| 1 | Civil, Interior & Plumbing work |
| 2 | Providing and laying 1st quality Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete. |
| 3 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 4 | Poviding and fixing partition upto ceiling height consisting of G.I. frame andrequiredboard,including providingandfixingofframework madeofspecialsectionpower pressed/ roll form G.I. sheet with zinc coating of 120 gms/sqm(both side inclusive), consisting of floor and ceilingchannel50mmwidehaving equal flanges of 32 mm and 0.50 mm thick, fixed to the floor and ceiling at the spacing of 610 mm centre to centre with dash fastener of 12.5 mm diameter50mmlengthorsuitable anchorfastenerormetalscrewswith nylonplugsandthestuds48mm wide having one flange of 34 mm and otherflange36mmand0.50mm \"thickfixedverticallywithinflanges of floor and ceiling channel and placed at a spacing of 610 mm centre to centre by 6 mm dia bolts and nuts, includingfixingofstudsalongboth endsofpartitionfixedflushtowall with suitable anchor fastener or metalscrews with nylon plugs at spacing of 450 mm centre to centre,\" \"andfixingofboardstobothsideof frame work by 25 mm long dry wall screws on studs, floor and ceiling channelsatthespacingof300mm centre to centre. The boards are to be fixedtotheframeworkwithjoints staggered to avoid through cracks,M.S. fixing channel of99 mm width (0.5mmthickhaving twoflangesof9.5mmeach)tobeprovidedatthe horizontal joints of two boards, fixed to the studs using metal to metal flat headscrews,includingjointingand finishingtoaflushfinishwith recommendedjointingcompound, jointingtape,anglebeadsatcorners (25mmx25mmx0.5mm),joint finisher and two coats of primer suitable for board as per manufacture\"sspecificationand directionofengineerinchargeallcomplete.\" - 75mm overall thickness partition with12.5mmthickdoubleskintapered edged plain Gypsum plaster board conforming to IS: 2095: (part I): 2011 (Board with BIS certification marks) |
| 5 | Providing and fixing 15 mm thick Tegular edged light weight calciumsliciate false ceiling at all heights with integral densified calcium silicate reinforced with fibre and natural filler false ceiling calcium silicate reinforced with fibre and natural filler false ceiling as per CPWD Specification 2019, to be laid in true horizontal level suspended on inter-locking metal T-Grid of hot dipped galvanised iron section of 0.33mmthick (galvanized @ 120 grams per sqm including both sides)comprising of main-T runners of size 24x38 mm of length 3000 mm,cross - T of size 24x32 mm of length 1200 mm and secondaryintermediate cross-T of size 24x32 mm of length 600mm to formgrid module of size 600 x 600 mm, suspended from ceiling usinggalvanised mild steel items (galvanizing @ 80 grams per sqm) i.e. 12x50 mm long dash fasteners, 6 mm dia fully threaded hanger rod upto 1000 mm length and L-shape level adjuster of size 76x25x25x1.6 mm fixed with grid and Z cleat of size 25x37x25x1.6mm thick with precut hole on both 25mm flange to pierce into 12x50mm or even bigger size dash fastener if require, fixed with Glavanised iron perimeter wall angle or size 24x24x0.40 mm of length 3000 mm to be fixed on periphey wall / partitionthe help of plastic rawl plugs at 450mm center to center and 40 mm long dry wall S.S screws. The workshall be carried out as per specifications, drawing and as per directionsof the Engineer-in- Charge. |
| 6 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 7 | Wall Painting with Finishingwithpremium plastic emulsion interior paint with low VOCsystem for interiors and exteriors using Primer as per manufacturers specifications :Twoormorecoatsappliedonwalls & ceiling |
| 8 | Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying :(a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours. (b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry. |
| 9 | Painting with synthetic enamel paint on steel work of approved brand and manufacture to give an even shade :Two or more coats on old work |
| 10 | Painting with synthetic enamel paint on wood work of approved brand and manufacture to give an even shade :Two or more coats on old work |
| 11 | Providing & FixingFrosted Translucent,castPVC,self-adhesive vinyl,specialCRYSTAL-effectfilm toreproduceSand-blastingeffecton glass with customized designs, thicknessof2mil(0.05mm)without adhesive(0.8)withadhesivehaving minimumtensilestrengthof3.5 pound/inchat73F(0.6kg/cmat23 C). Adhesion after 24hrs of installationshouldbe4pounds/inch (0.7kg/cm)onAcrylic,Glass Polycarbonate: MCS warranty of 3yrs (if exposed to direct sunlight) to 15yrs (indoors)Application -DECORATIVE/PRIVACYFILM ON GLASSElectronically/computer plotter cut. Applied on glass and other rigid, clear substrates. (partitions, doors, windows etc.) Available in 5 colours |
| 12 | Supplying and fixing Roller Blinds to thefollowingspecifications,Fabric shadeasapproved,sunscreen,dense basketweave5%opennessfactor. Operation: - Manual. Offset side- mountedmetalchainoperated Mounting: Pocket mounted. Shade Orientation: Regular roll, shade cloth fallsatwindowsideofroller. Configuration:Singleband AVERAGELENGTHOFBLINDis2.0 M to 2.5 M. The fabric to be Fire Retardent certified. |
| 13 | Demolishing brick work manually/ by mechanical means including stacking ofserviceablematerialanddisposal ofunserviceablematerialwithin50 metresleadasperdirectionof Engineer-in-charge- In cement mortar |
| 14 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : Of area 3 sq. metres and below |
| 15 | 12mm thick toughened glass door including accessories for toughned glass door including floor spring, handle and lock all complete. |
| 16 | Dismantling stone slab flooring laid in cement mortar including stacking of serviceable material and disposal of unserviceable material within 50 metres lead. For thickness of tiles 10 mm to 25 mm |
| 17 | Dismantling G.I. pipes (external work) including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means including stacking of pipes within 50 metres lead as per direction of Engineer-in-charge : 15 mm to 40 mm nominal bore |
| 18 | Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. |
| 19 | Providing and fixing glazing in aluminium doors, windows, ventilator shutters and partitions etc with EPDM rubber/neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge. with float glass panes of 4.0 mm thickness (weight not less than 10 kg/sqm) |
| 20 | Disposalofmoorum/building rubbish/ malba/ similar unserviceable, dismantledorwastematerialby mechanical transport including loading, transporting, unloading to approvedmunicipaldumpingground for lead upto 10 km for all lifts, complete as per directions of Engineer-in-charge. |
| 21 | Providing and laying in position cementconcreteofspecifiedgrade excludingthecostofcenteringand shuttering-Allworkuptoplinth level :1:2:4 (1 cement : 2 coarse sand (zone- III)derivedfromnaturalsources:4 gradedstoneaggregate20mm nominal size derived from natural sources) |
| 22 | Centering and shuttering including strutting,proppingetc.andremoval of form work for : column, piers, abutments, pillars, posts ans struts |
| 23 | Reinforcedcementconcreteworkin beams, suspended floors, roofs having slopeupto15°landings,balconies, shelves,chajjas,lintels,bands,plain window sills, staircases and spiral staircasesaboveplinthlevelupto floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement: 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate20mmnominalsize derived from natural sources). |
| 24 | Centering and shuttering including strutting,proppingetc.andremoval of form for |
| 25 | Suspended floors, roofs, balconies, access platforms |
| 26 | SteelreinforcementforR.C.C.work includingstraightening,cutting, bending, placing in position and binding all complete above plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 27 | Half brick masonry with common burntclayF.P.S.(nonmodular) bricks of class designation 7.5 in superstructure above plinth level upto V level - cement mortar 1:4 (1 cement : 4 coarse sand) |
| 28 | Extra for providing and placing 2 nos- 6mm dia MS bars at every third course of half brick masanory. |
| 29 | Extra for providing and placing 2 nos-12 mm cement plaster in ratio 1:4 (1 cement : 4 coarse sand) |
| 30 | Providing and fixing in position concealed G.I. section for wall panelling using board of required thickness fixed on the \"W\" profile (0.55 mm thick) having a knurled web of 51.55 mm and two flanges of 26 mm each with lips of 10.55 mm, placed @610 mm C/C in perimeter channel having one flange of 20 mm and another flange of 30 mm with thickness of 0.55 mm and web of length 27 mm. Perimeter channel is fixed on the floor and wall panelling of 1.2 m height with the nylon sleeves@610 mm C/C with fully threaded self-tapping dry wall screws. Board is fixed to the \"W\" profile with 25 mm countersunk ribbed head screws @200 mm C/C., all complete as per the drawing & Directions of engineer-in-charge, the joints of the boards are finished with specially formulated jointing compound and 48 mm wide jointing tape to provide seamless finish. The wall panelling shall be finished with paint as directed by the engineer-in-charge. The top and sides of the wall shall be covered with teak wood having curved shape finished with polish/paint as required-With plain Gypsum plaster board conforming to IS:2095 Part-1:2011 (Board with BIS certification mark) |
| 31 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately).-Second class teak wood |
| 32 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (PartI)non-decorativetype,coreof blockboardconstructionwithframe of 1st class hard wood and well matchedcommercial3plyveneering withverticalgrainsorcrossbands andfaceveneersonbothfacesof shutters:32mmthickincludingISImarked StainlessSteelbutthingeswith necessary screws |
| 33 | Extraforprovidinglippingwith2nd class teak wood battens 25 mm minimum depth on all edges of flush doorshutters(overallareaofdoor shutter to be measured). |
| 34 | Providing & fixing 1.0mm high pressure laminate of approved shade |
| 35 | Supplying & fixing hardware set for doors:Aldrop, door closer, door hinges, back rubber complete in all respect. |
| 36 | Compound Wall-Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kind of soil. |
| 37 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) . |
| 38 | Providing stone masonry of hard stone in foundation and plinth with cement mortar 1:6 (1 cement: 6 coarse sand). |
| 39 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:4 (1 cement : 4 coarse sand) designation 7.5 in foundation and plinth in: Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 40 | Provinding 12 mm cement plaster with mortar 1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing all complete as per specifications and as per direction of engineer-in-charge. |
| 41 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade: New work (two coats) over and including water thinnable primer coat with cement primer after throughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and directions of engineer-in-charge |
| 42 | For closing open space on above floor-Providing and fixing M.S Tuber frames for doors,windows, ventilators and cupboard with rectangular/L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer: Fixing with 15 x 3 mm lugs 10 cm long embedded in cement concrete block 15 x 10 x 10 cm of C.C 1:3:6 (1 Cement: 3 Coarse sand: 6 graded stone aggregate 20 mm nominal size) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. Work includes frame for closing in open corridor area and for closing open space at 1st floor. |
| 43 | Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS:12823 Grade 1 Type II, in panelling fixed in alumnium doors, windows shutters and partition frames with C.P. brass/stainless steel screws etc. complete as per architectural drawings and engineer-in-charge: Pre-laminated particle board with decorative lamination on both sides including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of Engineer-in-charge. Work includes for closing open space at 1st floor. |
| 44 | Providing and fixing M.S grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to opening/wooden frames with rawl plugs screws etc. Work includes Grill for open cooridor and Grill as safety gate for door. |
| 45 | Painting with synthetic enamel paint on wood work of approved brand and manufacturer of required colour to give an even shade: one or more coats on new work |
| 46 | Plumbing Work-Providingandfixingwhitevitreous chinaextendedwallmountingwater closetofsize780x370x690mmof approvedshapeincludingproviding &fixingwhitevitreouschinacistern withdualflushfitting,offlushing capacity 3 litre/ 6 litre (adjustable to 4 litre/8litres),includingseatcover, andcisternfittings,nuts,boltsand gasket etc complete. |
| 47 | Providingandfixingwhitevitreous chinaurinalofapprox.size 620x375x320 mmalong with angle valve and automatic urinal flushing pipeand fixingtowallwithsuitablebrackets all as per manufacturers specification and direction of Engineer-in-charge. |
| 48 | Providing and fixing white vitreous china pedestal for wash basin completely recessed back for the reception of pipes and fittings including complete with all sanitary fittings pillar cock complete in all aspects. |
| 49 | ProvidingandfixingPVC soil,wasteand vent pipes-100mm dia |
| 50 | Providing and fixing bend of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete-100 mm dia |
| 51 | Providingandfixingplainbendof required degree-100mm dia |
| 52 | Providing and fixing double equal plain junction of required degree:(i) 100x100x100x100 mm |
| 53 | Providing and fixing single equal plain junction of required degree :(i) 100x100x100 mm |
| 54 | Providing and fixing terminal guard PVC - 100mm |
| 55 | Providing and fixing trap of self cleansingdesignwithscreweddown or hinged grating with or without ventarmcomplete,includingcostof cuttingandmakinggoodthewalls and floors :(i) 100 mm inlet and 100 mm outlet |
| 56 | Providingandfixing18-8S,type- 304, Stainless Steel towel ring round shape 178 mm outsidediameter, 162 mm inside diameter minimum distancesof55mmfromwallface withroundflangeconcealedfittings arrangementofapprovedqualityand colourallcompleteasper manufacturersspecificationand direction of Engineer-in-charge. |
| 57 | Providing & Fixing PTMT liquid soap container 109mm wide 125mm high and 112mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour weighing not less than 105 grams |
| 58 | ProvidingandfixingCPBrassHand Shower (Health Faucet) with 1 Meter Long Easy Flex Tube in Chrome FinishandWallHookwithN.R.V (BackFlowPreventer)including making all connections, fixing to wall with suitable brackets all as per manufacturersspecificationand direction of Engineer-in-charge- - 15mm nominal dia |
| 59 | Providingandfixing18-8S,type- 304, stainless steelTissue PaperDispenser345mmlong,110 mmwidewith455mmhighhaving 600C-foldor800multifoldpaper towels capacity with loading from bottom including fixing to wall as per manufacturersspecificationand direction of Engineer-in-charge. |
| 60 | Providing and fixing stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in-charge and finished smooth |
| 61 | Providing & fixing C.P. Brass angle valve for wash basin and Gyser points of approved quality confirming to IS:8931 with 15mm nominal bore chrome finish |
| 62 | ProvidingandfixingChlorinated Polyvinyl Chloride (CPVC) pipes, havingthermalstabilityforhot& coldwatersupply,includingall CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 mspacing.Thisincludesjointingof pipes & fittings with one step CPVC solvent cement and the cost of cutting chasesandmakinggoodthesame including testing of joints complete as perdirectionofEngineerinCharge. Concealed work, including cutting chases and making good the walls etc.- (a) 20 mm nominal outer dia Pipes |
| 63 | ProvidingandfixingChlorinated Polyvinyl Chloride (CPVC) pipes, havingthermalstabilityforhot& coldwatersupply,includingall CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 mspacing.Thisincludesjointingof pipes & fittings with one step CPVC solvent cement and the cost of cutting chasesandmakinggoodthesame including testing of joints complete as perdirectionofEngineerinCharge. Concealed work, including cutting chases and making good the walls etc.-(b) 25 mm nominal outer dia Pipes |
| 64 | Providingandfixingbrassstopcock of approved quality :(a) 20 mm nominal bore |
| 65 | Providingandfixinguplasticised PVC connection pipe with brass unions 45cm length 20mm nominal bore |
| 66 | Providing & fixing chrome plated brass Long body bib cock of approved quality conforming to IS statnadard-15mm nominal bore |
| 67 | Electrical Works |
| 68 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required-Group C |
| 69 | Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, 2-way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required. |
| 70 | Wiring for light/ power plug with 2X2.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 71 | Circuit wiring-2X1.5sq.mm+1X1.5sq.mm earth wire |
| 72 | Circuit wiring-2X2.5sq.mm+1X2.5sq.mm earth wire |
| 73 | Circuit wiring-2X4sq.mm+1X4sq.mm earth wire |
| 74 | Circuit wiring-2X6sq.mm+1X6sq.mm earth wire |
| 75 | Circuit wiring-4X10sq.mm+2X6sq.mm earth wire |
| 76 | Circuit wiring-4X16sq.mm+2X6sq.mm earth wire |
| 77 | Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required-1 or 2 Module (75 mmX75 mm) |
| 78 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required - 3 pin 5/6 A socket outlet for AC indoor unit. |
| 79 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 80 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. |
| 81 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. |
| 82 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings as a computer point). |
| 83 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) - 12 way , Double door |
| 84 | Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note: Vertical type MCB TPDB is normally used where 3 phase outlets are required.) 4 way (4 + 12), Double door |
| 85 | Supplying and fixing 63 amps rating, 240/415 volts, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required-Triple Pole |
| 86 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole |
| 87 | Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. -63A |
| 88 | Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required-100A |
| 89 | Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required-63A |
| 90 | Supplying & laying 3.5C x120mm armoured aluminium cable |
| 91 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required - 20mm |
| 92 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required-25mm |
| 93 | Supplying & fixing 600x600mm 36W LED light |
| 94 | Supplying & fixing round downlight12W LED light |
| 95 | Providing & fixing modular MCB switch for Acs. |
| 96 | Providing & fixing three pole RCCB in existing DB |
| 97 | Providing & fixing 4\" LED Tube Light |
| 98 | Providing 1200mm ceiling fan |
| 99 | wiring for lightening/power circuits-1.5mm |
| 100 | wiring for lightening/power circuits-2.5mm |
| 101 | wiring for lightening/power circuits-4mm |
| 102 | wiring for lightening/power circuits-6mm |
| 103 | LED Street light 120W |
| 104 | Earth point excavation |
| 105 | Data/CCTV/Voice (Networking Work) |
| 106 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required -20mm |
| 107 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required -25mm |
| 108 | Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required - 1 run of cable |
| 109 | Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required -2 run of cable |
| 110 | Bullet Camera: Supply, Installation, testing & Commissioning of indoor/outdoorBullet camera on wall/pole with mounting accessories. Minimum 5 Megapixel |
| 111 | Dome Camera: Supply, Installation, testing & Commissioning of indoor Dome camera on wall/ceilingwith mounting accessories. Minimum 5 Megapixel, IR distance- 20 mtrs. or better. |
| 112 | 16 ChannelInput NVR: Supply installation testing and commissioning of 16 channel Network Video Recorder with Support 16 Channel IP camera Input decoding upto 8MP resolution preview and playback Max 160 MbPS Processor Dual Core embedded processor |
| 113 | Monitor- 22\" LED FHD Monitor , 1920x 1080 Pixels, 75Hz, Fliker Free, HDMI, D-Sub. |