| 1 | Dismantling/ Taking out existing ACSR conductor any type and size complete all as specified and directed. |
| 2 | Dismantling of insulators of any type and size complete all as specified and directed. |
| 3 | Dismantling cross-arms of M.S. channel orangle sections etc. completeall as specified and directed. |
| 4 | Taking up/down old Under Ground cable of any size/type complete all as specified and directed. |
| 5 | Excavation in trenches not exc 1.50 Metre wide and not exc 1.50 Metre depth for laying of UG cable/Pole/Stays etc getting out in Soft/Loose Soil, complete all as specified and directed. |
| 6 | Returning, Filling in including Spreading, Leveling, Watering and Well Ramming in layers not exc. 25 Cm thick in Soils, complete all as specified and directed. |
| 7 | Removing Surplus soil to a distance not exc 50.00 Metre away and depositing where directed at a level not exc 1.50 Metre above the Starting Point, complete all as specified and directed. |
| 8 | M & L clean dry river sandin trenches/ducts for cushioning to cable, 8 cm in depth before laying the cable and 15 cm in depth after laying the cable complete all as specified and directed. Note:- Punned thickness shall be measured and paid. |
| 9 | M & L for sub class \"B\" brick of size 230x115x75mm laid flat work length equal to width of brick on sand for protection of under ground cable complete all as specified and directed. |
| 10 | M & L for Cement Concrete 1:3:6 type C2 (using 20 mm graded aggregate) as Lean Concrete for coping of pole, stay foundationetc including form work & finishing the surfaces even & smooth with out using extra cement complete all as specified and directed. |
| 11 | Supply,laying, connecting and testing 1100 volts grade, 400 sqmm, 3.5 core, heavy duty cable with XLPE insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape including complete all as specified and directed. (Note : Excavation, earth work, bricks protection and sand cushioning will be measured and paid separately). |
| 12 | Description all as per item No 11 above but cable size 300 Sqmm 3.5 core |
| 13 | Description all as per item No 11 above but cable size 240 Sqmm 3.5 core |
| 14 | Description all as per item No 11 above but cable size 150 Sqmm 3.5 core |
| 15 | Description all as per item No 11 above but cable size 120 Sqmm 3.5 core |
| 16 | Description all as per item No 11 above but cable size 70 Sqmm 3.5 core |
| 17 | Description all as per item No 11 above but cable size 50 Sqmm 3.5 core |
| 18 | Description all as per item No 11 above but cable size 35 Sqmm 3.5 core |
| 19 | Description all as per item No 11 above but cable size 25 Sqmm 4 core |
| 20 | Description all as per item No 11 above but cable size 16 Sqmm 4 core |
| 21 | Description all as per item No 11 above but cable size 10 Sqmm 4 core |
| 22 | S&F junction box water proof out door type made out of SMC Sintex make of interrnal dimensions 200 mm x 160 mm x 98 mm single door type hinged with locking arrangement front operated with one number MCB SP 10 Amps capacity, for housing 3 phase and neutral Aluminium bus bar, including connecting the incoming/out going cables including cable glands SMC coated clamps bolts etc all as directed and fixed to the poles with mild steel flat of size 25 mm x 4 mm, complete all as specified and directed. |
| 23 | S & F for PVC insulated, PVC sheathed multistranded copper conductor cable of size 3 core 2.50 Sqmm with necessary electrical connections from connector block to junction box with suitable length of 20 mm PVC rigid conduit heavy duty ISI marked complete all as directed and fixed to the poles with mild steel flat ofsuitable size complete all as specified and directed. |
| 24 | S & F Cable route indicator / Marker made up of PCC Block in cement mortar 1:3:6 ( 20 mm graded aggregrate ) of size 900 x 300x 100 mm thick with DANGER / LT 415 V CABLE /MES embossing on cable route Indicator / Marker including painting as per approved colour and buried in ground 45 Cms including necessary earth work (as required / ordered at site) complete all as specified and as directed |
| 25 | Design,Supply, installation, testing and commissioning ofCubical type floor mounted LT panel, CPRI approved, Outdoor typefactory fabricatedmade out of CRCA sheet of 3.15 mm thick ,fully enclosedand angle iron frame of size 40 x 40 x 6mm thick and T section with front openabledouble door shutter, dust and vermin proofand rear openingcomplete with locking arrangement, having a system of bus barsof aluminiumof suitable size600 Amps duly insulated and mounted on Epoxy/porcelain insulators in totally enclosed chamber with three phase and neutral 415volts, AC, system prewired with suitable copper wire PVC insulated with all control accessories, provn of suitable cable glands, duly powder coated of approved quality over a coat of red primer with sufficient free space complete all as specified and directed.and taking down of old U/S LT Panel complete to include the following accessories:- (For Transformer 315 KVA Main Panel)(a) MCCB 4 Pole, 415 V, Adjustable type, Microprocessor with int release, 630 Amps with breaking capacity 50 KA -01No (b) MCCB 4 Pole, 415 V, adjustable type, Microprocessor with int release, 250 Amps with breaking capacity 35 KA-04 Nos(c) MCCB 4 Pole, 415 V, fixed type, 200 Amps with breaking capacity 35 KA-01 No (d) Multi function meter with KWH, voltage, Amp, frequency meter as per incoming load with CTs of suitable rating. Make AE/L&T/Havells(e) Indicator lampRYB- 01 SetMake of MCCBs :- Havells/Indoasian/Schneider/Siemens |
| 26 | Design,Supply, installation, testing and commissioning ofCubical type floor mounted LT panel, CPRI approved, Outdoor typefactory fabricatedmade out of CRCA sheet of 3.15 mm thick ,fully enclosedand angle iron frame of size 40 x 40 x 6mm thick and T section with front openabledouble door shutter, dust and vermin proofand rear openingcomplete with locking arrangement, having a system of bus barsof aluminiumof suitable size600 Amps duly insulated and mounted on Epoxy/porcelain insulators in totally enclosed chamber with three phase and neutral 415volts, AC, system prewired with suitable copper wire PVC insulated with all control accessories, provn of suitable cable glands, duly powder coated of approved quality over a coat of red primer with sufficient free space complete all as specified and directed and taking down of old U/S LT Panel complete to include the following accessories:-(For Transformer 300 KVA Main Panel)(a) MCCB 4 Pole, 415 V, Adjustable type, Microprocessor with int release, 600 Amps with breaking capacity 50 KA -01No(b) MCCB 4 Pole, 415 V, adjustable type, Microprocessor with int release, 250 Amps with breaking capacity 35 KA-03 Nos(c) MCCB 4 Pole, 415 V, fixed type, 160 Amps with breaking capacity 35 KA-01 No (For Street Light) (d) Multi function meter with KWH, voltage, Amp, frequency meter as per incoming load with CTs of suitable rating. Make AE/L&T/Havells(e) Indicator lampRYB- 01 SetMake of MCCBs :- Havells/Indoasian/Schneider/Siemens |
| 27 | Design,Supply, installation, testing and commissioning ofCubical type floor mounted LT panel,CPRI approved,outdoor typefactory fabricatedmade out of CRCA sheet of 3.15 mm thick ,fully enclosedand angle iron frame of size 40 x 40 x 6mm thick and T section with front openabledouble door shutter, dust and vermin proofand rear openingcomplete with locking arrangement, having a system of bus barsof aluminiumof suitable size of 350 Amps duly insulated and mounted on Epoxy/porcelain insulators in totally enclosed chamber with three phase and neutral 415volts, AC, system prewired with suitable copper wire PVC insulated with all control accessories, provn of suitable cable glands, duly powder coated of approved quality over a coat of red primer with sufficient free space complete all as specified and directedto include the following accessories:- (for Bldg No P-9 & P-11, P-5 & P-6, P-7 & P-15, P-12 & P-13, P-10 & P-4, P-3 & P-2, P-14 & P-1)(a)Supply and fix 4 Pole MCCB 250 Amp, Microprocessor with int release, 50 Hz, 415 V with rupturing capacity35 KA -01No(b) 4 Pole MCCB 160 Amp, 50 Hz, 415 V with rupturing capacity 35 KA - 2 Nos (c) Multi function meter with KWH, voltage, Amp, frequency meter as per incoming load with CTs of suitable rating. Make AE/L&T/Havells(d) Indicator lampRYB- 01 SetMake of MCCBs :- Havells/Indoasian/Schneider/Siemens |
| 28 | Design,Supply, installation, testing and commissioning ofCubical type floor mounted LT panel, CPRI approved, Outdoor typefactory fabricatedmade out of CRCA sheet of 3.15 mm thick ,fully enclosedand angle iron frame of size 40 x 40 x 6mm thick and T section with front openabledouble door shutter, dust and vermin proofand rear openingcomplete with locking arrangement, having a system of bus barsof aluminiumof suitable size600 Amps duly insulated and mounted on Epoxy/porcelain insulators in totally enclosed chamber with three phase and neutral 415volts, AC, system prewired with suitable copper wire PVC insulated with all control accessories, provn of suitable cable glands, duly powder coated of approved quality over a coat of red primer with sufficient free space complete all as specified and directed and taking down of old U/S LT Panel complete to include the following accessories:- (for Bldg No P-33 & P-8)(a) Supply and fix 4 Pole MCCB 250 Amp, Microprocessor with int release, 50 Hz, 415 V with rupturing capacity 35 KA -01No (b) MCCB 4 Pole, 415 V, fixed type, 100 Amps with breaking capacity 25 KA-01 No (c) 4 Pole MCCB 160 Amp, 50 Hz, 415 V with rupturing capacity 35 KA - 1 Nos (d) Multi function meter with KWH, voltage, Amp, frequency meter as per incoming load with CTs of suitable rating. Make AE/L&T/Havells(e) Indicator lampRYB- 01 SetMake of MCCBs :- Havells/Indoasian/Schneider/SiemensNote for Items25 to 28:- (i) The quoted rate shall include minor items such as screws, cable tie, copper cable 1.5/2.5 Sqmm, glands, lugs, nuts & bolts, washers, top insulators, sleeves, provision of extra holes in bus bar etc. (ii) All internal wiring shall be done with suitable size of PVC insulated solid copper conductor FRLS cable conforming toIS-694. (iii) Panel drawing shall be got approved before placing of orderfrom Engr-in-Charge/GE. (iv) The bus connection for cable from main bus bar to outgoing MCCB will be connected through suitable rating bus bar strip type duly insulated. (v) Cost of marking description and matter on the front door as specified and directed by Engr-in-Charge is incl in quoted rate. |
| 29 | M&L for Earthing complete with galvanized steel earth plate electrode 600 x 600 x 6 mm thick buried directly in ground earth pit not less than 2.25mtr deep below normal ground level with top edge of the plate not less than 1.5 mtr below ground level connected to galvanized iron strep 32 x 6 mm as earthing lead by mean of nut/bolt and washer of galvanized iron or steel drawn through 40 mm dia light grade GI pipe as shown in electrical plate no 3 of SSR part I of 2009 including necessary excavation and earth work GI pipe 20mm dia light grade for wateringPCC chamber with PCC cover in cement concrete 1:2:4 Type B1(20mm graded aggregate), funnel, wire mesh, charcoal dust, salt etc, connected to panel board as indicated including testing complete. Note:- (i) Item includes the cost of 7.5 metre GI pipe for protection of earth lead. (ii) Item includes the cost of 7.5 metre GI earth lead. |
| 30 | Supply and fixing of GI pipe with new GI pipes/ Tubes, \"light grade\", galvanised, 150mm bore, ISI marked, laid in trenches or fixed to walls/ poles including mild steel clamps, nuts, bolts and washers; for protection of electric cable, complete all as specified and directed. |
| 31 | Description all as serial item No- 30 here-in-before but for 100mm bore pipe. |
| 32 | Description all as serial item No- 30 here-in-before but for 80mm bore pipe. |
| 33 | Description all as serial item No- 30 here-in-before but for 50mm bore pipe. |
| 34 | Cutting chases, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc. and making good, cutting not exceeding 10cm girth on brick wall/ Cement surface complete all as specified and directed. |
| 35 | Cutting of roads/ hard surface for laying of GI Pipe lines for protection of LT Under ground cable of size not exceeding 30 CM width and 1.0 mtr depth all as specified and directed. |
| 36 | Note:- Deduction for Schedule of credit (Sch \"A\" Part-II) to be made of ₹121630.00 from the total quoted amount of BOQ while accepting the bid. Details of schedule of credit is given in tender documents. |