| 1 | Demolition of cement concrete(unreinforced) of any description and in any position not otherwise specifically provided for and removal of rubbish off the site complete all as spd and directed. |
| 2 | Demolition of cement concrete (reinforced) in ground floors and pavings n exc 15cm thickness (below or above ground level),complete all as spd and directed. |
| 3 | Demolition of brick work built in lime mortar or cement lime mortar incl all quoins, arches pillars etc and removing unserviceable material exc 100 mtr as specified. |
| 4 | Excavating in trenches, nexc 1.5m wide and nexc 1.5m in depth for foundation etc or for shafts, wells , cesspits, manholes pier holes etc n.exc 10 sqm on plan and n exc 1.5m in depth and getting out soft/loose soil complete all as spd and directed |
| 5 | M&L for moorum/red bajri filling in pavings, spread and levelling in layers n.exc 15 cm thick including well ramming and watering as required, complete all as spd and directed. |
| 6 | M & L for Cement concrete (1:4:8) Type D2 using 40 mm graded crushed stone aggregates as in foundations, filling and mass-concrete complete all asspecified and directed. |
| 7 | M & L for Cement concrete (1:3:6) Type C2 using 40 mm graded crushed stone aggregates as in foundations, filling and mass-concrete complete all asspecified and directed. |
| 8 | M&L for old size brick work with fly ash bricks straight or curved on plan exc 6 m mean radius build in CM 1:4 all as specified as directed. |
| 9 | All as per item No 8.00 mentioned here-in-before but except bricks complete all as specified and directed. |
| 10 | M&L for cement concrete type B-0, 1:2:4 (using 12.5 mm graded crushed stone aggregate) in surface channels and drains for benching complete all as specified and directed. |
| 11 | M&L for rendering 15mm thick on fair faces of brick work or concrete surfaces in cement mortar (1:4) and finish smooth & even with using extra cement complete all as specified and directed. |
| 12 | M&L forforming fair finish drain channelinner girth exc 30 cm but not exc 50 cm in girth in cement concrete using extra cement complete all as specified and directed. |
| 13 | M&L for Providing cement concrete type B-0, 1:2:4 (12.5mm grades aggregate) in window or door cills,lintels, bressumers,steps, quoin blocks (for use with masonry), string courses, copings. kneelers, apex stones, pier caps, columns, posts, boundary pillars, bed plates, pintle blocks,ancho-rage blocks, bonders (for stone walling). corbels, brackets, etc including frames(of any section indicated), with plain fair faces, includingchamfers, weatherings, throat- ing etc. and setting in mortar 1:4 complete with joints to match complete all as spd and directed. |
| 14 | M&Lfor RCC precast cement concrete type B-1 1:2:4 (20mm graded stone aggregate) as in cover slab for drain and similar article with plain face set in cement mortar 1:6 complete all as spd and directed |
| 15 | M&L for Providing, cement concrete type B1 1:2:4 (Using 20mm garded aggregate) in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses,lacing courses, parapets and railings upto 60 cm in height,copings, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, complete all as spd and directed |
| 16 | M & L for TMT bars 6 to 8mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with the including mild steel wire (annealed) not less than 0.9mm dia or securing with clipscomplete all asspecified and directed. |
| 17 | S&F for 600mm bore reinforced concrete pipes, class NP2 , laid and jointed complete all as spd and directed. |
| 18 | Material and labour for cement concrete bed to drain pipe for 600mm bore of pipe including forming cradles in Cement concrete 1:3:6 Type C2 complete all as specifiedand and as directed. |
| 19 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in soft/loose soil complete all asspecified and directed. |
| 20 | Removing excavated material exc. 500 m or part thereof beyond 500 m and upto total distance of 1.5 km at a level not exc. 1.5 m above the starting point complete all as specified and as directed. |