| 1 | Surface dressing n.exc 15cm deep in soft/loose soil etc complete all as directed. |
| 2 | Excavation in trenches n exc 1.5 m wide and n exc 1.5m in depth for foundation,etc or for shafts, wells ,cesspits, manholes pierholes etc n exc 1.5m in depth and getting out in Hard/Dense Soil complete all as specified and directed |
| 3 | M&L PCC 1:4:8 type D2 using 40mm graded stone aggregate as in foundation filling complete all as specified and directed |
| 4 | M&L for RCC- M- 30 Design Mix as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete all as specified and directed |
| 5 | M&L for RCC- M -30 Design Mix as in beams, cantilevers,bressummers, lintels over 1.5m span etc complete all as specified and asdirected |
| 6 | M&L for RCC- M -30 Design Mix as in columns, pillars, piers,posts and struts etc complete all as specified and as directed |
| 7 | M&L for RCC- M -30 Design Mix as in deck slabs and in shelves and the like etc complete all as specified and as directed |
| 8 | M&L for RCC- M -30 Design Mix as chajjas etc complete all as specified and as directed |
| 9 | Returning, filling including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and directed |
| 10 | Removing excavated soil to a distance n.exc 50 m and depositing as directed |
| 11 | Use and waste of form work to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter for fair finished surfaces complete all as specified and directed |
| 12 | M & L for Use and waste of form work to sides of pillars, posts, struts, piers, columnsand stanchionscomplete all as specified and directed |
| 13 | Use and waste of form work to sides and sofit of Beams for Fair finished surfaces complete all as specified and directed |
| 14 | Use and waste of form work to sides and sofit of Slab etc for Fair finished surfaces complete all as specified and directed |
| 15 | Use and waste of form work to sides and sofit of chajjas etc for Fair finished surfaces complete all as specified and directed |
| 16 | M&L Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips |
| 17 | M&L Mild steelTMT bars 6 mm to 8mm dia cut to length bent to shaperequiredand binding with mild steel wire annealed not less than 0.9 mm dia complete all as specified and directed |
| 18 | M&L for Ditto, but 5mm dia and over up to and including 10mm dia as in stirrups, spacers, binders and the like complete all as specified and directed |
| 19 | M&L Precast Cement Concrete Block Masonry with Solid Block, exc 10cm in width in type C-1, 1:3:6 (using 20mm graded stone aggregate) set in CM (1:6) all as specified. |
| 20 | M&LRendering 10mm thick on concrete surfacesin CM (1:6) finished even & smooth without using extra cement. |
| 21 | M&L Rendering 5mm thick in CM 1:3 on soffits of RCC slabs, roof projections, soffits and sides of RCC beams, waist slab, Loft Slab, RCC shelves, Chajjas, and the like finished even and smooth without using extra cement. |
| 22 | M&L 15mm thick rendering in two layers of 10mm thick backing coat in CM 1:6 and 5mm thick floating coat in CM 1:4 mixed with water proofing compound on all external wall surfaces finished even and smooth without using extra cement. (Note : Water proofing compound shall be measured and paid seperately) |
| 23 | Supply only integral WPC (3% by wt of cement). |
| 24 | M&L preparation of newly plastered surfaces of walland applying two coats of Oil Bound distemper over a coat of primer over a coat of internal wall care putty as specified and directed. |
| 25 | All as item 24 above but on Ceiling surfaces |
| 26 | M& L for Finishing walls with Acrylic smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) etc complete all as specified and as directed by Engineer-in-Charge.(Make Apex Ultima) |
| 27 | M&L for hardcore of broken stone or boulders of gauge n.exc. 63mm deposited spread and levelled in layers n.exc. 15 cm thick watered and rolled/ rammed to a true surfce. |
| 28 | M&L PCC 1:4:8 type D-2 using 40 mm graded stone aggregate in 75mm thick as in sub base complete all as specified and directed |
| 29 | M&L PCC 1:3:6 type C1 using 20mm graded aggregate of 75 mm thick as in Plinth Protection complete all as specified and directed |
| 30 | M&L Coloured Non-Skid Ceramic tiles 7 to 8mm thick (square/rectangular) area of each tiles exceeding 0.18 Sqm but not exceeding 0.38 Sqm in floor etc,set and jointed in neat cement sluryy and pointed in coloured cement to match as in floor over 15mm thick screed bed in CM (1:6) all as specified. |
| 31 | All as per item No 30 above but in skirting over 10mm thick back coat rendering in CM 1:4 |
| 32 | M&L chequered cement concrete tiles, with grey cement and pigment 30cm x 30cm x 20mm thick set, jointed and pointed in neat cement slurrry in floors including 15mm thick screed bed in Cm 1:6 all as specified and directed. |
| 33 | S&F anodised aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified and as directed |
| 34 | S&F anodised aluminium door shutters, aluminium section weighing 0.55 kg/m with and including necessary joining cleats, glazing clips, ruber neoprene packing, anodised aluminum snap beading screws, anodised aluminium fittings such as suitable handles (2 Nos), hinges (03Nos), etc. complete all as specified and as directed. |
| 35 | S&F anodised aluminium window and ventilator shutters, side/top hung type without sash bars, aluminium sections weighing 0.55 kg/m with and including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.). hinges type B-21 100mm long (2 no.) suitable handle (2 no.) complete all as specified and as directed. |
| 36 | S&F anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer in-charge. |
| 37 | Supply only 12 mm thick Prelaminated particle board, exterior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination and fixed to aluminium frames complete all as specified and as directed by Engineer -in-Charge. |
| 38 | Supply only 4.0mm thick sheet glass, ordinary quality in squares n exc 0.50 sq.m in each pane. |
| 39 | S&F Aluminium alloy anodised sliding door bolt with hasp, staple (bolt type) 300 mm long and fixing clips to sheet cast or extruded sections and fixing bolt or cast aluminium alloy complete all as specified. |
| 40 | S&F Aluminium anodised barrel tower bolt of extruded section of size 150mm long complete all as specified. |
| 41 | S&F Aluminium anodised barrel tower bolt of extruded section of size 100mm long complete all as specified. |
| 42 | S&F Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161-1979 grade St.-240 |
| 43 | S&F for Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, with riveted, bolted or welded attachment conforming to Fe-410-W grade E 251 Quality B complete all as specified and directed. |
| 44 | S&F mild steel bolts of diameter of neck exc 12mm and n.exc 20mm, purpose made with hexagonal or square head one end and screwed the other, or screwed both ends; each screwed end to be fitted with washers and one hexagonal or square nut n exc 30cm long as specified. |
| 45 | S&F Pre-painted galvalume aluminium zinc coating GI based corrugated sheet 0.50mm thick as per approved profile, coloured, having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws all as specified |
| 46 | S&F 0.56mm Plain, Aluminium sheeting, Alloy 31000 H4 in ridges, hips, valley gutter, drip and straight flashing (length and girth as fixed) etc complete all as specified and as directed. |
| 47 | S&F MS works as in wind ties for roof incl securing bolts etc complete all as specified and as directed. |
| 48 | Preparation of new or previously untreated steel surfaces & applying a two coats of synthetic enamel paint over a coat of red oxide primer over 10cm in width or girth,not otherwise described. |
| 49 | M&L Painting to new steel and iron surfaces of n exc 10cm wide or girth by two coats of synthetic enamel paints over a coat of red oxide primer including preparation complete all as specified and as directed. |
| 50 | S&F Gl frame work for seamless ceiling comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steelexpansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre with and including hangers 6 mm dia. G.I. (upto1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long etc complete all as specified |
| 51 | M&L for providing and fixing Gypsum board 12mm thick in ceiling having PVC paper on front side and metalised polyster layer on the back side suitable placed in existing false ceiling grid made of aluminium/GI/MSfixed with screws as per manufacturers instruction etc complete all as specified and directed. |
| 52 | S&F Informatory reflective direction and place identification sign board with double post stainless steel pipe frame on made out of 2 mm thick aluminium sheet, face to be fully covered with high intensity encapsulated lens type retro -reflective sheeting as approved by Engineer-in-charge.Letter, symbols, borders etc. will be as per IRC - 67 with required colour scheme on the boards and with the high intensity grade complete all as specified and as directed. |
| 53 | S&F Stainless steel post of 60mm dia and 16 gauze duly polished for best shine fitted with round globe on topas in sign board frame including embedded in concrete , excavation, returning filling & removal work andcompleteand specified as per manufacturers instructions. |
| 54 | M&L Point wiring complete with 1.5 sqmm single core FRLS PVC insulated andunsheathed cable 1100 volts grade with multistranded copper conductor drawn through and including concealed PVC conduit and all accessories fixed to walls / roofs / floors / ceiling etc. and including provision of 1.5 sqmm copper cable green in colour as earth continuity conductor and connected to common earth dolly, including fabricated steel terminal box made out of 1.60mm thick MS sheet concealed in walls, with 3mm thick laminated sheet top cover for housing the switches, socket outlets,fan regulators etc. all as specified and as directed forthe following:- |
| 55 | One light point controlled by one switch |
| 56 | One exhaust fan point controlled by one switch |
| 57 | One fan point controlled by one switch and one regulator |
| 58 | One 3 pin switch socket outlet point 5 amps on same board with other switches |
| 59 | One 3 pin switch socket outlet point 5 amps on independent board |
| 60 | All as per item No 54 here-in-before but for 3 pin 15 Amps switch socket combination on independent board with 4 sq mm copper cable and provision of 4 sq mm FRLS PVC insulated stranded copper conductor cable for earth continuity conductor connected to common earth dolly connecting upto fittings complete all as specified and as directed. |
| 61 | Supply and fixing Modular switch 1 way 5 A, 1 module all as specified and directed. |
| 62 | Supply and fixing Modular switch 1 way 15 A, 1 module all as specified and directed. |
| 63 | Supply and fixing modular socket outlet, 2/3 pin combined , 6/16 Amps, combined 2 module, 230 volts all as specified and directed. |
| 64 | Supply and fixing modular socket outlet, 2/3 pin combined , 6 Amps, combined 2 module, 230 volts all as specified and directed. |
| 65 | S & Fmodular white cover plate with frame, 3 module all as specified and directed. |
| 66 | S & Fmodular white cover plate with frame, 6 module all as specified and directed. |
| 67 | Supply and fixing modular fan step regulator, 230 V, AC, 120W - 2 module complete all as specified. |
| 68 | Supply and fix ceiling rose surface bakelite 65x50mm 3 terminal complete all as specified and as directed. |
| 69 | Supply and fix ceiling fan suitable for working on AC 230 volts, 50 Hz,1200 mm sweep 5 star rating with down rod and canopy colour of milky white including suitable fan hook anchor fastner for fixing of fan on ceiling complete all as specified and as directed. |
| 70 | Supply and fix exhaust fan suitable for on working of AC 230 V, 50 HZ 380 mm sweep heavy duty , with metal body complete all as specified and as directed. |
| 71 | Supply and fix metal enclosure distribution board SPN, 8 way 240 volts, with 200 amps rated bus bar, double door suitable for mounting MCBs including taking down old MCB/DB complete all as specified and directed.Note-: Incoming & outgoing connections from the DB shall be provided with proper lugs/ thimbles etc |
| 72 | Supply and fixMCB single pole240 volts, 6 to 32 amps \"C\" series complete all as specified and as directed by Engineer-in-Charge |
| 73 | Supply and fix single pole and netural 240 Volts 32 amps complete all as specified and as directed by Engineer-in-Charge |
| 74 | Supply and fixing aluminium housing LED batten 22Watt mounted battenfitting 4 ft in length nano diffuser technology to ensure minimum loss in light transmitted, long life of over 30000 hours includinglamp and connecting with twin core shethed cable from fitting to ceiling rose all as specified and as diected. |
| 75 | S&F 35 W LED street light fitting 230 V AC outdoor type with pressure dia cast aluminium IP65 road way luminaire with high power LEDs as light and electronic driver complete with necessary brackets (made out of 25/32 mm bore GI light grade pipe approx. 0.6 M long) nuts, bolts etc to be fixed as on walls complete as directed. |
| 76 | M&L for earthing complete with galvanised steel earth plate electrode 60 x 60 cm x 6mm thick buried directly in ground (earth pit not less than 2.25 M deep below ground level) with top edge of the plate not less thab 1.5 Meter below normal ground level connected to GI wire 4 mm dia by means of bolts, nuts , check nuts and washers of GI and GI tubing 20 mm bore light grade for earth lead protection up to main earth test point and including concrete pit in PCC (1:3:6) type C1 pre cast RCC (1:2:4) type B1 cover slab 54 x 54 x 5 cm with one handle for lifting made out of 8 mm dia MS bar, wire mesh, 20 mm bore GI tubing (LG) for watering, charcoal or coal and salt in alternate layers including excavation earth work complete all as specified and directed electrical plate No. 3 of SSR part - I |
| 77 | supply & LayXLPEinsulated,heavy duty 1100 volt grade electricarmoured LT UG cable with aluminium conductorof size 10 Sqmm 2 Core in trenches/along the wall/including making all connections, saddles, spacers including scaffolding if any required for saddling the cable in walls of building of height up to 25 meter, complete with aluminium lugs as required at site and as directed by Engr-in-Charge |
| 78 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sqm on plan and n exc 1.5 m in depth and getting out Soft/loose Soil |
| 79 | Returning, filling in, including spreading, leveling watering and well ramming in layers not exceeding 25cmsoil / hard dense soil. |
| 80 | Removing excavated material not exceeding 50m and depositing where directed at a level not exceeding 1.5 m above the starting point.Soft Soil / hard dense soil |
| 81 | Supply & lay cable protection pipe of HDPE double wall corrugated (DWC) incl couplers,bends etc of size 50 mm OD and ID 38mm confirming to IS 14930 -II and ISI Marked all specified and directed. |
| 82 | S&F GI tube light grade galvanised with all fittings laid in trenches of following size (a)50 mm bore. |
| 83 | Material and Labour for cutting bituminous road at a width not more than 30cm and a depth not exceeding 60 cm for laying of pipes on road crossing for cable protection and making goodwith cement concrete 1:2:4, type, B-2 to match the existing surfaces of the road all as specified and as directed by Engineer in charge. |