| Sl. No. | Item Description |
| 1 | Excavation in trenches n.exc 1.5 mtr wide and n.exc 1.5 mtr in depth for laying of pipes /Cables etc and getting out in soft / loose soil complete all as specified and as directed. |
| 2 | Excavation in trenches n.exc 1.5 mtr wide and n.exc 1.5 mtr in depth for laying of pipes/Cableetc and getting out in soft disintegrated rock/Road cuttings complete all as specified and as directed. |
| 3 | Removing surplus soil to a distance n.exc 50 mtr and depositing where directed at a level n.exc 1.5 mtr above the starting point complete all as specified and as directed. |
| 4 | Returning filling in trenches including spreading, leveling, watering and well ramming in layers n . Exc 25 cm complete all as specified and as directed. |
| 5 | Material and labour for Repairs of pipe lines and Attending emergency water supply breakdown complaints within 6 hours on telephonic intimation/SMS by arranging JCB/Excavator for excavation, breaking footpath paved with PCC blocks, PCC flooring, bituminus road etc up to 4 mtrs depth, dewatering with suitable dewatering pump, cutting and removing defective pipes, lowering the required size of pipes, valves and fittings with the help of crane and welding works if any, refilling the trench after repair with excavated soil, relaying of removed PCC blocks and matching with sorroundings etc complete including PCC work as directed at site.NOTE :- (1) Materials required for the repairs such as pipes, fittings, valves, Mechanical joints, PCC, PCC blocks etc will be measured and paid under relevant item.( 2) Items such as Rubber gaskets, Nuts,bolts, washers and lathe work required to bring the pipe line of required size etc are to be included in the quoted rate. (3) the contractor shall provide sufficient barricades, caution tape, danger boards etc at work site to avoid any accidents at site. 4) If the contractor fails to start the work within 6 hours on receipt of telephonic intimation /SMS , Necessary recovery will be made twice the quoted rates of respective items.5) Compensation if any due to any accident at site to be borne by the contractor. |
| 6 | Material and labour for repair of water supply distribution fresh water pipe line (forAttending emergency water supply breakdown complaints ) with mechanical joint, of CI/GI/DI pipe linesize up to 100mm including taking out the puncture/cracked existingpipe and transport to local workshop, cutting of damaged portion of pipe through welding/gas welding, making rough surfaces smooth and champhered by grinding and than connected through mechanical joint of adequate size with rubber rings both sides and fastener of required size and shape complete as per site requirement.NOTE :- Testing/commissioning the pipe line on full pressure after complete the job will be carried out and payment will made of this job if found sucess other wise the same will be redone again and no extra payment will be made on this account and minors accesories included in qouted rate.. |
| 7 | Material and labour for taking up cast iron water mains (incl all fitting) 80mm bore dia of pipe with spigot and socket ends from trenches complete all as specified and as directed. |
| 8 | Description all as item no.7 above but size of pipe 100 mm bore |
| 9 | Description all as item no.7 above but size of pipe 150 mm bore |
| 10 | Description all as item no.7 above but size of pipe 200 mm bore |
| 11 | Description all as item no.7 above but size of pipe 250 mm bore |
| 12 | Supply and layof centrifugally cast (spun) ductile ironwith spigot & socket end, 80 mm dia class K-7 conforming to IS: 8329/2000 complete with (push-on) rubber gasket jointing and centrifugally applied inside cement mortar lining with portland slag cement as per IS: 455:1989 and external metallic zinc coating as per annex A of IS 8329 with finishing layer of Bitumen coating as per Annex C of IS: 8329. The standard lengths of the pipes are 5.50 meter (subject to tolerance as per clause 15.5.1 of IS: 8329:2000) all as specified and as directed. |
| 13 | Supply and layof centrifugally cast (spun) ductile ironwith spigot & socket end, 100 mm dia class K-7 conforming to IS: 8329/2000 complete with (push-on) rubber gasket jointing and centrifugally applied inside cement mortar lining with portland slag cement as per IS: 455:1989 and external metallic zinc coating as per annex A of IS 8329 with finishing layer of Bitumen coating as per Annex C of IS: 8329. The standard lengths of the pipes are 5.50 meter (subject to tolerance as per clause 15.5.1 of IS: 8329:2000) all as specified and as directed. |
| 14 | Supply and layof centrifugally cast (spun) ductile ironwith spigot & socket end, 150 mm dia class K-7 conforming to IS: 8329/2000 complete with (push-on) rubber gasket jointing and centrifugally applied inside cement mortar lining with portland slag cement as per IS: 455:1989 and external metallic zinc coating as per annex A of IS 8329 with finishing layer of Bitumen coating as per Annex C of IS: 8329. The standard lengths of the pipes are 5.50 meter (subject to tolerance as per clause 15.5.1 of IS: 8329:2000) all as specified and as directed. |
| 15 | Supply and layof Centrifugally cast (spun) ductile ironwith spigot & socket end, 200 mm dia class K-7 conforming to IS: 8329/2000 complete with (push-on) rubber gasket jointing and centrifugally applied inside cement mortar lining with portland slag cement as per IS: 455:1989 and external metallic zinc coating as per annex A of IS 8329 with finishing layer of Bitumen coating as per Annex C of IS: 8329. The standard lengths of the pipes are 5.50 meter (subject to tolerance as per clause 15.5.1 of IS: 8329:2000) all as specified and as directed. |
| 16 | Supply and layof centrifugally cast (spun) ductile ironwith spigot & socket end, 250 mm dia class K-7 conforming to IS: 8329/2000 complete with (push-on) rubber gasket jointing and centrifugally applied inside cement mortar lining with portland slag cement as per IS: 455:1989 and external metallic zinc coating as per annex A of IS 8329 with finishing layer of Bitumen coating as per Annex C of IS: 8329. The standard lengths of the pipes are 5.50 meter (subject to tolerance as per clause 15.5.1 of IS: 8329:2000) all as specified and as directed. |
| 17 | Material and labour for cutting cast iron pipes in position for insertion of fittings, mechanical joints, replacement of pipes etc for bore of pipe 80mm complete all as specified and as directed. |
| 18 | Description all as item no.17 above but 100 bore pipes |
| 19 | Description all as item no.17 above but 150 bore pipes |
| 20 | Description all as item no.17 above but 200 bore pipes |
| 21 | Supply and fixing in repair MS mechanical joint with rubber washer, mild steel screw bolts (machine made) with screwed both ends of dia as per flange hole and required lengtheach screwed end to be fitted with washers and one hexagonal nut suitable for bore of pipe 80mm complete all as specified and as directed. |
| 22 | Description all as item no.21 above but 100 mm size. |
| 23 | Description all as item no.21 above but 150 mm size. |
| 24 | Description all as item no.21 above but 200 mm size. |
| 25 | Material and labour for ductile iron fittings such as bends (any type, radius and angle), tapers any type (straight, bend, incresing, decreasing or double socket etc.), Tee piece, single branch \"Y\"junction double branch, collar etc., caps and plugs etc. as per IS: 9523-2000 of class K-7,with internal cement mortor lining, and external zinc and black bitumen coated of dia upto 150 mm complete all as specified and as directed. |
| 26 | Material and labour for taking up worn out GI steel tubing incl all fitings fron trenches of 15 mm bore complete all as specified and as directed. |
| 27 | Description all as item no.26 above but 20 mm bore pipes. |
| 28 | Description all as item no.26 above but 25 mm bore pipes. |
| 29 | Description all as item no.26 above but 40 mm to 50 mm bore pipes. |
| 30 | Description all as item no.26 above but 80 mm bore pipes. |
| 31 | Description all as item no.26 above but 100 mm bore pipes. |
| 32 | Description all as item no.26 above but 150 mm bore pipes. |
| 33 | Material and labour forlaying in trenches/fixed to wall galvanised steel water tubing 15 mm bore, medium gradewith and including all medium grade fittings complete all as specified and as directed. |
| 34 | Description all as item no.33 above but 20 mm bore pipes. |
| 35 | Description all as item no.33 above but 25 mm bore pipes. |
| 36 | Description all as item no.33 above but 40 mm bore pipes. |
| 37 | Description all as item no.33 above but 50 mm bore pipes. |
| 38 | Description all as item no.33 above but 80 mm bore pipes. |
| 39 | Description all as item no. 33 above but 100 mm bore pipes. |
| 40 | Description all as item no.33 above but 150 mm bore pipes. |
| 41 | Material and labour for HDPE pipe 15 mm bore laying in trenches/fixed to wallincluding allfittings complete all as specified and as directed. |
| 42 | Description all as per item No. 41 above but of size 20 mm bore complete all as specified. |
| 43 | Description all as per item No. 41 above but of size 25 mm bore complete all as specified. |
| 44 | Description all as per item No. 41 above but of size 40 mm bore complete all as specified. |
| 45 | Description all as per item No. 41 above but of size 50 mm bore complete all as specified. |
| 46 | Supply and fix in replacement gun metal gate valve with iron wheel head, screwed both ends for iron pipes 15mm bore complete all as specified and as directed. |
| 47 | Description all as item no.46 above but 20 mm bore |
| 48 | Description all as item no.46 above but 25 mm bore |
| 49 | Description all as item no.46 above but 40 mm bore |
| 50 | Description all as item no.46 above but 50 mm bore |
| 51 | Supply and fix of sluice valve of class PN 1.6 with steel spindle and both ends flanged of 80 mm bore,alongwithbrass nut, gasket etc with both ends flanged confirming to IS-14846 with standard bolts hole, fixing with nuts, bolts, washers, rubber gasket etc completein position of pipe line all as specified and as directed. |
| 52 | Supply and fix of sluice valve of class PN 1.6 with steel spindle and both ends flanged of 100 mm bore,alongwithbrass nut, gasket etc with both ends flanged confirming to IS-14846 with standard bolts hole, fixing with nuts, bolts, washers, rubber gasket etc completein position of pipe line all as specified and as directed. |
| 53 | Supply and fix of sluice valve of class PN 1.6 with steel spindle and both ends flanged of 150 mm bore,alongwithbrass nut, gasket etc with both ends flanged confirming to IS-14846 with standard bolts hole, fixing with nuts, bolts, washers, rubber gasket etc completein position of pipe line all as specified and as directed. |
| 54 | Supply and fix of sluice valve of class PN 1.6 with steel spindle and both ends flanged of 200 mm bore,alongwithbrass nut, gasket etc with both ends flanged confirming to IS-14846 with standard bolts hole, fixing with nuts, bolts, washers, rubber gasket etc completein position of pipe line all as specified and as directed. |
| 55 | Supply and fix of sluice valve of class PN 1.6 with steel spindle and both ends flanged of 250 mm bore,alongwithbrass nut, gasket etc with both ends flanged confirming to IS-14846 with standard bolts hole, fixing with nuts, bolts, washers, rubber gasket etc completein position of pipe line all as specified and as directed. |
| 56 | Supply and fix of sluice valve of class PN 1.6 with steel spindle and both ends flanged of 300 mm bore,alongwithbrass nut, gasket etc with both ends flanged confirming to IS-14846 with standard bolts hole, fixing with nuts, bolts, washers, rubber gasket etc completein position of pipe line all as specified and as directed. |
| 57 | Supply and fix cast iron air release valves with twin globe air outlet,100 mm dia flanged including fittings as required at site, making necessary modification/ arrangements and on CI/MS/DI pipeline of bore up to 450 mm complete including taking down old unsv air release valve all as specified and directed. |
| 58 | Material and labour for spray Painting ofvarious pump set andold metal surface such as suction /delivery pipes,with 2 coats of synthetic enamel paint, marking arrows, writing letters etc including preparation of surface by rubbing and removing complete all as specified and as directed. |
| 59 | Colour code painting of supply mains pipe line, raising main pipe line,overflow pipe, washout pipe at each pupm house by applying two coats anti rust paint over a coat of red oxide primere complete all as speificed and as directed. |
| 60 | Supply and fix in replacement Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position of capacity500 Ltrs complete all as specified and as directed. |
| 61 | Supply and fix in replacement ofcast Iron swing check non return valve confirming to IS : 5312 (Part I) of 1969, both end flanged with rubber gasket & Nuts, bolts & washers of sizes 150 mm bore complete all as specified and as directed. |
| 62 | Supply and fix in replacement ofcast Iron swing check non return valve confirming to IS : 5312 (Part I) of 1969, both end flanged with rubber gasket & Nuts, bolts & washers of sizes 100 mm bore complete all as specified and as directed. |
| 63 | Supply and fix in replacement cast Iron foot valve confirming to IS : 4038 flanged endwith rubber gasket, Nuts, bolts & washers of sizes 150 mm bore complete all as specified and as directed. |
| 64 | Description all as item no. 63 above but 100 mm bore |
| 65 | Description all as item no 63 above but 80 mm bore |
| 66 | Description all as item no. 63 above but 200 mm bore |
| 67 | Material and labour and replaceing old unsvbrick masonry valve pit chamber of internal dimension 120 cm x 120 cm x 120 cm depth with sub class \"B\" bricks in CM (1:4) and 10 mm thick plastering in CM (1:4), PCC (1:4:8) type D2 (Using 40 mm graded broken stone aggregate) as in foundation lean concrete, PCC (1:3:6) type CI (using 20 mm graded broken stone aggregate) as in bedding and copping MS frame with 40 x 40 x 6 mm angle iron 3 mm thick MS sheet cover plate with locking arrangements, hinges and two coats of synthetic enamel paint over one coat of red oxide primer including preparation of surface, three coats of white wash on plastered surface (exposed to view) including necessary excavation in soft loose, soil, returning filling in and removal of surplus soil to a distance not exceeding 50 m complete all as specified and directed. |
| 68 | Material and labour for valve pit of size 90cm x90cm x 90cm in brick masonry for sluce valves constructed completely with 3.15 MM thick MS sheet cover angle iron frameand locking arrangement including earth work PCC plastering and painting etc suitable for 150 MM dia and 200 MM dia. |
| 69 | Cleaning of valve pits of any size upto 1.20 x 1.20 mtrs x 1.20 mtr deep by taking out of all mud /earth etc including cleaning/greashing/oiling of sluice valves / Gate valves and painting the Valves and pit cover etc. |
| 70 | Material and labour for angle iron frame and MS cover for valve chambers and duct covers., Pump motor base frame of ISMB etc as per existing size and shape including two coat of painting over one coat of red oxidecomplete with taking down old unsv ange iron frameall as specified and as directed. |
| 71 | Material and labour for PCC 1:3:6 type-C2 (using 40mm graded stone aggregate) as in foundation, filling and mass concrete incl necessary form work wherever required and incl demolition of cement concrete (un-reinforced) of any description and in any position not otherwise specifically provided for, all as specified and as directed at site. |
| 72 | Supply and fixing hot dipped galvanized chain link Fencingwith Zinc Coating, nominal height-2400mm, Pitch-50mm and wire dia 3.15 mm. (approx weight-2.55 Kg /Sqm) complete with taking down old unsvall as specified and as directed. |
| 73 | Material and labour for mild steel work of angle fixed independently for fencing post and others confirming to Gde Fe 410-A incl cutting to dead end length where required, notching, drilling, fitting and/or welding or connecting with bolts and nuts incl dismantling taking down unsv one complete all as specified and as directed. |
| 74 | Material and labour for TMT bars 10mm dia and over cut to length, bent to shape required, including cranking, bending spirally for hooping for columns hooking ends or as in horizontal bar for fixing in fencing and binding with and including mild steel wire (anealed) not less than 0.9mm dia or securingwith clips complete for support of chain link fencing incl dismantling taking down unsv one all as specified and as directed. |
| 75 | Labuor for dismantling taking out complete pump of any type, capacity upto 25 HP of different models from foundation including dismentling suction and delivery pipe connection from pump , carrying to wksp & back and repair/overhauling complete and reassemble and fixing to original position after repair/overhauling with nuts, bolts, washers, pipe connection complete including testing, commissioning all as specified and as directed.NOTE :-1. Spares required for the repairs will be measured and paid separately. 2. Small items such as gaskets, Nuts,bolts and washers, screws, consumable like grease etc will be inclusive of item rates.and Major spare parts shall be measeared and paid seprately |
| 76 | Supply and fix Ball Bearing, (DE). |
| 77 | Supply and fix Ball Bearing (NDE). |
| 78 | Supply and fix Impeller. |
| 79 | Supply and fix Pump Shaft. |
| 80 | Supply and fix Lantern Ring. |
| 81 | Supply and fix Mechanical Seal. |
| 82 | Supply and fix Water Deflector. |
| 83 | Supply and fix Bush |
| 84 | Supply and fix Key Impeller. |
| 85 | Supply and fix Gland Packing. |
| 86 | Supply and fix Gasket set |
| 87 | Labour for Dismantling taking out Induction motor upto 10 to 20 HP from foundation by removing electric connection, coupling carefully and carrying to wksp & back for repair complete and reassemble and fixing to original position after repair/overhauling with nuts, bolts, washers, pipe connection and cable connection complete including testing, commissioning, proper alignment all as specified and as directed. |
| 88 | Material and labour for complete rewinding of motor any type after cutting, taking out old damaged winding from stator core, cleaning of slots, providing proper insulating materials/lock strip in the slots, rewinding with existing size of super enamelled copper wire, required binding, bonding, insulation, varnishing and drying and proper testing after rewinding for the following sizes of motor capacity upto 10 to 25HP all as specified and as directed. |
| 89 | Material and labour for complete rewinding of motor any type after cutting, taking out old damaged winding from stator core, cleaning of slots, providing proper insulating materials/lock strip in the slots, rewinding with existing size of super enamelled copper wire, required binding, bonding, insulation, varnishing and drying and proper testing after rewinding for the following sizes of motor capacity upto 25 to 30HP all as specified and as directed. |
| 90 | Supply and fix in replacement automatic Star delta starter for centrifugal pump set of capacity upto 20 HP conforming to IEC-60947-4-1 / IS-13947-4-1, 3 phase 415 volt 50 Hz with CRCA sheet steel enclosure complete with heavy duty 4 pole contactor with wide band operating coil, overload relay for motor protection and electronic star delta timer, single phase preventer,etc complete all as specified and as directed. |
| 91 | Material and labour for following chemicals for water treatment :- |
| 92 | supply only alum ferric Gde -I complete all as specified and as directed. |
| 93 | Supply only hydrated Lime suitable for drinking water complete all as specified and as directed. |
| 94 | Supply and fix in replacement MCCB 200 Amp ,415 Volt, 25 KA, 4 pole Rated Ultimate Shortcircuit Breaking Capacity Icu at 415 V (kA rms) Vac (kA rms), Rated Service short circuit Breaking Capacity Ics = % Icu at 415 V (kA rms) 50%, frame HIM125 type,Confirms to IS/IEC60947-2complete all as specified and as directed. |
| 95 | Supply and fix in replacement MCCB 100 Amp ,415 Volt, 25 KA, 4 pole rated ultimate shortcircuit breaking capacity Icu at 415 V (kA rms) Vac (kA rms), Rated Service short circuit Breaking Capacity Ics = % Icu at 415 V (kA rms) 50%, frame HIM125 type,Confirms to IS/IEC60947-2complete all as specified and as directed. |
| 96 | Supply and fix in replacement MCCB 63 Amp ,415 Volt,25 KA, 4 pole Rated Ultimate Shortcircuit Breaking Capacity Icu at 415 V (kA rms) Vac (kA rms), Rated Service short circuit Breaking Capacity Ics = % Icu at 415 V (kA rms) 50%, frame HIM125 type,Confirms to IS/IEC60947-2complete all as specified and as directed. |
| 97 | Supply and fix in replacement MCB 63 Amps Triple pole 240 Volts 10 KA C curvecomplete all as specified and as directed. |
| 98 | Supply and fix in replacement MCB SPN 40 Amps C Curvecomplete all as specified and as directed. |
| 99 | Supply and fix in replacement MCB SP 6-32 Amps 240 Volts 10 KA C curve complete all as specified and as directed. |
| 100 | Supply and fix in repair AC power contactor, 3 pole, 3 ph, 415V, AC, 50Hz, type- MNX40 capacity 40AMP.complete all as specified and as directed. |
| 101 | Supply and fix in repair AC side mounting add on aux contact block forcontactor complete all as specified and as directed. |
| 102 | Supply and fix in repair AC front add on aux contact block complete all as specified and as directed. |
| 103 | Supply and fix in repair thermal overload relays, relay range 15 Amps to 33 Amps as applicable complete all as specified and as directed. |
| 104 | Supply and fix in repair electronic timer, 3 - 30 Sec 415V complete all as specified and as directed. |
| 105 | Supply and fix in repair Motor protection relay VPPD2-415V AC, complete all as specified and as directed. |
| 106 | Supply and fix in repair Single Phase Preventor relay, complete all as specified and as directed. |
| 107 | Material and labour in star delta starter panel wiring with connected accesories complete all as specified and as directed. |
| 108 | Material and labour for 10 sqmm five core stranded copper conductor alongwith copper lugs including connecting from pump set to starter complete all as specified and as directed. |
| 109 | Material and labour for LT panel board factory made, indoor type dust and weather proof,fabricatedwith 3.00 mm CRCA sheetof suitable size confirming to IP 54 protection complete including aluminium bus bar 200 Amps, 4 strip mounted on porcelain insulated & enclosed in chamber, bottom cable entry comprising of following:(A) INCOMING (a) MCCB 160 Amp ,415 Volt,25 KA, 4 pole Rated Ultimate Shortcircuit Breaking Capacity Icu at 415 V (kA rms) Vac (kA rms), Rated Service short circuit Breaking Capacity Ics = % Icu at 415 V (kA rms) 50%, frame HIM125 type, Confirms to IS/IEC60947-2- 01 No (b) On load change over switch of capacity 160 Amps 04 pole confirm to IS/IEC : 60947-3- 01 No. (B) OUTGOING (a) MCCB 63 Amp , 415 Volt,25 KA, 4 pole Rated Ultimate Shortcircuit Breaking Capacity Icu at 415 V (kA rms) Vac (kA rms), Rated Service short circuit Breaking Capacity Ics = % Icu at 415 V (kA rms) 50%, frame HIM63 type,Confirms to IS/IEC60947-2- 01 No---02 Nos.(b) On l Star Delta starter 25 HP, contactor rating 40 Amp, overload relay range 28 - 40 Amp, confirm to IS/IEC 60947-4-1 , provided with protetion degree, Air break type - 02 Nos |
| 110 | Contd from,,..109.00(c) Outgoing MCB SPN 32 Amps 240 Volts, 10 KA - 02 Nos.( d) Combined Digital Voltmeter and Ammeter 0-500 V 96x96xm …. 01 NoIndicating lamps set RYB …. 01 set. (e)Panel mounted type digital multifunctional energy meter, CT operated, LT 3 phase, 4 wire, including CT of suitable ration- 01 Nos (i) motor protector |
| 111 | Supply only pure PTFE Gland Packing Rope suitable for valves/Pumps complete all as specified and as directed. |
| 112 | Supply and fixrubber gasket /packing 4mm thicksuitable for valve/pump/suction sweeper complete all as specified and as directed. |
| 113 | Supply, Installation, Testing and commissioning of Ultrasonic LevelTransmitter at Sump for measurement of water level with following specification:- Range : 0-8 metersAccuracy : 0.5 % minimum Supply Voltage : 24V DCOutput : 4-20 mA , 0-10V DC Make: Nivelco / Siemens / BannerMake: Nivelco / Siemens / BannerNote : Contractor shall submit a \"MOU\" from OEM on a non-judicial stamp paper of RS. 100.00 duly notarized with an undertaking stating that execution of all automation related items of work shall be carried out under technical support and guidance of OEM. MOU should be taken from M/s Universal Switch gear control / ABB automation / Tricolite and GE automation. |
| 114 | Supply, Installation Testing & Commissioning of Outdoor type having Canopy and Double Door for weather protection, PLC ( Programmable Logic Controller) based Automation, Protection Panel suitable for control and monitoring of 01 Nos. Ultrasonic Sensor. The panel should be of minimum size 600(H) X 600(W) X 250(D) mm fabricated from 3.15 mm CRCA Sheet. The Panel shall be comprised the following functions & items:- (i) Water Level Sensing & Display(ii)01 No. PLC with following specifications:- (a) Non isolated RS 485 communication port or Ethernet communication port.(b) Suitable No. of digital / analog input and outputs.(c) Programming software based on IEC to facilitate building of custom build function blocks.Contd to...113.01 |
| 115 | Contd from,,.... 113.00(iii) 01 no. HMI- 7\"Graphical Touch screen display (a). Should have 01 No. RS 485 and 01 No. USB programming port. (b). Should have USB downloading port.(c). Support external data storage on a USB memory stick for storing production data and backing up applications(iv) 01 No. SMPS of 1.5A rating as suitable according to panel design.(v) MCB rating 6-10A. (vi) Indicator lamp :- As per requirementCRCA Enclosure:- Make (UNIVERSAL SWITCH GEAR CONTROL / HOFFMAN / ADLEC / TRICOLITE )Make of the PLC based panel:- (Universal Switch Gear Control or equivalent inABB Automation/Tricolite/GE Automation)NOTE :- The sensor shall be work upto 250 RM distance from the tank and Screen shall be installed at Pump room complete all as specified and asdirected. |
| 116 | Supply and fixing2 core 1.50 sqmm PVC sheathed PVC insulated copper armoured cable complete all as specified and as directed. |
| 117 | Supply and fixing 4 core 1.50 sqmm PVC sheathed PVC insulated copper armoured cable complete all as specified and as directed . |
| 118 | Material and labour for cleaning of MES water supply installations / campus of Age E/M-I AOR approx area 1500 sqmby surface dressing or trimming of natural ground to remove small unequalities n.exc 15 cm deep ( including removing vegetation / shrubs / brush wood / under-growth ), cleaning of drains & carrying away the rubbish to a distance of n.exc 50 mtr away complete all as specified and as directed . |
| 119 | Supply, filling (at contractor source) and distribution of water supply through Water Bowser of capacity 12000 Ltr having pumping arrangment with pipe miniumn 15 mtr supply to the PVC tank directly through pipe on the roof upto height of 10 mtr complete including necessary arrangement.NOTE :- Demand of water bowser will be given to contractor at any time between 0800 to 2200 Hrs and has to be supplied within 03 hrs after notification, failing to which Rs 300/- per hours per demand will be recoverd. Amount of Pumping arrangement, petrol and pipe etc are included in the quoted rate. No extra payment will be given. |
| 120 | Material and labour for mechanized cleaning and disinfection of OHT with Six (6) stages possess mechanical dewatering, distillery and remove of left Over dirty water sludge, Clean the wall, roof and floor 1 Lakh gallons capacity upto 45 mtr stagging with the following stages :-STAGE - IMechanized Dewatering - Mechanized Dewatering should be done by dewatering pump having , suitable outlet and discharge and control panel. The details of motor cable, seal, material of construction andcontrol panel should be furnished.STAGE – IISludge Removal – Desilting and removalof left over dirty Water sludge with a sludge removal pump.STAGE – IIIHigh Pressure Cleaning – Cleaning of wall , ceiling , and floor by high pressure of 80-180 bars. Cleaning should be done by high pressure cleaner with following specification Fully automatic controlled, auto start –slop, imported high pressure cleaning machined having F-Classinsulation protection. The heavy duty machined should be operated byHPC operator, on Continuous duty in variable fully adjustable mode from working presser of 100-180 bars. The machine should have imported twin steel core protection rubber high pressure hose to safety. With stand operating pressure of 250 bar, and Two cleaning lances, onewith rotary jet and the second one , a flat jet for effective Drinking Water Tank Operation. Contd to...118.01 & 118.02 |
| 121 | Contd from,,.... 118.00STAGE – IVVacuumCleaning – Removal of remaining sludge from the floor with the help of industrial vacuum cleaner .(A)Removalof remaining sludge with the help of imported heavy duty industrial vacuum cleanerand sludge sucker having maximum power of 1200 watt, with suitable heavy duty motor.(B)Imported sludge sucker should be a part of the highpressure system which sucks sludge and through the same out of the tank , his must handle solid particles as well.STAGE – VAnti- Bacterial Spry – Spring of non- toxic- biodigrable, ecofriendly anti-bacterial agentto disinfect the tank from all harmful pathogens. The dose utilized should be safe as per WHO guideline.STAGE – VIUV Radiator – Treatment of inside of tank by exposing UV radiator to kill further suspended or floating bacteria if any- Treatment of inside tank be done by exposing UV radiation by imported heavy duty UV radiator. The radiator should be designed in away to ensure 360 degrees of sterilization and should have suitable lamps for effective sterilization for a period of 8000 working hours, the radiator must be totally portable and effective for final sterilization of drinking water tanks for elimination of floating and suspended bacteria….. |
| 122 | NOTES :-i)Contractor must clean and disinfect the water storage tank within 12 hours aftergiving the site by Engr-in-Charge to avoid the inconvenice for distribution of water supply to the connected area. ii) Contractor should be provide all safety tools to worker, in case of any accident during the work in progress the contractor will be fully responsibleto give necessary medical aids and also compensate to workerunder compensation act 1923. iii)No extra payment will be made for transportation of any machinaries required for cleaning and disinfecton the storage tank iv)Contractor must write the date of cleaning and capacity of tank at the wall of the storage tank in size of 2 ft x 2 ft base prepared by enamel paint. Base should be in light blue colour and letters should be white colour without extra payment.vi)While execution the work contractor must have all safety equipment and follow all safety parameter at site. |
| 123 | M&L for Mechanized Cleaning and Disinfection of OHT with Six (6) Stages possess Mechanical Dewatering, Distillery and remove of left Over dirty water sludge, Clean the wall, roof and floor 50 thousand gallons capacity upto 45 mtr stagging with the following stages :-STAGE - IMechanized Dewatering - Mechanized Dewatering should be done by dewatering pump having , suitable outlet and discharge and control panel. The details of motor cable, seal, material of construction andcontrol panel should be furnished.STAGE – IISludge Removal – Desilting and removalof left over dirty Water sludge with a sludge removal pump.STAGE – IIIHigh Pressure Cleaning – Cleaning of wall , ceiling , and floor by high pressure of 80-180 bars. Cleaning should be done by high pressure cleaner with following specification Fully automatic controlled, auto start –slop, imported high pressure cleaning machined having F-Classinsulation protection. The heavy duty machined should be operated byHPC operator, on Continuous duty in variable fully adjustable mode from working presser of 100-180 bars. The machine should have imported twin steel core protection rubber high pressure hose to safety. With stand operating pressure of 250 bar, and Two cleaning lances, onewith rotary jet and the second one , a flat jet for effective Drinking Water Tank Operation. Contd to...119.01 & 119.02 |
| 124 | Contd from,,.... 119.00STAGE – IVVacuumCleaning – Removal of remaining sludge from the floor with the help of industrial vacuum cleaner .(A)Removalof remaining sludge with the help of imported heavy duty industrial vacuum cleanerand sludge sucker having maximum power of 1200 watt, with suitable heavy duty motor.(B)Imported sludge sucker should be a part of the highpressure system which sucks sludge and through the same out of the tank , his must handle solid particles as well.STAGE – VAnti- Bacterial Spry – Spring of non- toxic- biodigrable, ecofriendly anti-bacterial agentto disinfect the tank from all harmful pathogens. The dose utilized should be safe as per WHO guideline.STAGE – VIUV Radiator – Treatment of inside of tank by exposing UV radiator to kill further suspended or floating bacteria if any- Treatment of inside tank be done by exposing UV radiation by imported heavy duty UV radiator. The radiator should be designed in away to ensure 360 degrees of sterilization and should have suitable lamps for effective sterilization for a period of 8000 working hours, the radiator must be totally portable and effective for final sterilization of drinking water tanks for elimination of floating and suspended bacteria….. |
| 125 | NOTES :-i)Contractor must clean and disinfect the water storage tank within 12 hours aftergiving the site by Engr-in-Charge to avoid the inconvenice for distribution of water supply to the connected area. ii) Contractor should be provide all safety tools to worker, in case of any accident during the work in progress the contractor will be fully responsibleto give necessary medical aids and also compensate to workerunder compensation act 1923. iii)No extra payment will be made for transportation of any machinaries required for cleaning and disinfecton the storage tank iv)Contractor must write the date of cleaning and capacity of tank at the wall of the storage tank in size of 2 ft x 2 ft base prepared by enamel paint. Base should be in light blue colour and letters should be white colour without extra payment.vi)While execution the work contractor must have all safety equipment and follow all safety parameter at site. |
| 126 | M&L for mechanized cleaning and disinfection of OHT with Six (6) Stages possess Mechanical Dewatering, Distillery and remove of left Over dirty water sludge, Clean the wall, roof and floor 20 thousand gallons capacity upto 45 mtr stagging with the following stages :-STAGE - IMechanized Dewatering - Mechanized Dewatering should be done by dewatering pump having , suitable outlet and discharge and control panel. The details of motor cable, seal, material of construction andcontrol panel should be furnished.STAGE – IISludge Removal – Desilting and removalof left over dirty Water sludge with a sludge removal pump.STAGE – IIIHigh Pressure Cleaning – Cleaning of wall , ceiling , and floor by high pressure of 80-180 bars. Cleaning should be done by high pressure cleaner with following specification Fully automatic controlled, auto start –slop, imported high pressure cleaning machined having F-Classinsulation protection. The heavy duty machined should be operated byHPC operator, on Continuous duty in variable fully adjustable mode from working presser of 100-180 bars. The machine should have imported twin steel core protection rubber high pressure hose to safety. With stand operating pressure of 250 bar, and Two cleaning lances, onewith rotary jet and the second one , a flat jet for effective Drinking Water Tank Operation.Contd to 120.01 & 120.02 |
| 127 | Contd from,,.... 120.00STAGE – IVVacuumCleaning – Removal of remaining sludge from the floor with the help of industrial vacuum cleaner .(A)Removalof remaining sludge with the help of imported heavy duty industrial vacuum cleanerand sludge sucker having maximum power of 1200 watt, with suitable heavy duty motor.(B)Imported sludge sucker should be a part of the highpressure system which sucks sludge and through the same out of the tank , his must handle solid particles as well.STAGE – VAnti- Bacterial Spry – Spring of non- toxic- biodigrable, ecofriendly anti-bacterial agentto disinfect the tank from all harmful pathogens. The dose utilized should be safe as per WHO guideline.STAGE – VIUV Radiator – Treatment of inside of tank by exposing UV radiator to kill further suspended or floating bacteria if any- Treatment of inside tank be done by exposing UV radiation by imported heavy duty UV radiator. The radiator should be designed in away to ensure 360 degrees of sterilization and should have suitable lamps for effective sterilization for a period of 8000 working hours, the radiator must be totally portable and effective for final sterilization of drinking water tanks for elimination of floating and suspended bacteria….. |
| 128 | NOTES :-i)Contractor must clean and disinfect the water storage tank within 12 hours aftergiving the site by Engr-in-Charge to avoid the inconvenice for distribution of water supply to the connected area. ii) Contractor should be provide all safety tools to worker, in case of any accident during the work in progress the contractor will be fully responsibleto give necessary medical aids and also compensate to workerunder compensation act 1923. iii)No extra payment will be made for transportation of any machinaries required for cleaning and disinfecton the storage tank iv)Contractor must write the date of cleaning and capacity of tank at the wall of the storage tank in size of 2 ft x 2 ft base prepared by enamel paint. Base should be in light blue colour and letters should be white colour without extra payment.vi)While execution the work contractor must have all safety equipment and follow all safety parameter at site. |
| 129 | Material and labour for dismantling and taking out complete cholorine cylinder capacity 100 Kg for refiling carefully and carrying to wksp and back after refiling and reassembble,pipe connection at on original position all as specified and as directed. |
| 130 | Supply and fix in replacement Substation sign board made out of 3 mm thick aluminium composite panel sheet 1200 mm x 1200 mm including retro reflective sheeting on both side fixed on 50 mm dia stainless steel pipe of grade -304 (non scratchable) of wall thockness not less than 14 gauge including providing letters of not less than 75 mm height fixed on position with 50 mm dia stainless steel pipe (wall thickness of pipe shall be not less than 14 guage and vertical height of board above GL should be 2.4 m & below GL 60 cm deep ) and stainles steel pipe embedded in PPC 1:3:6 type C-1 using 20 mm graded stone aggregate in post holes of size 250 mm x 600 mm including 6 mm thick mild steel base size 200 mm x 200 mm X 600 mm including 6 mm thick mild steel base plate of size 200 mm x 200 mm x 6 mm thick for anchoring of post applying of two coats of anti corrossive paint on anchoring plate and writing letters and numbers on both sides of the board in English and Hindi (as required at site) should be as per IRC 30-1968 using 3M material, numbers of letters exc 50 but n exc 250 on each of the board etc complete all as specified and as directed. NOTE :- Square sign board should be cut in one coenerin half of width & depth of it all as specified by Engr-in-Charge. |
| 131 | Supply and fixing first aid kit box having following items : (a) Alcohol or non alcohol antiseptic wipes, Band-Aids, cotton Balls, Cotton Swabs, Bandages, Hydrogen Peroxide, Gauge Saline, Dressing, Adhesive bandages, Moleskin, Gloves, Goggles, Surgical mask, Apron, Trauma shears, Alcohol rub, Thermometer, space blanket, Penlight, paracetamol all as specified and as directed. |
| 132 | Supply and installation MMX CO2 4.5 Kg IS: 15683 (Squeez grip valve) carbon Di-oxide agent type fire extinguisher, ISI marked (ISI15683:2018) CE and EN certified, Containing CO2 gas having purity 99.7% filled in seamless cylinder, coated with High glossy PU paint, ISI marked Dual spindle valve with aluminium wheel and collar/Squeeze grip brass valve, aluminium siphon tube, High durability Vinyl label, QR code label with printed serial number, Individually packed in 7 ply corrugated paper box with wall bracket, screw & plugs complete all as specified and as directed. |
| 133 | M&L for layout plan board of EM Installation in size 4.0 feet x 3.5 feet made on high classPVC transpirent sheet minium 5 MM thick ( MES colour) and all side frame work using aluminium angle in size 35 MM width and 2 MM thick reviting around the board including hanging / fixing arrangement on surface of wall in installation. The given layout shall be drawn using different colour with location and other details complete all as specified and as directed. |
| 134 | Collection of raw water sample in sterilised sampling bottles and testiong from NABL accrediated lab and submission of test report in duplicate. Following parameters reqd to be check (pH,TDS,Turbity, Alkalinity, Acidity,Total Hardness as CaCo3, Calcium, Magnesium, Chloride, Sulphate, Iron, fluoride, Nitrate, Nitrite, Sodium, Potassium) NOTE :- Transportion Charges for collecting samples and further submission to NABL Accredited lab is included in quoted rate. |
| 135 | Supply and fixing water sprinkler 360 degree rotation water suitable for lawn or gardening complete all as specified and as directed. |
| 136 | Supply and fixing in replacement fire retardant / extinguishing electric insulated synthetic mat insulatica-2000 of 3.0 mm thick +10% confirming to BIS : DOC No ET-02 (5440) dated 30 Apr 2004, meeting requirement of IS-3043, IS-5216 (Part I, II, III) IS-8437 and IEC 479 pub I, tested for breakdown strength, tensile/Elongation ageing properties, insulation resistance, effect of acid, alkaline, diesel and transformer opil leakage current test, fire test etc. having minimum width of 1000 mm + 20 mm including all allied materials such as PU-resing, chemical bound (Haedener) special PVC adhesive liquid primer etc of required quantity to complete the job as per site requirement |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail