| 1 | Excavating in trenches, n exc 1.5m wide and n exc 1.5m in depth; for foundation, etc, n. exc 10 sqm on plan and n exc 1.5m in depth and getting out in soft/loose soil, complete all as specified and directed. |
| 2 | M & L for plain Cement concrete 1:4:8 type D2 using 40mm graded stone agg as in foundations, filling and mass-concrete, complete all as specified and directed. |
| 3 | M & L brick work with sub class \"B\" bricks (old size bricks) straight or curved on plan exc 6 m mean radius built in cm 1 : 6 with and including weep holes in brick work, completeall as specified and directed. |
| 4 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25cmthick with soil/loose soil, complete all as specified and directed. |
| 5 | Removing excavated material to a distance n exc. 50m and depositing where directed at a level n exc. 1.5m above the starting point, complete all as specified and directed. |
| 6 | M&L for rendering 15 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4 mixed with water proofing compound @ 3 % by weight of cement, finished even and smooth without using extra cement, complete all as specified and directed by the Engineer in Charge.Note - WPC shall be measured & paid separately. |
| 7 | M&L for providing cement concrete 1:2:4, type B1, using 20 mm graded stone aggregates as in coping including necessary form work complete all as specified and directed. |
| 8 | M&L for PCC 1:2:4 type B2 (using 20mm graded stone aggregate) as in surface channels and drains & benching of manholes and finishing even and smooth with out using extra cement, complete all as specified and directed. |
| 9 | M&L for forming fair finished drain or channel 50 cm in girth using extra cement including forms, moulds, mitred/stopped ends etc., complete all as specified and directed. |
| 10 | M&L for pre-cast reinforcement cement concrete (1:2:4) Type B-1, using 20 mm graded stone aggregate as in cover slab for manholes etc.and set in cm 1:6, inclding form work, complete all as specified and directed. |
| 11 | M&L for mild steel TMT Bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping of columns, hooking ends and binding with the including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and directed. |
| 12 | Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, in soft/loose soil, complete all as specified and directed. |
| 13 | S&F structural steel work as in roof trusses (framed), trussed purlins, crane gantries, rails and fastenings and heavy bracket framing( Beam, tee, angle, channel or flat sections) including distance pieces, cleats etcof Fe 410 -W (Gde - E 250 quality A), complete all as specified and directed. |
| 14 | S & FPlates (plain or chequered) channels,Fe 410-W(GdeE- 250) squarecutor notched (ordinaryand countersunk) forming holes, without any attachment, complete all as specified and directed. |
| 15 | S&F mild steel work as in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubesconforming to I.S 1161-1979 grade St-240, complete all as specified and directed. |
| 16 | S&F Pre-painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50 mm thick of approved colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws, complete all as specified and directed. |
| 17 | S&F Pre-painted galvatume aluminum zinc coating GI based plain steel sheet 0.50 mm thick of approved colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws , complete all as specified and directed. |
| 18 | M&L for Preparation of new steel surfaces and applying two coats of synthetic enamelled paint over a coat of red oxide primer, complete all as specified and directed. |
| 19 | Formwork to sides to concrete foundations, footings, base of columns, raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter fair finished surfaces of concrete etc, complete all as specified and directed. |
| 20 | Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc.rough finished, complete all as specified and directed. |
| 21 | Formwork to sides of pillars, posts, struts, piers, columns and stanchions, complete all as specified and directed. |
| 22 | Formwork to soffits of suspended slabs such as flat roof slabs, floor slabs, landings and similar work, not exceeding 200mm thick rough finished (Horizontal or sloping), complete all as specified and directed. |
| 23 | Formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide and for rough finished surface of concrete, complete all as specified and directed. |
| 24 | M&L for RCC Design Mix M-25, for Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete, complete all as specified and directed. |
| 25 | M&L for RCC Design Mix M-25, as in Columns, pillars, piers, posts and struts, complete all as specified and directed. |
| 26 | M&L for RCC Design Mix M-25, as in Beams, cantilevers, bressummers, lintels over 1.5m span, complete all as specified and directed. |
| 27 | M&L for RCC Design Mix M-25, as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like, complete all as specified and directed. |
| 28 | M&L for reinforcement TMT bars 5 mm dia and over up to and including 10mm diain stirrups, spacers and binders, cut to length, bent to shape required, including cranking, bending spirally or hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia or securing with clips, complete all as specified and directed. |
| 29 | M&L for rendering 15 mm thick in cement mortar 1:6, over brick or concrete surfaces, finished even and smooth without using extra cement, complete all as specified and directed. |
| 30 | M&L for rendering 5 mm thick on fair faces over concrete surfaces of ceiling, in cement mortar 1:3 finished fair and even without using extra cement, complete all as specified and directed. |
| 31 | Supply only integral water proofing compound conforming to IS-2645-1975, complete all as specified and directed. |
| 32 | M&L for preparing surfaces plastered or unplastered new surfaces with Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm), complete all as specified and directed. |
| 33 | M&L for providing PVDF aluminium composite panels with fire resistent mineral filled core material as ininterior/exterior wall cladding on external wall surface shall consist of following (i) Aluminium sheet making a total panel thickness of 3 mm with outer surface finished with PVDF based coating 0.25mm, inner surface finished with a thin coat of polyster paint. The cleness of aluminium cover sheet shall be 0.50 mm inner core shall be of LDPE(ii) Mild steel framing of section 25 mmx50 mm x1.50mm thick.(iii)MS grid shall not be exceed 1.0 sqm eachthe MS grid not more than 1 m c/c and shall be fixed with MS angle 30x30x5 mm projected 150mm from surface of wall, (iv)Colour shall be approved by GE. (v)Joint shall be sealed with silicon weater proof sealing compound with help of masking Tapes.Note : Canopy, borders, projections etc will be measured in sqm for payment purpose. |
| 34 | S&F 300mm size stainless steel letters, in Hindi / English and fix with stainless steel screws, complete all as specified and directed. |
| 35 | M&L for 15 mm thick Screed bed in cement mortar 1:3 mixed with integral water proofing compound @ 3% by weight of cement, complete all as specified and directed.Note: Supply only integral water proofing compound shall be measured and paid separately. |
| 36 | M&L for laying APP modified membarane with non woven polyester reinforcement mat (concrete core) not less than 3 mm thick & not less than 3.5 kg /sqm, the over the lap otching shall be 100 mm on length side & 100 mm on widthe sideover a tack coat of Industrial bitumen of 1.20 kg / Sqm over Bituminious based primer IS No. 3383@ 250 gms/sqm including apply of Aluminium colour synthetic enamel paint @ 200 gms/sqm all as per manufacture\"s instructioncomplete all as specified and directed. Note: Supply only integral water proofing compound shall be measured and paid separately. |
| 37 | M&L for framed work as in steel gate incl drilled for fixing of steel sheeting and to be prepared for hanging or sliding incl either hooks or hinges exclusive of steel sheeting, complete all as specified and directed. |
| 38 | M&L for bands, straps supports or stays for pintle hinges, hand made sliding bolts, clamp fasts, articles conforming to Fe 290, grade E-165, complete all as specified and directed. |
| 39 | M&L for cement concrete type C2 1:3:6 (40 mm graded stone agg) as in posts, complete all as specified and directed. |
| 40 | S&F, Fe 410-W(GdeE- 250) quality, Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and incl locking arrangement; also fastening and fixing, complete all as specified and directed. |
| 41 | S&F, 3.80 mm dia galvanised steel wire, 50x50 mm mesh, made up into mattresses or cages, lapped, wired and laid in position, including closing after filling, complete all as specified and directed. |
| 42 | S&F for window awnings (Rain canopy fabric material mentioned as per below) to be sixed with screws and washers to existing awning frames on windows all as specified and directed by Engr-in-Charge.Materials :(a) Febric of Dickson (Made in France) (b) Febric type acrylic (c) Febric colour Block Red (d) Febric installation with screw and washer (e) PVC binding off white colourWarranty :(a) Febric warranty 10 Years (b) Febric stitching warranty 3 years |
| 43 | S&F for powder coated aluminium frames for doors, windows, ventilators & awning with one or more rebates including jointing cleat for fixing and suitable arrangements/fittings for awnings including fixing to walls with suitable screws/ fasteners etc., complete all as specified and directed. |
| 44 | Demolition of Reinforced Cement Concrete of any description and in any position not otherwise specifically provided for, complete all as specified and directed. |
| 45 | M&L for RCC 1:2:4 type B0 (using of 12.5 mm Stone Aggregate) Slabs supported on walls, beams and columns in floors, roofs, landings, blaconies, canopies, deck slabs and in shelves and chajjas, complete all as specified and directed. |
| 46 | Taking down cement plaster from brick or stone masonry or concrete surfaces and hacking for key and scrubbing down with water etc., complete all as specified and directed. |
| 47 | M&L for preparation of new plastered surface and applying two coat of oil bound distemper over and including 3mm thick wall care putty wall surfaces, complete all as specified and as directed by Engr-in-Charge. |
| 48 | Demolition of brick work built in cement mortar of any description, complete all as specified and directed. |
| 49 | M&L for brick work with sub class \"B\" Bricks straight or curved on plan exceeding 6m mean radius built in cement mortar 1:4 as in manholes and drain, complete all as specified and directed. |
| 50 | M&L for granite (of any type) tiles 18-20mm thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixure of pigment to match the shade of granite stone including cutting and polishing types and including 20mm thick screed bed in CM 1:4, complete all as specified and directed. |
| 51 | M&L for first quality glazed ceramic coloured tiles of size (300x600mm) x 7mm thick, (shade and as approved by GE) laid on vertical surfaces such as skirting, dados and risers to steps etc. laid over and including 10 mm thick cement plaster in CM (1:4) set and jointed in neat cement paste ofhoney like consistancy and pointed in white or coloured cement to match the shade of tiles, complete all as specified and directed. |
| 52 | M&L for non skid ceramic coloured tiles, 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 Sq.m but not exceeding 0.18 Sq.m, laid in floors with neat cement slurry over and including 15 mm thick screed bed in cement mortar (1:6) including pointing in white cement with pigment to match the shade of tiles, complete all as specified and directed. |
| 53 | Taking up or down steel water tubing and connection incl cleaning for refixing or removal to stores for following bore:- |
| 54 | All as per item No 53 above 15 mm bore. |
| 55 | All as per item No 53 above 20 mm bore. |
| 56 | S&F for GI tubes medium grade with all fitting and fixed concealed complete to walls and ceiling or laid in floor in following bore of tube :- |
| 57 | All as per item No 56 above 15mm bore. |
| 58 | All as per item No 56 above20mm bore. |
| 59 | S&F for 20 mm Gun-metal, globe or gate valve, with iron wheel head, screwed both ends for iron pipe and fixed in repair and all as specified and directed. |
| 60 | S&F for sinks made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe, waste pipe with CP coupling, overall size 495mm x 420mm bowl size 410mm x 330mm x 160mm, complete all as specified and directed. |
| 61 | S&F for chromium plated, swan neck sink mixer, fancy type, suitable for sink, complete all as specified and directed. |