| 1 | TRILOCHAN PUPS OF PURI MUNICIPALTY |
| 2 | Dismantling and removing R.C.C. columns beams slab staircase landing lintels including stackingthe useful materials for reuse and removing the debris within 50mlead |
| 3 | Dismentalling and removing of brickwork up to 3.00 metre hight including stacking the useful materials for reuse and removing the debris within 50m lead etc complete as per direction of engineer in charge. |
| 4 | Earth work in Oridinary Soil in foundation including intial lead and 1.5 m. intial lift including rough dressing etcincluding cost, conveyance, royalty taxes of all metarials, etc completed as per the direction of the Engineer-in-charge. |
| 5 | Sand filling in foundation and plinth with approved river sand well watered and rammed including cost, conveyance, royalty taxes of all metarials etc. completed as per the direction of the Engineer -in- charge. |
| 6 | P.C.C (1:3:6) in foundation and plinth using 40mm H.G.C.B metal including cost, conveyance, royalty etc complete as per the direction of engineer incharge.( Data for 1.00 cum) |
| 7 | R.C.C. work of M-25 grade with 20mm and down grade black hard granite (crusherbroken) stone chips including hoisting and laying.Foundation Base column |
| 8 | Grade Beam |
| 9 | Fly ash brick masonry in cement mortar (1:6) in foundation and plinth including cost, conveyance , royalty etc complete as per the direction of engineer incharge.( Data for 1.00 cum) |
| 10 | Cutting, straightening coiled bent up HYSD bar or Tor steel bending, binding, welding and joining of necessary and tying the grills and placing in position as required for R.C.C. work as per direction of the Engineer In Charge. |
| 11 | R.C.C. work of M-25 grade with 20mm and down grade black hard granite (crusherbroken) stone chips including hoisting and laying. |
| 12 | Col up to RL |
| 13 | Lintel |
| 14 | Chajja |
| 15 | Roof Beam |
| 16 | Roof Slab |
| 17 | Cutting, straightening coiled bent up HYSD bar or Tor steel bending, binding, welding and joining of necessary and tying the grills and placing in position as required for R.C.C. work as per direction of the Engineer In Charge. |
| 18 | Flyash brick work in cement mortar (1:6) in super structure of approved quality including cost, conveyance & royalty etc. complete as per the direction of the Engineer-in-charge. |
| 19 | 12 mm thick plaster with cement mortar (1:6) over brick masonary including all cost, conveyance & royalty etc complete as per direction of the Engineer-in-charge. |
| 20 | 16 mm thick plaster with cement mortar (1:6) over stone/brick masonary including all cost, conveyance & royalty etc complete as per direction of the Engineer-in-charge. |
| 21 | 6 mm thick plaster with cement mortar (1:4) for plaster over R C C surfaces including all cost, conveyance & royalty etc complete as per direction of the Engineer-in-charge. |
| 22 | 12 mm thick plaster with cement mortar (1:4) with neat cement punningover stone/brick masonary including all cost, conveyance & royalty etc complete as per direction of the Engineer-in-charge. |
| 23 | 25mm thick grading plaster with c.c (1:2:2) using 6mm bazuri including cost, conveyence, royalties, taxes etc of all materials, costs of all labour sundries T& P etc complete as per direction of engineer in charge.(Data for 1.00 sqm) |
| 24 | Fixing Antiskid tiles in floors,treads or steps & landing on 25 mm thick bed of cement mortar( 1:1) jointed with neat cement slurry mixed with pigment to match the shades of the tiles including rubbing & polishing complete. |
| 25 | Fixing tiles in dados,skirting & risers of steps on 12 mm thick cement plaster (1:3) jointed with neat cement slurry mixed with pigment to match the shades of the tiles including rubbing & polishing complete . |
| 26 | Priming One Coat with approved Primer On New Surface |
| 27 | Weather coat two coats to walls Finishing wall with with weather coat of approved shade on new work to give an even shade,including cost, conveyence, royalties, taxes etc of all materials, costs of all labour sundries T& P etc complete as per direction of engineer in charge. |
| 28 | Supply of Iron Windowgrill including all cost, conveyance & taxes etc complete as per direction of the Engineer-in-charge. |
| 29 | Painting with Enamel paint of approved quality and shad over surface with 2 coats over 1 coat of primer etc.including all cost, conveyance & royalty etc complete as per direction of the Engineer-in-charge. |
| 30 | R.C.C. work of M-20 grade with 20mm and down grade black hard granite (crusherbroken) stone chips including hoisting and laying. |
| 31 | Col 1st floor |
| 32 | Lintel in First floor |
| 33 | Chajja in First floor |
| 34 | Roof Beam in First floor |
| 35 | Roof Slab in First floor |
| 36 | Cutting, straightening coiled bent up HYSD bar or Tor steel bending, binding, welding and joining of necessary and tying the grills and placing in position as required for R.C.C. work and hoisting, lowering and laying including cost, conveyance and taxes of HYSD bar or Tor steel and binding wires of 18 to 20 gauge as required for RCC work for bending, binding tying the grills in all floors and payment will be made on weight of HYSD bar Tor Steel only. The weight will be calculated as per approved co-efficient Kg/Mt. length and no separate payment will be made towards binding wire etc. as per the Engineer In Charge. |
| 37 | Fly ash brick work in cement mortar (1:6) in FIRST FLOOR using Fly Ash bricks of approved quality including cost, conveyance & royalty of all metarials etc complete as per direction of the Engineer-in-charge. |
| 38 | 12 mm thick plaster with cement mortar (1:6)in FIRST FLOOR over brick masonary including all cost, conveyance & royalty etc complete as per direction of the Engineer-in-charge. |
| 39 | 16 mm thick plaster with cement mortar (1:6) in FIRST FLOOR over stone/brick masonary including all cost, conveyance & royalty etc complete as per direction of the Engineer-in-charge. |
| 40 | 6 mm thick plaster with cement mortar (1:4) In FIRST FLOOR for plaster over R C C surfaces including all cost, conveyance & royalty etc complete as per direction of the Engineer-in-charge. |
| 41 | 12 mm thick plaster with cement mortar (1:4) in FIRST FLOOR with neat cement punningover stone/brick masonary including all cost, conveyance & royalty etc complete as per direction of the Engineer-in-charge. |
| 42 | Supplying,fitting & fixing vitrified tile in floors of size (600x600)mm of approved make conforming to IS:13755 laid on 20 mmthick cement mortar(1:4) & filling joints with white cement of approved quality including cost of all materials,labour T & P etc required for the work all complete as per direction of Engineer-in-charge(For new work only) |
| 43 | Fixing vitrified tiles in dados,skirting & risers of steps on 12 mm thick cement plaster (1:3) jointed with neat cement slurry mixed with pigment to match the shades of the tiles including rubbing & polishing complete . |
| 44 | Priming One Coat with approved Primer On New Surface |
| 45 | Weather coating two coats to walls Finishing wall with with Weathercoat of approved shade on new work to give an even shade,including cost, conveyence, royalties, taxes etc of all materials, costs of all labour sundries T& P etc complete as per direction of engineer in charge. |
| 46 | Supply of Iron Windowgrill in FIRST FLOOR including all cost, conveyance & taxes etc complete as per direction of the Engineer-in-charge. |
| 47 | Painting with Enamel paint in FIRST FLOOR of approved quality and shad over surface with 2 coats over 1 coat of primer etc.including all cost, conveyance & royalty etc complete as per direction of the Engineer-in-charge. |
| 48 | Recessed wiring to Light Point / Fan Point / Exhaust Fan Point / Call Bell Point with 1.50 sq. mm FR PVC insulated Single Core Multi standard Copper Conductor of ISI marked with 20 mm dia non-metallic PVC flexible conduit with 5 Amp, 250 Volt piano type swich ISI marked and ceiling rose ISI marked mounted on MS box having front bakelite cover of suitable size, MS box with 1.0 sq. mm FR PVC insulated Single Core Multi standard Copper Conductor of ISI marked as earth wire including all accesories and connection as per direction of engineer in charge. (Make of wire Finolex / L&T / Anchor / Hevels / V Guard) |
| 49 | Recessed wiring to Light Point / Fan Point / Exhaust Fan Point / Call Bell Point with 1.50 sq. mm FR PVC insulated Single Core Multi standard Copper Conductor of ISI marked with 20 mm dia non-metallic PVC flexible conduit with 5 Amp, 250 Volt piano type swich ISI marked and ceiling rose ISI marked mounted on MS box having front bakelite cover of suitable size, MS box with 1.0 sq. mm FR PVC insulated Single Core Multi standard Copper Conductor of ISI marked as earth wire including all accesories and connection as per direction of engineer in charge. (Make of wire Finolex / L&T / Anchor / Hevels / V Guard) |
| 50 | Recessed wiring to Light Point / Fan Point / Exhaust Fan Point / Call Bell Point with 1.50 sq. mm FR PVC insulated Single Core Multi standard Copper Conductor of ISI marked with 20 mm dia non-metallic PVC flexible conduit with 5 Amp, 250 Volt piano type swich ISI marked and ceiling rose ISI marked mounted on MS box having front bakelite cover of suitable size, MS box with 1.0 sq. mm FR PVC insulated Single Core Multi standard Copper Conductor of ISI marked as earth wire including all accesories and connection as per direction of engineer in charge. (Make of wire Finolex / L&T / Anchor / Hevels / V Guard) |
| 51 | Recessed wiring for 5 / 6 Amp socket outlet with 2 X 1.50 sq. mm FR PVC insulated Single Core Multi standard Copper Conductor of ISI marked with 20 mm dia non-metallic PVC flexible conduit with 5 Amp, 250 Volt piano type swich ISI marked, Phenolic laminated sheet of suitable size ISI marked MS box and earthing point with 1 X 1.50 sq. mm FR PVC insulated Single Core Multi standard Copper Conductor for loop earthing etc. as required, as per direction of engineer in charge. (Make of wire Finolex / L&T / Anchor / Hevels / V Guard) |
| 52 | Recessed wiring to Sub-Main in 2 X 4.00 sq. mm FR PVC insulated Single Core Multi standard Copper Conductor of ISI marked with 25 mm dia non-metallic PVC heavy duty flexible conduit with 1.60 mm thick, along with 1 X 2.50 sq. mm FR PVC insulated Single Core Multi standard Copper Conductor as earth wire as required as per direction of Engineer-in-Charge. (Make of wire Finolex / L&T / Anchor / Hevels / V Guard) |
| 53 | DISTRIBUTION BOARD |
| 54 | Providing and fixing Single Pole MCB with sheet steel enclosure, distribution board on surface / recess complete with tinned copper bus bar , neutral bus bar, earth bar, din bar, detachable gland plate inter connection phospate and powder painted including earthing etc. as per direction of Engineer-in-charge. |
| 55 | Supply, Installation, Testing and Commissioning of pre-wired fluorescent fiiting / compact fluorescent fitting /LED fitting of all sizes complete with all accessories and lamp etc. directly on ceiling /wall or recessed in false ceiling , including connection with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor and earthing as required. |
| 56 | Surface mounted indoor type 12W ROUND LED Luminaire with LED Lamp Similar to WIPRO Cat No. LD80-101-XXX-60-SM or equivalent. |
| 57 | Supply, installation, testing and commissoning of 63amp TPN main switch of following capacity (IS 13940 part-3/19930 on existing surface / wall mounting and complete with HRC fuse links inter connections, earthing etc as per direction of Engineer-in-charge.9SEIMENS/HPL/ANCHOR/L&T/HAVELS/C&S/RK) |
| 58 | Supply, Installation, Testing and Commissioning of ceiling fan 1200mm sweep, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq.mm FR PVC insulated single core multiatrand copper conductor etc. as required. |
| 59 | Supply and fixing Earthing with G.I earth pipe 3mtr. Long 40mm dia ISI marked including accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal and salt as required |
| 60 | Providing and fixing G.I tape 20 mm X 3 mm thick on parapet of surface of wall for lightning conductor complete as per direction of Engineer-in-charge. |
| 61 | Providing and fixing Copper tape 32 mm X 6 mm from earth electrode directly in ground as required. |
| 62 | Providing & Fixing Chlorinated Polyvinyl Chloride (CPVC) pipes confirming to IS 15778 having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings.This includes jointing of pipes & fittings with one step CPVC solvent cement,trenching ,refilling & testing of joints complete as per direction of Er-in-charge. |
| 63 | (i) 15mm dia SCH-80 |
| 64 | (i) 20mm dia SCH-81 |
| 65 | (i) 25mm dia SCH-82 |
| 66 | Supplying all materials, labour, T&P and cutting holes through existing brick work including making good the damages in cement mortar (1:4) for taking G.I. Pipes and fittings/ P.V.C. pipes and fittings etc. all complete as per P.H. specification and direction of Engineer-in-charge. |
| 67 | Fixing water closet ,squatting pan (Indian type W.C Pan) confirming to IS 2556: Part 3 -2004 duly embeded in cement concrete 1:4:8 using hard granite metal 4cm nominal size all complete as per specification. |
| 68 | Providing and fixing P.V.C. low level flushing cistern with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete |
| 69 | Providing and fixing 15mm dia CP Bib Cock body |
| 70 | Providing and fixing 15mm dia CP angular stop cock |
| 71 | 15mm dia pillar cock (Cera PRS-031) |
| 72 | 25 mm dia brass/ gunmetal Fullway Valve |
| 73 | Stainless steel jali grating with hole of multi floor trap |
| 74 | 15mm dia CP Health Faucet of Jaquar 1.0mtr long ALD-573. |
| 75 | Providing and fixing Vent cowl with ss jali |
| 76 | Fixing Rotational moulded Poly Propelene double layer cylindrical vertical water storage tanks confirming to IS 12701-1996 including cutting holes through the tank and fixing mild steel tubes and fitting and providing extra sockets and jam nuts, fixing ball valve etc,including hosting upto a height of 5 mtr above ground level and placing the tank to the required postion etc all complete as per specification and direction of the Er-in-charge. |
| 77 | Providing and fixing on wall face unplasticised Rigid PVC soil, waste and rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS: 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes |
| 78 | [ ii ] 110mm diameter |
| 79 | Fixing Wash down water closet, (European type W.C Pan) with integral S or P trap confirming to IS 2556: Part 8 -2004 to the floor with soil pipe in cement mortar (1:1) etc all complete as per specification & fixing of plastic seat & cover for wash down water closet with chormium plated brass hinges and rubber buffers all complete as per specifications. |
| 80 | Fixing Wash basin with hole for Pillar taps confirming to IS 2556 : Part 4 -2004 with cast iron or MS brackets painted white including cutting holes in walls and making good the damages etc all complete as per specification. (550x400) |
| 81 | CERA COUNSEL Cat. No. S2040101 WASH BASIN |
| 82 | Fixing PVC waste pipe of following nominal diameter for wash basin or sink including brass check nut complete as per specification |
| 83 | Fixing Chromium Plated brass waste of the following nominal diameter for wash basin and sink as per specification |
| 84 | Fixing Flat back urinal confirming to IS 2556: Part 6 -1996 including connecting the urinal of 420x395x635 MM sizes respectively with wash pipe by means of white lead mixed with chopped hemp etc all complete as per specifications. |
| 85 | Fixing 600x450mm bevelled edge mirror of superior glass mounted on 6mm thick A.C sheet or plywood sheet and fixed to wooden plugs with Chromium Plated brass screws and washers complete as per specification and direction of the Engineer in charge |
| 86 | Laying in trenches unplasticised PVC pipes conforming to IS:4985-2000 and specials of the following outside diameter for all classes including jointing with supply of approved solvent cement by non-heat application method including testing as per spectification complete.(Earth work in trenches to be measured and paid for separately) etc all complete as per specification and direction of the Er-in-charge. |
| 87 | ii) 110mm dia UPVC pipe class-3 (0.60 mpa) |
| 88 | Making MS step Iron in 20mm dia MS steel bars & fixing into walls of manhole dully embeded in CC 1:3:6 complete a sper specification. |
| 89 | Fixing 15mm dia PVC inlet connection pipe and making connection with pillar cocks and supply mains for wash basin complete as per specification. |
| 90 | Fixing standard sized Chromium Plated brass towel ring fixed to wooden plugs with Chromium Plated brass screws, complete as per specification. |
| 91 | Display Board Please Enable Macros to View BoQ information |