 load survey data for energy, monthly billing survey for cumulative energy and Max Demand.[c] Meter should have connect/ disconnect functionally operable from prepaid billing software.[d] The meter should support open communication protocolDLMS with the software MAKE: Secure, L&T Schneider |
| 37 | M & Lforsub-main wiring with 4.0 sqmm nominal area two single core PVC insulated unshethed multi-stranded FRLS copper conductor cable including one 4.0 sqmmPVC insulated unshethed multi-stranded copper conductorcable for earth wiredrawn through 20 mm dia PVCconduit complete all as specified and as directed.Note :(i) Two run of 4.0 Sqmm + one run of 4.0 Sqmm as a earth wire cable + one run of PVC conduitshall be measured as an one Unit. |
| 38 | Supply and fix polycarbonate meter box as per IS 14772 with IP -55 weather proof and temperature proof,fire retardant suitable for three phase smart pre-paid meter viewing glass, concealed hinge and earth bolt plugged including cable glands for incoming and outgoing cables and locking arrangement for top cover of the box without affecting communication complete all as specified and directed. |
| 39 | M & Lforsub-main wiring with 10.0 sqmm nominal area four single core PVC insulated unshethed multi-stranded FRLS copper conductor cable including one 10.0 sqmmPVC insulated unshethed multi-stranded copper conductorcable for earth wiredrawn through PVCconduit of suitable size complete all as specified and as directed.Note :(i) Four run of 10.0 Sqmm + one run of 10.0 Sqmm as a earth wire cable + one run of PVC conduitshall be measured as an one Unit. |
| 40 | S & F MCCB DB, vertical double door, TPN, 4 way, sheet steel, with 200 Amps rated bus bar, 415 Volts, 50 Hz, IP : 43 protection,concealed in walls, including provision of MCCB FP 40 Amps, 10 KA as incommer and outgoing circuits, filling the empty with blanks, making good the disturbed area as per existing surfacecomplete all as specified and as directed. |
| 41 | S & F MCB DB, vertical double door, TPN, 6 way, sheet steel, , 415 Volts, 50 Hz, IP : 43 protection,concealed in walls, including provision for fixing RCBO, FP as incommer and outgoing circuits, MCB SP/TP filling the empty with blanks, making good the disturbed area as per existing surfacecomplete all as specified and as directed. |
| 42 | Supply and fixing wall mounted fan, 450mm sweep,AC single phase, 230 volts, connection with 1.0 sqmm copper conductor flexible wire from ceiling rose, 5 star rating complete all as specified and as directed. |
| 43 | Earthing complete with Galvanised steel earth plate electrode 600 X 600 X 6 mm thick burried directly in ground [earth pit not less than 2.25 m deep below ground level] with top edge of plate not less than 1.50 m below normal ground level connected to 25 X 4mm GI Strip [Earth Lead] and GI pipe 50 mm, Medium Grade for earthing lead protection to the extent of maximum 7.5m, Earth Plate Electrode surrounded by 150mm thick packed layers of Charcoal and Common Salt filled in alternate layers, connected to the plate by means of GI Bolts & Nuts complete all as per Electrical plate No. 3 of SSR Part - I, connected to panel / DB including testing on completion including main earthing, Charcoal, Common Salt, PCC [1:2:4, Type B1] Pit with RCC 1:2:4, Type B1 Cover, 50 mm thick with 6 Nos, 8 mm dia TMT bars in both ways, MS frame made with 40 X 40 X 6 mm Angle Iron, MS Funnel with 20 mm bore, medium grade GI Watering pipe, wire mesh, earth work excavation, return filling, removal of surplus soil etc. complete all as specified and as directed. |
| 44 | Earthing complete with Galvanised steel earth plate electrode 600 X 600 X 6 mm thick burried directly in ground [earth pit not less than 2.25 m deep below ground level] with top edge of plate not less than 1.50 m below normal ground level connected to 32 X 6mm GI Strip [Earth Lead] and GI pipe 50 mm, Medium Grade for earthing lead protection to the extent of maximum 7.5m, Earth Plate Electrode surrounded by 150mm thick packed layers of Charcoal and Common Salt filled in alternate layers, connected to the plate by means of GI Bolts & Nuts complete all as per Electrical plate No. 3 of SSR Part - I, connected to panel / DB including testing on completion including main earthing, Charcoal, Common Salt, PCC [1:2:4, Type B1] Pit with RCC 1:2:4, Type B1 Cover, 50 mm thick with 6 Nos, 8 mm dia TMT bars in both ways, MS frame made with 40 X 40 X 6 mm Angle Iron, MS Funnel with 20 mm bore, medium grade GI Watering pipe, wire mesh, earth work excavation, return filling, removal of surplus soil etc. complete all as specified and as directed. |
| 45 | Internal Water Supply |
| 46 | S & F 15 mm dia Bib taps, long body, fancy type, chromium plated screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and as directed. |
| 47 | S & F 15 mm dia Bib taps, long body, fancy type, chromium plated cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and as directed. |
| 48 | S & F CP mixer for mixing hot and cold water fancy type, chromium plated,screwed down for pipe, with two outlets going (one for bib tap and other for shower) complete all as specified and as directed. |
| 49 | S & F 15 mm dia bib tap two way, fancy type screwed down and fixed suitable for 16 mm outer dia CPVC pipe complete all as specified and as directed.Note: The maximum flow rate will be 03 LPM |
| 50 | S & F 15 mm health faucet, chromium plated, fancy type with steel flexible complete suitable for 16 mm outer dia CPVC pipe complete all as specified and as directed. |
| 51 | S & F CP mixer swan neck for mixing hot and cold water fancy type, chromium plated,fancy type screwed down for pipe, with two outlets going (one for hot and one for cold) kitchen complete all as specified and as directed. |
| 52 | External water supply |
| 53 | Material and labour for trial borewells by DTH/Rotary driling method upto 100 mtrs for each borewell in any type of soil/hard rock/soft rock inculding trialbore dia 300 mm complete all as specified and directed. |
| 54 | Material and labour Development of trial bore by reaming 300 mm to 400 mm but depth upto 30 mtrs or onward below ground level complete all as specified and directed.NOTE:- (a) Quantity under serial No 48 & 49 have been account for four (04) Nos trial bore.(b)The rate quoted by the contractor shall be deemed to include for transportation of suitable truck mounted drilling with DTH & ODEX attachment alongwith necessary accessories and T&P and site clearance for setting of machinery, data collected from electical logging etc., (d) Contractor should take into cognizance the conditions as INS chilka (Restricted area) while quoting the rates.(e) Rate quoted shall be deemed to include thesoil collection sample of every 3 mtrs deep forlab testing. |
| 55 | Supply, assembling, lowering and levelling 200 mm nominal bore UPVC ASTM SCD 120ISI marked casing blank pipe having wall thickness as per ASTMand jointing with proper Cement cealingin random length of 3 to 6 mtr, including necessary fitting i.e.,upto a depth of 30 metrefrom below ground level complete all as specified and directed by Engineer-in- Charge. |
| 56 | Supply, assembling, lowering and levelling 150 mm nominal bore UPVC ASTM SCD 120ISI marked casing blank pipe having wall thickness as per ASTMand jointing with proper Cement cealingin random length of 3 to 6 mtr, including necessary fitting i.e.,depth from 30to 400 metrefrom below ground level complete all as specified and directed by Engineer-in- Charge. |
| 57 | Supply, assembling, lowering 150mm nominal bore UPVC ASTM Sch 80ISI marked slotted pipe conforming to IS-4270-1992 with slot of suitable size and numbers as per location of intermediate aquifers including jointing with Cement cealingin random length of 3 to 6 mtr screwed and socketed in random length of 3 to 6 mtr, including necessary fitting i.ecomplete all as specified and directed. |
| 58 | Supply and packing \"P\" (Pea) gravels of size 4 to 10mm all around the linear assy up to the entire depth of bore hole upto ground level including all necessary cement works complete all as specified and directed by Engineer-in-Charge. |
| 59 | Foundation of size 100 x 100 x 100 cm at ground level for holding tubewell made of plain cement concrete 1:2:4 type B-2 (using 40mm gradedaggregates) complete all as specified and directed by Engineer-in-charge Note: Rate quoted is deemed to include necessary Earth work, excavation, returning filling, removal etc., |
| 60 | Supply, install, levelling, testing and commissioning of submerssible pumping set with outer dia of pump not exceeding 200mm having capacity 15 HP, 3 phase, 440 Volts atminimum60 mtr Head complete all as specified and directed. |
| 61 | Devlopment of borewell by means of compressor and after pumping by pump 25% extra capacity, complete all as specified and directed. |
| 62 | S&F Submerssible cable 3 core, 10 sqmm, PVC sheathed 1100 Volts grade with copper conductor including making connections and fixing complete all as specified and directed. |
| 63 | Yield test for the borewell by continuously pumping for 4 hours to determine safe pumping yield complete all as specified and directed. |
| 64 | Supply and fix in position mild steel cap made of MS plate 6mm thick with an internal threading and locking arrangement having opening for column pipe and submersible cable, for housing pipe of 200mm dia complete all as specified and directed by Engineer-in-Charge |
| 65 | Sample strata box made out of 20mm thick veneered particle board and 12mm thick plywood with 25mm x 25mm aluminium angle 2mm thick base overall length 1200mm x 750mm x 100mm with front glass sheet sliding type cover with aluminium frame all around with 2 Nos key holes plates of size 40mm x 25mm and 3mm thick complete showing name of tube well location and strata chart of ground data showing different types of strata and selection of casing pipe complete all as specified and directed. |
| 66 | S&F UPVC reducer (8 inch to 6 inch ) ,for 04 Nos of borewell complete all as specified and directed by Engr-in-Charge |
| 67 | S&F Bail plug for 04 Nos ( min 3 mts long) of borewell complete all as specified and directed. |
| 68 | S&F 100 mm dia Strainer \"Y\" type conforming to IS complete complete all as specified and directed. |
| 69 | Borewell logging geologist charges to measure the physical and chemical properties of the surrounding geological formation and soil before digging the borewell complete all as specified and directed. |
| 70 | S & F for saline sealing per borewell all as specified |
| 71 | Water analysis test regarding Physical, Chemical and microbiological examination and potability test report from authorised Govt approved agency for the following parameter :-(a) Colour (Hazen), Odour, Taste, Turbidity (NTU),PH value. (b) Total Hardness as CaCo3 (Mg/L),Iron (Mg/L), Chloride as Cl (Mg/L), Flouride as F (Mg/L), Coliforms (MPN/100ml), Sulphate as SO3 (Mg/L).(c) Total alkalinity (Mg/L), Calcium as Ca (Mg/L), Magnesium as Mg (Mg/L), Nitrate as NO3 (Mg/L), Total dissolved solids (Mg/L).(d) Cadmium as Cd (Mg/L) Copper as Cu (Mg/L) , Zinc as Zn (Mg/L), Chromium as Cr (Mg/L) , Lead as Pb (Mg/L), Maganese as Mn (Mg/L).(e) Mercury as Hg (Mg/L), Aluminium as Al (Mg/L), Arsenic as As (Mg/L). (f) Any other mandatory tests as per world Health Organisation.(g) Total suspended solids, (h) Total dissolved solids (j) Microbiological tests. |
| 72 | Supply, install, testing and commissioning of 15 HP, Three Phase 13.2- 20 A Automatic Star Delta Submersible Pump Controller accomadate in SS sheet box type enclosure IP54 and adequate space for cable terminations, Inclusive of cable gland boxcomplete all as specified and directed. |
| 73 | Supply , install, testing and commissioning of indoor meter box panel board , CPRI Approved ,IP 42made out of CRCA sheet 2 mm thick vermin proof factory made with 40 x 40 x6 mm MS angle/channel duly painted with two coats of synthetic enamel powder coated paint over a coat of metal primer with bus bar chamber comprising of high conductivity copper bus bar of capacity 200 Amps three phase and half the capacity for neutral including internal wiring with 6 sqmm copper conductor (FRLS) including PCC foundatoin suitable to accommodate the following as specified and as directed.:(a) MCCB 415 V, 125 Amps, 4 pole with electronicreleaseElectronic Earth leakage module with over load , short circuit and earth fault protection with earth module breaking capacity 16 KA- 01 Nos.(b)Digital Panel Meter Multifunctional type for Amps, Volts, KWH, Power Factor and other parameters flush mounting with LED indication lamp complete and all as per standard pratice - 1 Job(C) Panel mounted automatic star delta starter 20 HP-2 Nos(d) MCB TP 63 A, \"C\" curve ,Breaking capacity of 10kA -5 NosNote :-(i) All MCCBs / instruments / MCBs /Bus Bar shall be housed in a separate housing with on- off latches in the housing and Digital Panel Meter Multifunctional type for Amps, Volts, KWH, Power Factor and other parameters flush mounting with LED indication lamp for each outgoing complete and all as per Eng in charge. |
| 74 | Supply , install, testing and commissioning of indoor meter box panel board , CPRI Approved ,IP 42made out of CRCA sheet 2 mm thick vermin proof factory madewith 40 x 40 x6 mm MS angle/channelduly painted with two coats of synthetic enamel powder coated paint over a coat of metal primer with bus bar chamber comrising of high conductivity copper bus bar of capacity 400 Amps three phase and half the capacity for neutral including internal wiring with 6 sqmm copper conductor (FRLS) including PCC foundatoin suitable to accommodate and including the following as specified and as directed.:(a) MCCB 415 V,200 A, 4 pole with electronicreleaseElectronic Earth leakage module with over load , short circuit and earth fault protection with earth module breaking capacity 25 KA- 01 Nos.(b) Digital Panel Meter Multifunctional type for Amps, Volts, KWH, Power Factor and other parameters flush mounting with LED indication lamp complete and all as per standard pratice ---1 Job(c) MCCB 415 V,100 A, 4 pole with electronicrelease Electronic Earth leakage module with over load , short circuit and earth fault protection with earth module breaking capacity 16 KA- 03 Nos (c) MCCB 415 V,40 A, 4 pole with electronicreleaseElectronic Earth leakage module with over load , short circuit and earth fault protection with earth module breaking capacity 16 KA- 05 Nos (d) MCB TP 32 A, \"C\" curve ,Breaking capacity of 10kA -2 Nos(e) Panel mounted automatic star delta starter 50 HP-2 NosNote :- (i) All MCCBs / instruments / MCBs /Bus Bar shall be housed in a separate housing with on- off latches in the housing and Digital Panel Meter Multifunctional type for Amps, Volts, KWH, Power Factor and other parameters flush mounting with LED indication lamp for each outgoing complete and all as per Eng in charge. |
| 75 | Material and Labour for laying of Ductile Iron pipe with spigot and socket end centrifugally cast(spun) class K-9 of 250 mm dia pipe conforming to IS-8329 including testing and commissioning all as specified andas directed. |
| 76 | Material and Labour for laying of Ductile Iron pipe with spigot and socket end centrifugally cast(spun) class K-9 of 200 mm dia pipe conforming to IS-8329 including testing and commissioning all as specified andas directed. |
| 77 | Material and Labour for laying of Ductile Iron pipe with spigot and socket end centrifugally cast(spun) class K-9 of 100 mm dia pipe conforming to IS-8329 including testing and commissioning all as specified andas directed. |
| 78 | Material and Labour for laying of Ductile Iron pipe with spigot and socket end centrifugally cast(spun) class K-9 of 200 mm dia pipe conforming to IS-8329 including testing and commissioning all as specified andas directed. |
| 79 | S & F sluice valve of 250 mm dia size with cast iron body, PN 1.6, with both ends flanged, drilled at both the ends, conforming to IS-780, having SS spindle with iron wheel at top complete with nuts and bolt, washers, 3 mm rubber gasket 02 Nos complete all as specified and as directed. |
| 80 | S & F sluice valve of 250 mm dia size [Non raising type] Non-return with cast iron body, PN 1.6, with both ends flanged, drilled at both the ends, conforming to IS-780, having SS spindle with iron wheel at top complete with nuts and bolt, washers, 3 mm rubber gasket 02 Nos complete all as specified and as directed. |
| 81 | Supply and fix Cast Iron Air Valves withsingle air Outlets, conforming to IS 14845 ofsize 80 mm dia bore and fixing up in ductile Iron Water supply mains of size 200/250 mm dia complete all as specified and as directed. |
| 82 | Supply and fix foot valve of size 100 mm Complete all as specified and as directed. |
| 83 | Supply and fix foot valve of size 200 mm Complete all as specified and as directed. |
| 84 | supply ,install, testing and commisioning of Electrical Motor Driven Horizontal Centrifugal multistage type Pumpof Capacity 29 LPS (104.4 M3/HR), 70 mtr head, 37 KW, (50 HP) motor, Cast Iron Body, CI impeller, Carbon steel shaft (C-40), fitted with Gland Packing, base frame, coupling, coupling guardetc., complete set,. complete all as specified and as directed.Make :CAT No. RKB 125/27, 3 Stage (MOC-01) of KIRLOSKAR or its equivalent make as approved by GE |
| 85 | M&L for 110x 95 mm DWC with UV stabilized high density polyethylene pipes for road crossing of cable or for cable protection laid in trenches or above ground surface complete all as specified and directed. Make- Prince/Dutron/National |
| 86 | M&L for Cutting the road / hard standing for laying of pipesin trenches of size 900x600mm and making good with PCC 1 :2 :4 Type B1complete and painting with black paint , if necessary, to match with existing bituminous road colour complete all as specified and as directed. |
| 87 | M & L for masonry valve chamber of size 900 X 900 X 900 mm [interanl dimensions] comprising of 50mm thick PCC for valve including excavation and earth work in any type of soil and 200 mm thick PCC 1:4:8 type D2 foundation, brick work in CM (1:6) plastring internal surface 15 mm tick in CM (1:4) PCC (1:3:6) type B1 couping 50 x50x6 mm angle iron 3 mm thick MS plate cover complete with locking arrangement painting steel and iron surface with two coat of synthetic enamel paint over a coat of zinc chrome primer allas specified and as directed. |
| 88 | Supply and install open well Monoblock pump set 15 HP, three Phase, 415 Volts RPM 30000,50 Hz,minimum head 60 mtr, Body and impeller: cast iron , Shaft: SS and Sealing: Mechanical sealing complete as directed |
| 89 | External Electrification |
| 90 | Supply, Install, testing & commissioning of Factory Made 11 kV, 630 Amps, 21kA for 3 Seconds, AFLR, SF6 Insulated, Motorised, Outdoor 6 Way RMU Consisting of 2 Nos VCB as Incomer and 4 Nos of VCBs as Outgoing complete all specified and as directed and shall comprise of the following: The make of Vacuum Interrupter & VCB of same make as the Ring Main unit.Note: The RMU should be manufactured at OEM factory only. No other mode of manufacturing is accepted. [A]RMU shall be 11 KV, 630 Amps, 21 kA for 3 Seconds, Internal Arc 21kA/1Sec, AFLR, SF6 Insulated, Motorized, Outdoor, 6 Way RMU, Left side Extensible, Right Side Metering Unit, SACADA compatable Overload and earth fault protection Relay (Ashidha / CSPDR) with Air Insulated Bus Connected Metering unit (Type +VVVVVV+M), Type tested in line with latest IEC Standards, suitable for operations at a height up to 1000 Meters above sea level and at 40ºC Ambient Temperature, |
| 91 | Switchgear and Busbar shall all be contained in a Stainless Steel Enclosure [2.5MM thickness SS 304], nominal operating gas pressure 1.3 BAR @20 Deg C, RMU Tank shall provide Full Insulation and Switchgear shall be insensitive to the environment with Degree of Protection of IP67, Switchgear Operating Mechanism shall have an IP2X Protection and Cable Chamber shall have IP3X Protection, Outer Enclosure shall be IP 54 type tested, Painting (FRONT COVER RMU: RAL7035 & (FOR MIMIC RAL7043)) &ENCLOSURE: RAL7035 & (TOP COVER & BASE STAND IN RAL 7043)). The unit shall be internal arc proof 21kA for 1 se with AFLR clasification. tested and totally safe for human beings. The gas release & personnel safety from internal arc shall not depend on plinth design. The release of gas to be from the top of the unit, so that, even if the person is operating the unit, opening the cover, & there are personnels near the sides of the RMU/plinth, top release will ensure their safety. The hot gas release, in case of an internal arc, in no case should be from any side or bottom of the unit, as the same is unsafe for the operating personnel/pedestrian or general public. Bidder shall provide type test report to prove compliance to the Internal Arc fault IAC-AFLR as per IEC 62271-200. Internal arc testing shall be done with enclosure door in open condition, with switching devices in operation mode as per specified standard. |
| 92 | [c]Vacuum Circuit Breaker [VCB] Each shall be comprising of the following: [i] 11 KV, 630 Amps, 21 kA/ 3s, 3 Pole Manual/ Motorised VCB with 3 pole manual disconnector and 3 pole manual earth switch, manual/ motorized Spring Assisted Mechanism and Series Trip Coil – 1 No. [ii] Self Powered Relay with O/C, S/C, E/F Protection – 1 No[iii] CT Ratio 200-100/1A, Class - 1.0, 2.5VA for Metering and CT Ratio 200-100/1A, Class 5P10, 2.5 VA for Protection – 1 Set each[iv] Live Cable Indicator with indications at the Front and Three Inlets to check the Synchronization of Phases – 1 No[v] Cable Termination Bushing suitable for up to 1 Run, 3 Core, 185 Sq.mm, XLPE Cable – 1 Set[vi] Cable Termination Cover Boots [Push on type] – 1 Set[D] Air Insulated Bus Connected Metering Unit comprising the following: – 1 Set[i] Air Insulated Enclosure with necessary Bus Connection – 1 No[ii] PT 11KV / RT 3 / 110V / RT3, 25 VA, Class-1.0 – 1 Set[iii] Voltmeter with Selector Switch – 1 No[iv] R / Y / B Indicating Lamps – 1 Set[v] 11 KV / 230V AC, Class 1, 500VA Control Transformer – 1 No[vi] Battery and Battery Charger, 12 Ah, [I/P-230V AC, O/P - 24V DC]–1 No |
| 93 | Note:[a] An operator situated in front, lateral and rear [A-FLR 21 kA – 1 Sec, Downwards Exhaust, for Tank as well as Cable Compartment] of the RMU Switch board during an internal fault shall not be exposed to the effects of Arcing. Internal Arc Type Test Report for IAC AFLR 21 kA for 1 Sec for both Tank & Cable Box shall be for minimum as per OEM standards.[b]All operations shall of the RMU shall be as per OEM standards. [c] Copy of the Type Test reports as per latest IEC shall be submitted along with drawings for approvals. |
| 94 | Supply, install, testingand commissioning ofLT indoortype panel board of suitable size, pedestal mounted, CPRI approved totally enclosed, dust and vermin proof, front side openable, type IP 54 protection made of CRCA sheet outer and inner shell2.00 mm thickand 50x50x6 mm frame of size as per IS and having proper locking arrangement by key in front and back side door suitable for 440 volts, 50 Hz, 3 phase 4 wire system including bottom of the outer shell contains a detachable plate having provision for entry of armoured cable of adequate size of cable glands of suitable size for incoming and outgoing cables and comprising the dimension of outer shall be adequate to accommodate inner shell described below 50mm space all around and shall be fabricated in suchway that inner shell along with its control gear and accessories and including following accessories and mounted on PCC Plat form min 35 cm from ground level andgrouted in PCC 1:3:6, 100 mm thick, 0.25 m all round the panel board. Complete with the following items housed in:-BUSBar:- Copper bus bar rated 1.5 times of incoming MCCB/ACB |
| 95 | (a)Incomming :-(i) ACB 1600 Amps, 4 Pole, 415 V, with Thermal Magnetic Release (Manual Drawout type) - 01 No (iii) Digital Panel Meter Multifunctional type for Amps, Volts, KWH, Power Factor and other parameters flush mounting . - 01 Nos(iv)LED indicating lamps - 1 [set of 3](b)Outgoing :- (i) ACB 800 Amps, 3 pole, 50 KA, 415V- 01 Nos(Adjustable Type)(ii)MCCB 500 Amps, 3 pole, 36 KA, 415V- 01 Nos(Adjustable Type) (iii) MCCB 250 Amps, 3 pole, 36 KA, 415V- 02 Nos(Adjustable Type)01 Nos Spare (iv) MCCB 200 Amps, 3 pole, 36 KA, 415V- 02 Nos(Adjustable Type) (v) LED indicating lamps-1 set of 3 |
| 96 | LT Panel boardmade out of CRCA sheet 3.15 mm thick outdoor Pedestal type totally enclosed with front and rear opening, hinged doors with projected an raised platform of suitable size weather and water proof with necessary locking arrangements along with lugs, cable glands of various sizes for cables, danger notice plate, strickering of Switcher gear about termination of switch gear, cable connector for connecting multi cables located in cable chamber terminated form the switchergear, and the nuts/ bolts etc used are to be made of rust proof material incl as per IS: 8623 tinned copper bus bar with insulators suitable for three phase and four wire LT AC, 50 Hz 415 V 300 A capacity complete with powder coating, necessary internal electric connection as required and provision of the following |
| 97 | a) MCCB 200 A AC 3 Phase 415 V, 50 Hz 4 polebreaking capactiy 25 kA with adjustable type thermal and magnetic setting relays - 01 Nos.( DG incoming)b) MCCB 100 A AC 3 Phase 415 V, 50 Hz 4 polebreaking capactiy 25kA with adjustable type thermal and magnetic setting relays - 08 Nosc) MCCB 32 A AC 3 Phase 415 V, 50H z 4 polebreaking capactiy 25 kA with adjustable type thermal and magnetic setting relays - 01 Nod) MCB10 A SPN AC 1 Phase 230 V, 50 Hz 2 polecapactiy 10kA - 02 Nose) MCB 32 ASPN AC 1 Phase 230 V, 50 Hz 2 pole capactiy 10kA - 03 Nosf) Intelligent Panel meter to measure voltage, current, frequency, power factor, kWH, etc with all connected CTs g) LED Indicating Lamps for each phase with colour coed Red Yellow Blue for R, Y and B Phases |
| 98 | Supply, install, testingand commissioning ofLT indoortype panel board of suitable size, pedestal mounted, CPRI approved totally enclosed, dust and vermin proof, front side openable, type IP 54 protection made of CRCA sheet outer and inner shell2.00 mm thickand 50x50x6 mm frame of size as per IS and having proper locking arrangement by key in front and back side door suitable for 440 volts, 50 Hz, 3 phase 4 wire system including bottom of the outer shell contains a detachable plate having provision for entry of armoured cable of adequate size of cable glands of suitable size for incoming and outgoing cables and comprising the dimension of outer shall be adequate to accommodate inner shell described below 50mm space all around and shall be fabricated in suchway that inner shell along with its control gear and accessories and including following accessories and mounted on PCC Plat form min 35 cm from ground level andgrouted in PCC 1:3:6, 100 mm thick, 0.25 m all round the panel board. Complete with the following items housed in :-BUSBar:- Copper bus bar rated 1.5 times of incoming MCCB/ACB |
| 99 | (a)Incomming :-(i) ACB 800A,4pole thermal magnetic - 01 No(ii)Digital Panel Meter Multifunctional type for Amps, Volts, KWH, Power Factor and other parameters flush mounting . - 01 Nos(iii)LED indicating lamps-1 set of 3(b)Outgoing :-(i)MCCB 250 Amps, 3 pole, 36 KA, 415V- 01 Nos(Adjustable Type) (ii)MCCB 160 Amps, 3 pole, 36 KA, 415V- 05 Nos(Adjustable Type)(iii)LED indicating lamps-1 set of 3 |
| 100 | Supply, install, testingand commissioningof LT indoor type panel board of suitable size, pedestal mounted, CPRI approved totally enclosed, dust and vermin proof, front side openable, type IP 54 protection made of CRCA sheet outer and inner shell 2.00 mm thickand 50x50x6 mm frame of size as per IS and having proper locking arrangement by key in front and back side door suitable for 440 volts, 50 Hz, 3 phase 4 wire system including bottom of the outer shell contains a detachable plate having provision for entry of armoured cable of adequate size of cable glands of suitable size for incoming and outgoing cables and comprising the dimension of outer shall be adequate to accommodate inner shell described below 50mm space all around and shall be fabricated in suchway that inner shell along with its control gear and accessories and including following accessories and mounted on PCC Plat form min 35 cm from ground level andgrouted in PCC 1:3:6, 100 mm thick, 0.25 m all round the panel board. Complete with the following items housed in :-BUSBar:- Copper bus bar rated 1.5 times of incoming MCCB/ACB |
| 101 | (a)Incomming :-(i) MCCB200 Amps 4 Pole 36 KA, 415 V -01 No (ii)Digital Panel Meter Multifunctional type for Amps, Volts, KWH, Power Factor and other parameters flush mounting . - 01 Nos(iii)LED indicating lamps-1 set of 3(b)Outgoing :-(i)MCCB 63 Amps, 3 pole, 16 KA, 415V- 05 Nos(Adjustable Type)(ii)MCCB 40Amps, 3 pole, 16 KA, 415V- 02 Nos(Adjustable Type)(iii)LED indicating lamps-1 set of 3 |
| 102 | Supply, installing, testingand commissioningofLT indoortype panel board of suitable size, pedestal mounted, CPRI approved totally enclosed, dust and vermin proof, front side openable, type IP 54 protection made of CRCA sheet outer and inner shell2.00 mm thickand 50x50x6 mm frame of size as per IS and having proper locking arrangement by key in front and back side door suitable for 440 volts, 50 Hz, 3 phase 4 wire system including bottom of the outer shell contains a detachable plate having provision for entry of armoured cable of adequate size of cable glands of suitable size for incoming and outgoing cables and comprising the dimension of outer shall be adequate to accommodate inner shell described below 50mm space all around and shall be fabricated in suchway that inner shell along with its control gear and accessories and including following accessories and mounted on PCC Plat form min 35 cm from ground level andgrouted in PCC 1:3:6, 100 mm thick, 0.25 m all round the panel board. Complete with the following items housed in :-BUSBar:- Copper bus bar rated 1.5 times of incoming MCCB/ACB |
| 103 | (a)Incomming :-(i) MCCB250 Amps 4 Pole 36 KA, 415 V, (Microprocessor release) (ii)Digital Panel Meter Multifunctional type for Amps, Volts, KWH, Power Factor and other parameters flush mounting- 01 Nos(iii)LED indicating lamps-1 set of 3(b)Outgoing :- (i)MCCB 100 Amps, 3 pole, 16 KA, 415V- 3 Nos(Adjustable Type)(ii)MCCB 63 Amps, 3 pole, 16 KA, 415V- 3 Nos(Adjustable Type)(iii)LED indicating lamps-1 set of 3 |
| 104 | Supply, installing, testingand commissioning ofLT indoortype panel board of suitable size, pedestal mounted, CPRI approved totally enclosed, dust and vermin proof, front side openable, type IP 54 protection made of CRCA sheet outer and inner shell2.00 mm thickand 50x50x6 mm frame of size as per IS and having proper locking arrangement by key in front and back side door suitable for 440 volts, 50 Hz, 3 phase 4 wire system including bottom of the outer shell contains a detachable plate having provision for entry of armoured cable of adequate size of cable glands of suitable size for incoming and outgoing cables and comprising the dimension of outer shall be adequate to accommodate inner shell described below 50mm space all around and shall be fabricated in suchway that inner shell along with its control gear and accessories and including following accessories and mounted on PCC Plat form min 35 cm from ground level andgrouted in PCC 1:3:6, 100 mm thick, 0.25 m all round the panel board. Complete with the following items housed in :-BUSBar:- Copper bus bar rated 1.5 times of incoming MCCB/ACB |
| 105 | (a)Incomming :-(i) MCCB400 Amps 4 Pole 36 KA, 415 V, (Microprocessor release) (ii)Digital Panel Meter Multifunctional type for Amps, Volts, KWH, Power Factor and other parameters flush mounting- 01 Nos(iii)LED indicating lamps-1 set of 3(b)Outgoing :-(i)MCCB 63 Amps, 3 pole, 16 KA, 415V- 13Nos(Adjustable Type)(ii)LED indicating lamps-1 set of 3 |
| 106 | Supply, installing, testingand commissioningofLT indoortype panel board of suitable size, pedestal mounted, CPRI approved totally enclosed, dust and vermin proof, front side openable, type IP 54 protection made of CRCA sheet outer and inner shell2.00 mm thickand 50x50x6 mm frame of size as per IS and having proper locking arrangement by key in front and back side door suitable for 440 volts, 50 Hz, 3 phase 4 wire system including bottom of the outer shell contains a detachable plate having provision for entry of armoured cable of adequate size of cable glands of suitable size for incoming and outgoing cables and comprising the dimension of outer shall be adequate to accommodate inner shell described below 50mm space all around and shall be fabricated in suchway that inner shell along with its control gear and accessories and including following accessories and mounted on PCC Plat form min 35 cm from ground level andgrouted in PCC 1:3:6, 100 mm thick, 0.25 m all round the panel board. Complete with the following items housed in :-BUSBar:- Copper bus bar rated 1.5 times of incoming MCCB/ACB |
| 107 | (a)Incomming :-(i) MCCB160 Amps 4 Pole 36 KA, 415 V, (Microprocessor release) (ii)Digital Panel Meter Multifunctional type for Amps, Volts, KWH, Power Factor and other parameters flush mounting- 01 Nos(iii)LED indicating lamps-1 set of 3(b)Outgoing :-(i)MCCB 63 Amps, 3 pole, 16 KA, 415V- 08 Nos(Adjustable Type)(ii)MCCB 40 Amps, 3 pole, 16 KA, 415V- 1 Nos(Adjustable Type) (iii)Timer electronic type 01 Nos |
| 108 | Supply, installing, testingand commissioning ofLT indoortype panel board of suitable size, pedestal mounted, CPRI approved totally enclosed, dust and vermin proof, front side openable, type IP 54 protection made of CRCA sheet outer and inner shell2.00 mm thickand 50x50x6 mm frame of size as per IS and having proper locking arrangement by key in front and back side door suitable for 440 volts, 50 Hz, 3 phase 4 wire system including bottom of the outer shell contains a detachable plate having provision for entry of armoured cable of adequate size of cable glands of suitable size for incoming and outgoing cables and comprising the dimension of outer shall be adequate to accommodate inner shell described below 50mm space all around and shall be fabricated in suchway that inner shell along with its control gear and accessories and including following accessories and mounted on PCC Plat form min 35 cm from ground level andgrouted in PCC 1:3:6, 100 mm thick, 0.25 m all round the panel board. Complete with the following items housed in :-BUSBar:- Copper bus bar rated 1.5 times of incoming MCCB/ACB |
| 109 | (a)Incomming :-(i)MCCB 250 Amps, 4 pole, 36 KA, 415V- 05 Nos(Adjustable Type)(ii)Digital Panel Meter Multifunctional type for Amps, Volts, KWH, Power Factor and other parameters flush mounting . - 01 Nos(iii)LED indicating lamps-1 set of 3(b)Outgoing :- (i)MCCB 160 Amps, 3 pole, 36 KA, 415V- 01 Nos(Adjustable Type)(ii)MCCB 125 Amps, 3 pole, 36 KA, 415V- 02 Nos(Adjustable Type) (iii)MCCB 100 Amps, 3 pole, 36 KA, 415V- 01Nos(Adjustable Type)(iv)MCCB 63 Amps, 3 pole, 36 KA, 415V- 01Nos(Adjustable Type) |
| 110 | Supply, installing, testingand commissioning ofLT indoortype panel board of suitable size, pedestal mounted, CPRI approved totally enclosed, dust and vermin proof, front side openable, type IP 54 protection made of CRCA sheet outer and inner shell2.00 mm thickand 50x50x6 mm frame of size as per IS and having proper locking arrangement by key in front and back side door suitable for 440 volts, 50 Hz, 3 phase 4 wire system including bottom of the outer shell contains a detachable plate having provision for entry of armoured cable of adequate size of cable glands of suitable size for incoming and outgoing cables and comprising the dimension of outer shall be adequate to accommodate inner shell described below 50mm space all around and shall be fabricated in suchway that inner shell along with its control gear and accessories and including following accessories and mounted on PCC Plat form min 35 cm from ground level andgrouted in PCC 1:3:6, 100 mm thick, 0.25 m all round the panel board. Complete with the following items housed in :-BUSBar:- Copper bus bar rated 1.5 times of incoming MCCB/ACB |
| 111 | (a)Incomming :-(i) MCCB400 Amps 4 Pole 36 KA, 415 V, (Microprocessor release) (ii)Digital Panel Meter Multifunctional type for Amps, Volts, KWH, Power Factor and other parameters flush mounting- 01 Nos(iii)LED indicating lamps-1 set of 3(b)Outgoing :-(i)MCCB 100 Amps, 3 pole, 16 KA, 415V- 06 Nos(Adjustable Type) (ii)MCCB 63 Amps, 3 pole, 16 KA, 415V- 02 Nos(Adjustable Type) (iii)LED indicating lamps-1 set of 3 |
| 112 | Supply, installing, testingand commissioningofLT indoortype panel board of suitable size, pedestal mounted, CPRI approved totally enclosed, dust and vermin proof, front side openable, type IP 54 protection made of CRCA sheet outer and inner shell2.00 mm thickand 50x50x6 mm frame of size as per IS and having proper locking arrangement by key in front and back side door suitable for 440 volts, 50 Hz, 3 phase 4 wire system including bottom of the outer shell contains a detachable plate having provision for entry of armoured cable of adequate size of cable glands of suitable size for incoming and outgoing cables and comprising the dimension of outer shall be adequate to accommodate inner shell described below 50mm space all around and shall be fabricated in suchway that inner shell along with its control gear and accessories and including following accessories and mounted on PCC Plat form min 35 cm from ground level andgrouted in PCC 1:3:6, 100 mm thick, 0.25 m all round the panel board. Complete with the following items housed in :-BUSBar:- Copper bus bar rated 1.5 times of incoming MCCB/ACB |
| 113 | (a)Incomming :-(i) MCCB100 Amps 4 Pole 36 KA, 415 V, (Microprocessor release) (ii)Digital Panel Meter Multifunctional type for Amps, Volts, KWH, Power Factor and other parameters flush mounting- 01 Nos(iii)LED indicating lamps-1 set of 3(b)Outgoing :- (i)MCCB 63 Amps, 3 pole, 16 KA, 415V- 02 Nos(Adjustable Type)(ii)MCCB 40 Amps, 3 pole, 16 KA, 415V- 1 Nos(Adjustable Type) (iii)Timer electronic type 01 Nos |
| 114 | Supply, fix ,connecting , testing and commissioning of OEM Manufactured APFC Panel (automatic and manual operation) with 7% Aluminium reactor of capacity 450 KVAR (Output) @ 440 V AC interconnection with LT Panel/ Transformer (outdoor/ indoor) with appropriate size of electric power cable 1.1KV . The stage rating shall be (9 X 50) . The APFC Panel shall be fully type tested at an independnt Laboratory and shall comply with IEC 61439-1&2 and IEC 61921, IS-16636-2017. The degree of protection of enclosure system of the APFC Panel shall be min IP 54 (Outdoor) in accordance with IEC 60529. The capacitor bank shall be internet of things (IoT) enabled and communicable / integrable with BMS . The APFC Panel shall be Outdoor type confirming to IS 13341:1992 & IS13440:1993 floor mounted design fabricated out of 14 SWG CRCA Sheet treated through chemical with 8 tank process method of degreasing, derusting and phosphating powder coating (60-80 microns), painted in SIEMENS GREY (RAL 7032) shade powder coating paint, weather, dust and vermin proof suitable for humidity upto 95% and having four Nos iron legs made of 50x50x6mm thick, 60cm long angle iron below frame with front door and side/ back opening having locking arrangement prewired with copper conductor PVC insulated wire size 2.5sqmm/ extension strips and connected with suitable size thimbles & lugs. The legs duly embedded in ground (45cm) in PCC 1:3:6 type C1 (using 20mm aggregate). Cable entry from bottom. Transparent Acrylic sheet/Bakelite sheet will be provided for shrouding. Average daily temperature :+35 degree celcius max, Ambient temperature :-5 degree celcius to 40 degree celcius, Maximum altitude 2000m. Approved Make of Panel:-ABB/SCHNEIDER/SIEMENS/L&T/CMKL . The OEM \"s specified cannot authorize any other partners / sub vendors to manufacture APFC Panels on their behalf . |
| 115 | The APFC Panel manufacturered by OEM\"s only will be accepted & factory acceptance test (FAT) will be carried out at OEM\"s plant only.The APFC Panel shall be comprising of the following:- |
| 116 | S & F street light terminal boxes made out with SMC matterial shock and dust proof of inside size 295 X 195 X 100 mm as per IS and including 50 Amps TPN busbar fixed on insulator 01 No 10 Amps SP MCB earth termination with nuts and bolts and including 02 Nos of flat iron clamps of size 25 x 6 mm, nuts, bolts and washers including two coat of aluminium paint over a coat of primer on exposed steel surface and connecting all incoming and outgoing wires with Aluminium lugs of appropiate size Complete all as specified and as directed |
| 117 | S&F 3 core PVC insulated cable 3 core x1.5 sqmmfor connecting street light to junction box Complete all as specified and as directed |
| 118 | M&L for Cutting the road / hard standing for laying of pipesin trenches of size 300x300mm and making good with PCC 1 :2 :4 Type B1complete and painting with black paint , if necessary, to match with existing bituminous road colour complete all as specified and as directed. |
| 119 | S&F Precast Reinforced Cement Concrete 1:2:4 (20mm graded aggregate) of size 900x250x75mm Cable Route Indicator including embossing \"DANGER/11KV CABLE/MES\" on both sides and painted Letters with approved Colour, burried in ground for a depth of 45 Cm including necessary Earth Work, complete all as specified and as directed. |
| 120 | Fire fighting and fire alarm system |
| 121 | Supply and fix Control Panel for automatic starting of terrace pump with suitable Star Delta Automatic Starter for terrace pump , Contactors , single phase preventers and phase indicators etc., Including mounting arrangements and necessary connections etc.., completeallas specified and as directed.Note: Star -delta starter shall be measured and paid seperately. |
| 122 | Supply and fix fully automatic star delta starter suitable for 15 HP motor complete all as specified and directed. |
| 123 | Supply and fix 6 kg Capacity dry chemical power (ABC) fire exinguishers consisting of welded MS cylindrical body squeeze lever discharge valve fitted with pressure indicating guage internal discharge tube, 30 cm long high pressure discharge hose discharge nozles, suspension brackets comforming to IS finished exernally with red enamel paint and fixed to walls with brackets complete all as specified and directed. |
| 124 | Supply and fix4.5 kg Capacity CO2 type (light weight squeeze grip type) fire exinguishers consisting of welded MS cylindrical body squeeze lever discharge valve fitted with pressure indicating guage internal discharge tube, 30 cm long high pressure discharge hose discharge nozles, suspension brackets comforming to IS finished exernally with red enamel paint and fixed to walls with brackets complete all as specified and directed. |
| 125 | Supply and fix 9 Ltr Capacity mechanical foam type fire exinguishers consisting of welded MS cylindrical body squeeze lever discharge valve fitted with pressure indicating guage internal discharge tube, 30 cm long high pressure discharge hose discharge nozles, suspension brackets comforming to IS finished exernally with red enamel paint and fixed to walls with brackets complete all as specified and directed. |
| 126 | Supply and fix fire buckets (dry sand) , as per IS 2546 , all as specified and as directed. |
| 127 | Supply and fix fire buckets stand suitable to hold 02 fire buckets , all as specified and as directed. |
| 128 | Supply , installation, testing and commissioningof indoor meterbox panel board , CPRI Approved ,IP 42made out of CRCA sheet 2 mm thick vermin proof factory madewith 40 x 40 x6 mm MS angle/channelduly painted with two coats of synthetic enamel powder coated paint over a coat of metal primer with bus bar chamber comrising of high conductivity copper bus bar of capacity 200 Amps three phase and half the capacity for neutral including internal wiring with 6 sqmm copper conductor (FRLS) including PCC foundatoin suitable to accommodate the following as specified and as directed.:(a) MCCB 415 V,100 A, 4 pole with electronicreleaseElectronic Earth leakage module with over load , short circuit and earth fault protection with earth module breaking capacity 16 KA- 01 Nos.(b)Digital Panel Meter Multifunctional type for Amps, Volts, KWH, Power Factor and other parameters flush mounting with LED indication lamp complete and all as per standard pratice ---1 Job |
| 129 | Supply and fix foot valve of size 150 mm dia Complete all as specified and as directed. |
| 130 | Supply and fix 2 core 1.5 sqmm FRLS armoured copper cable as per IS:1554 in suitable dia steel conduit including all fixing accessories all as specified and directed. |
| 131 | Supply and fix inrepair Air release valve made from gun metalsingleair outlets confirming to IS of size 25 mm dia fixed on the top of downcomer pipe ofdia 100 mmincluding necessary slot making, welding , and making good the disturbed surface , applying two coats of synthetic enamal paint over a coat ofred oxide primer etc with complete all as specified and as directed. |
| 132 | Supply and fix24 V Electronic Hooter & making connection to the cable and making goodthe disturbed surfaces completeall as specifiedand directed. |
| 133 | Lightening Protection |
| 134 | M & Lforsub-main wiring with 1.5 sqmm nominal area one single core PVC insulated unshethed multi-stranded FRLS copper conductor cable including one 1.5 sqmmPVC insulated unshethed multi-stranded copper conductorcable for earth wiredrawn through 20 mm dia PVCconduit complete all as specified and as directed.Note :(i) Two runs of 1.5 Sqmm + one run of PVC conduitshall be measured as an one Unit. |
| 135 | PVC Conduit |
| 136 | Supply and fix telephone sockets (Jack type) RJ 11-1 with shutter 1 module with all accessories complete all as specified and directed. |
| 137 | Supply and fix TV co-axial socket 1 module with all accessories complete all as specified and directed. |
| 138 | CENTRAL AIR CONDITIONING |
| 139 | Supply,install, testingand commissioning ofLT Outdoor type panel board of suitable size, pedestal mounted, CPRI approved totally enclosed, dust and vermin proof, front side openable, type IP 54 protection made of CRCA sheet 3.15 mm thick of size as per IS and having proper locking arrangement in front and back side door suitable for 440 Volts, 50 Hz, 3 phase 4 wire system including cable glands of suitable size for incoming and outgoing cables and comprising with and including following accessories and mounted on PCC Platform min 35 cm from ground level andgrouted in PCC 1:3:6, 100 mm thick, 0.25 m all round the panel board complete with the following items housed in :-BUSBAR :- 600 Amps rated Alumuniumbus bar TPN duly insulated with coloured PVC sleeve as per standard colour code and rigidly mounted on bakelite / DMC insulatorbus bar support (Square / round) insulators of suitable size and good insulation resistance (Busbar to MCCB shall be connected through suitable size of aluminium rigid / flexible busbar).(a)Incomming :-(i) MCCB 400 Amps Microprocessor based released , 4 pole, 35 KA, 415 V- 01 Nos(iii)LED Multifunction with meters. - 01 No(iv)LED indicating lamps-1 [set of 3](v) MCB SP 06 Amps \"C\" curve-03 Nos(b)Outgoing :-(i)MCCB 63 Amps, 4 pole, 25 KA, 440Volts- 01 No (ii)MCCB 100 Amps thermal based , 4 pole, 25KA, 440 Volts- 09 Nos |
| 140 | Supply and HDPE double wall corrugated pipe of 90 mm outer dia for cable protection laid in trenches complete all as specified and directed. |
| 141 | Arboriculture |
| 142 | M&L for preparing the soil base for planting Bermuda grass by levelling the base to required slopes over spreading seeet earth to an average thickness of 200mm including mixing te natural fertilizers like cow dung, vermi complst etc : to imporve the fertility of the soil int he required roprotion and fianlly preparing the sil base suitable of Bermuda grass with maintenance for the period of one year complete all as specified and as directed. Note-(Supply and spreading of sweet earth and separently) Note- Rates to be deemed as inclusive of one year maintenance period. |
| 143 | Supply plantation and developing of Ficus Black (Ficus benjaminal) Height of plant not less than 1.00 mtr above ground level of age 6 months wit proprotional girth evergreen species including preparation of ground 0.60 mtr deep and of size 600x600mm and filling of good earth and compst and watering etc., complete all as specified and as directed |
| 144 | Supply and spreading sweet earth obtained from outside of MD and land from stone and pebbles (shall not exceeding 4.36mm) to an average thickness of 200mm suitable for giving sufficient strength to plantation complete all as specified and asdirected. |
| 145 | S &F 20mm dia brass water spinkler complete all as specified and as directed |
| 146 | Cooling Appliances |
| 147 | Supply and fix refrigerator electric driven [single phase] 240 litres capacity double door inverter type not less than 3 star rating, 240 Volts, 50 Hzcomplete all as specified and as directed |
| 148 | Supply and fix Voltage stabilizer for automatic operation, single phase naturally oil cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 with accuracy ± 2.5% and of capacity 2 KVA complete all as specified and as directed |
| 149 | Supply and fix Voltage stabilizer for automatic operation, single phase naturally oil cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 with accuracy ± 2.5% and of capacity 5 KVA complete all as specified and as directed |
| 150 | Mechanical laundry |
| 151 | Supply, install, testing andcommissioning of Washer Extractor (Front loading type) of capacity 60Kg, basket volume not less than 600 ltrs, G force not less than 320 GS, Steam heated, C.E. Certifiedmachine heavy duty, high spin soft mount, Front loading open pocket, Fully programmed microprocessor up to 30 customised Pre set programmes, top suspension with hydraulic cushion, full stain less steel cabinet, SS inner cylinder & outer drum and loading door, single motor variable frequency drive, 5 Compartment Soap dispenser complete all as specified and as directed |
| 152 | Supply, Install, testing and commissioning Drying Tumbler, Front loading, Basket volume not less than 200 ltrs not less than 60 KG capacity, steam heated, C.E Certified machine, open pocket, SS Inner cylinder, Reversible doubled walled outer drum, Auto digital Time & Temperature & Auto digital control for drying and Cool down Time, Separate Motors Drive & suction Blower complete all as specified and as directed. |
| 153 | Supply, Install, testing and commissioning of vaccum finishing table Rectangular table top with SS Heater, Size 1200mmx750mm [Minimum]Extended Exhaust duct with rack and tube light & with swivelling arm assembly for utility buck of size 800x300x200mm (minimum) along with Electric steam Iron and Teflon shoe complete all as specified and directed |
| 154 | Supply Install, testing and commissioning of flat work drying ironer, chest heated, front feed, rear return, pneumatic operated ironing chest, adjustabel ironing pressure, variable frequency inverter drive conveyor belt feed, perforated roller with centrifugal moisture suction galvanized springs with polyster padding, Roller size 530mm dia x 3000mm L minimum, C.E. Certified machine, steam heated, complete all as specified and directed |
| 155 | Supply, Install, testing & commissioning of Flat bed press pneumatically operated with front push buttons, Auto Digital Time release and Bed with centrifugal moisture suction, adjustable ironing pressure teflon line head, Head size 1500x750 mm (Minimum), Steam heated complete all as specified and directed |
| 156 | Supply, lnstall, testing commissioning of Dry cleaning machine, high spin, Soft mount, Multi solvent, Computer controlled, not less than 15 KG capacity, Basket volume not less than 150 ltrs, Front loading, open pocket, Minimum 16 pre set programme, top suspension with hydraulic Cushions, Single motor variable frequency drive, Two solvent tanks with twin pumps not less than 75% solvent recovery complete all as specified and directed |
| 157 | Supply,install, testing & commissioning of Stain removing spotting machine, Stainless steel large work station with SS swivelling sleeve arm, SS Rack for solvent container, Stainless steel spotting guns, heavy duty \"Steam-Air\" Cold & Hot spotting device for Pre & Post spotting, Ecological Chemical Suction and lighting device complete all as specified and directed |
| 158 | Supply Install, testing & comnissioning of Diesel fired Boiler of capacity 600 Kg, Non IBR HSD, 10.54 Kg/Sg cm, MS ducting for chimney including 2000 Itrs water storage capacitytank on 3 mtr high with supporting MS structure complete all as specified and directed |
| 159 | Supply, Install, teasting and comissioning of Air Compressor, 10 HP minimum fully automatic, double stage , tank capacity 500 litre and pressure 8 Kg/ Sq Cm, complete all as specified and directed |
| 160 | Supply only washing room trolley totally stainless steel outer & inner body over all size : 850x650x800 mm(Minimum) complete all as specified and directed |
| 161 | All as per item above but wetliner trolley |
| 162 | Supply, Install, testing & commissioning of Water softener plant of capacity 300 ltrs/hr Cation exchange ALI (for water hardness less than 500 ppm) including feed pump service tank of capacity 300 ltrs including necessary connections of inlet and outlet connection complete all as specified and directed |
| 163 | Suppy & fix Fuel tank 1000 Itrs capacity for diesel fired boiler fixing on raised MS structure and pipe line connection of MS pipe for provide of steam to machineries with all necessary fittings inchuding valves of various sizes complete all as specified and directed |
| 164 | Supply , install, testing and commissioning of indoor meter box panel board , CPRI Approved, IP 42made out of CRCA sheet 2 mm thick vermin proof factory madewith 40 x 40 x6 mm MS angle/channelduly painted with two coats of synthetic enamel powder coated paint over a coat of metal primer with bus bar chamber comrising of high conductivity copper bus bar of capacity 400 Amps three phase and half the capacity for neutral including internal wiring with 6 sqmm copper conductor (FRLS) including PCC foundation suitable to accommodate the following as specified and as directed.:(a) MCCB 415 V,200 A, 4 pole with electronicreleaseElectronic Earth leakage module with over load , short circuit and earth fault protection with earth module breaking capacity 25 KA- 01 Nos.(b)Digital Panel Meter Multifunctional type for Amps, Volts, KWH, Power Factor and other parameters flush mounting with LED indication lamp complete and all as per standard pratice ---1 Job |
| 165 | Suppy, install, testing and commissioning of centrifugalMonoblock pump set 7.5 KW/10 HP motor 3 phase 415 volts, 3000 RPM, body and impeller : cast iron, Shaft : SS and sealing : mechanical sealing complete all as specified and directed. |
| 166 | DG Set |
| 167 | Supply, install, testing and commissioningof silent Diesel Engine Generating set including accoustic enclosure as per latest CPCB norms 415 Volts 160 KVA, 3 Phase, 0.8 power factor, 50 Hz, 1500 RPM self excited self regulated brushless AC generator including accoustic enclosure suitable for ambient condition and conforming to condition under IS-4722, BS-5514/2613/5000 with AMF Panel and including the followingincluding accoustic enclosure suitable for ambient condition at sea area and conforming to Engine as per IS:10002, ISO-3046, BS-5514 and Alternator as per IS:4774, BS EN 60034-1 with the following accessories including necessary suitable size PCC foundation, GI pipe for laying of cables etc., all as per manufacturers instructions complete all as specified and directedMake: Kirloskar/ Cummins/Ashok Leyland/ Jyoti/ Crompton |
| 168 | (i) The capacity of generator set shall be net after all due de-rating factors as per relevant ISI design.(ii) Rate quoted shall be deemed to be inclusive of cable and terminations form generator to the AMF panel, with necessary holes to wall including making good to disturbed surfaces so as to match with the existing finishes all as specified and directed.(iii) The quoted rate shall be deemed to be inclusive of first fill of oil and final successful acceptance test.(A) Alternator: Standard design alternator rated at 160KVA net output at site after considering de-rating as per site conditions at 0.8 (Lag) power factor AC, 3 Phase, 4 wire, 415 Volts, 50 Hz, 1500 RPM, self excited self regulated screen protected drip proof IP 23 enclosure brushless design with winding in pole faces, insulating class \"H\" and voltage regulation of +/-1% at rated voltage from no load to full load.The alternator shall be conforming to BS 2613/5000 and shall be imposition to generate supply with frequency regulation with in +/-1% tolerance.The alternator will be suitable for tropical climate and shall generally conform to BS-2613/5000/IS-4722. |
| 169 | (i) Insulation class-\"H‘(ii) Temperature rise Class-\"H‘(iii) Excitation: Self Excited(iv) Regulation Performance: The voltage is kept constant with +/-1%, manual voltage adjustment within +/-5%(v) Frequency regulation +/-1%(B) Diesel Engine: Adequate capacity of Diesel engine as approved by the Accepting Officer based on manufacturers technical details water cooled to drive independently above alternator and after considering de-rating as per site conditions after generating and reducing power consumed by accessories directly coupled through flexible coupling multi cylinder multi stroke direct injection, cold starting 1500 RPM, as per relevant ISI/BS-5514 with an overload capacity of 10% for one hour in 12 hours continuous running complete with standard accessories all as specified and required for safe handling and operation salient features of accessories shall be as under: |
| 170 | (i) Fly wheel with housing(ii) Cooling System: Moulded radiator with fan & belts(iii) Cooling Water Pump: Centrifugal type belt driven(iv) Exhaust System: Exhaust System complete with exhaust piping of 150mm dia. with MS pipe light grade up to & outside and 1 meter away from the enclosure, covered with asbestos rope and aluminium foil of 28 SWG complete with in the enclosure for safe exhaust without transforming vibration to the wall of the enclosure.Exhaust gas turbo charger type.Exhaust manifoldSilencer: Residual type Bellows(v) Fuel System: Fuel injection system with fuel injectors, fuel injection solenoid switch controlled by electronic governor for 1% speed/ frequency regulation, Fuel filters, Fuel hoses.(vi) Lub oil System: Lubricating oil filter, Lubricating oil pump(vii) Air Intake System: Air intake Manifold, Air cleaner dry type(viii) Governor: Electronic Governor(ix) Starting System: Electric Self starter with maintenance free battery including battery charging alternator |
| 171 | (x) Batteries: Batteries of maintenance free of capacity as recommended by the manufacturer complete with copper conductor multi stranded leads of suitable length from self starter to the battery terminals complete with initial charge and initial fill of electrolyte all as specified and starter gear ring start and stop push button, Ignition key/switch.Handling and Operation: Salient features of accessories shall be as under:Radiator with blower fanCorrosion inhibitor coolantPaper element filters for fuel, lub oil and by passElectronic governor controlled direct fuel injection systemFly wheel housing and fly wheel(xi) Generator Monitoring Panel: Comprising of all standard items as mentioned under this schedule or as per standard practice ignition key switch and start/stop arrangement, indications for engine parameters, hour run meter, RPM meter, engine oil pressure indicator, water/coolant temperature indicator, battery volt display.(xii) Safety Controls: Engine low lube oil pressure high water temperature and over speeding of engine |
| 172 | (xiii) Coupling arrangement : Flexible coupling, fly wheel to suit flexible coupling(xiv) Accessories : AVM pads built or separtely mounted to manufacturer base frames.(xv) Base frame: Made out of ISMC 250 of sturdy design made of MS channel or as recommended by manufacturer.(C) AMF panel: Factory made indoor type control cubical made out of 2 mm thick CRCA sheet dust and vermin proof totally enclosed with front and rear opening of 415 Volts, 3 phase, 4 wire, AC, 50 Hz, including powder coated, aluminum bus bar of one and half times the rated load of 160 KVA alternator complete with internal wiring with PVC insulated single core copper conductor multi stranded wire of 1100 Volts grade of suitable capacity,fuses name plates consisting of 4 pole MCCB\"s and contactors and relays of capacity as recommended by the manufacturer, detachable cable gland plates all controls, indicators andMicro processor base LED/LCD display for indication voltage, current, frequency, speed, KW, KWH, PF, temperature,battery voltage,etc with the following:- |
| 173 | (i) indicator lamps - 3 Nos, (ii) Fuse set - 3 Nos (iii) Annuciation with indication lamps for :- (a) Low lub oil pressure (b) High water Temparature(c) Engine over speed (iv) Battery low voltage Controls :- (a) Load on Indication(b) Load off indication(c) Engine start push button (d) Engine stop push button(v) Fault accept/Reset push button(vi) Battary Charger : (a) Transformer (b) Rectifier (c) Resistance (d) DC Volt meter(e) Charger rate selector switch(D) Accoustic Enclosure : Manufactured by OEM suitable for 160 KVA DG Set(i) NAL approved as per CPCB(ii) It should be as per latest rules and regulations of Ministry of Environment and Forest and pollution control board |
| 174 | (iv) Fuel tank should be inside the enclosure and the capacity of the tank for 12 Hrs run the DG Set.(v) construction details/specification are as follows:(vi) Outer Body : CRCA sheet of 1.6 mm thick(vii) Doors CRCA sheet of 1.6 mm thick(viii) Sound insulation : As per OEM Norms.(ix) The accoustic should be composite in construction and fully assembled integral unit(x) The batteries should be placed inside the enclosure beside the DG set on a suitable insulated plat form(xi) The cost of the fuel pipe lines is deemed to be included in the quoted rate.(xii) The DG Set should be provided with externalEmergency stop push button(xiii) The enclosure should be suitably illluminatedby CFL/FTL/LED lamp fittings(xiv) The noise level should be 75 dB at 1m under freefield conditions |
| 175 | (xv) The acoustic enclosure parts shall be of powder coated after pre treatment process. The powder coating shade should be Gen set green.The base frame should be painted with epoxy based black shade(xvi) Rubber matting of LV grade 19 mm thick of suitable size, chequered type, ISI marked shall be laid in front of control panel.(E) Testing: The DG set shall be tested for a period Not less than 12 hours continuously out of which at least 1/2Hr on No Load and 02 hrs on 25% load, 02 hours each on 50% and 2.5 hrs on 75 % of rated full load, 4 hours on rated full load and 01 hours on 10% in exceess of rated full load.Necessary load shall be given on connected load. If the required full load for testing purpose is not available at the site, artificial load has to be arranged by the contractor for the testing. All instruments, consumable stores like engine oil, grease required for carrying out the tests including manpower shall be provided by the contractor. Contractor shall arrange DHPP for testing of DG set . Unit rate quoted shall deemed to include cost of the same. |
| 176 | LIFTS |
| 177 | Supply, install testing & commissioning of electrically operated passenger lift of capacity 20 Passenger (1360 Kgs capacity) in the adjusting lift well, 1.5 mtr/Sec speed with automatic micro stroke button control, micro processor based controller simplex selective/collective control suitable for 3 phase, 50 Hz 415 Volt AC supply independent operating with AC variable frequency (AC VVVF) control or closed loop with power saving regenerative drive) with suitable motor gear unit ground floor plus eighth upper floor i.e with 09 stops and 09 landing (G+8) with or without attendent suitable for synchronised operation automatic power operated centre opening (opening as per site requirement)sliding stainless steel door with mirror finish or 16 gauges with infra red sensors all along the height for car doors with automatic rescue/leveling device (ARD) (with +-5 mm) with suitable batteries, haul position digital indicators in car and all landing with call indicating lights etc including necessary housts and beams for mounting machine in the machine room including all civil works required in connection with erection of lifts complete all as specified. The lift shall be provided with and including the following :- |
| 178 | a) Fire man switch.(b) Automatic rescue device (ARD) during power failure including manual operation provision with suitable capacity or batteries designed for running the lift with full load.© Battery operated emergency light (LED Ceiling fitting) alarm ( speaker for emergency alarm system to be fixed) and stop button in car with rechargeable areangement for battery).(d) Suitable decorative ligting arrangement inside the lift(e) One sleek circular PVC heavy duty fan in false ceiling.(f) Aluminium chequred plate (3 mm thick) as flooring joint in chequred plate should not more than one and top covering with PVC flooring complete.(g) Non stop button/independent operation.(h) Over load warning indicator both audio and visual type with tripping system having relay etc.(j) Front landing door of stainless steel moon rock finish operations with a minimum time of 10 seconds and up to a maximum time of 30 seconds. |
| 179 | (k) Car size shall be conform to IS -3531-1976 and body to be stainless steel of 16 gauges moon rock finish with stainless steel hand rail 38 mm hairline finish.(l) Set of three in number limit switches at the bottom and top most position of lift hoist ways as specified in IS.(m) Mirror of 4 mm thickenss of suitable size as specified.(n) Opening with glass door of 5 mm thick 200 x 600 mm size in all the doors.(o) Specification plate with complete details.(p) Continuous earthing for machine and equipments.(q) Steel wire rope of adequate size as per relevent IS and as per manufacturer specifications.(r) Other standard fixtures and fittings like guide rail, sheaves counter weights with guards, buffer gear unit brakes, control panel, lock, governor, car operational panel, control and trailing cables complete.(s) Full length display indicator panel.(u) Suitable phase reversal relay shall be provided on the controller to protect lift /equipment against phase reverse, phase failure and low voltage. |
| 180 | (v) Stainless steel front opened landing door with small opening for vision of size 200mm x 800 mm with toughended glass not less than 08 mm thick.(w) Intercom be connected with nearest sucurity post. Note:a) Cost oflift inspector inspection is deemed to be inclded in the item rate. provision of one lamp holder, one socket with PVC box of sitable size to be provided at the top of lift for servicing.b) one lift of 13 passengers only has to be provide with all necessary facilities require for fire lift as per NBC -2016. |
| 181 | All as per item no 140 above but for good lift of capacity 2000 Kgs. |
| 182 | All as per item no 140 above but for passenger lift of capacity 20 passengersof capacity 1360 Kgs serving G+5 floors,, 06 landings. |
| 183 | High bay light |
| 184 | Supply and fix high efficieny round high bay lights 120 Watt in PDC housing & IP lenssuitable for industrial application, luminaire effeciency > 150Lm/wt, 10 KV SPD & ingress protection of IP 66 with additional safety chain complete all as specified and as directed |
| 185 | M & Lforsub-main wiring with 2.5 sqmm nominal area two single core PVC insulated unshethed multi-stranded FRLS copper conductor cable including one 2.5 sqmmPVC insulated unshethed multi-stranded copper conductorcable for earth wiredrawn through 20 mm dia PVCconduit complete all as specified and as directed.Note: (i) Two run of 2.5 Sqmm + one run of 2.5 Sqmm as a earth wire cable + one run of PVC conduitshall be measured as an one Unit. |
| 186 | S & F Cable PVC insulated LT 1100 V grade with copper conductor of size 3 core 2.5 Sqmm multi stranded conductor laid in ground fixed to wall roof etc with suitable calamps spacers bolts nuts etc complete all as specified and as directed |
| 187 | S & F Loop in loop out box of FRP made with IP 65 protection of thermoplastic circuit junction boxes of size 205 x 255 x 112 mm for cable entry and exit combi climate cable glands of IP 66/IP67 for cable entry and grommets IP 65 for conduit of cable exit with MCB SP 6 Amps, 10 KA, C curve over load and short circuit protection terminals as PVC connector heavy duty 32 Amps, 4 way for cable with necessary fixing arrangements an with cable glands, etc complete all as specified and as directed |
| 188 | Supply and fix time switches 250 Volts, single Phase, 20 Amps rating with contactor fitted inside steel enclosure complete all as specified and as directed |
| 189 | Electric chimney |
| 190 | Design, fabricate, Testing, commissioning of duct of size 1000mmx 1000mm made with stainless steel sheet 24 SWG SS sheet ducting angle frame threading rods, nuts bolts, along with damper suitable blower with starter and panelling for all items fixing outer SS sheet ducting box type bottom to top [Ist to 09th floor] for electric chimney complete all as specified and directed. |
| 191 | Supply and install, Testing, commissioning of 10HP blower with stater and installed in chimney single skin ceiling, 415 Volts, 50 cycles, 3 phase Ac supply damper at inlet complete all as specified and directed. |
| 192 | Supply and install, Testing, commissioning of SS exhaust hoof made with SS 22 SWG 60\"x30\"x20\" inch filter made with 22 SWG SS baffle washable grease filter and oil filter complete all as specified and directed. |
| 193 | Supply, lay and test cable, PVC insulated, sheathed LT 1100 Volts grade with copper conductor3 Core 10 Sqmm size laid in ground, fixed to wall roof with suitable clamps spacers complete all as specified and as directed. |
| 194 | STP |
| 195 | Design, Supply, Installation, Testing and Commissioning offully automatic suitable technology Sewage Treatment plant(STP) of package type 130 KLD as per geographic location,temperature differential and rainfall. The design of Plant can be either biological process or physical separation process with chemicals as secondary treatment process and must comply with the tertiary treated water parameter and also considering the following points while designing the STP: 1. Pre-Treatment are as follows : (a) Pre-treatment unit must consists of stilling chamber, screen, oil and grease trap, grit-removalchamber and equalization tank. (b) Stilling chamber must be designed to hold water for at least 60 seconds (c) The minimum width of the screens chamber should be 30 Cm. Material of (d) Medium/ coarse screen with mechanical/ manual cleaning to be provided. (e) Oil and grease trap and grit chamber must be combined for STPs of capacity less than 1 MLD. (f) Proper slopes towards one end must be provided for removal of sludge in all chambers with outfall for removal and disposal.2. No short-circuiting in all reactors of STP to be ensured3. Pumps to be provided in one working and one standby model.4. Free board of 500 mm to be provided in all process tanks. |
| 196 | 5. Aeration to be provided in adequate quantity where ever required to avoid septic conditions of waste water. Equalization tank/ collection tank and sludge holding tank must have aeration arrangements irrespective of type and process of treatment adopted6. Coarse diffused aerators must be provided for aeration. All pipes used for aeration purpose must be SS 316.7. The bottom of tank/ reactor, where provided, must be inclined towards one side to facilitate the removal of the sludge easily from the bottom. Outfall valves for all tanks to be provided accordingly. 8. Pumps/ inlet of pumps placed at bottom of the tanks should be placed such that pump capable to remove maximum possible water out of tank.9. The pre or post anoxic treatment must be based on the C/N ratio.10. Disinfection of the waste water to be provided at end of secondary treatment process.11. Tanks to be designed to hold waste water/ treated water at any process and to be utilized within 8 hours.12. No sludge drying beds to be used in design. Mechanical type sludge dewatering system to be incorporated in the design.13. Territary Treatment :(a) Tertiary treatment requirement will be based on the treatment methodology adopted in secondary treatment. Process meeting output waste water parameters given must not use tertiary treatment.(b) Tertiary treatment process must be designed to work at least 12 hours a day. |
| 197 | 14. The material used for constructin of sewer lines must comply with Para 3.12 of CPHEO maual. Any other better upgraded available material confirming to manual can be used.15. The construction material used for constructionof STP must comply with Para 5.3.15 to Para 5.3.18 of CPHEEO manual.16. Designs and construction methodology of brick/RCC manholes, lift wells and pumping stations are given at Chapter 3 and Chapter 4 of CPHEEO manual.For Physical Seperation Process :(a) The design should be able to meet parameters mentioned below.Parameters :- (A) Raw Sewage ParameterValueTemperature Ambient pH 6.5-8.5 TSS250-300 mg/L BODs at 20 C 200-300 mg/L COD 350-450 MG/L Oil grease 20-30 mg/LPhosphorus7.0 mg/L Nitrogen50 mg/L FC MPN very highColour and odourActual |
| 198 | (B) Treated Sewage ParameterValueTemperatureAmbient pH6.5-8.3TSS <10 mg/L BODs <10 mg/L COD<50mg/L Total Nitrogen10 mg/L Total Phosphorus1 mg/LFecal Coliform NilodourNo foul Odour |
| 199 | (b) The chemicals used for physical process must not inhibit the growth ofmicroorganism.(c) Design must cater to clear larger size inorganic material from the sewage.(d) Design for process of digestion of the sludge and final sludge disposal mechanism to be catered.(e) Method of treatment for reduction in Total Nitrogen, if high after physical separation, must be incorporated.(f) Footprint of the technology must be comparable to the biological treatment system.(g) Tertiary treatment to be carried out to achieve the perimeter mentioned in above Para. (h) Aeration is to be provided for the sewage stored for more than 30 minutes.(j) The system must be designed to work for 24 hours per day.(k) Odour control should be ensured.For Biological Seperation process:(a) Primary treatment to remove larger inorganic impurities along with oil and grease tank along with equalization tank of size not more than 35% of the total capacity of STP.(b) Biological process must be designed for 24 hours operational cycle.(c) Secondary treatment for reduction of BOD, COD, Total Nitrogen and Total phosphorus.(d) The treatment of sewage can be carried out in anaerobic conditions or aerobic conditions. In either case, due attention be given to odour control.(e) Biological treatment may be based on attached growth or suspended growth of micrOorganism. |
| 200 | (g) The SALR of the media used for suspended growth of bacteria must be at least be 500 M3/m2.(h) Virgin media must be used.(j) The percentage fill of media in suspended growth process must be between 10 to 40%.(k) The HRT in the biological process reactor/ tank must be between 1 to 4hours.(l) Aeration as per process requirement must be provided.(m) Any process using natural material like soil, silt, sand and gravel must be designed keeping in view of the footprint and treatment efficiency provided(n) Proper slopes towards one end must be provided for removal of sludge in all chambers with outfall either to equalization tank or sludge tank.(o) The treatment of sewage can be carried out in anaerobic conditions or aerobic conditions. In either case, due attention be given to odour control.(p) Tertiary treatment to be carried out to achieve the perimeter mentioned in above Para.(q) The process must be designed to operate uninterrupted round the clock without any break in operation.Automation and sample analyzers are to be made part of the process. (a) The system should provide following data on a central monitor:(b) All parameters mandated by NGT guidelines through online monitoring of influent (incoming) sewage when STP capacity beyond 1 MLD.(c)Cumulative sewage flow. |
| 201 | (d) All parameters mandated by NGT guidelines through online monitoring of treated wastewater (effluent).(e) Any event occurring not as per design to be highlighted onscreen.Accessibility of details on logging in remotely.(f) Cumulative treated wastewater flow.Note : The cost of Civil work i.e. RCC sumps etc is included in the quoted rate. |
| 202 | Supply and install All in one PC, window 11 Intel Processor N200 2.45 Inches, FHD, Intel UHD graphics, 8 GB DDr5, 512 GB SSD for SCADA system including keyboard , UPS mouse complete as directed |
| 203 | Pile Foundation |
| 204 | Boring for bored cast in situ piles 500 mm dia in any type of soil/clay/soft rock except hard rock/fractured rock and getting out and disposal of spoil out side MD land using HYDRAULIC RIG complete all as specified and directed. |
| 205 | Boring for bored cast in situ piles 500 mm dia in hard rock/fractured rock and getting out and disposal of spoil out side MD land using HYDRAULIC RIG complete all as specified and directed. |
| 206 | Carrying out Initial load [Compression] test on 500mm dia piles, complete all as specified and directed. |
| 207 | Carrying out Initial load [Lateral] test on 500mm dia piles, complete all as specified and directed. |
| 208 | Carrying out routine load test [Compression] on 500mm dia piles, complete all as specified and directed. |
| 209 | Carrying out routine load test [Lateral] on 500mm dia piles, complete all as specified and directed. |
| 210 | Carrying out low strain integrity test on 500mm dia piles including analysing the results complete all as specified and directed. |
| 211 | PHASE -IIMAINTENANCE OF ARBORICULTURE |
| 212 | Maintenance of all plants mentioned arboriculture schedule and BOQ for a period of onecomplete all as specified and directed. |
| 213 | PHASE -IIIOUTSOURCING OF PASSENGERS & GOODS LIFTS AS PROVIDED UNDER THIS CONTRACT AS PER SERIAL ITEM No. 140 to 142DURING FIRST YEAR OF DEFECT LIABILTY PERIOD. |
| 214 | Outsourcing of services for operaion of 06 x 20 Passenger [G+8], 02 x goods lift [G+8] and 02 x 20 Passenger lifts [G+5] floors, during First Year of the Defect Liability Period by providing services of Two Lift Operators (Semi Skilled) per Shift in 02 shifts on all the days including taking care of from any pilferage, theft or damage etc. to ensure smooth and trouble free operation of lifts to the entire satisfication of users/department including attending telephonic complaints, maintaining necessary records and documents etc. complete all as specified and as directed |
| 215 | PHASE -IV OUTSOURCING OF PASSENGERS & GOODS LIFTS AS PROVIDED UNDER THIS CONTRACT AS PER SERIAL ITEM No. 140 to 142 DURING SECOND YEAR OF DEFECT LIABILTY PERIOD. |
| 216 | Outsourcing of services for operaion of 06 x 20 Passenger [G+8], 02 x goods lift [G+8] and 02 x 20 Passenger lifts [G+5] , during second Year of the Defect Liability Period by providing services of Two Lift Operators (Semi Skilled) per Shift in 02 shifts on all the days including taking care of from any pilferage, theft or damage etc. to ensure smooth and trouble free operation of lifts to the entire satisfication of users/department including attending telephonic complaints, maintaining necessary records and documents etc. complete all as specified and as directed |
| 217 | PHASE -VOUTSOURCING OF PASSENGERS & GOODS LIFTS AND COMPREHENSIVE MAINTENANCE OF LIFTS AS PROVIDED UNDER THIS CONTRACT AS PER SERIAL ITEM No. 140 TO 142DURING FIRST YEAR AFTER EXPIRY OF DEFECT LIABILTY PERIOD. |
| 218 | Outsourcing of services for operaion of 06 x 20 Passenger [G+8], 02 x goods lift [G+8] and 02 x 20 Passenger lifts [G+5] , during first Year after expiry of Defect Liability Period by providing services of Two Lift Operators (Semi Skilled) per Shift in 02 shifts on all the days including taking care of from any pilferage, theft or damage etc. to ensure smooth and trouble free operation of lifts to the entire satisfication of users/department including attending telephonic complaints, maintaining necessary records and documents etc. complete all as specified and as directed |
| 219 | Comprehensive maintenance of Electrically Operated 20 passenger lifts (1360 Kgs)to serve G+8 upper floors all as mentioned vide SI No. 140 of BOQ during 1st year after expiry of defects liability period all as specified and directed |
| 220 | Comprehensive maintenance of Electrically Operated goods lifts (200 Kgs)to serve G+8 upper floors all as mentioned vide SI No. 141 of BOQ during 1st year after expiry of defects liability period all as specified and directed |
| 221 | Comprehensive maintenance of Electrically Operated 20 passenger lifts (1360 Kgs)to serve G+5 upper floors all as mentioned vide SI No. 142 of BOQ during 1st year after expiry of defects liability period all as specified and directed |
| 222 | PHASE -VIOUTSOURCING OF PASSENGERS & GOODS LIFTS AND COMPREHENSIVE MAINTENANCE OF LIFTS AS PROVIDED UNDER THIS CONTRACT AS PER SERIAL ITEM No. 140 TO 142 DURING SECOND YEAR AFTER EXPIRY OF DEFECT LIABILTY PERIOD. |
| 223 | Outsourcing of services for operaion of 06 x 20 Passenger [G+8], 02 x goods lift [G+8] and 02 x 20 Passenger lifts [G+5]floors, during second Year after expiry of Defect Liability Period by providing services of Two Lift Operators (Semi Skilled) per Shift in 02 shifts on all the days including taking care of from any pilferage, theft or damage etc. to ensure smooth and trouble free operation of lifts to the entire satisfication of users/department including attending telephonic complaints, maintaining necessary records and documents etc. complete all as specified and as directed |
| 224 | Comprehensive maintenance of Electrically Operated 20 passenger lifts (1360 Kgs)to serve G+8 upper floors all as mentioned vide SI No. 140 of BOQ during 2nd year after expiry of defects liability period all as specified and directed |
| 225 | Comprehensive maintenance of Electrically Operated goods lifts (200 Kgs)to serve G+8 upper floors all as mentioned vide SI No. 141 of BOQ during 2nd year after expiry of defects liability period all as specified and directed |
| 226 | Comprehensive maintenance of Electrically Operated 20 passenger lifts (1360 Kgs)to serve G+5 upper floors all as mentioned vide SI No. 142 of BOQ during 2nd year after expiry of defects liability period all as specified and directed |
| 227 | PHASE -VIIOUTSOURCING OF PASSENGERS & GOODS LIFTS AND COMPREHENSIVE MAINTENANCE OF LIFTS AS PROVIDED UNDER THIS CONTRACT AS PER SERIAL ITEM No. 140 TO 142 DURING THIRD YEAR AFTER EXPIRY OF DEFECT LIABILTY PERIOD. |
| 228 | Outsourcing of services for operaion of 06 x 20 Passenger [G+8], 02 x goods lift [G+8] and 02 x 20 Passenger lifts [G+5]floors, during third Year after expiry of Defect Liability Period by providing services of Two Lift Operators (Semi Skilled) per Shift in 02 shifts on all the days including taking care of from any pilferage, theft or damage etc. to ensure smooth and trouble free operation of lifts to the entire satisfication of users/department including attending telephonic complaints, maintaining necessary records and documents etc. complete all as specified and as directed |
| 229 | Comprehensive maintenance of Electrically Operated 20 passenger lifts (1360 Kgs)to serve G+8 upper floors all as mentioned vide SI No. 140 of BOQ during 3rd year after expiry of defects liability period all as specified and directed |
| 230 | Comprehensive maintenance of Electrically Operated goods lifts (200 Kgs)to serve G+8 upper floors all as mentioned vide SI No. 141 of BOQ during 3rd year after expiry of defects liability period all as specified and directed |
| 231 | Comprehensive maintenance of Electrically Operated 20 passenger lifts (1360 Kgs)to serve G+5 upper floors all as mentioned vide SI No. 142 of BOQ during 3rd year after expiry of defects liability period all as specified and directed |
| 232 | Notes for Outsourcing Services Items:(i) The lift shall be operated daily in two shifts as directed by the Engineer-in-Charge.(ii) The timings for two shifts of 8 hours each daily i.e. First shift shall be from 0600 hours to 1400 Hours and Second Shift shall be from 1400 Hours to 2200 Hours.(iii) In case of non-function of passenger lift, the Goods Lift installed in the same building shall be operated as directed.(iv) The work shall be supervised by adequately qualified supervisor with relevant experience of minimum 5 years items under BoQ shall be deemed to be including the same.(v) The unit rate is deemed to include for maintaining log books, record of repair/replacement of perished/unserviceable, minor adjustments, minor repairs of all accessories, cleaning/up keeping of lift and surrounding area as directed by the Engineer-in-Charge.(vi) One emergency light and necessary tools shall be available in a tool box with the operator in the shift for smooth functioning of lifts.(vii) Conveyance and communication system like mobile phone etc. shall be provided by the Bidders/Service providers to all Lift Attendants/Supervisors.(viii) The Bidders shall ensure house keeping, environmental cleanliness of area all round the lift and the area shall be kept absolutely neat and clean. The lift attendant shall clean the Lift car cabin, all landing floors and tiles all round lift doors with necessary cleaning material such as cotton cloth and cleaning solution etc. |
| 233 | (ix) The Bidders shall abide by the latest Labour rules and minimum wages Act. Wages paid by the bidders to the persons employed shall not be less than the minimum wages fixed by the state/central government from time to time whichever is higher. The Bidders shall also insure the workmen employed on the job.(x) The Bidders is responsible for insurance, EPF, ESI, Bonus, Labour welfare cess et., as applicable and shall be paid to the workmen as per existing Labour rules/ Acts/ regulations and rate quoted shall be deemed to be included for the same.(xi) Dress Code: The bidders shall provide the workmen with Dark Blue Colour uniform {formal pant & T-shirt} with labels showing/ printed i.e. “Name of the firm and designation” on front and on the back of the T-shirt along with protective clothing/gear. The bidders shall also provide shoes to the workers and the persons shall not be allowed to enter the work site without wearing shoes.(xii) INSURANCE: The Bidders shall be responsible for all Accidents/ Injuries happening to the workmen. Any accident causing minor/ fatal injury, partial disability due to any untoward incident or non-adherence to safety and IE regulations or fault in maintaining of internal electric supply system or on account of any mishandling/ wrong operation/ lack of knowledge of safety precautions or on |
| 234 | account of any circumstances beyond his/ their control, the bidders shall be solely responsible for settling all claims of compensation to the deceased, falling which department will have a right to recover any sum indicated/ claimed by Labour commissioner/court authorities. No claim whatsoever will be entertained in this regard. No compensation is payable by the department on this account. Bidders shall provide first aid boxes to meet any emergency situations.(xiii) The rate quoted by the bidders shall be deemed to be including Basic rate (Minimum Wages as notified by Government of India/ State Government/ Local body, whichever is higher), employers contribution towards Employees Provident Fund (EPF) liability, contribution towards Employees State Insurance Corporation (ESIC), contribution towards Bonus. Overhead and profit and labour welfare cess (LWC) as applicable depending upon the manpower requirement. This will create onus on the Bidders to applicable depending upon the man power requirement. This will create onus on the bidders to ascertain the relevant rates and quote accordingly. The rates quoted shall be inclusive of all taxes, cess, levies are applicable including GST. Note: The Manpower deployed shall be changed for every 11 months period. The rate quoted deemed to be inclusive for the same. |
| 235 | Notes for Comprehensive Maintenance Items:(i) Comprehensive maintenance consists of preventive and breakdown services including replacement of material and labour for major/minor spare parts and consumables like topping of Oils /grease/door rollers/ relays/ door belts/ gate lock contacts and hardware like bolts and nuts including load testing of lift for satisfactory performance once in a year complete and rate quoted by the tenderer includes for the above Lifts.(ii) Preventive maintenance consists of carrying out routine check by skilled personnel as specified in Particular specifications and as directed by Engineer-in-Charge and lubricating to all moving parts, topping parts, topping up of oils as per Lubrication Chart including Material and labour for all consumable and major/minor spare parts.(iii)Breakdown maintenance consists of attending to the faults that may occur and carrying out necessary repairs to electrical, control circuits and mechanical components including materials & labour for all minor & major spare parts and consumables of the lift that may occur during the operation.(iv) Fortnightly, quarterly maintenance registers shall be maintained and signed by the site engineer and contractor. |
| 236 | (v) Load testing shall be arranged by the contractor to the Lift for which repairs were carried out as and when directed by Engineer-in-Charge. (Once in a year with a validity of one Year/ Twice in a year with a validity of 06 Months)(vi) All maintenance works shall be carried out by well qualified tradesmen and supervisor of OEM.(vii) The quoted rate shall be deemed to be included the above aspect and for consumables such as timely toping up oils, acrylic covers, fuses, grease, waste cotton, stationery and other miscellaneous items and all minor & major spare parts.(viii) The tenderer shall submit MoU from the original manufacturer of the lift for comprehensive maintenance to undertake comprehensive maintenance during and after Defects Liability Period directly or through their nearest authorized/accredited agencies service personnel.The MoU shall be submitted at least 06 months prior to issue of completion certificate of main contract as per Work Order No I. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail