| 1 | S/D the following size FRLS of PVC insulated copper conductor cable in the existing surface /recess PVC conduit as reqd. 3x 2.5 sqmm |
| 2 | Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor cable in the existingand earthing the point with 1.5 sqmm copper cable etc as reqd. at site Group |
| 3 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed heavy class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C |
| 4 | Servicing/overhauling of HTpanelwith proper tools and testing all the equipment\"s i/c tightening of connection ,cleaning, tapping testingin the presence of Authorised personaletc. as required at site. |
| 5 | Supplying and Fixing of LT panel door lock made of anti-Corrosion material, having PVC knob for opening/closing, in existing LT panel etc. complete as required. |
| 6 | Supplying and Fixing of 3 phase digital voltmeter in existing LT panel incluiding connection and all mounting accessories complete as required. Make Laurtz knudsen Model no CI 1,Cat.No.WL132010OOOO or equivalent model of ABB, Siemens |
| 7 | Supplying and Fixing of 3 phase digital ammeter in existing LT panel incluiding connection and all mounting accessories complete as required. Make Laurtz knudsen Model no CI 1,Cat.No.WL131010OOOO or equivalent model of ABB, Siemens |
| 8 | Testing of existing HT panel with High Pot.machine till suitable rating including bus bar, CT, PT etc connection and identify of leakage points by authorized person of relavent class/categoryas required at site. |
| 9 | Testing /calibration of protection relay of VCB\"s at HT panel/transformer i/c alarm trippiing circuit etc as reqd. at site |
| 10 | Testing of existing VCB with High Pot.machine till suitable rating including bus bar, CT, PT etc connection and identify of leakage points by authorized person of relavent class/categoryas required at site. |
| 11 | Servicing of Bus Trunking with dry cloths and hand blower i/c inspection of fractures in insulation, tightening of nut bolts, etc as required at site |
| 12 | Insulation/cleaningofbus bar , removing of carbon anddressing of laying cable including tightening of cables, endtermination nut bolts etc as required at site |
| 13 | Supplying and Fixing of LED indicator of colour Red/Green/Yellow/amber in existing LT distribution panel of size22.5 mm in cluster design, suitable for DC/AC voltage, etc complete as required.Make- Lauritz Knudsen , Cat. No. EPL Gen Next Pro or equivalant model of ABB/Seimens/Salzer |
| 14 | Removing the connection from incoming and outgoing cable from2 transformerin the presense of Authorised personaletc. as required at site. |
| 15 | Replacement of defective control wiring including testing of protection relay in existing HT panel and alarm , tripping circuit etc as reqd. |
| 16 | Servicing , testing of 400 amp VCB\"s with proper tools and testing equipment i/c racking outt/in tightening of bolt checking /cleaningwith petrol/CRC/CTC and dry colth including removing the dust particles and mositure completely and configration of protective relay etc as reqd. at site |
| 17 | Supplying and fixing of space heater 80 watt 220 volt 50 HZ in the existing HT panel including making connection etc as reqd. at site |
| 18 | Repairing of existing VCB by replacement of following parts complete with all accessories i/c disconnection and removal of faulty parts , connection of parts, dressing , testing , configring programming etc as reqd. at site |
| 19 | Adopter |
| 20 | Tulip Cluster |
| 21 | Vaccum Cylindre |
| 22 | Insulator |
| 23 | PT Fuse 3 amps |
| 24 | Providing and fixing exhaust fan 900 RPM with all accessories and making connection etc as reqd if wooden work is reqd 18\" Exhaust fan |
| 25 | S/I/T/C of 150 watts flood light fitting 5700 K pressured dia cast housing with IP65 protection efficient high 220-240V output emitter LED for better distribution with dimension 447 X 163 x 327 mmand 6500 colour with lumens 15000 with all accessoires etc as etc as reqd. at site. ( model no BVP410 LED 150 CW HE NB FG S4 XTFCL) ( Philips ) |
| 26 | Supplying and fixing of angle frame of suitable size ( 18\" x 18\" ) including excavation and repairing the same etc as reqd. at site |
| 27 | Supplyingof one number PVC insulatedand PVC sheathed /XLPE aluminium armoured conductorpower cable confirming to1.1 KV grade of following size direct in wall etc as reqd. 4x16 sqmm |
| 28 | Supplying and fixing of street light pole box of size (250x200x100)complete with all accessories i/c suitable clamps, suitable bakelite sheet, brass screws, washers and 1 Nos. SP MCB 10 amps capacity i/c making connection etc. as required at site. |
| 29 | Supply, Installation, testing and commissioning of pre-wired, Double box fitting with Two no. LED tube of frosted cover design, 18 Watt, 2100 lm, 50000 burning hours, size 1200 mm complete i/c all accessories etc. directly on ceiling/wall, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor cable and earthing etc. as required. fitting equivalent to Philips Make, Cat No. TMC 502 2xT-LED 22W, Tube equivalent to Philips Make, Cat No. Mas LEDTube 1200mm 18W 865 T8I-2100lm |
| 30 | Servicing of existing main LT panel comprising of ACBs and MCCBs with proper tools and testing of equipments/relay interlocking i/c tightening of bolts(Busbar, ACB etc.), cleaning of panel with Blower and dry cloths etc. as required at site. |
| 31 | Servicing of existing Capacitor panel comprising of ACBs, capasitors, relay, contactor etc with proper tools and testing/calibration, equipments i/c tightening of bolts, cleaning of panel with Blower and dry cloths etc. as required at site. |
| 32 | Servicingof ACB\"s 3200/1250/800 amp withproper tools and testing equipments i/c racking out/in tightening of bolts cleaning with petrol/CRC/CTC and dry cloths i/c calibration of relay etc. as required at site. |
| 33 | Repairing and servicing of existingof power pack i/c removing and reconnection of control wirings, testing of control circuit etc as required at site. |
| 34 | P/f of power packcomplete with all accessories i/c removing and reconnection of control wirings, testing of control circuit etc as required at site. Submitting of faulty power pack in engineering store. |