| 1 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil as per SI.No. 2.8.1 |
| 2 | Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor: With Chlorpyriphos/Lindane E.C. 20% with 1% concentration as per SI.No. 2.35.3.1 |
| 3 | Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. (Under Floor) as per SI no 2.27 |
| 4 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-lll) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) As per SI no. 4.1.8 |
| 5 | Brick work with common burnt clay (non modular) bricks of class -150 in foundation and plinth in Cement mortar 1:6 (1 cement : 6 coarse sand) as per SI No- 6.1.2 |
| 6 | Brick work with common burnt clay bricks of M-150 Class in super structure above plinth level upto floor V level in all shapes and sizes in cement mortar 1:6 ( 1 cement : 6 coarse sand ) as per SI no 6.4.2 |
| 7 | Brick work with common burnt clay F.P.S. (Non modular) brick of class degnation 7.5 in superstructure above plinth level up to floor 1:4 (DSR- 6:4:1) |
| 8 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level 1:1.5:3 (1 cement : 1.5 coarse sand (zone-lll) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) Upto Plinth Lvl as SI No-5.1.2 |
| 9 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III)derived from natural sources : 3 graded stone aggregate 20 mm nominal sizederived from natural sources). Above Plinth Lvl as SI No-5.3 |
| 10 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-lll) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). as per SI No. 5.3 |
| 11 | Steel reinforcement for R.C.C. work ready to use \"cut and bend\" placing in position and binding all complete up to plinth level & aboue plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. As per SI. No.- 5.22.6 & 5.22A.6 |
| 12 | Steel work welded in built up sections / framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. In grantings, frames, guard bar, ladder, railing, brackets, gates and similar works as per SI no. 10.25.2 |
| 13 | Steel work welded in built up sections / framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. In grantings, frames, guard bar, ladder, railing, brackets, gates and similar works as per SI no. 10.25.2 |
| 14 | Providing and fixing M.S. Tubular frames for doors,window, ventilators etcFixing with c.c. block 15x10x10 cm of C.C. 1:3:6. (DSR- 10.15.1) |
| 15 | Providing and fixing T-iron frames for doors,window, ventilators etcFixing with c.c. block 15x10x10 cm of C.C. 1:3:6. (DSR- 10.13.1) |
| 16 | 15 mm thick cement plaster of mix 1:6 ( 1 cement & 6 course sand ) Inner Side as per IS 13.5.2 |
| 17 | 12 mm thick cement plaster of mix 1:6 ( 1 cement & 6 course sand ) Outer Side as per IS 13.4.2 |
| 18 | Making grooves 10 to 12 mm widex8mm deep in plaster the all or in cilling vertically horzontally as required. DSR 5.30 |
| 19 | Add for plaster drip coures in plastered surface or moulding to R.C.C. Projection. DSR 5.30 |
| 20 | 40 mm thick c.c. flooring 1:2:4 in finished all work .DSR-11.3.1 |
| 21 | Cement plaster 1:3 finished with a floating coat of neat cement, 20 mm cement plaster. DSR-13.9.2 |
| 22 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using primer as per manufacturers specifications: penting steel work. two or more applied @ 0.90 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.80 litre/10 sqm) as per Sl no. -13.48.3 |
| 23 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using primer as per manufacturers specifications: penting steel work. two or more applied @ 0.90 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.80 litre/10 sqm) as per Sl no. -13.48.2 |
| 24 | Finishing walls with water proofing cement paint of required shade: New work (Two or more coats applied @ 3.84 ltr/10 sqmDSR -13.44.1 |
| 25 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour : New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre as per Sl no. -13.41.1 |
| 26 | White washing with lime to give an even shade : New work (three or more coats ) DSR-13.37.1 |
| 27 | Providing & fixing glass panes with puttyand glasing clips in steel door window all complete with 4.0 mm thick glass panes. DSR-10.30.1 |
| 28 | Providing and fixing ISI marked Oxidised M.S. Slliding door bolt with nuts and scerew etc, complete size 250x16 mm DSR- 9.62.2 |
| 29 | Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete (Copper oxidised as per IS 1378) (a) 250mm x 10mm. SI 9.63.1 |
| 30 | Providing and fixing ISI marked oxidised M.S. handles conforming to IS:4992 with necessary screws etc. complete (Copper oxidised as per IS 1378) (a) 125 mm. As per SI 9.66.1 |
| 31 | Centering and shuttering including stutting, propping etc. and removal of form. (i) Beam /Band as per SI- 5.9.5 |
| 32 | Weather shade,Chajjas,corbels etc,including edges (DSR 5.9.19) |
| 33 | Centering and shuttering including stutting, propping etc. and removal of form. (iv) Slab as per SI- 5.9.3 |
| 34 | TUBE WELL WORK Boring/drilling bore well of riquired dia for casing/strainer pipe by suitable method prescribed in IS: 2800 (part I), colectting sample from different strata, preparing and submitting stata chart /bore long, including hire &running charges of all equipments, tools,plants & machineries required for the job, all complete as per direction of engineer-in-charge, up to 90 metre depth below ground level. DSR-23.1 All type of soil DSR-23.1.1 350 mm dia DSR-23.1.1.2 All type of soil DSR-23.1.1 350 mm dia DSR-23.1.1.2 |
| 35 | Boring/drilling bore well of riquired dia for casing/strainer pipe by suitable method prescribed in IS: 2800 (part I), colectting sample from different strata, preparing and submitting stata chart /bore long, including hire &running charges of all equipments, tools,plants & machineries required for the job, all complete as per direction of engineer-in-charge, up to 90 metre & up to 150 metre depth below ground level. DSR-23.2 All type of soil DSR-23.2.1 350 mm dia DSR-23.2.1.2 |
| 36 | Supplying ,assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well cassing (CM) pipe of riquired dia, conforming to IS: 12818 including required hire &running charges and labour charge fittings & accessories etc. all complete as per direction of engineer-in-charge, ection of engineer-in-charge. DSR-23.3 100 mm nominal size dia DSR- 23.3.1 100 mm nominal size dia DSR- 23.3.1 |
| 37 | Supplying ,assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well cassing (CM) pipe of riquired dia, conforming to IS: 12818 including required hire &running charges and labour charge fittings & accessories etc. all complete as per direction of engineer-in-charge, ection of engineer-in-charge. DSR-23.3 100 mm nominal size dia DSR- 23.4.1 |
| 38 | Gravel paking in tubewell construction in accordence with IS: 4097, including providing gravel riqirement,, all complete as per direction of engineer-in-charge, as per Market. |
| 39 | Devlopment of tube well in accordence with IS: 11189 to stablis maximum rate of usable water yield without sand content 9beyond permissible limit), with riquired capacity air compressor for riquired time till well is fullydevolopd all complete as per direction of engineer-in-charge. DSR 23.12 |
| 40 | P/F suitable size threaded milled steel cap or spot welded plate to the top of bore well housing /casing pipe, removable as per riquirment, all complete of bore well. DSR- 23.13 100 mm dia DSR- 23.13.1 100 mm dia DSR- 23.13.1 |
| 41 | P/F M,S. clamp of riqurid diav to top of Boring/drilling bore well of casing hausing pipe of tube well as per IS: 2800 (part I), including necessary bolts & nuts of riquired size complete 100 mm dia clamp. DSR-23.14.1 |
| 42 | P/F M,S. Bail plug/ bottom plug of riquired dia to the bottom of pipe assembly to tube well as per IS; 2800 (part l) 100 mm dia. DSR-23.15.1 |
| 43 | P/F G.I. pipe complete with G.I. fitting including trenching and refilling etc. 50 mm dia nominal bore. DSR- 18.12.6 |
| 44 | Supply and instalation of 15.0 hp KBS/ CROMPTION MAKE Submersible pump set complete with contrle pannele .as per MARKET RATE. |
| 45 | Supply and fixing of nylon mesh for filter pipe .as per MARKET RATE. |
| 46 | Supply and fixing of submen copper cable (3x4) .as per MARKET RATE. |
| 47 | Electric logging of bore hole & Sample testing .as per MARKET RATE. |
| 48 | Supply and fixing of Steel wire rope .as per MARKET RATE. |
| 49 | Cartage of Boring equipment/rig machine/ compresor,as per MARKET RATE. |
| 50 | ELECTRIFICATION WORK Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C DSR-1.10.3 |
| 51 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire DSR-1.14.1 |
| 52 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire DSR-1.14.2 DSR-1.14.2 |
| 53 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 4 sq. mm + 1 X 4 sq. mm earth wire DSR-1.14.2 DSR-1.14.2 |
| 54 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.DSR-1.31 DSR-1.31 |
| 55 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. DSR-1.32 |
| 56 | Supplying and fixing 20 Amp, 240/415 V,SPN industrial type socket oulet, with two pole and earth metal enclosed plug top along with 20 amp. \"c\"curve, SP MCB in sheet steel enclosured commissioning etc. as required. DSR-2.18 |
| 57 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole DSR-2.10.1 |
| 58 | S/F of 40 amp. TP MCB (10KA) C CURE. CAT A. MR. |
| 59 | S/F of 40 amp. FP MCB (10KA) C CURE. CAT A. MR. |
| 60 | Supplying and fixing following rating, four pole (three phase & neutral) 415 volts,residual current circuit breaker (RCCB), having in sencivity current up to 300 millamperer in the existing MCB DB , complete with connection, testing and commissioning etc, as riqurid . DSR-2.15.2 40 Amp |
| 61 | Supplying & Laying of 25mmx5mm G.I. Strip at 0.50 metre below ground as strip for earthing purpose as required complete in all respects. DSR-5.9 |
| 62 | Providing laying and fixing following dia G.I. pipe (midium class) in ground complete with G.I. fitting including trenching required. DSR-14.3.3 100 mm dia |
| 63 | Supplying and fixing following modular switch/socket on the existing modular plate & switch box as required. DSR-1.24.1 5/6 A switch |
| 64 | DSR-1.24.4 3 pin 5/6 A socket outlet |
| 65 | Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required. DSR-1.41 |
| 66 | Supply and fixing of LED Tube Light with batten suitable for upto 1 X 22 watt LED tube light fitting including tube on Surface complete in all respect. - CAT-AAA As per market |
| 67 | Supply and laying of aluminium conducter, PVC insulated armoured, served, sheeted cable 1000 bolts grade at a depth of 750mm below ground level over a cushion of 75mm thick sand alround and protected with burnt bricks on sides and top on surface, the cable run shall be fixed on M.S. clamps etc. of suitable size. or as directed by the Engineer-Incharge, complete in all respect. the armouring of the cable shall be properly connected with the earth conductor by clamps etc. As per market |
| 68 | Supplying and fixing of brass nickle plated compression gland for pvc insulated aremoured served sheaththed, underground cableincluding rubber ring etc. As per market |
| 69 | Supplying and fixing of plain or pin type copper tin plated cable socket (lug) to cable leadsfor pvc insulated aremoured cable Insulating with tape and making connection.served sheaththed, underground cableincluding rubber ring etc. As per market size 25 sq mm Please Enable Macros to View BoQ information |